Sei sulla pagina 1di 14

Concorde Pay@Table Installation Guide Version 1.

Introduction Concorde Pay@Table is an EMV certified card payment solution specifically designed for restaurants who offer their customers table service and is exclusive to FNB SpeedPoint. Solution Architecture

Terminology The solution utilises various software, settings and hardware components including: Micros 3700 POS software running on Backoffice server and on Terminal in store Micros Table Pay Software to allow Vx670 to close open checks on the Micros system Micros TablePay License Required to use Table Pay software from Micros Micros CCI Interface for Credit card button on POS?? Concorde DLL handles transactions between POS and TRM TablePay Bridge Software used to communicate with Vx670s and TRM + DLL?? Traderoot Merchant Software used to send transactions to Concorde EFT Switch BIN File List of Cards containing Debit/Credit/EMV accounts Etherpad Device to handle communication between TRM and Vx810 VX670 Wireless device used to print checks, pay and close open checks via cash/card VX810 Wired device connected to Etherpad to handle card transactions. Wi-Fi Router Secure communication provider between Vx670s and TRM SSID Secure hidden network that Vx670s communicate on WPA secure protocol used between Vx670s and Wi-Fi Concorde Back Office Reporting and lookup tool for merchant information and transactions Page 2 of 14

Wireless Access Point The wireless AP must be configured with the encrypted SSID as generated by Concorde Back Office per store. The wireless AP must have WPA enabled and an encrypted WPA key setup as per Concorde Back Offices key generation. Note: The IPs on the wireless devices must be set up in theTRM as separate gateways. Vx810 + Etherpad Setup Please refer to the Installation manual for the Concorde 1800 to setup and install the etherpad. The Vx810 does not need to be configured. It only has to be connected to the correct port on the etherpad. Table Pay Setup:

Page 3 of 14

Table Pay Bridge Setup for TP from micros. Busy The Terminal Serial nos (without dashes) must be entered into the bridges setting file and configured to the correct terminal ID. The bridge service must be installed and running as a service. Once all this is completed the VX670 can be setup. Please see the instructions below.

Page 4 of 14

VX670 Set Up

Press F2 and F4 Function keys on the side of the screen at the same time to access the setup for the device. Screen displays

SYSTEM MODE ENTRY PASSWORD _________

Enter the Password Page 5 of 14

Press Green enter key.

SYS MODE MENU

1 RESTART F0

DOWNLOAD F1 RAM FILES F2 FLASH FILES F3 CONTRAST F4 CLOCK SET F5

Press the down button (second from left next to alpha key).

SYS MODE MENU

1 EDIT F1

PASSWORD F2 REMOTE F3 ERROR & TMPR LOGS F4 DEBUGGER F5

Press F1 to Edit the File Group containing the settings.

Page 6 of 14

SYS MODE FILE FILE GROUP _1

Press Enter

ENTER FILE GROUP 1 PASSWORD: __________

Enter the Password again and press enter.

Page 7 of 14

SYS MODE EDIT

G1

CLEAR CONFIG.SYS F1 CLEAR CONFIG.SYS WITH PROTECTED VAR F2 EDIT F3 EDIT VARIABLE F4

Press F3 to edit the parameters

SYS MODE EDIT FILE CONFIG.SYS_ ________ ________

G1

Press Enter

Page 8 of 14

SYS MODE EDIT KEY #HOSTIP _ _ _ _ _ _ _ ____________

G1

Press enter again to start editing.

SYS MODE EDIT

G1

#HOSTIP KEY F2 192.168.101 VALUE F3 .132

Parameters: (Use the two left hand buttons beneath the screen for up and down navigation through the parameters) To enter an alphabetical character press the corresponding key on the keypad and then press the alpha function key below the screen in the middle until it displays the correct letter. To enter special characters use the star or hash key together with the alpha key. To get a point/period use the 1 key. Red = Cancel Yellow = Delete/Backspace Green = Accept (Double Check everything) Page 9 of 14

ALWAYS PRESS F3 TO EDIT VALUES! NEVER F2 FOR THE KEY. Only change the parameters as indicated. All other values should be left as is unless otherwise specified. #HOSTIP Value should be the server on which the Table Pay Bridge is running or your Micros Server if the TPB is installed on it. Our example is 192.168.101.132

SYS MODE EDIT

G1

#HOSTIP KEY F2 192.168.101 VALUE F3 .132

Press the F3 key to edit the value and then delete the IP with the yellow key. Enter your server IP on which the Vx Bridge is running.

SYS MODE EDIT

G1

VALUE: _________________ _________________ _________________

Press enter when done.

Page 10 of 14

Press the down arrow once you have changed the value. This will take you to the next parameter.

SYS MODE EDIT

G1

#PORT KEY F2 8001 VALUE F3

These values are very important as it is used by the merchant and the bridge to talk to the Vx 670. Change this value if it is not 8001 or unless told to do so. Change your next parameter (MyIP) to a unique IP for the device. This IP need to be set up in the TR configurator as a new gateway for every Vx device you want to add to the network.

SYS MODE EDIT

G1

#MYIP KEY F2 192.168.101 VALUE F3 .5

Page 11 of 14

This gets generated by Concordes Back Office application and must be set up on the wireless AP as well. Otherwise the terminal will not be able to connect to the bridge software or do transactions. Values consist of letter A-F and numbers 0-9. DO NOT USE SMALL LETTERS.

SYS MODE EDIT

G1

#SSID KEY F2 738499DF2A123 VALUE F3 3E934B223D1230

Take not that the value displayed is not the full value. You must either edit the value or use the left and right keys to browse through the value.

SYS MODE EDIT

G1

#WEPMODE KEY F2 3 VALUE F3

The WEPMODE must be 3.

Page 12 of 14

SYS MODE EDIT

G1

#WEPMODE KEY F2 3 VALUE F3

The WPA Key is also generated by Concordes Back Office Application.

SYS MODE EDIT

G1

#WPAKEY KEY F2 31A3F2C5CC4D5EF6 VALUE F3 42F5D4D5F555D321

Press enter to make sure that the value has been accepted. Press cancel repeatedly until you are at the main setup screen. Press F0 to reboot the unit. If everything is setup correctly in the Merchant/Bridge and the VX Settings then you should be presented with a screen saying WELCOME which will change to CONCORDE Pay@Table Page 13 of 14

Press Enter after the unit has rebooted. If the unit does not display this after a minute, you are either out of range of the wireless AP or you have not configured everything properly. TRY AGAIN.

Page 14 of 14