Sei sulla pagina 1di 36

NCRRealPOS82XRT(7606)

Release1.1

SitePreparationGuide

B00500002086
IssueB

TheproductdescribedinthisbookisalicensedproductofNCRCorporation.
NCRisaregisteredtrademarkofNCRCorporation.NCRRealPOSisatrademarkofNCRCorporationintheUnitedStatesand/or
othercountries.Otherproductnamesmentionedinthispublicationmaybetrademarksorregisteredtrademarksoftheir
respectivecompaniesandareherebyacknowledged.
Wherecreationofderivativeworks,modificationsorcopiesofthisNCRcopyrighteddocumentationispermittedundertheterms
andconditionsofanagreementyouhavewithNCR,NCRscopyrightnoticemustbeincluded.
ItisthepolicyofNCRCorporation(NCR)toimproveproductsasnewtechnology,components,software,andfirmwarebecome
available.NCR,therefore,reservestherighttochangespecificationswithoutpriornotice.
Allfeatures,functions,andoperationsdescribedhereinmaynotbemarketedbyNCRinallpartsoftheworld.Insomeinstances,
photographsareofequipmentprototypes.Therefore,beforeusingthisdocument,consultwithyourNCRrepresentativeorNCR
officeforinformationthatisapplicableandcurrent.
Tomaintainthequalityofourpublications,weneedyourcommentsontheaccuracy,clarity,organization,andvalueofthisbook.
Addresscorrespondenceto:
Manager,InformationSolutionsGroup
NCRCorporation
DiscoveryCentre,3FultonRoad
Dundee,DD24SW
Scotland
InternetAddress:

http://www.info.ncr.com/eFeedback.cfm
Copyright2011
ByNCRCorporation
Duluth,GAU.S.A.
AllRightsReserved

iii

Preface
Thisisacontractualdocument.Itcontainsimportantwarningsandconfersimportant
legalrightsandobligations.Youareadvisedtoreaditcarefully.
Itistheresponsibilityofthecustomertoensurethatallinstallationpreparationsare
completeandincompliancewithNCRspecificationsandrequirementsandall
applicablenational,state,orlocalcodes,regulations,andlaws.
Notice:ThisdocumentisNCRproprietaryinformationandisnottobedisclosedor
reproducedwithoutconsent.

Safety Requirements
TheNCRRealPOS82XRTconformstoallapplicablelegalrequirements.Toviewthe
compliancestatementsseetheNCRRealPOSTerminalsSafetyandRegulatoryStatements
(B00500001589).
Theon/offswitchisalogicswitchonly.TheAClinevoltageprimariesareliveatall
timeswhenthepowercordisconnected.Therefore,disconnecttheACpowercord
beforeopeningtheunittoinstallfeaturesorservicethisterminal.

Peripheral Usage
Thisterminalshouldonlybeusedwithperipheraldevicesthatarecertifiedbythe
appropriatesafetyagencyforthecountryofinstallation(UL,CSA,TUV,VDE)orthose
whicharerecommendedbyNCRCorporation.

References

NCRRealPOS82XRTUserGuide(B00500002085)

NCRRealPOS82XRTHardwareServiceManual(B00500002087)

NCRRealPOS82XRTPartsIdentificationManual(B00500002088)

Revision Record
Issue

Date

Remarks

Mar 2012

First Issue

Aug 2012

Release 1.1

iv

About this Book


ThisbookprovidessitepreparationinformationforNCRRealPOS82XRTcomponents.
ThisbookdoesNOTprovidePeripheralcomponentandACwiringsitepreparation
information.AlistoftheassociatedreferencedocumentsisintheRelatedSite
PreparationDatasection.
Thisbookcontainstheinformationnecessaryforthepreparationofasiteconforming
totheNCRspecifications.Itisveryimportantthatthesitecomplieswiththe
requirementsspecifiedinthedocumentbecause,oncetheequipmenthasbeen
installed,deficienciesinsitepreparationortheproblemscausedbythesedeficiencies
aremuchmoredifficulttodetectandcorrect.Further,failuretocomplywiththese
requirementsortotakeproperstepstoprotectequipmentagainstrisksidentifiedin
thisdocumentmaycauseseriousdamagetotheequipmentandtothecustomers
business.
Inadditiontotheneedtocomplywiththerequirementsspecified,electricalwiring
andmechanicalsystemsmustalsocomplywithallrelevantcodes,laws,and
regulations.
Itisimportantthatacustomerorhisagentwhoisfullyconversantwiththespecial
requirementsofelectronicequipmentpreparethesite.Theresponsibilityofensuring
thatthesiteispreparedincompliancewiththisdocumentremainswiththecustomer.
Forinformationandguidancepurposesonly,alistisprovided,ingeneralterms,of
thosemattersforwhichthecustomerisresponsible.Thislistdoesnotintendtobe
comprehensive,andinnowaymodifies,alters,orlimitstheresponsibilityofthe
customerforallaspectsofadequatesitepreparation.
NCRstaffisavailabletoanswerquestionsrelatingtothecontentsofthisdocument
exceptwhere:

acustomerhasbeennotifiedthatafullorpartialconsultancyserviceisavailable
and/orthatNCRiswillingtoundertakeapreliminaryorfinalsitesurveyand

thecustomershallhaveenteredintoaformalcontractwithNCRforprovisionof
thesame.

Nocomment,suggestion,oradviceofferedornotofferedaboutpreparationofthesite
noranyinspectionofthesitewhetherbeforeorafterpreparationistobetakenas
approvalofthelocationofthesiteandequipmentoritspreparationandNCRisnot
liableinrespectofanycomment,suggestion,oradvicegivenbyitsstafforinrespectto
anyfailuretogiveadvice.
Finally,onlythecustomercanknowthefullextentofdamage,whichmaybecausedto
hisbusinessbecauseoffailureoftheequipmentthatistobeinstalled.Forthisreason,
itisthecustomersresponsibilitytoascertaintheextentofanypossibledamagetohis
existingorplannedbusiness,andtoeffectfullinsuranceinrespectofit.

Table of Contents
Chapter1:NCRRealPOS82XRTTerminalSitePreparation
Introduction................................................ 11
ModelNumbers ......................................... 12
CustomerResponsibilities.................................... 13
ThirdPartyPeripheralCertification ........................... 14
LANCommunications....................................... 14
Dimensions ................................................ 15
BaseUnit............................................... 15
IntegratedTerminal ...................................... 15
IntegratedTerminalw/CashDrawer ....................... 16
7459K320VerticalMount................................. 17
595415InchDynaKey.................................... 18
StandardRemoteTableTopMount(5964K030/K031) ..... 18
NCR5964K038/K039CheckstandMount ................ 19
NCR594212.1InchLCD ................................ 110
NCR594312InchLCD .................................. 110
NCR596412InchTouchLCD ............................ 111
StandardRemoteTableTopMount(5964K031/032) ..... 111
NCR596615InchTouchLCD ............................ 112
NCR5966withTableTopMount ..................... 112
NCR5966with5964K030/K031TableTopMount....... 112
NCR59826.5InchColorLCD ............................ 113
CustomerDisplays...................................... 114
NCR59751xxx2x20RemoteCustomerDisplay ............ 114
NCR59752xxxGraphicalRemoteCustomerDisplay ........ 115
NCR59761xxx2x20RemoteCustomerDisplay ............ 116
Keyboards ............................................. 117
NCR59322xxx64KeyPOSKeyboard ................. 117
NCR59325xxxUSBBigTicketPOSKeyboard .......... 117
NCR59326xxx104KeyCompactAlphanumericKeyboard118
NCR59327xxxPS/278KeyPOSKeyboard ............. 118
NCR7459K317/K318KeyboardFillerPlate ............. 118
Printers................................................ 119
NCR7167ThermalReceiptandImpactSlipPrinter...... 119
NCR7168ThermalReceiptandImpactSlipPrinter...... 119
NCR7197ThermalReceiptPrinter..................... 120
NCR7198ThermalReceiptPrinter..................... 120
NCR7162MultifunctionImpactPrinter ................ 121

vi

CashDrawers.......................................... 122
NCR2181CashDrawer.............................. 122
NCR2185FlipTopDrawer........................... 122
NCR2186CompactCashDrawer...................... 123
EnvironmentalRequirements ................................ 124
BarometricPressure ..................................... 124
Temperature........................................... 124
Humidity .............................................. 124
ElectricalRequirements ..................................... 125
7606TerminalPowerRequirements ....................... 125
PeripheralPowerRequirements .......................... 125
ACStoreWiringRequirements ........................... 125
TComponentWeights ...................................... 126
ShippingWeightEstimate ............................... 127
ServiceClearanceRequirements ............................. 127
AirflowRequirements...................................... 128
AppendixA:TransientProtection

NCR RealPOS 82XRT Terminal Site Preparation


Introduction
ThisdocumentprovidestheinformationnecessarytoprepareasitetoNCR
specificationspriortoinstallinganNCRRealPOS82XRTTerminal(alsoreferredtoas
theNCR7606).Preparethesiteproperlybeforeinstallingtheterminalbecausesite
preparationdeficienciesmaybedifficulttodetectandcorrectafterinstallation.
TheNCR7606consistsofseparatepiecesthatmaybecombinedinavarietyof
configurations.Certaincombinationsaremutuallyexclusive.Youmustdeterminethe
equipmentthatwillactuallybeinstalledbeforeproceedingwiththesitepreparation.

NCR RealPOS 82XRT Terminal Site Preparation

Model Numbers
Major Model

CPU

76061002

IntelCeleronG540,2.5GHz,2GBDDR31033MHzmemory,Diskless,
80PlusGoldPowerSupply,USpowercordonly,Beige

76061007

IntelCeleronG540,2.5GHz,2GBDDR31033MHzmemory,Diskless,
80PlusGoldPowerSupply,USpowercordonly,Charcoal

76061110

IntelCeleronG540,2.5GHz,2GBDDR31033MHzmemory,Diskless,
UPSReady,Beige

76061302

IntelPentiumG850,2.9GHz,2GBDDR31033MHzmemory,Diskless,
80PlusGoldPowerSupply,Beige

76061307

IntelPentiumG850,2.9GHz,2GBDDR31033MHzmemory,Diskless,
80PlusGoldPowerSupply,Beige

76061507

IntelCorei32120,3.3GHz,2GBDDR31033MHzmemory,Diskless,
80PlusGoldPowerSupply,Charcoal

76061707

IntelCorei52400,3.1GHz,2GBDDR31033MHzmemory,Diskless,
80PlusGoldPowerSupply,Charcoal

NCR RealPOS 82XRT Terminal Site Preparation

Customer Responsibilities
Beforeinstallingthesystem,thecustomermustperformorprovidethefollowing:

WhenrequiredbyNCR,providetheNCRCustomerServicesrepresentativewith
appropriatedrawingsthatindicate:

Equipmentlocation

Sitewiring(powerandcommunications,pathsandlengths)

Locationofotherequipmentthatmaygenerateelectricalnoise,electromagnetic
interference,orheat

Makebuildingalterationsnecessarytomeetwiringandothersiterequirements

Provideandinstallallcommunicationscables,walljacks,specialconnectors,and
associatedhardware

Provideandinstallnecessarypowerdistributionboxes,conduits,grounds,
lightningprotectiondevices,andassociatedhardware

Ensureallapplicablecodes,regulations,andlaws(including,butnotlimitedto,
electrical,building,safety,andhealth)aremet

Provideandinstallauxiliarypowerorotherequipmentasrequired

Providestorageorserviceareasasrequired

Meetallsystem/unitenvironmentalrequirements

Provideandinstallfloorcoveringsandenvironmentsystemsthatlimitorcontrol
staticelectricitybuildupanddischarge

Ingeneral,keeptheNCRequipmentareafreefromdust,smoke,lint,andother
particles.Restrictsmoking,eating,anddrinkingaroundtheequipment.Avoid
locatingtheequipmentnearothermachinesthatgenerateink,carbon,andpaperdust
particles.

NCR RealPOS 82XRT Terminal Site Preparation

Third Party Peripheral Certification


ThirdpartyperipheralsmustbecertifiedwiththePOSterminalorapotentialESD
issuecanoccur.Thirdpartyperipheralsincludeanyelectricallypowereddevices
connectedtothePOSterminalthatisnotanNCRbrandedproductoracertified
solutionadvocatedbyNCR.Examplesofthirdpartyproductsincludeprinters,
externalCDROMdrives,cashdrawers,cigaretteboxes,pinpaddevices,etc.
Peripheralstendtobelesssensitivetoelectrostaticdamagewhendirectlygrounded
throughtheirpowercords.Iftheperipheralispoweredbytheterminalandhasno
dedicatedground,thenalloftheESDenergyiscoupledintotheportconnection.
Somedevicesmayrequiretheuseofaninlinegalvanicisolator/surgeprotectorin
ordertopreventproblems.
TheNCRTPP/SCERprocessisdesignedtoevaluatethirdpartyperipheralsand
determinewhetheradditionalprotectivedevicesareneeded.
TheNCRWorkstationandPeripheralsACWiringGuide(BST0211553)contains
additionalinformationonthissubject.

LAN Communications
TheNCR7606TerminalsupportsEthernet10/100/1000baseTLocalAreaNetwork
(LAN)communicationprotocol.ForEthernetcommunicationswiringspecifications,
refertotheNCREthernetCommunicationWiringGuide(BST0211882).

NCR RealPOS 82XRT Terminal Site Preparation

Dimensions
Base Unit

115 mm
(4.5 in.)

394 mm
(15.5 in.)

340 mm
(13.4 in.)

30597

Integrated Terminal

472 mm
(18.6 in.)

442 mm
(17.4 in.)

500 mm
(19.7 in.)

Dimension

5964 (12)

5954 (15)

5965 (15)

5943 (12)

508 mm
(20.0 in.)

500 mm
(19.7 in.)

570 mm
(22.4 in.)

525 mm
(20.7 in.)

612 mm
(24.1 in.)

673 mm
(26.5 in.)

630 mm
(24.8 in.)

608 mm
(23.9 in.)
30598

NCR RealPOS 82XRT Terminal Site Preparation

Integrated Terminal w/Cash Drawer

472 mm
(18.6 in.)

442 mm
(17.4 in.)

500 mm
(19.7 in.)

Dimension

5964 (12)

5954 (15)

5965 (15)

5943 (12)

622 mm
(24.5 in.)

673 mm
(24.2 in.)

690 mm
(27.2 in.)

645 mm
(25.4 in.)

612 mm
(24.1 in.)

673 mm
(26.5 in.)

630 mm
(24.8 in.)

608 mm
(23.9 in.)
30599

NCR RealPOS 82XRT Terminal Site Preparation

7459-K320 Vertical Mount

386 mm
(15.2 in.)

198 mm
(7.8 in.)

378 mm
(14.9 in.)

30620

NCR RealPOS 82XRT Terminal Site Preparation

5954 15-Inch DynaKey


Standard Remote Table Top Mount (5964-K030/K031)

495 mm
(19.5 in.)

335 mm
(13.2 in.)

DynaKey w/o MSR

295 mm
(11.6 in.)

507 mm
(20.0 in.)

DynaKey w/MSR

23875a

NCR RealPOS 82XRT Terminal Site Preparation

NCR 5964-K038/K039 Checkstand Mount


TheCheckstandMountisfullyadjustablebetweentheminimumandmaximum
dimensionsthatareillustratedbelow.TheDynaKeycanalsoberotatedrightandleft
ofcenter(shown)byapproximately90degrees,aswellastiltedfromavertical
positiontoapproximately45degrees(shown).

114 mm
4.25 in.

370 mm
(14.5 in.)

38 mm
1.5 in.

89 mm
3.5 in.

70 mm
2.75 in.

7.6.mm
0.30 in.
330 mm
(13.0 in.)

480 mm
(19.0 in.)

216 mm
(8.5 in.)

400 mm
(15.75 in.)

213 mm
(8.4 in.)

19909b

10

NCR RealPOS 82XRT Terminal Site Preparation

NCR 5942 12.1-Inch LCD


306 mm
(12.0 in.)

304 mm
(11.9 in.)

47 mm
(1.9 in.)
133 mm
(5.25 in.)
165 mm
(6.5 in.)

190 mm
(7.5 in.)

13 mm
(0.5 in.)

19810b

NCR 5943 12-Inch LCD

292 mm
(11.5 in.)

229 mm
(9.0 in.)
292 mm
(11.5 in.)
329 mm
(12.9 in.)

254 mm
(10.0 in.)
280 mm
(11.0 in.)

NCR RealPOS 82XRT Terminal Site Preparation

11

NCR 5964 12-Inch Touch LCD


Standard Remote Table Top Mount (5964-K031/032)

21209a

12

NCR RealPOS 82XRT Terminal Site Preparation

NCR 5966 15-Inch Touch LCD


NCR 5966 with Table Top Mount

400 mm
(15.7 in.)

220 mm
(8.7 in.)

180 mm
(7.1 in.)

358 mm
(14.1 in.)

220 mm
(8.7 in.)

394 mm
(15.5 in.)

27328

NCR 5966 with 5964-K030/K031 Table Top Mount

400 mm
(15.7 in.)

230 mm
(9.0 in.)
358 mm
(14.1 in.)

394 mm
(15.5 in.)

254 mm
(10.0 in.)
220 mm
(8.7 in.)

27327

NCR RealPOS 82XRT Terminal Site Preparation

NCR 5982 6.5-Inch Color LCD

174 mm
(6.9 in.)

192 mm
(7.6 in.)

140 mm
(5.5 in.)

140 mm
(5.5 in.)

23158

13

14

NCR RealPOS 82XRT Terminal Site Preparation

Customer Displays
NCR 5975-1xxx 2x20 Remote Customer Display

180 mm
(7.1 in.)

81 mm
(3.2 in.)

216 mm
(8.5 in.)

151 mm
(5.9 in.)

123 mm
(4.8 in.)

22915

NCR RealPOS 82XRT Terminal Site Preparation

NCR 5975-2xxx Graphical Remote Customer Display

224 mm
(8.9 in.)

93 mm
(3.7 in.)

229 mm
(9.0 in.)

151 mm
(5.9 in.)

123 mm
(4.8 in.)
22916

15

16

NCR RealPOS 82XRT Terminal Site Preparation

NCR 5976-1xxx 2x20 Remote Customer Display

159 mm
(6.6 in.)

80 mm
(3.2 in.)

211 mm
(8.3 in.)

153 mm
(6.0 in.)

123 mm
(4.8 in.)

30824

NCR RealPOS 82XRT Terminal Site Preparation

Keyboards
NCR 5932-2xxx 64-Key POS Keyboard

184 mm
(7.2 in.)

335 mm
(13.2 in.)

42 mm
(1.7 in.)

11413a

NCR 5932-5xxx USB Big Ticket POS Keyboard

184 mm
(7.2 in.)

455 mm
(17.9 in.)

42 mm
(1.7 in.)

19716a

17

18

NCR RealPOS 82XRT Terminal Site Preparation

NCR 5932-6xxx 104-Key Compact Alphanumeric Keyboard

184 mm
(7.25 in.)

365 mm
(14.4 in.)
45 mm
(1.7 in.)
21317a

NCR 5932-7xxx PS/2 78-Key POS Keyboard

47 mm
(1.9 in.)
188 mm
(7.4 in.)

283 mm
(11.1 in.)
22049a

NCR 7459-K317/K318 Keyboard Filler Plate

432 mm
(17 in.)

185 mm
(7.3 in.)
25207

NCR RealPOS 82XRT Terminal Site Preparation

Printers
NCR 7167 Thermal Receipt and Impact Slip Printer

174 mm
(7.0 in.)

262 mm
(10.3 in.)

275 mm
10.8 in.

190 mm
(7.5 in.)

316 mm
(12.5 in.)

19711g

NCR 7168 Thermal Receipt and Impact Slip Printer

181 mm
(7.1 in.)
OK

346 mm
(13.6 in.)

190 mm
(7.5 in.)

300 mm
(11.8 in.)

23537a

19

20

NCR RealPOS 82XRT Terminal Site Preparation

NCR 7197 Thermal Receipt Printer

156 mm
(6.25 in.)

184 mm
(7.25 in.)

255 mm
10.1 in.

146 mm
(5.75 in.)
19712g

NCR 7198 Thermal Receipt Printer

139 mm
(5.5 in.)

220 mm
(8.7 in.)

256 mm
(10.1 in.)

145 mm
(5.7 in.)
23834c

NCR RealPOS 82XRT Terminal Site Preparation

NCR 7162 Multifunction Impact Printer

191 mm
(7.5 in.)

142 mm
(5.6 in.)

250 mm
(11.7 in.)

297 mm
(11.7 in.)

15410a

21

22

NCR RealPOS 82XRT Terminal Site Preparation

Cash Drawers
NCR 2181 Cash Drawer

442 mm
(17.4 in.)

117 mm
(4.6 in.)
w/feet:

127 mm
(5.0 in.)

467 mm
(18.7 in.)

762 mm
(30.0 in.)

24799

NCR 2185 Flip Top Drawer

254 mm
10.0 in.

460 mm
18.1 in.
172 mm
6.8 in.

23535

NCR RealPOS 82XRT Terminal Site Preparation

NCR 2186 Compact Cash Drawer

411 mm
(16.2 in.)

110 mm
(4.3 in.)
415 mm
(16.3 in.)

700 mm
(27.6 in.)

23150a

23

24

NCR RealPOS 82XRT Terminal Site Preparation

Environmental Requirements
Barometric Pressure
Theterminaloperateswithinthefollowingbarometricpressureconditions:

Maximumoperatingaltitude:3,000m(9,843ft.)

Operatingrangeofpressure:105to69kPa(15.2to10.0lb./in.)

Temperature
Theterminaloperatesoverthetemperaturerangesshownbelow.Avoidcontinuous
operationat,neartheindicatedtemperatureextremes,orinlocationswherethe
temperaturechangesbeyondtherestrictions.
Temperature Parameter

Restriction

Operating

5Cto40C(41Fto104F),drybulb

Storage

10Cto50C(14Fto122F),threemonths

Shipping

40Cto60C(40Fto140F),oneweek

Humidity
Theterminaloperateswithinthehumidityrangesshownbelow.Avoidcontinuous
operationat,neartheindicatedhumidityextremes,orinlocationswherethe
humiditychangesbeyondtherestrictions.Neverexposetheterminalto
condensation.
Humidity Type

Restriction

Relative

10%to90%

Maximumchangerate

10%/60minutes

Storage

10%to90%relativehumidity,threemonths

Shipping

5%to95%relativehumidity,oneweek

NCR RealPOS 82XRT Terminal Site Preparation

25

Electrical Requirements
7606 Terminal Power Requirements
Theterminalsexternalpowersupplyhasamaximumoutputof150Wattsand
providespowertotheterminalanditspoweredperipherals.
Range

Nominal Vrms

Minimum Vrms

Maximum Vrms

LOW(115)

100127

90

136

HIGH(230)

200240

180

265

Caution: Locatethepowersupplyawayfromotherelectricalequipment,awayfrom
heatsources,awayfrompossibleliquidspills,andwherethereisadequateclearance
forcooling.
Note: TheRealPOS82XRTdoesnotofferanACconvenienceoutletforCRTpower.A
separatecountryspecificpowercordmustbeorderedseparately.AvailableNCR
powercordsaredescribedintheSystemCablessection.

Peripheral Power Requirements


Thenumberofperipheralsthattheterminalcansupportisdependentuponwhich
peripheralsareconnected.Forplanningpurposes,usetheRealPOS82XRT(7606)
Release1.0PowerMatrix(B00500002089)fordetailsontotalpowerdistribution.
Note: ThisfilerequiresMicrosoftExceltorun.

AC Store Wiring Requirements


ThecustomermustprovidesuitableACpowerfortheterminals,associated
equipment,anddevices.Werecommendadedicatedunswitchedpowerline
dedicatedtotheNCRequipmentinstallation.RefertotheNCRWorkstationand
PeripheralsACWiringGuide(BSTO211553)forstoreACwiringrequirements.The
ACoutletmustbeinstalledneartheterminalandeasilyaccessibletotheoperator.

26

NCR RealPOS 82XRT Terminal Site Preparation

TComponent Weights
Terminal Component

Weight kg

(lbs.)

7606Terminalw/Batteries

10.7

(23.5)

7606Terminalw/oBatteries

8.8

(19.3)

IntegratedTrayKit

8.6

(18.0)

2181Cashdrawer

6.0

(13.3)

2185CashDrawer

12.3

(27.0)

2186Cashdrawer

12.3

(27.0)

64KeyKeyboard

0.9

(1.9)

78KeyKeyboard

1.1

(2.4)

BigTicketKeyboard

1.0

(2.15)

104KeyCompactKeyboard

1.4

(3.0)

59751xxxCustomerDisplay

11.9

(26.5)

59752xxxCustomerDisplay

0.5

(1.2)

59761xxxCustomerDisplay

0.3

(0.6)

594212.1TouchLCD

2.8

(6.2)

594312.1LCD

2.1

(4.8)

5965TouchLCD

4.0

(8.8)

5966TouchMonitor

5.4

(11.9)

7167Receipt/ImpactPrinter

4.5

(10.0)

7168Receipt/ImpactPrinter

5.0

(11.0)

7197ThermalReceiptPrinter

1.5

(3.4)

7198ThermalReceiptPrinter

2.2

(4.9)

NCR RealPOS 82XRT Terminal Site Preparation

27

Shipping Weight Estimate


Toobtainthetotalmaximumweightofaspecificconfiguration,addtheweightsof
theappropriateindividualcomponents.Thefollowingtableprovidesanexample.
Terminal Component

Weight kg

(lbs.)

IntegratedTerminalw/Batteries

13.0

(35.0)

594212.1InchLCD

2.8

(6.2)

59752xxxCustomerdisplay

0.5

(1.2)

64Keykeyboard

0.9

(1.9)

7167Receipt/ImpactPrinter

4.5

(10.0)

Total

21.7

(54.3)

Miscellaneousitemsand

5.2

(11.5)

26.9

(65.8)

shippingmaterials
Shippingtotal

Service Clearance Requirements


Device

Above
mm (in.)

Left Side
mm (in.)

Right Side
mm (in.)

Front
mm (in.)

Behind
mm (in.)

TerminalBase

100(4.0)

100(4.0)

100(4.0)

Keyboard

100(4.0)

CashDrawer

330(13.0)

7162Printer

325(13.0)

300(12.0)

100(4.0)

25(1.0)

7167Printer

305(12)

305(12)

7168Printer

305(12)

305(12)

7197Printer

267(10.5)

5953DynaKey

50(2)

25(1)

100(4)

5942/43LCD

50(2)

25(1)

25(1.0)

5964TouchLCD

50(2)

25(1)

100(4)

5975Display

25(1.0)

25(1.0)

28

NCR RealPOS 82XRT Terminal Site Preparation

Airflow Requirements
Donotblocktheairventsontheterminal.Theseventsarenecessaryforcooling.

24089a

Donotplacetheterminalinanenclosedareawheresufficientventilationisnot
available.Leaveatleast100mm(4inches)ofclearanceonsideswhereairventsare
located.
Whentheterminaliswallmounted,therearcovermusthaveatlease6mm(0.25in.)
clearancefromthewall.Themountingmechanismmustnotblocktheventholeson
therearcover.

Appendix A: Transient Protection

AC Power Line Transient Protection


Intheprocessofpowerdistribution,transientelectricalenergy(including,butnot
limitedto,lightningstrikes,intermittentshortcircuits,andswitchingtransients)can
beintroducedontopowerlines.Suchtransientenergycanbeverydamagingto
electronichardware,andcanalsocausedatacorruption.Underthesecircumstances,
NCRrecommendstheuseofACpowertransientsuppressors.Suchprotection
devicesareintendedtoguardagainstpowerlinetransientsthatcanresultin
hardwaredamageandvarioussystemorprogramerrors.
Improvementofanydeficienciesinpowerqualityisacustomerresponsibility.
Malfunctionand/orcomponentfailureasaresultofpowerqualityproblemsare/is
notcoveredbytheNCRMaintenanceAgreement.NCRacceptsnoliabilityforany
suchoccurrencenorforitsconsequences.
Whenpowertransientsuppressionisrequired,thesuppressorsusedshouldmeetthe
followingminimumrequirements:

DissipateenergytomatchtheappropriatelocationcategoriesasdefinedbyIEEE
StandardC.62.41.22002.

Beofthevoltagelimiting(clipping),ortrackingfiltertype.Thesuppressormust
notclampthevoltagetozero,andmustselfrecoverafterthepassageofthe
transient.Thesuppressormaybeofthehybridtypeconstructionthatmakesuse
ofvarioustechnologiesinordertomeetspeedanddissipationrequirements.

TranUponfailure,exhibitapositiveindicationofitsfailuresuchasablownfuse
ortrippedbreaker.

Belistedbytheacceptedsafetyorganizationforthecountryinvolved(UL,CSA,
VDE,ETL,andsoon)andtheinstallationmustconformtolocal,state,and
nationalelectrical

Data Line Transient Protection


Thenatureofthetransientphenomenonmayextendtothedatacommunicationlines
connectedtothisequipment.Itistheresponsibilityofthecustomertoinstalland
connectadatalinetransientsuppressionsystemtocorrectorpreventany
deficiencies.Suchsystemsmustmeetthefollowingminimumrequirements:

Beofthevoltagelimitingtypeandmustselfrecoverafterpassageofthetransient.

Mustbedesignedtoavoidsignaldegradationforthegiveninterfacetheyare
attachedto.

Beinstalledinaccordancewithallapplicablelocal,state,andnationalelectrical
codesandregulation.

Note: NCRprovidesafulllineofbothACpoweranddatalinetransientsurge
suppressorstoprotectyourRealPOSsystemandreducedowntimeandextendthe
lifeoftheRealPOSRetailSolution.Forsizingandproductinformation,pleasecall
NCRSitePreparationServicesat8002570458.
ThefollowingproductofferingsareavailablefromNCRSitePreparationServices:

UPSUninterruptiblePowerSystems

Providesbatterybackupforpoweroutagesandbrownouts.

IncludesACanddatalinesurgeprotection.

Ifneeded,certainmodelsprovidebasicvoltageregulation.

Smallsizeprovideseasyinstallation.

LineConditioners/Filters

IncorporatesanIsolationtransformerorfilterthatprovides100%isolation
fromdisturbancesontheincomingACpowerline.

RemovesEMI/RFInoisethatcausesequipmentlockups.

Reducescommonmodenoiseissuesandsurges/transients.

SignificantlyreducesPOSdowntimeandcomponentfailure.

TransientVoltageSurgeSuppressors

ProvidesprotectionfromcatastrophicACsurges/transients.

Providesdatalineprotectionfromcatastrophicsurgesthatcanmigrateonto
thedatalineandnetwork.

Potrebbero piacerti anche