Cooling systems

By no means should be wire ties or terminals, as they cause false contacts, and as a result there is a high current overheating the electric motor or compressor and can get burned if the compressor or electric motor. Verification and testing of the compression process and understanding Objective Verification of the compression process and a hermetic compressor suction through burning through electrical accessories and directly. Introduction verification suction and compression process intended to diagnose at a time normally functioning and abnormal compression process in the refrigeration cycle and the physical condition of the electrical system in the winding can be detected the continuity of the coils starting work and common since through the compressor as the main element of the cycle and the system can detect electrical and mechanical faults such as: the gheata carbonica compressor works but no product temperature is reduced. thermal protector is triggered when connecting the compressor. The fan works but the compressor does not start. Practice Development is developed through the following steps: - Disconnect the system compressor. - Connect in Appendix compressor load a section of copper pipe 25 cm long approximately by welding. - Connect in downloading another connector with the same characteristics of the previous step. - Connect in each nut one welded pipe nipple inch flare. - Seal the compressor suction line such that the gas compressor sucks only having stored the compressor crankcase. - Connect gauge low load Appendix. - Connect the high pressure gauge welded to the connector on the compressor discharge. - Perform the electrical connection described in the electrical test of the compressor, as shown in the figure below: The above connections vary according to the capacity of the system and compressor. - Start the compressor for a period of 3 seconds and disconnect immediately, during this time the low pressure gauge should indicate a vacuum of approximately 20 inches of mercury and high pressure. - Note that these pressures remain far came at a time of 15 minutes. Note: If pressures remain indicates that the valves are in good condition, if high pressure drops and the suction pressure increases towards

zero indicates that the valves are dirty driveways (valves crossed). When the compressor is on, it indicates that electrical problems. Other techniques to perform for the verification of the mechanical parts inside the compressor is do the following: Perform manual testing of suction and discharge Disconnect gauge set and load appendix the discharge outlet. Connect the compressor to the outlet so that switch. Place your thumb on the compressor suction during this operation and with the other hand place another finger on the compressor discharge.

Potrebbero piacerti anche