Sei sulla pagina 1di 2

Micropilot M

FMR244: Level Measurement in Silo Filled with Lime Stone Grain

The silo

Lime stone grain

Installed device

Customer Profile: The customer started his long and successful tradition in the 1870s in southern Germany and has now a leading position in the fields of concrete, cement and other downstream activities in more than fifty countries. Application description:

Application challenges: The Micropilot M has to cope with the very dusty conditions and the very strong angle of repose. Instrument used: Micropilot M FMR244-A4SXXG4A2F (with 35dB module) Measurement results:

Instrument description: The Micropilot M FMR244 is a compact radar level transmitter for the continuous, contactless measurement of liquids, pastes and sludge. It has an operating frequency of about 26GHz and a maximum radiated pulsed energy of 1mW. Antenna (housing) temperature range: -40..80C (-40..80C) Pressure range: -1..3 bar For solid applications: option F with 35dB module For media with DC 1.4..>10 (both non-conductive and conductive) Totally harmless for human and animals

The FMR244 measures the level in a cylindrical upright buffer silo with a conical outlet. The silo gets filled with lime stone grain from the top via a conveyor belt. This creates a very dusty atmosphere and a very strong angle of repose. The silo is 11m high and has a diameter of 6m. The lime stone has a grain size of less then 10mm and a dielectric constant greater then 1.8. The device is installed in a 775mm x 775mm manhole.

During the field test period of 6 months the Micropilot M FMR244 worked without any problem and the customer is very satisfied. A general recommendation for solid applications is the 35dB module.

Benefits for the customer: Simple and reliable measurement. Easy installation of the device There is no contact between the device and the medium, thus there is no wear and tear

CS1964_FMR244_en

Comparison of the measured values (FMU90 vs. FMR244):

Shut down of the FMR 244 device during investigation! Fluctuating measured value with Standard settings (slow filling) Larger integration time is recommended!

FMU90 (reference) FMR244

Green: FMU90 (reference); Red: FMR244 FMR244 with 70m hf-module is showing the same results like the reference device.

Envelope curve during standard operation:

Germany Endress+Hauser GmbH+Co. KG Hauptstrasse 1 79689 Maulburg Germany Phone: +49 7622 28-0 Fax: +49 7622 28-14 38 info@pcm.endress.com www.endress.com

CS1964_FMR244_en