Sei sulla pagina 1di 2

Control

71

GM CORCOM
Corrugated copper shielded multiconductor cable - 1.1KV - 70C.

See technical note on page 132.

Applications Suitable for high voltage substations and for variable frequency motor driving.

Specifications
Rated voltage: 600/1000 Volt a.c., 1200 Volt a.c. and 1800 Volt d.c. maximum. Service temperature: 70C maximum. Standards: Low voltage electrical installations, AEA Regulations, IEC 60364, IEC 79-14, suitable for 0-1-2 zone classified areas. EMC electromagnetic compatibility. Construction: IRAM 2178, IRAM 2268, IEC 60502-1, HN 33-S-34. Fire: Fire retardant, IRAM 2289 cat. C, IEC 60332-3 cat. C. EMC: Transfer impedance lower than 2 ohm/km up to 1MHz (according to IRAM 2268 and HN 33-S-34).

Description
Conductor: Annealed copper, Class 2. Insulation: PVC. Identification: White with numbers and letters printed in black. Shielding: longitudinal overlapped corrugated copper tape. Sheath: Fire retardant violet PVC.

Installation
Assembly: Minimum radius 12 x External Diameter. Maximum pulling tension on copper conductors: 5 daN/mm2.

Electric Characteristics
Nominal Cross-section mm2 Electric Resistance 20C in c.c. ohm/km Inductive Reactance 50 Hz ohm/km 2x Amp 3x Amp 4x Amp Current Capacities (*) 5x Amp 7x Amp 12x Amp 19x Amp 24x Amp 37x Amp

1.5 2.5 4

12.1 7.41 4.61

0.103 0.096 0.096

19 26 35

16 22 30

16 22 30

12 16.5 22.5

10.4 14.3 19.5

8.5 11.7 15.9

7.2 9.9 13.5

6.4 8.8 12

5.6 7.7 10.5

(*) In free air at 40C, according to IEC 364-5-523 and VDE 0298, Part 3. Nx - Number of conductors.

These specifications are intended for reference purposes only and can be modified without prior notice.

72

Control

GM CORCOM

Corrugated copper shielded multiconductor cable - 1.1KV - 70C.

Dimensions and Weight


Conductors Per cross-section N x mm2 Code Diameter mm Weight kg/km

2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 12x1,5 19x1,5 24x1,5 30x1,5 37x1,5

GM 0215 GM 0315 GM 0415 GM 0515 GM 0715 GM 1215 GM 1915 GM 2415 GM 3015 GM 3715

15.5 15.5 15.5 16.6 17.6 21.3 24.0 27.2 28.5 30.5

343 352 359 399 461 618 825 999 1159 1349

Conductors Per cross-section N x mm


2

Code

Diameter mm

Weight kg/km

2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 12x2,5 19x2,5 24x2,5 30x2,5 37x2,5

GM 0225 GM 0325 GM 0425 GM 0525 GM 0725 GM 1225 GM 1925 GM 2425 GM 3025 GM 3725

15.5 15.8 16.7 17.7 18.8 23.0 26.1 29.7 31.2 33.3

357 382 426 470 554 782 1061 1289 1530 1789

Conductors Per cross-section N x mm2 Code

Diameter mm

Weight kg/km

2x4 3x4 4x4 5x4 7x4 12x4 19x4

GM 0240 GM 0340 GM 0440 GM 0540 GM 0740 GM 1240 GM 1940

17.0 17.7 19.0 20.2 21.7 27.1 30.8

431 482 550 618 747 1102 1536

These specifications are intended for reference purposes only and can be modified without prior notice.

Potrebbero piacerti anche