Valve sensors from ifm electronic. The optimum solution for every requirement.
Fe
VD ed ba ck Fe
I/ of ed
VD tw o ba ck
38 va of
45 lv e th re e
po
si tio n va lv e
po
si tio n A Sic
s on
ne A
ct io n Sic on
ne
ct io n
3
Continuous position feedback on rising stem valves Positionfeedback on quarter-turn actuators
IND units combine two distinct inductive proximity sensors in a single, double insulated, IP 67 housing. One sensor provides a signal when the valve is open, the other when it is closed. The units are invaluable for confirming that power-operated
Robust housing:
IND type sensors incorporate two distinct inductive elements in a housing sealed to IP 67. The tough housing will also withstand impacts allowing their use in any application.
Connection opportunities:
Versions with integrated AS-i chips allow simple addition to AS-i networks, M12 cabled versions and units with a terminal chamber mean that ifms INDs are the simplest choice for valve control.
Unit with terminal chamber: Two captive screws above the cable gland enable easy opening and closing of the terminal chamber. The wiring can be maintained if the sensor is replaced, thanks to the removable terminal block. As an option, a solenoid valve can be triggered.
VDI / VDE 3845 is a guideline which defines, amongst other things, the mechanical mount-
Many accessories are available including target pucks for most valve actuators. The selector facilitates the selection of pucks for different quarter-turn actuators. www.ifm.com/gb/puck-selector
Namur IND units used with quarterturn valves installed on an oil tanker. Sensors with ATEX Cat. 1D/1G/2G were chosen because of the installation inside an explosive area.
By using state-of-the-art production technologies it has become possible to incorporate the latest AS-i technology with sensors and switching outputs in a space-saving housing. All these features facilitate mounting, set-up and maintenance for the user and increase uptime of the whole AS-Interface system.
and manual valves are in the appropriate position for correct and safe operation in all types of process plant.
ing arrangements for fitting switch boxes to actuators. The IND units have been specifically designed to conform to and take advantage of this guideline, allowing them to be fitted to the majority of actuators with the minimum of effort.
Requirement: Everywhere in the food industry valves are used for shutting off, monitoring and controlling. They are decisive components for the safety, accuracy and reliability of plants. Implementation: Conventionally, magnetic or induc- tive proximity switches assume this task. They signal end stops such as open or closed to the controller by means of a switch-ed signal.
AS-i integrated:
AS-Interface from ifm is the ideal way to communicate feedback from multiple valves and is incorporated, as standard, in the efector valvis.
Freely programmable:
With 3 switching outputs, the efector valvis gives reliable indication of the valve pistons position: open, closed or seat lift.
For a comprehensive selection of accessories and adapters for efector valvis see www.ifm.com.
Adapters:
Rising stem valves differ of course, so a range of adapters for many valve types, for example Alfa Laval, Sdmo, GEM and Georg Fischer, are available.
Easy position setup due to freely programmable switching outputs. They transmit the actual limits of travel to the controller.
However, the detection of intermediate positions is of increasing inter- est. It allows the detection of cleaning cycles for rising stem valves as well as the visualisation of unintended operating states by means of continuous valve detection. This is the only way to meet the growing requirements of modern process visualisation.
efector valvis was designed for feedback of the valve positions on rising stem valves with a stroke of up to 80 mm. The sensor is fitted over the valve spindle and continuously measures the stroke. This shows an installation on double seat valves, all three switching points are used.
With thanks to different adapters, efector valvis can be mounted on various valve types. In this case it is installed on an ON-OFF diaphragm valve. I.e. two switching points have to be set up. By missing the Seat position out, the sensor realises that only two switching points are needed.
System at a glance:
Inductive dual sensors
Type IND IND IND IND single solenoid IND terminal, double solenoid IND single solenoid IND double solenoid IND ATEX IND ATEX IND ATEX, single solenoid Operating voltage [V] 20...250 AC/DC 24 DC 24 DC 24 DC 24 DC AS-i AS-i 8.2 DC Namur 8.2 DC Namur 8.2 DC Namur Connection 2 m cable, 2 x 2 wires M12, 2 x 2 wires M12, 2 x 3 wires Rd24, M12 solenoid, 7 wires M20 + terminals, 7/8 wires M12, M12 solenoid, 2 wires M12, 2 x M12 solenoid, 2 wires M12, 2 x 2 wires M18, 2 x 2 wires Rd24, M12 solenoid, 6 wires + PE Order no IN0110 IN5331 IN5327 IN5334 IN5409 AC2316 AC2317 NN5008 NN5013 N95001
Inductive sensors
Type V3 microswitch style V3 microswitch style V3 microswitch style V3 microswitch style V3 microswitch style M12 body M18 body M30 body Operating voltage [V] 24 DC 24 DC 20...140 AC / 10...140 DC 8.2 V DC Namur 8.2 V DC Namur 24 DC 24 DC 24 DC Connection 2 m cable, 3 wires 2 m cable, 2 wires 2 m cable, 2 wires 2 m cable, 2 wires 0.098 m cable, 2 wires M12, 3 wires M12, 3 wires M12, 3 wires Order no IS5001 IS5026 IS0003 NS5002 NS5009 IFT240 IGT247 IIT228
Inductive sensors IF, IG, II and IS type Position feedback on rising stem valves or inside switchboxes.
Robust:
Tried and tested for extreme requirements in hygienic and wet areas such as permanently high temperatures, temperature shocks or aggressive cleaning agents.
Food-grade:
Housing materials such as stainless steel in combination with PEEK or pure stainless steel sensors.
The sensors undergo a hard test program of temperature cycle, steam boiler, vibration, shock and temperature This procedure guarantees the highest operational reliability for any conditons in the food industry.
Flexible:
Common housing types and lengths for installation in different applications. Increased sensing ranges ensure flexible installation for mechanical tolerances.
Ingress-resistant:
The ingress resistance to protection rating IP 69K prevents moisture penetration.
The common valve boxes can be used with the square-shaped sensors of type IS. Customer-specific versions such as platinum connectors facilitate installation.
Safe connection:
ecolink EVT the ideal connector for hygienic and wet areas: PVC cables and housings plus stainless steel coupling nuts provide protection to IP 69K.
Position sensors
Industrial imaging
ifm article no. 7511507 We reserve the right to make technical alterations without prior notice. Printed in Germany on non-chlorine bleached paper. 09/12
Safety technology
Process sensors
Industrial communication
Identification systems
Connection technology
Accessories