Sei sulla pagina 1di 10

Feedback systems for valves and valve actuators.

Position sensors www.ifm.com/gb/valve-control

102

For industrial applications

Valve sensors from ifm electronic. The optimum solution for every requirement.

Inductive dual sensors IND type

Position feedback on quarter-turn actuators

Feedback system efector valvis IX type

Continuous position feedback on rising stem valves

Inductive sensors IF, IG, II and IS type

Position feedback on rising stem valves or inside switchboxes

Fe

VD ed ba ck Fe

I/ of ed

VD tw o ba ck

38 va of

45 lv e th re e

po

si tio n va lv e

po

si tio n A Sic

s on

ne A

ct io n Sic on

ne

ct io n

3
Continuous position feedback on rising stem valves Positionfeedback on quarter-turn actuators

Positionfeedback on rising stem valves or inside switchboxes

Dual sensor IND type

IND units combine two distinct inductive proximity sensors in a single, double insulated, IP 67 housing. One sensor provides a signal when the valve is open, the other when it is closed. The units are invaluable for confirming that power-operated

Clearly visible position indicators:


LEDs indicate current position and switching status as well as markings located on the target puck.

Robust housing:
IND type sensors incorporate two distinct inductive elements in a housing sealed to IP 67. The tough housing will also withstand impacts allowing their use in any application.

Compatible with VDI / VDE 3845:


All IND sensors are compatible with VDI / VDE 3845 guidelines meaning they are simple to fit to nearly any actuator.

Connection opportunities:
Versions with integrated AS-i chips allow simple addition to AS-i networks, M12 cabled versions and units with a terminal chamber mean that ifms INDs are the simplest choice for valve control.

Unit with terminal chamber: Two captive screws above the cable gland enable easy opening and closing of the terminal chamber. The wiring can be maintained if the sensor is replaced, thanks to the removable terminal block. As an option, a solenoid valve can be triggered.

Position feedback on quarter-turn actuators.

VDI / VDE 3845 is a guideline which defines, amongst other things, the mechanical mount-

Many accessories are available including target pucks for most valve actuators. The selector facilitates the selection of pucks for different quarter-turn actuators. www.ifm.com/gb/puck-selector

Namur IND units used with quarterturn valves installed on an oil tanker. Sensors with ATEX Cat. 1D/1G/2G were chosen because of the installation inside an explosive area.

Positionfeedback on rising stem valves or inside switchboxes

By using state-of-the-art production technologies it has become possible to incorporate the latest AS-i technology with sensors and switching outputs in a space-saving housing. All these features facilitate mounting, set-up and maintenance for the user and increase uptime of the whole AS-Interface system.

Continuous position feedback on rising stem valves

Positionfeedback on quarter-turn actuators

and manual valves are in the appropriate position for correct and safe operation in all types of process plant.

ing arrangements for fitting switch boxes to actuators. The IND units have been specifically designed to conform to and take advantage of this guideline, allowing them to be fitted to the majority of actuators with the minimum of effort.

Feedback system efector valvis IX type

Requirement: Everywhere in the food industry valves are used for shutting off, monitoring and controlling. They are decisive components for the safety, accuracy and reliability of plants. Implementation: Conventionally, magnetic or induc- tive proximity switches assume this task. They signal end stops such as open or closed to the controller by means of a switch-ed signal.

AS-i integrated:
AS-Interface from ifm is the ideal way to communicate feedback from multiple valves and is incorporated, as standard, in the efector valvis.

Freely programmable:
With 3 switching outputs, the efector valvis gives reliable indication of the valve pistons position: open, closed or seat lift.

For a comprehensive selection of accessories and adapters for efector valvis see www.ifm.com.

Simple set up:


Uncomplicated programming by pushing a button replaces mechanical adjustment to the respective valve positions.

Adapters:
Rising stem valves differ of course, so a range of adapters for many valve types, for example Alfa Laval, Sdmo, GEM and Georg Fischer, are available.

Easy position setup due to freely programmable switching outputs. They transmit the actual limits of travel to the controller.

Continuous position feedback on single, double seat and diaphragm valves.

However, the detection of intermediate positions is of increasing inter- est. It allows the detection of cleaning cycles for rising stem valves as well as the visualisation of unintended operating states by means of continuous valve detection. This is the only way to meet the growing requirements of modern process visualisation.

efector valvis was designed for feedback of the valve positions on rising stem valves with a stroke of up to 80 mm. The sensor is fitted over the valve spindle and continuously measures the stroke. This shows an installation on double seat valves, all three switching points are used.

Product information efector valvis www.ifm.com/gb/valvis

Positionfeedback on rising stem valves or inside switchboxes

With thanks to different adapters, efector valvis can be mounted on various valve types. In this case it is installed on an ON-OFF diaphragm valve. I.e. two switching points have to be set up. By missing the Seat position out, the sensor realises that only two switching points are needed.

Continuous position feedback on rising stem valves

Positionfeedback on quarter-turn actuators

System at a glance:
Inductive dual sensors
Type IND IND IND IND single solenoid IND terminal, double solenoid IND single solenoid IND double solenoid IND ATEX IND ATEX IND ATEX, single solenoid Operating voltage [V] 20...250 AC/DC 24 DC 24 DC 24 DC 24 DC AS-i AS-i 8.2 DC Namur 8.2 DC Namur 8.2 DC Namur Connection 2 m cable, 2 x 2 wires M12, 2 x 2 wires M12, 2 x 3 wires Rd24, M12 solenoid, 7 wires M20 + terminals, 7/8 wires M12, M12 solenoid, 2 wires M12, 2 x M12 solenoid, 2 wires M12, 2 x 2 wires M18, 2 x 2 wires Rd24, M12 solenoid, 6 wires + PE Order no IN0110 IN5331 IN5327 IN5334 IN5409 AC2316 AC2317 NN5008 NN5013 N95001

Target pucks and accessories


Description Target puck, 53 mm Target puck, 53 mm, 8 switching flag positions Target puck, 65 mm, Target puck, 102 mm, Cable gland, M20 x 1.5 Protective cap, M20 x 1.5 Plug for covering the oblong holes Reinforcement bracket Flat cable connector Order no E10661 E17321 E17327 E17328 E12208 E12209 E12212 E11310 E70096

Feedback system efector valvis


Type IX IX IX Operating voltage [V] 24 DC binary AS-i 1...5 analogue Connection 0.3 m Pigtail M12, 5 wires 0.3 m Pigtail M12, 2 wires 2 m cable, 3 wires Order no IX5010 IX5030 IX5002

Accessories mounting adapter


Description for Alfa Laval valves for Sdmo valves for Bardiani valves IX / 30 mm, for Gem actuators IX / 45 mm, for Gem actuators Order no E11900 E11989 E12170 E12042 E12043

Inductive sensors
Type V3 microswitch style V3 microswitch style V3 microswitch style V3 microswitch style V3 microswitch style M12 body M18 body M30 body Operating voltage [V] 24 DC 24 DC 20...140 AC / 10...140 DC 8.2 V DC Namur 8.2 V DC Namur 24 DC 24 DC 24 DC Connection 2 m cable, 3 wires 2 m cable, 2 wires 2 m cable, 2 wires 2 m cable, 2 wires 0.098 m cable, 2 wires M12, 3 wires M12, 3 wires M12, 3 wires Order no IS5001 IS5026 IS0003 NS5002 NS5009 IFT240 IGT247 IIT228

Inductive sensors IF, IG, II and IS type Position feedback on rising stem valves or inside switchboxes.

Robust:
Tried and tested for extreme requirements in hygienic and wet areas such as permanently high temperatures, temperature shocks or aggressive cleaning agents.

Food-grade:
Housing materials such as stainless steel in combination with PEEK or pure stainless steel sensors.
The sensors undergo a hard test program of temperature cycle, steam boiler, vibration, shock and temperature This procedure guarantees the highest operational reliability for any conditons in the food industry.

Flexible:
Common housing types and lengths for installation in different applications. Increased sensing ranges ensure flexible installation for mechanical tolerances.

Ingress-resistant:
The ingress resistance to protection rating IP 69K prevents moisture penetration.
The common valve boxes can be used with the square-shaped sensors of type IS. Customer-specific versions such as platinum connectors facilitate installation.

Safe connection:
ecolink EVT the ideal connector for hygienic and wet areas: PVC cables and housings plus stainless steel coupling nuts provide protection to IP 69K.

Positionfeedback on rising stem valves or inside switchboxes

Continuous position feedback on rising stem valves

Positionfeedback on quarter-turn actuators

Visit our website: www.ifm.com

Overview ifm product range:

Over 70 locations worldwide at a glance at www.ifm.com


ifm electronic gmbh Friedrichstrae 1 45128 Essen Tel. +49 / 201 / 24 22-0 Fax +49 / 201 / 24 22-1200 E-mail info@ifm.com

Position sensors

Sensors for motion control

Industrial imaging
ifm article no. 7511507 We reserve the right to make technical alterations without prior notice. Printed in Germany on non-chlorine bleached paper. 09/12

Safety technology

Process sensors

Industrial communication

Identification systems

Condition monitoring systems

Systems for mobile machines

Connection technology

Accessories

Potrebbero piacerti anche