TECHNICAL DATA

Housing Material Dimensions Protection rate Connection sensor cable/Cable gland Ambient Temperature LCD Display Programming key board Pulse/frequency/alarm output Current output Bi-directional FS value Diagnostic functions Empty pipe detect. Galvanic isolation Data storage Programming plug in CE certification Measurements tolerance Repeatability Power supply Consumption

Nylon with fiber glass 120 X 120 X 55 mm IP 65 C018 cable ( MAX 20 m ) / Standard N 3 PG 11 0+50C Alphanumerical display 16 characters x 2 lines not back light 3 internal keys programmable function max 1250 Hz, 100mA, 40 Vdc N1 0/420mA RL 800 Yes 0,410m/s Yes Yes All the outputs are galvanically isolated from power supply EEprom stored measuring values on power failure Protected plug in for connection to PC or hand terminal Instrument with CE certificate Flow rate (volume) = 0,1% v.l. Out 4/20 mA = 0,12 % v.l. Frequency Out = 0,12% v.l. +/- 0,2 % 90265 Vac 4566 Hz; 1063Vdc/1545 Vac-4566Hz; 5 VA 4 VA ( AC ) / 3 W max ( DC )

The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Page 2 of 7

ML110_EN_DS016REV00_IS

ML 110

OVERALL DIMENSIONS

COMPACT VERSION

127

124

SEPARATE VERSION

79

65

The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Page 3 of 7

129

ML110_EN_DS016REV00_IS

168

25

ML 110

VISUALIZATION PAGES

Flow rate value

Tolalizer values

Direct and reverse totalizer

Flowrate and speed of media

Alternate visualization of data

Alarm ON visualization

Different possibilities of visualization with the simple pressure of a key

The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Page 4 of 7

ML110_EN_DS016REV00_IS

ML 110

ELECTRICAL CONNECTIONS

TERMINAL BLOCK VIEW

E C

E C

1 2 3 4 5 6 7 8 9 10

20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
+

11 12 13 14 15 16 17 18 19 20

4-20mA

ON/OFF OUTPUT

ON/OFF OUTPUT
Terminal 16 18 (Out 1) (Out 2)

43 V

Terminal 17 19 (Out 1) (Out 2)

ANALOG OUTPUT

ANALOG OUTPUT
+24V INTERNAL I

mA Terminal (9+) 0/4..20mA OUT 24V COMMON

Terminal (10-)

The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

Page 5 of 7

24V

OUT2

OUT1

24V SC B2

COILS
B1 SC

SC

E2

E1

ELECTRODES

ML110_EN_DS016REV00_IS

ML 110

1.7 AUTOZERO CAL. 6.7 USC.mA2 8.5 CURRENCY 8.6 CUR. DECIM. 8.7 XXX/dm + 8.7 RESET P-

2.7 TPUL2

Vedere la relativa tabella di riferimento nella descrizione delle funzione al menu 6 "USCITE"

The Manufacturer Guarantee Only English Text Available on our web site: www.isoil.com

1.SENSOR 8.DISPLAY
8.1 LANGUAGE 9.1 GG/MM/AA 00:00 9.2 ACQUISITION 9.3 INTERVAL 9.4 DISPLAY DATA 9.5 DISPLAY EVENTS 9.6 DISP. MIN/MAX 9.7 CLEAR DATA 9.8 CLEAR EVENTS 9.9 RESET MIN/MAX 10.2 SELFTEST 10.3 SIMULATION 8.2 D.RATE 8.3 CONTRAST 8.4 RESET T+ 8.5 RESET P+ 8.6 RESET T10.1 CALIBRATION

2.SCALE 9.DATA LOGGER


4.1 MAX THR 6.1 OUT.1 6.2 OUT.2 6.3 OUT.3 6.4 OUT.4 6.5 DUTY CICLE 1-2 6.6 USC.mA1 4.2 MIN THR 4.3 HYST 4.4 E.P. THR 4.5 mA VAL.FAULT 4.6 Hz VAL.FAULT

3.MEASURE 6.OUT 10. DIAGNOSI

4.ALARM

11.DATI INTERNI
11.1 L2 KEYCODE 11.2 LOCK LEVEL 11.3 LOAD FACT. PRES. 11.4 LOAD USER PRES. 11.5 SAVE USER PRES. 11.6 HOURS 11.7 IGN.CAL.ERR. 11.8 KS

1.1 ND

2.1 FS1

3.1 T. CONST

1.2 COEFF. KA

2.2 FS2

3.2 SKIP THR

1.3 S. MODEL

2.3 MU.TOT

3.3 PEAK THR

1.4 INS. POSITION

2.4 IMP1

3.4 CUT-OFF

FUNCTIONS

Page 6 of 7

1.5 COEFF. KL+ / KL-

2.5 IMP2

3.5 FILTER

1.6 E.P. DETECT

2.6 TPUL1

3.6 AUTOCAL

3.7 ATORANGE

1.8 E.P. CALIBR.

2.8 FRQ1

3.8 E. SAVING

2.9 FRQ2

ML110_EN_DS016REV00_IS

ML 110

HOW TO ORDER

ML 110

Display A Blind execution (without display and programming keys) B Complete with 2 line back light display (each of 16 characters) and 3 programming keys Housing material - Protection rate 0 Nylon with glass fiber (IP 65) Version A Compact version with sensor MS.... (liquid maximum temperature 100 C) Separate version for wall monting, complete with mounting accessories B (C018 CABLE) Power supply 1 Power supply : 90 ... 265 V 45/66 Hz 2 Power supply : 18...63 V dc / 15...45 V ac - 45...66 Hz 9 Power supply : other Analogue output A Without analogue output B Analogue output 0/4...20/22 mA
EXAMPLE OF CODE FOR ORDER

ML 110 A 0 A 1 A

1 2 3 4 5 6 7 8 9 10

11 12 13 14 15 16 17 18 19 20

Uscita / output 0/4...20/22 mA

90..265VAC

>HV<

>LV<

15...45VAC 10...63VDC

ML 110

COMPACT VERSION

SEPARATE VERSION

INTERNAL VIEW

In accordance with a continuous evolution of the product, the company reserves the right to modify without warning the information contained in this document

Production / stock 35044 Montagnana PD 21,via Frassenara

Potrebbero piacerti anche