Sei sulla pagina 1di 68

york air-conditioning products

Residential & VRF 2012

At Johnson Controls, we look at buildings in a way very few others have ever imagined. When we look at a building, we see beyond the bricks and mortar. Beyond the steel and glass. We see a bigger picture. We see the power of the human enterprise. Thats why we create buildings and environments that help people achieve and that give buildings, businesses and people every opportunity to reach their full potential.

york air-conditioning products

Residential & VRF Air-conditioning solutions


Every market is unique in air-conditioning requirements. In this catalogue our customers will be able to select the different options for residential market and VRF solutions for Light-Commercial market. Johnson Controls wants to offer all the possible solutions for different building design and technical requirements, and the air-conditioning is an important part of those global solutions.

MINISPLIT SOLUTIONS High Wall inverter Multisplit inverter Console inverter Floor/ceiling inverter Cassette inverter Blower inverter High Wall on/off High Wall multisplit on/off Floor/ceiling on/off Cassette on/off Blower on/off Window unit

04/05

The majority of our products are already rated as Class A for Energy Efficiency, in order to guarantee a high level of comfort.

According to the market necessities our customers can find the best solution in our wide product range depending on the building characteristics.

VRF SOLUTIONS (Outdoor units) Capacities from 10 to 180 kW Operating range of nominal power (10% - 100 %) Digital Scroll Technology Low noise levels High performance Flexible and quickly installation

VRF SOLUTIONS (Indoor units) High Wall Cassette Convertible console floor/ceiling Floor standing Floor standing concealed Blower

york air-conditioning products

Catalogue Content
Pag.

Split Systems
High wall High Efficiency Inverter - NEW High wall Inverter - NEW High wall Inverter Multi Inverter Free Indoor Units - NEW Console Inverter Floor/Ceiling Inverter Cassette Inverter Blower Inverter High wall On/Off - NEW High wall On/Off High wall Multi split - NEW Floor/Ceiling Cassette Blower Window unit YWHJZH 09 to 24 YRHJZH 09 to 24 EVHC-D 09 to 24 ERJC 18 to 42 ECHC-D 09 to 18 EOHC-D 09 to 60-R EKHC-D 12 to 42-R EUHC-D 09 to 60-R YVHFZH 09 to 24 EAHC 09 to 24 FS-R YEHNZH 18 to 24 (2x1) EOHC 09 to 48 FS EKHC 12 to 48 FS EUHC 12 to 60 FT Y8USE 9 to 24 20 22 24 26 30 32 34 36 40 42 44 46 48 50 52

VRF Systems
YDS-C Variable refrigerant flow system YDMH 100, 140, 280, 335, 400, 450 C 58

06/07

Cooling capacity kW
1.0
2.5 - 7.0 2.6 - 6.4 2.4 - 6.0 5.0 - 11.6 2.7 - 5.3 3.0 - 16.0 3.4 - 11.0 2.7 - 15.8 2.7 - 6.3 2.5 - 6.3 5.6 - 7.0 2.5 - 13.2 3.5 - 13.2 3.5 - 16.0 2.8 - 6.2

5.0

10.0

20.0

50.0

100.0

200.0

10 - 180

york air-conditioning products

08/09

Minisplit Inverter Systems


high wall units multisplits free combination console, cassette, floor/ceiling & blower units

york air-conditioning products

10/11

efficient comfort
high efficiency inverter range
The High Wall inverter air conditioners have been designed thinking about comfort and sustainability. Comfort as the ultimate technology of DC Inverter compressor installed in these units is able to achieve performances of 4.25 COP in heating and cooling mode, the temperature variations in the room are minimized and the noise level is lower. The active carbon electrostatic filter improves the air quality and thanks to the motorized louver system, the air is distributed equally in the room. Sustainable because the high efficiency of the unit results in a very low energy consumption, one of the most efficient in the market, the materials used are recyclable and free of hazardous substances, all together makes this unit the appropriate choice for conditioning your home.

york air-conditioning products

12/13

i n v e rt e r syst e m h i g h e r e f f i c i e n cy a n d c o m f o rt
conventional system

inverter system

Compressor capacity

Indoor temperature

Desired temperature

energy savings

44%

energy saving

Conventional air conditioning

DC INVERTER air conditioning

DC Inverter technology regulates the frequency of the compressor which results in many advantages:  Energy saving by avoiding consumption peaks of the compressor compared to an on-off system. Inverter compressors reduce the frequency and therefore increase the efficiency.  The variations of the temperature in the room are reduced improving the comfort.  The setting temperature is achieved faster thanks to the flexibility of the system which allows reaching even 30% more of the nominal capacity.  The overall performance is more uniform and silent.

york air-conditioning products

14/15

f i lt e r o pt i o n s f o r a c l e a n a n d h e a lt h y a i r

STANDARD FILTER
These filters prevent the bigger dust particules to enter the room by creating a barrier against dirtyness and insects.

SILVER ION FILTER


The Silver ion filter kills bacteria in the air and controls the growth of microbes, such as bacteria, virus, fungi, and spores, by destroying their inner configuration and absorbing the cells elements.

PLASMA FILTER
The Plasma Dust Collector can generate an ionization zone. The air is converted to plasma as it passes the high voltage ion generator. 95% of the dust, smoke and pollen particles are attracted to the electrostatic filter.

CARBON ELECTROSTATIC FILTER


Active Carbon Filter eliminates certain kinds of odors such as ammonia (NH3) and deactivates harmful chemical gas such as formaldehyde (HCHO).

DRY MOULD PROOF


Turn off the unit that contains this function when it is cooling or drying, indoor fan would still operate in low speed to dry the inner components and parts. This action can remain unit inside clean and dry, prevent mould growing and olor.

york air-conditioning products

Range Capacities
2.0
High Wall High Efficien. Inverter

2.5
2.5

3.0

3.5
3.5

4.0

4.5

5.0

5.5
5.3

6.0

6.5

7.0
7.0

7.5

8.0

8.5

9.0

9.5

10.0

Page 20
High Wall Inverter
2.6 3.5 5.4 6.4

Page 22
High Wall Inverter
2.4 3.5 5.3 6.0

Page 24
Multi Inverter ERJC
5.0 7.0 7.1 8.0 9.0

Page 26
Console Inverter
2.7 3.6 5.3

Page 30
Floor Ceiling Inverter
3.0 3.4 5.3 6.8 8.8

Page 32
Cassette Inverter
3.4 5.2 7.0 8.8

Page 34
Blower Inverter
2.7 3.4 5.3 6.8 8.0

Page 36
High Wall On/Off
2.7 3.4 5.1 6.3

Page 40
High Wall On/Off
2.5 3.1 4.6 6.2

Page 42
High Wall Multi Split
5.6 6.3 7.0

Page 44
Floor Ceiling
2.5 3.5 5.2 7.2

Page 46
Cassette
3.5 5.3 7.0

Page 48
Blower
3.5 5.2 7.0

Page 50
Window
2.8 3.8 5.3 6.2

Page 52

16/17

10.0

10.5

11.0

11.5

12.0

12.5

13.0

13.5

14.0

14.5

15.0

15.5

16.0

16.5

17.0

17.5

18.0

18.5

kW

11.6

10.6

11.8

13.6

16.0

10.1

11.0

10.1

10.6

13.8

15.8

10.0

12.0

13.2

10.0

12.0

13.2

10.2

12.2

13.2

16.0

Minisplit Systems

york air-conditioning products

Main Features
More efficient A B C D E F G Less efficient

EU Energy Label A Class


With the powerful compressor and optimized refrigerant, the EER can reach EU Energy Label A Class (over 3.2 w/w) or B Class (over 3.0 w/w), greatly reducing the power consumption.

Heater Cable
Heater cable prevents ice forming on the outdoor unit. Specially indicated in heat pump mode and low ambient temperature conditions. A thermostat regulates the activation of the heater.

Auto-Restart Function
When the power supply is interrupted and then restored, the air conditioners automatically restore the previous function setting.

Turbo Mode
Press the Turbo button and the A/C will reach the preset temperature in the shortest time.

Two-direction Air Vane Tech


With special structural design and microcomputer control, York air conditioners employs a unique bidirectional rotary air vane technology.

Condensate pump
Made up of a pump and a remote detection unit. The pump absorbs the condensates from the indoor unit and sends it to the draining pipes.

Low Ambient Kit


The air conditioning unit can operate in cooling mode at low ambient temperature conditions. The kit is suitable for special applications such as computer and power station control rooms where cooling is required even in the winter months.

Dehumidification
Independent dehumidification function is usually used in rainy days in springtime or damps areas. The unit will alternately operate in cooling mode or fan only mode, which assures strong dehumidification while not lowering room temperature.

Sleep Mode
With Spleep Mode, the air conditioners set temperature will automatically increase (cooling) or decrease (heating) 1C per hour for the first two hours then hold steady for the next 5 hours after which the air conditioner will stop operation. With the sleep mode function can maintain the most confortable temperature and save energy.

Bio Filter
Bio Filter consists of a specialized biological enzyme and Eco Filter. The Eco Filter catches very small airborne dust particles and neurilities bacteria, fungi and microbes. Biological enzyme eliminates bacteria by dissolving their cell wall thus eliminating the problem of re-pollution seen in traditional air conditioners.

18/19

Active Carbon Electrostatic Filter


Active Carbon Filter eliminates certain kinds of odors such as ammonia (NH3) and deactivates harmful chemical gas such as formaldehyde (HCHO). By forming positive positions on the filter surface, Electrostatic Fiber Filter traps small dust particles, smoke and pet fur to prevent allergic reactions.

Ionizer
Ionizer brings refreshing air into the home. Anions can stimulate the blood circulation system, improve lung function and effectively prevent respiratory passage illnesses (sutch as asthma and pneumonia).

Plasma Filter
The Plasma Dust Collector can generate an ionization zone. The air is converted to plasma as it passes the high voltage ion generator. 95% of the dust, smoke and pollen particles are attracted to the electrostatic filter.

Valve Protection Cover


It protects the service valves and prevents water from dripping.

Anti-Rust Cabinet
Made from electrolytic zinc steel sheet and antirust coated components. Yorks outdoor units are rust free even in coastal regions.

Iconography

Infrared control

Wired control

Infrared or Wired control

Dry mode

Sleep mode

Timer

Auto Sweep

Auto Restart

Turbo mode

Thin profile

Quiet

4 Way Air Flow

Floor/ Ceiling

Ducted Installation

Air Filter

Low Ambient Kit

Minisplit Systems

Main Features

york air-conditioning products

High Wall High Efficiency Inverter


YWHJZH 09 to 24
A complete range from 2.5 kW to 6.4 kW

NEW

Features
DC Inverter compressor Low noise levels Ultra high EER&COP, up to 5.01/5.21 Multi louvers design for faster heating 1W standby Quiet design with low noise to 21dB(A) 8C heating 3 sleep modes/curves Intelligent defrosting LED display Overlong distance air flow Blue crystal fin evaporator 7 fan speeds with turbo cooling  3D-airflow with auto horizontal airflow (Left/Right)  Low Ambient Kit  Heater cable  Gold fin condenser Service valve protection cover

Remote controller
Wireless I FEEL function  5 operation modes(Cool/ Heat/Auto/Dry/Fan) 5 Fan speeds selection Quiet/sleep button Air flow direction setting LCD display Turbo mode Room temperature setting Lock Button Function

20/21

High Wall High Efficiency Inverter


YWHJZH 09 to 24

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit Type of connection Piping Diameter Gas Liquid g m m min./max. min./max. 3/8 1/4 740 15 10 3/8 1/4 1 000 20 10 +10C / +48C -15C / +24C W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg cooling heating V/Ph/Hz kW kW 0.60 0.66 4.16 4.16 A A 330 / 370 / 420 24 / 28 / 32 41 292 806 206 540 848 320 10.5 36 0.83 0.83 4.21 4.00 A A 410 / 530 / 670 24 / 32 / 36 43 292 866 206 596 899 378 11 43 Flare 5/8 1/4 1 160 25 10 5/8 1/4 1 700 25 10 Sizes Sizes kW kW Type YWHJXH-09 YWHJYH-09 2.5 (0.7 - 3.8) 2.7 (0.7 - 4.0) YWHJXH-12 YWHJYH-12 3.5 (0.7 - 4.5) 3.6 (0.7 - 5.5) Rotary R410A 230 / 1 / 50 + E 1.45 1.47 3.65 3.81 A A 630 / 710 / 870 36 / 39 / 41 49 315 1 017 234 700 955 396 15 50 2.00 2.11 3.50 3.61 A A 700 / 800 / 900 41 / 43 / 45 51 326 1 178 264 790 980 427 18 68 YWHJZH YWHJXH-18 YWHJYH-18 5.3 (0.8 - 6.7) 5.6 (1.0 - 7.3) YWHJXH-24 YWHJYH-24 7.0 (1.3 - 8.7) 7.6 (1.2 - 10.0)

Indoor airflow (L / M / H) Sound pressure Indoor (L/M/H) at 1 m Outdoor

Refrigerant charge Pipe run Length Height

Operating limit - cooling mode Operating limit - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Accessories
Sizes Electrostatic dedusting filter Silver ion filter Active carbon filter 09 12 Optional Optional Optional 18 24

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

High Wall Inverter


YRHJZH 09 to 24
A complete range from 2.6 kW to 6.4 kW

NEW

Features
DC Inverter compressor Low noise levels High EER&COP, Class A 1W standby LED display Automatic restart Automatic clean Intelligent defrosting Confortable sleep mode Cold air prevention Self-diagnosis Service valve protection cover  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless  5 operation modes(Cool/ Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Air flow direction setting LCD display Turbo mode Lock Button Function

22/23

High Wall Inverter


YRHJZH 09 to 24

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit Type of connection Piping Diameter Gas Liquid g m m min./max. min./max. 3/8 1/4 740 15 5 3/8 1/4 1 000 15 5 +10C / +48C -15C / +24C W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg cooling heating V/Ph/Hz kW kW 0.80 0.99 3.30 3.65 A A 280 / 370 / 520 24 / 30 / 36 34 283 770 201 550 658 275 8 28 1.10 1.14 3.25 3.63 A A 300 / 410 / 560 25 / 31 / 37 35 283 770 201 550 658 275 9 30 Flare 1/2 1/4 1 160 25 10 1/2 1/4 1 700 25 10 Sizes Sizes kW kW Type YRHJXH-09 YRHJYH-09 2.6 (0.4 - 3.2) 3.5 (0.4 - 4.1) YRHJXH-12 YRHJYH-12 3.5 (0.6 - 4.0) 4.0 (0.6 - 5.1) Rotary R410A 230 / 1 / 50 + E 1.70 1.70 3.23 3.61 A A 460 / 560 / 680 32 / 37 / 40 42 380 945 295 700 955 396 12 52 2.00 1.90 3.22 3.62 A A 550 / 700 / 800 34 / 39 / 44 44 319 1 008 221 700 955 396 15 55 YRHJZH YRHJXH-18 YRHJYH-18 5.4 (1.0 - 6.4) 5.7 (1.0 - 7.1) YRHJXH-24 YRHJYH-24 6.4 (1.4 - 7.0) 6.7 (1.2 - 8.0)

Indoor airflow (L / M / H) Sound pressure Indoor (L/M/H) at 1 m Outdoor

Refrigerant charge Pipe run Length Height

Operating limit - cooling mode Operating limit - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Accessories
Sizes Electrostatic dedusting filter Silver ion filter Active carbon filter 09 12 Optional Optional Optional 18 24

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

High Wall Inverter


EVHC-D 09 to 24
A complete range from 2.4 kW to 6.0 kW

Features
DC Inverter compressor Low noise levels Dry mould proof Automatic restart ON/OFF timer Automatic air sweep Service valve protection cover Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer setting function Air flow direction setting LCD display Turbo mode Lock button function

24/25

High Wall Inverter


EVHC-D 09 to 24

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit Type of connection Piping Diameter Gas Liquid g m m min./max. min./max. 3/8 1/4 730 15 10 3/8 1/4 950 20 10 +18C / +50C -15C / +24C W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg cooling heating V/Ph/Hz kW kW 0.78 0.78 3.21 3.61 A A 500 32 / 35 / 37 50 265 790 170 540 776 320 9 27 1.08 1.12 3.24 3.61 A A 500 33 / 36 / 39 52 275 845 180 540 776 320 11 29 Flare 1/2 1/4 1 100 25 10 1/2 1/4 1 400 25 10 Sizes Sizes kW kW Type EVKC-09DS EVJC-09DS 2.4 (0.6 - 3.2) 2.8 (0.8 - 3.6) EVKC-12DS EVJC-12DS 3.5 (0.5 - 3.9) 3.9 (0.9 - 4.4) Rotary R410A 230 / 1 / 50 + E 1.70 1.71 3.21 3.41 A B 850 38 / 42 / 45 53 298 940 200 700 890 340 13 47 1.96 2.05 3.21 3.41 A B 900 40 / 43 / 48 54 330 1 060 208 700 890 340 16 50 EVHC EVKC-18DS EVJC-18DS 5.3 (1.3 - 6.2) 5.8 (1.3 - 6.3) EVKC-24DS EVJC-24DS 6.0 (1.4 - 6.8) 6.8 (1.3 - 8.0)

Indoor airflow (high speed) Sound pressure Indoor (L/M/H) at 1 m Outdoor

Refrigerant charge Pipe run Length Height

Operating limit - cooling mode Operating limit - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Accessories
Sizes Electrostatic dedusting filter Silver ion filter Cold Plasma filter Active carbon filter 09 12 Optional Optional Optional Optional 18 24

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Multi Inverter Free Indoor Units


ERJC 18 to 42
A complete range from 5.0 kW to 11.6 kW

NEW

ERJC 18-22 (2x1)

ERJC 24 (3x1) / ERJC 28 (4x1) / ERJC 36 (4x1)

Features
DC inverter compressor Classe A cooling and heating Free match indoor/outdoor Automatic restart ON/OFF timer Automatic air sweep Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer Air flow direction setting LCD display

Indoor units

26/27

Multi Inverter Free Indoor Units


ERJC 18 to 42

Technical features Outdoor units


Model Outdoor units Sizes 18 2 indoor units 5.0 (2.1 - 6.2) 5.6 (2.5 - 6.7) 22 2 indoor units 7.0 (2.7 - 8.2) 7.7 (3.5 - 9.5) 24 number Indoor units Cooling capacity kW Heating capacity kW Compressor Type (Nb) Refrigerant Location of expansion device Power supply V/Ph/Hz cooling kW Power input heating kW EER COP cooling Energy Class heating Airflow (outdoor unit) m3/h Sound pressure level dB(A) Dimensions outdoor unit H / W / D mm Net weight outdoor unit kg Type of connection Piping Gas Diameter Liquid Length m Max pipe run * Height m Refrigerant charge g Operating limits - cooling mode min/max Operating limits - heating mode min/max ERJC-R 28 36 4 indoor units 9.8 (2.5 - 14.7) 11.0 (2.8 - 16.5) 42 5 indoor units 11.6 (2.4 - 17.4) 13.0 (2.7 - 19.5) 3 indoor units 4 indoor units 7.1 (2.2 - 10.0) 8.0 (2.2 - 10.0) 8.5 (3.6 - 11.0) 9.3 (2.8 - 11.0) Rotary Inverter (1) R410A Outdoor unit 230 / 1 / 50 + E 2.20 2.48 2.35 2.55 3.21 3.23 3.62 3.63 A A A A 3 300 3 300 52 53 700 / 955 / 396 700 / 955 / 396 59 60 Flare 3/8 3/8 1/4 1/4 15 15 10 10 2 200 2 200 -5C / +43C -10C / +24C

1.55 1.54 3.23 3.64 A A 2 600 50 596 / 899 / 378 43 3/8 1/4 15 10 1 350

2.18 2.26 3.21 3.41 A B 3 300 52 700 / 955 / 396 59 3/8 1/4 15 10 2 400

3.03 3.01 3.23 3.65 A A 3 300 54 1 100 / 1 015 / 440 78 3/8 1/4 15 10 4 300

3.59 3.54 3.23 3.67 A A 3 300 54 1 100 / 1 015 / 440 79 3/8 1/4 15 10 4 800

* Each indoor unit Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge (each indoor unit)

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Indoor units technical features


Active carbon electrostatic filter Automatic air sweep
Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h H/M/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid 09 2.6 2.8 500 34 / 31 / 28 265 / 790 / 170 9 3/8 1/4 ERKC 12 3.5 3.8 230 / 1 / 50 + E 630 34 / 32 / 30 275 / 845 / 180 10 Flare 3/8 1/4 18 5.3 5.8 850 43 / 40 / 36 298 / 940 / 200 13 1/2 1/4

Console Automatic air sweep


Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h H/M/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid 09 2.6 2.8 480 38 / 33 / 26 600 / 700 / 215 15 3/8 1/4 ECKC 12 3.5 3.8 230 / 1 / 50 + E 550 40 / 37 / 32 600 / 700 / 215 15 Flare 3/8 1/4 18 5.3 5.8 650 46 / 41 / 35 600 / 700 / 215 15 1/2 1/4

Floor/Ceiling Automatic air sweep


EOKC Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping Sizes kW kW V/Ph/Hz m3/h H/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid 09 2.5 2.8 650 40 / 36 700 / 1 220 / 225 40 3/8 1/4 12 3.5 3.9 18 5.0 5.5 24 7.1 8.0 1 250 48 / 40 700 / 1 220 / 245 45 5/8 3/8

230 / 1 / 50 + E 650 950 40 / 36 45 / 40 700 / 1 220 / 225 700 / 1 220 / 225 40 40 Flare 1/2 1/2 1/4 1/4

Condensate pump included 600 x 600 standard size


Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions unit Dimensions panel Net weight unit Net weight panel Piping Sizes kW kW V/Ph/Hz m3/h High speed dB(A) H/W/D mm H/W/D mm kg kg Type of connection Gas Diameter Liquid 12 3.5 4.0 600 46 230 / 570 / 570 50 / 650 / 650 18 6.5 3/8 1/4 EKKC 18 4.5 5.0 230 / 1 / 50 + E 600 46 230 / 570 / 570 50 / 650 / 650 18 6.5 Flare 1/2 1/4 24 7.1 8.0 1 180 39 240 / 840 / 840 60 / 950 / 950 30 6.5 5/8 3/8

28/29

Slim size Air filter included


Indoor units Cooling capacity Heating capacity Power supply Indoor airflow Sound pressure level Dimensions Net Weight Piping

Wired control included


EUKC Sizes kW kW V/Ph/Hz m3/h H/L dB(A) H/W/D mm kg Type of connection Gas Diameter Liquid 09 2.5 2.8 450 37 / 31 200 / 700 / 615 22 3/8 1/4 12 3.5 3.9 18 5.0 5.5 24 7.1 8.0 1 000 42 / 34 200 / 1 100 / 615 29 5/8 3/8

230 / 1 / 50 + E 500 700 39 / 32 40 / 33 200 / 700 / 615 200 / 900 / 615 24 25 Flare 1/2 1/2 1/4 1/4

Indoor unit combinations


ERJC 18 (2x1)
Number connecting units 2x1
9+9 9+12

ERJC 22 (2x1)
Number connecting units 2x1
9+9 9+12 12+12 9+18 12+18 18+18

ERJC 24 (3x1)
Number connecting units 2x1
9+9 9+12 12+12 9+18 12+18 9+9+9 9+9+12 9+12+12 9+9+18

3x1
12+12+12 9+12+18 12+12+18 9+18+18

ERJC 28 (4x1)
2x1
9+9 9+12 12+12 9+18 12+18 18+18

Number connecting units 3x1


9+9+9 9+9+12 9+12+12 12+12+12 9+9+18 9+12+18 12+12+18 9+18+18 9+9+9+9 9+9+9+12 9+9+9+18 9+9+12+12 9+9+12+18

4x1
9+12+12+12 9+12+12+18 9+9+18+18 12+12+12+12

ERJC 36 (4x1)
2x1
9+9 9+12 12+12 9+18 12+18 18+18 9+24 12+24 18+24 24+24

Number connecting units 3x1


9+9+9 9+9+12 9+12+12 9+9+18 12+12+12 9+12+18 12+12+18 9+18+18 18+18+18 9+9+24 9+12+24 9+18+24 9+24+24 12+12+24 12+18+24 12+24+24 18+18+24 9+9+9+9 9+9+9+12 9+9+9+18 9+9+9+24 9+9+12+12 9+9+12+18 9+9+12+24 9+12+12+12 9+12+12+18 9+12+12+24

4x1
9+9+18+18 9+9+18+24 9+12+18+18 9+12+18+24 12+12+12+12 12+12+12+18 12+12+12+24 12+12+18+18

ERJC 42 (5x1)
Number connecting units 2x1
9+9 9+12 12+12 9+18 12+18 18+18 9+24 12+24 18+24 24+24 9+9+9 9+9+12 9+12+12 9+9+18 12+12+12 9+12+18 12+12+18 9+18+18 18+18+18 9+9+24

3x1
9+12+24 9+18+24 9+24+24 12+12+24 12+18+24 12+24+24 18+18+24 9+9+9+9 9+9+9+12 9+9+9+18 9+9+9+24 9+9+12+12 9+9+12+18 9+9+12+24 9+12+12+12 9+12+12+18 9+12+12+24

4x1
9+9+18+18 9+9+18+24 9+12+18+18 9+12+18+24 12+12+12+12 12+12+12+18 12+12+12+24 12+12+18+18

5x1
9+9+9+9+9 9+9+9+9+12 9+9+9+9+18 9+9+9+9+24 9+9+9+12+12 9+9+9+12+18 9+9+9+12+24 9+9+9+18+18

Minisplit Systems

york air-conditioning products

Console Inverter
ECHC-D 09 to 18
A complete range from 2.7 kW to 5.3 kW

Features
Inverter DC compressor Air outlet at top or bottom 7 fan speeds 8C Heating mode Horizontal and vertical air sweep function Wide angle air distribution Service valve protection cover Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) 7 fan speeds Sleep mode Room temperature setting Fan speed selection Timer LCD display

30/31

Console Inverter
ECHC-D 09 to 18

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg Gas Liquid g m m min/max min/max Indoor (H/M/L) Outdoor cooling heating V/Ph/Hz kW kW 0.80 0.94 3.42 3.61 A A 430 / 370 / 280 38 / 33 / 25 51 600 700 215 540 848 320 15 33 3/8 1/4 1 000 15 10 Sizes Sizes kW kW Type ECKC 09 DS ECJC 09 DS 2.7 (0.5 - 3.2) 3.3 (0.5 - 3.8) ECHC-D ECKC 12 DS ECJC 12 DS 3.6 (0.6 - 4.0) 4.0 (0.6 - 4.7) Rotary R410A 230 / 1 / 50 1.13 1.12 3.23 3.63 A A 520 / 440 / 360 40 / 37 / 32 51 600 700 215 540 848 320 15 33 Flare 3/8 1/4 1 050 15 10 +10C / +50C -15C / +24C 1/2 1/4 1 230 25 10 1.62 1.56 3.26 3.62 A A 620 / 500 / 410 46 / 41 / 35 56 600 700 215 700 955 396 15 49 ECKC 18 DS ECJC 18 DS 5.3 (0.9 - 5.6) 5.5 (0.9 - 6.6)

Indoor airflow (H/M/L) Sound pressure at 1 m

Type of connection Piping Diameter

Refrigerant charge Pipe run Length Height

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Floor/Ceiling Inverter
EOHC-D 09 to 60 R
A complete range from 3.0 kW to 16.0 kW

Features
Inverter DC compressor Air filter included Convertible - floor or ceiling Horizontal and vertical air sweep function Wide angle air distribution  Low Ambient Kit (optional) Slim profile - flush mounting Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

Wired control
5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

32/33

Floor/Ceiling Inverter
EOHC-D 09 to 60 R

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg Gas Liquid g m m min/max min/max Indoor (H/M/L) Outdoor cooling heating V/Ph/Hz kW kW 0.85 0.75 3.50 4.00 A A 650/550/450 39 / 37 / 35 53 700 1 220 225 540 776 320 40 28 3/8 1/4 1 200 20 15 1.05 0.92 3.21 4.10 A A 700/600/500 39 / 37 / 35 54 700 1 220 225 540 776 320 40 30 3/8 1/4 1 350 20 15 230 / 1 / 50 1.65 1.70 3.21 3.61 A A 900/800/700 45 / 42 / 39 57 700 1 220 225 700 955 396 42 48 1/2 1/4 1 400 20 15 2.19 2.22 3.21 3.61 A A 52 / 49 / 46 59 700 1 220 225 790 980 427 43 65 5/8 3/8 2 400 30 15 2.75 2.64 3.21 3.61 A A 50 / 48 / 46 59 700 1 420 245 790 980 427 51 68 Flare 5/8 3/8 2 600 30 15 -10C / +50C -15C / +24C 5/8 3/8 3 500 30 15 5/8 3/8 3 800 50 30 5/8 3/8 4 300 50 30 3/4 3/8 5 500 50 30 Sizes Sizes kW kW Type EOHC-D-R EOKC 09 DS EOKC 12 DS EOKC 18 DS EOKC 24 DS EOKC 30 DS EOKC 36 DS EOKC 42 DS EOKC 48 DS EOKC 60 DS ENJC 09 DT ENJC 12 DT ENJC 18 DT ENJC 24 DT ENJC 30 DT ENJC 36 DT ENJC 42 DT ENJC 48 DT ENJC 60 DT 3.0 (1.6-3.5) 3.0 (1.4-3.8) 3.4 (1.6-3.6) 3.8 (1.4-4.1) 5.3 (1.3-5.5) 6.2 (1.5-6.6) 6.8 (3.0-7.8) 8.0 (2.4-8.5) 8.8 (3.1-9.0) 9.3 (2.7-9.9) Rotary R410A 230 / 1 / 50 or 400 / 3 / 50 3.26 3.16 3.21 3.61 A A 54 / 51 / 48 61 700 1 420 245 1 100 1 107 440 53 86 3.70 3.30 3.21 3.91 A A 54 / 51 / 48 61 700 1 420 245 1 100 1 107 440 55 90 4.20 4.40 3.21 3.75 A A 58 / 55 / 52 61 700 1 700 245 1 365 1 085 427 64 122 400 / 3 / 50 5.00 4.86 3.21 3.61 A A 58 / 55 / 52 63 700 1 700 245 1 365 1 085 427 65 127 10.6 (3.5-13.0) 11.8 (3.5-13.0) 13.6 (5.0-14.3) 16.0 (4.0-16.5) 11.9 (3.5-12.5) 12.6 (3.5-14.2) 15.9 (5.3-18.4) 17.5 (4.5-18.3)

Indoor airflow (H/M/L) Sound pressure at 1 m

1200/1050/900 1600/1450/1300 2000/1630/1520 2000/1630/1520 2300/2100/1900 2300/2100/1900

Type of connection Piping Diameter

Refrigerant charge Pipe run Length Height

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge Sizes 36 to 48: Values for single phase models

Accessories
Sizes Weekly timer Central control 09 12 18 24 30 Optional Optional 36 42 48 60

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Cassette Inverter
EKHC-D 12 to 42 R
A complete range from 3.4 kW to 11.0 kW

Features
Inverter DC compressor Air filter included Condensate pump standard  Fresh air intake for sizes 24 to 42 Auto restart  Low Ambient Kit (optional) Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

Wired control
5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

34/35

Cassette Inverter
EKHC-D 12 to 42 R

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class Cooling Heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Panel H / W / D Net weight Indoor unit Outdoor unit Type of connection Piping Refrigerant charge Pipe run Length Height Diameter Gas Liquid g m m min/max min/max 3/8 1/4 1 350 20 15 1/2 1/4 1 400 20 15 5/8 3/8 2 400 30 15 -10C / +50C -15C / +24C W (mm) D (mm) H (mm) W (mm) D (mm) mm kg kg Indoor (H/M/L) Outdoor Cooling Heating V/Ph/Hz kW kW 1.03 1.02 3.22 3.61 A A 550 / 450 / 350 47 / 45 / 42 54 230 600 600 540 776 320 50 / 650 / 650 20 30 1.65 1.70 3.21 3.61 A A 47 / 45 / 43 57 240 840 840 700 955 396 60 / 950 / 950 27 48 230 / 1 / 50 2.19 2.40 3.21 3.61 A A 51 / 49 / 48 59 240 840 840 790 980 427 60 / 950 / 950 27 65 Flare 5/8 3/8 2 600 30 15 5/8 3/8 3 500 30 15 5/8 3/8 3 800 50 30 2.75 2.64 3.21 3.61 A A 1660 / 1570 / 1500 53 / 51 / 48 59 320 840 840 790 980 427 60 / 950 / 950 32 68 Sizes Sizes kW kW Type EKKC 12 DS ENJC 12 DT 3.4 (1.6 - 3.6) 3.6 (1.6 - 4.0) EKKC 18 DS ENJC 18 DT 5.2 (1.9 - 5.5) 6.1 (1.5 - 6.6) EKHC-D-R EKKC 24 DS ENJC 24 DT 7.0 (2.4 - 8.3) 8.7 (3.1 - 9.4) Rotary R410A 230 / 1 / 50 or 400 / 3 / 50 3.20 3.00 3.21 3.61 A A 1660 / 1570 / 1500 53 / 51 / 48 61 320 840 840 1 100 1 107 440 60 / 950 / 950 32 86 3.30 3.30 3.22 3.61 A A 1660 / 1570 / 1500 53 / 51 / 48 61 320 840 840 1 100 1 107 440 60 / 950 / 950 38 90 EKKC 30 DS ENJC 30 DT 8.8 (3.0 - 9.1) 9.2 (2.5 - 9.9) EKKC 36 DS ENJC 36 DT 10.1 (3.0 - 11.5) 11.0 (3.5 - 12.8) EKKC 42 DS ENJC 42 DT 11.0 (3.5 - 13.0) 12.0 (3.8 - 14.5)

Indoor airflow (H/M/L) Sound pressure at 1 m

1180 / 1080 / 1000 1400 / 1270 / 1170

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge Sizes 36 and 42: values for single phase models

Accessories
Sizes Weekly timer Central control 12 18 24 Optional Optional 30 36 42

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Blower Inverter
EUHC-D 09 to 60 R
A complete range from 2.7 kW to 15.8 kW

Features
Inverter DC compressor Air filter included Condensate pump optional Fresh air intake Indoor unit with centrifugal fan Large distances between indoor and outdoor units Indoor units with high pressure Quiet operation Wired control Infrared remote control  Low Ambient Kit (optional)  Blue fin protection (indoor and outdoor units)

Wired control
5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer Air flow direction setting LCD display

36/37

Blower Inverter
EUHC-D 09 to 60 R

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h Pa dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg Gas Liquid g m m min/max min/max cooling heating V/Ph/Hz kW kW 0.85 0.75 3.21 3.61 A A 800/700/600 60 40 / 38 / 36 53 250 880 665 540 776 320 26 28 3/8 1/4 1 200 20 15 1.07 0.97 3.21 3.61 A A 840/740/640 60 37 / 35 / 33 54 266 980 721 540 776 320 34 30 3/8 1/4 1 350 20 15 230 / 1 / 50 1.65 1.70 3.21 3.61 A A 60 45 / 42 / 39 57 266 980 721 700 955 396 34 48 1/2 1/4 1 400 20 15 2.19 2.08 3.21 3.61 A A 80 47 / 44 / 42 59 268 1 270 530 790 980 427 37 65 5/8 3/8 2 400 30 15 2.56 2.44 3.21 3.61 A A 80 47 / 44 / 42 59 268 1 270 530 790 980 427 36 68 Flare 5/8 3/8 2 600 30 15 -10C / +50C -15C / +24C 5/8 3/8 3 500 30 15 5/8 3/8 3 800 50 30 5/8 3/8 4 300 50 30 3/4 3/8 5 500 50 30 Sizes Sizes kW kW Type EUHC-D-R EUKC 09 DT EUKC 12 DT EUKC 18 DT EUKC 24 DT EUKC 30 DT EUKC 36 DT EUKC 42 DT EUKC 48 DT EUKC 60 DT ENJC 09 DT ENJC 12 DT ENJC 18 DT ENJC 24 DT ENJC 30 DT ENJC 36 DT ENJC 42 DT ENJC 48 DT ENJC 60 DT 2.7 (1.2-3.0) 2.9 (1.0-3.0) 3.4 (1.6-3.6) 3.7 (1.6-4.0) 5.3 (1.6-5.8) 6.2 (1.4-6.5) 6.8 (2.0-7.7) 7.3 (2.4-8.0) 8.0 (2.7-8.3) Rotary R410A 230 / 1 / 50 or 400 / 3 / 50 3.20 3.06 3.21 3.62 A A 150 53 / 50 / 46 61 290 1 226 775 1 100 1 107 440 57 86 3.42 3.43 3.21 3.61 A A 150 53 / 50 / 46 61 290 1 226 775 1 100 1 107 440 57 90 4.36 4.50 3.21 3.67 A A 150 53 / 50 / 46 61 330 1 226 815 1 365 1 085 427 64 122 400 / 3 / 50 5.30 5.00 3.21 3.61 A A 150 54 / 51 / 48 63 385 1 463 799 1 365 1 085 427 87 127 10.1 (3.5-11.5) 10.6 (3.5-13.0) 13.8 (4.9-14.1) 15.8 (4.0-17.5) 8.4 (2.0-9.3) 11.5 (3.8-12.8) 12.4 (3.8-14.5) 16.0 (5.3-18.3) 18.0 (5.0-18.8)

Indoor airflow (H/M/L) External static pressure Sound pressure at 1 m Indoor (H/M/L) Outdoor

1000/800/600 1600/1400/1200 1500/1300/1100 2300/2110/1850 2300/2110/1850 2500/2300/2100 3150/2900/2600

Type of connection Piping Diameter

Refrigerant charge Pipe run Length Height

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge Sizes 36 to 48: Values for single phase models

Accessories
Sizes Condensate pump Weekly timer Central control 09 12 Optional 18 24 30 Optional Optional 36 42 Optional 48 60 -

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

38/39

Minisplit On/Off Systems


high wall units multisplits cassette, floor/ceiling & blower units window units

york air-conditioning products

High Wall On/Off


YVHFZH 09 to 24
A complete range from 2.7 kW to 6.3 kW

NEW

Features
Low noise levels Class A Automatic restart ON/OFF timer Automatic air sweep Service valve protection cover Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Room temperature sensor Fan speed selection Timer setting function Air flow direction setting LCD display Turbo mode

40/41

High Wall On/Off


YVHFZH 09 to 24

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit Type of connection Piping Refrigerant charge Pipe run Length Height Diameter Gas Liquid g m m min./max. min./max. 3/8 1/4 1 250 20 10 1/2 1/4 1 250 20 10 +18C / +43C -7C / +24C W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg Indoor (L/M/H) Outdoor cooling heating V/Ph/Hz kW kW 0.80 0.85 3.30 3.41 A B 480 32 / 35 / 37 50 267 815 165 540 848 320 10 32 1.05 1.06 3.23 3.41 A B 520 33 / 36 / 39 52 283 872 178 540 848 320 11 40 Flare 5/8 3/8 1 800 20 15 5/8 3/8 2 000 30 16 Sizes Sizes kW kW Type YVHFXH 09 YVHFYH 09 2.7 2.8 YVHFXH 12 YVHFYH 12 3.4 3.5 Rotary R410A 230 / 1 / 50 + E 1.63 1.71 3.21 3.21 A C 800 37 / 41 / 45 55 300 960 195 700 1 018 412 13 55 2.00 1.90 3.21 3.41 A B 1 000 47 / 52 / 57 56 330 1 090 208 847 950 412 16 72 YVHFZH YVHFXH 18 YVHFYH 18 5.1 5.5 YVHFXH 24 YVHFYH 24 6.3 6.5

Indoor airflow (high speed) Sound pressure at 1 m

Operating limit - cooling mode Operating limit - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 4 m with initial charge

Accessories
Sizes Electrostatic dedusting filter Silver ion filter Active carbon filter 09 12 Optional Optional Optional 18 24

Available KAHC models with Low Ambient Kit (LAK)

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

High Wall On/Off


EAHC 09 to 24 FS-R
A complete range from 2.5 kW to 6.2 kW

Features
Low noise levels Class A Automatic restart ON/OFF timer Automatic air sweep Service valve protection cover Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer setting function Air flow direction setting LCD display

42/43

High Wall On/Off


EAHC 09 to 24 FS-R

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class cooling heating m3/h dB(A) dB(A) H (mm) Indoor Dimensions Outdoor Indoor unit Outdoor unit Type of connection Piping Refrigerant charge Pipe run Length Height Diameter Gas Liquid g m m min./max. min./max. 3/8 1/4 660 15 10 1/2 1/4 840 20 10 +18C / +46C -7C / +24C W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg Indoor (L/M/H) Outdoor cooling heating V/Ph/Hz kW kW 0.80 0.82 3.21 3.41 A B 350 32 / 35 / 37 50 255 730 174 540 776 320 8 31 1.00 0.99 3.21 3.41 A B 400 32 / 35 / 38 52 265 790 170 540 798 355 9 35 Flare 1/2 1/4 1 150 25 10 1/2 1/4 1 450 25 10 Sizes Sizes kW kW Type EAKC 09 FS-R EAJC 09 FS-R 2.5 2.7 EAKC 12 FS-R EAJC 12 FS-R 3.1 3.4 Rotary R410A 230 / 1 / 50 + E 1.50 1.35 3.21 3.63 A A 750 37 / 41 / 45 55 298 940 200 540 848 360 13 40 1.90 1.90 3.22 3.41 A B 780 38 / 41 / 45 56 298 940 200 680 913 428 13 46 EAHC FS-R EAKC 18 FS-R EAJC 18 FS-R 4.6 5.0 EAKC 24 FS-R EAJC 24 FS-R 6.2 6.5

Indoor airflow (high speed) Sound pressure at 1 m

Operating limit - cooling mode Operating limit - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Accessories
Sizes Electrostatic dedusting filter Silver ion filter Active carbon filter 09 12 Optional Optional Optional 18 24

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

High Wall Multi Split


YEHNZH 18 to 24 (2x1)
A complete range from 5.6 kW to 7.0 kW

Features
Low noise levels Active carbon filter  2 circuits / 2 compressors running in same mode Automatic restart ON/OFF timer Automatic air sweep Service valve protection cover Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer setting function Air flow direction setting LCD display Turbo mode Lock button function

44/45

High Wall Multi Split


YEHNZH 18 to 24 (2x1)

Technical features
INDOOR UNIT (9000 Btu/h) INDOOR UNIT (12000 Btu/h) OUTDOOR UNIT Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input (Cooling) Power input (Heating) EER / COP Energy Class (cooling/heating) Sound pressure at 1 m (ind./out.) Indoor unit Dimensions Outdoor unit Net Weight (Indoor / Outdoor) Piping diameter Pipe run Length Height dB(A) H (mm) W (mm) D (mm) H (mm) W (mm) D (mm) kg Gas Liquid m m min/max min/max V/Ph/Hz kW kW 1.86 1.76 3.01 / 3.41 B/B 30 + 30 / 54 265 790 170 700 1 018 412 9 + 9 / 58 2 x 3/8 2 x 1/4 2 x 20 2 x 10 kW kW Type (Nb) YEHNYH 18 5.6 (2.8 x 2) 6.0 (3.0 x 2) 2 x YEHNXH 09 1 x YEHNXH 09 1 x YEHNXH 12 YEHNYH 21 6.3 (2.8 + 3.5) 6.8 (3.0 + 3.8) Rotary / 2 R410A 230 / 1 / 50 + E 2.09 1.99 3.01 / 3.41 B/B 30 + 29 / 55 265 + 275 790 + 845 170 + 180 700 950 420 9 + 10 / 65 3/8 + 1/2 2 x 1/4 2 x 20 2 x 10 +10C / +48C -7C / +24C 2.32 2.11 3.01 / 3.41 B/B 29 + 29 / 58 275 845 180 700 950 420 10 + 10 / 65 2 x 1/2 2 x 1/4 2 x 20 2 x 10 2 x YEHNXH 12 YEHNYH 24 7.0 (3.5 x 2) 7.2 (3.6 x 2)

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Floor/Ceiling
EOHC 09 to 48 FS
A complete range from 2.5 kW to 13.2 kW

Features
Convertible - floor or ceiling Horizontal and vertical air sweep function Wide angle air distribution Slim profile - flush mounting Low Ambient Kit optional Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

Wired control (optional)


5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

46/47

Floor/Ceiling
EOHC 09 to 48 FS

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class Fuse rating Indoor airflow (high speed) Sound pressure at 1 m Indoor (H/M/L) Outdoor Indoor Dimensions Outdoor Indoor unit Outdoor unit Type of connection Piping Refrigerant charge Pipe run Length Height Diameter Gas Liquid g m m min/max min/max 1/2 1/4 1 100 20 15 1/2 1/4 1 000 20 15 1/2 1/4 1 500 20 15 cooling heating A m3/h dB(A) dB(A) H (mm) W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg cooling heating V/Ph/Hz kW kW 0.89 0.98 2.81 2.85 C D 25 550 45 / 42 / 39 54 695 836 238 540 820 320 27 30 230 / 1 / 50 + E 1.23 1.29 2.85 3.02 C D 25 600 46 / 42 / 38 56 695 836 238 540 820 320 27 40 1.80 2.00 2.89 2.85 C D 25 700 54 / 50 / 46 56 695 836 238 540 820 320 27 40 2.50 2.59 2.88 3.09 C D 25 1 170 50 / 48 / 46 59 600 1 300 188 695 1 018 412 32 59 Flare 5/8 3/8 2 200 30 15 -10C / +43C -15C / +24C 3/4 1/2 3 200 50 30 3/4 1/2 3 550 50 30 3/4 1/2 3 800 50 30 3.50 3.30 2.86 3.33 C C 16 1 800 54 / 51 / 48 58 695 1 590 238 840 1 018 412 42 90 Sizes Sizes kW kW Type EOKC 09 FS ENJC 09 FS 2.5 2.8 EOKC 12 FS ENJC 12 FS 3.5 3.9 Rotary R410A 400 / 3 / 50 + E + N 4.50 4.70 2.67 2.98 D D 16 1 800 54 / 51 / 48 60 695 1 590 238 1 250 1 032 412 42 112 5.00 4.80 2.64 3.02 D D 16 2 100 58 / 55 / 52 63 695 1 590 238 1 250 1 032 412 48 112 EOKC 18 FS ENJC 18 FS 5.2 5.7 EOHC EOKC 24 FS ENJC 24 FS 7.2 8.0 EOKC 36 FS ENJC 36 FS 10.0 11.0 EOKC 42 FS ENJC 42 FS 12.0 14.0 Scroll EOKC 48 FS ENJC 48 FS 13.2 14.5

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Accessories
Sizes Wired control Weekly timer Central control Low Ambient Kit 09 12 18 24 Optional Optional Optional Optional 36 42 48

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Cassette
EKHC 12 to 48 FS
A complete range from 3.5 kW to 14.2 kW

Features
Condensate pump Fresh air intake for sizes 24 to 42 3 fan speeds 600 x 600 mm (size 12 & 18) Auto restart Low noise operation Low Ambient Kit optional Rustproof casing  Blue fin protection (indoor and outdoor units)

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

Wired control (optional)


5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer LCD display

48/49

Cassette
EKHC 12 to 48 FS

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Refrigerant Power supply Power input EER COP Energy Class Indoor airflow Sound pressure Indoor (H/M/L) at 1 m Outdoor Indoor Dimensions Outdoor Panel H/W/D Net weight Indoor unit Outdoor unit Type of connection Piping Diameter Gas Liquid g m m min/max min/max 1/2 1/4 1 000 20 15 1/2 1/4 1 500 20 15 5/8 3/8 2 200 30 15 -10C / +43C -15C / +24C Cooling Heating m3/h dB(A) dB(A) H (mm) W (mm) D (mm) H (mm) W (mm) D (mm) mm kg kg Cooling Heating V/Ph/Hz kW kW 1.15 1.10 3,04 3,27 B C 550 47 / 45 / 43 56 230 600 600 540 820 320 50 / 650 / 650 20 32 230 / 1 / 50 + E 1.85 1.75 2,86 3,26 C C 550 47 / 45 / 43 56 230 600 600 540 820 320 50 / 650 / 650 20 40 2.50 2.50 2,80 3,00 C D 1 180 47 / 45 / 43 59 240 840 840 695 1 018 412 60 / 950 / 950 30 59 Flare 3/4 1/2 3 200 50 30 3/4 1/2 3 550 50 30 3/4 1/2 3 800 50 30 3.50 3.40 2,86 3,24 C C 1 660 53 / 51 / 48 60 320 840 840 840 1 018 412 60 / 950 / 950 38 90 Sizes Sizes kW kW Type EKKC 12 FS ENJC 12 FS 3.5 3.6 EKKC 18 FS ENJC 18 FS 5.3 5.7 Rotary R410A 400 / 3 / 50 + E 4.60 4.80 2,61 2,92 D D 1 660 53 / 51 / 48 60 320 840 840 1 250 1 032 412 60 / 950 / 950 38 112 4.80 5.20 2,75 2,79 D E 1 660 53 / 51 / 48 63 320 840 840 1 250 1 032 412 60 / 950 / 950 32 112 EKKC 24 FS ENJC 24 FS 7.0 7.5 EKHC EKKC 36 FS ENJC 36 FS 10.0 11.0 EKKC 42 FS ENJC 42 FS 12.0 14.0 Scroll EKKC 48 FS ENJC 48 FS 13.2 14.5

Refrigerant charge Max pipe run Length Height

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Accessories
Sizes Wired control Weekly timer Central control Low Ambient Kit 12 18 24 Optional Optional Optional Optional 36 42 48

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Blower
EUHC 12 to 60 FT
A complete range from 3.5 kW to 16.0 kW

Features
Air filter included Condensate pump optional Fresh air intake Indoor unit with centrifugal fan Large distances between indoor and outdoor units Indoor units with high pressure Quiet operation Wired control with weekly timer Infrared remote control Low Ambient Kit optional  Blue fin protection (indoor and outdoor units)

Wired control
5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Weekly timer LCD display

Remote controller
Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep mode Room temperature setting Fan speed selection Timer Air flow direction setting LCD display

50/51

Blower
EUHC 12 to 60 FT

Technical features
Set reference Indoor unit Outdoor unit Cooling capacity Heating capacity Compressor Power supply Power input EER COP Energy Class Indoor airflow External static pressure Sound pressure at 1 m Indoor Outdoor Indoor Dimensions Outdoor Indoor unit Outdoor unit Type of connection Piping Refrigerant charge Pipe run Length Height Diameter Gas Liquid g m m min/max min/max 1/2 1/4 1 000 20 15 1/2 1/4 1 500 20 15 5/8 3/8 2 200 30 15 cooling heating m3/h Pa dB(A) dB(A) H (mm) W (mm) D (mm) H (mm) W (mm) D (mm) Net weight kg kg cooling heating Sizes Sizes kW kW Type V/Ph/Hz kW kW 1.1 1.1 3.18 3.27 B C 600 25 40 / 38 / 36 56 220 913 680 540 820 320 27 32 EUKC 12 FT ENJC 12 FS 3.5 3.6 EUKC 18 FT ENJC 18 FS 5.2 5.7 Rotary 230 / 1 / 50 + E 1.85 1.75 2.81 3.26 C C 840 40 42 / 40 / 38 56 266 1 012 736 540 820 320 36 40 2.60 2.50 2.69 3.20 D C 1 400 80 44 / 42 / 40 59 268 1 270 530 695 1 018 412 37 59 3.70 3.50 2.76 3.20 D C 2 000 150 50 / 48 / 46 60 290 1 226 775 840 1 018 412 57 90 Flare 3/4 1/2 3 200 50 30 -10C / +43C -15C / +24C 3/4 1/2 3 550 50 30 3/4 1/2 3 800 50 30 3/4 1/2 5 000 50 30 4.80 4.90 2.54 2.86 E D 2 000 150 50 / 48 / 46 60 290 1 226 775 1 250 1 032 412 57 112 EUKC 24 FT ENJC 24 FS 7.0 8.0 EUHC EUKC 36 FT ENJC 36 FS 10.2 11.2 EUKC 42 FT ENJC 42 FS 12.2 14.0 Scroll 400 / 3 / 50 + E + N 5.10 4.60 2.58 3.15 E D 2 300 150 53 / 50 / 46 63 290 1 226 775 1 250 1 032 412 57 112 6.30 6.00 2.54 3.08 E D 2 500 150 53 / 50 / 48 64 330 1 226 815 1 250 1 032 412 66 123 EUKC 48 FT ENJC 48 FS 13.2 14.5 EUKC 60 FT ENJC 60 FS 16.0 18.5

Operating limits - cooling mode Operating limits - heating mode

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB Piping length : 5 m with initial charge

Accessories
Sizes Condensate pump Low Ambient Kit Central control 12 18 24 36 Optional Optional Optional 42 48 60

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Window
Y8USE 09 to 24
A complete range from 2.6 kW to 5.0 kW

Features
Super compact design Quiet design Removable and washable panel Infrared control Drying operation Anti cool wind Golden fin condenser Memory function

52/53

Window
Y8USE 09 to 24

Technical features
Models Cooling capacity Heating capacity Power supply Refrigerant Power input EER COP Indoor airflow Sound pressure at 1 m H Dimensions Net weight Stuffing quantity 40 HQ W D m3/h dB(A) mm mm mm kg Set cooling heating Sizes kW kW V/Ph/Hz Type kW kW 0.92 0.73 3.04 3.42 480 50 / 48 / 46 375 560 618 43 342 1.26 1.02 3.04 3.42 730 53 / 51 / 49 428 660 700 57 225 Y8USE 09 2.8 2.5 Y8USE 12 3.8 3.5 230 / 1 / 50 + E R410A 1.76 1.59 3.00 3.00 850 57 / 55 / 53 428 660 770 66 205 1.99 1.83 3.01 3.01 900 58 / 56 / 53 428 660 770 75 195 Y8USE 18 5.3 4.8 Y8USE 24 6.2 5.5

Nominal cooling capacity based on : - Indoor Air Temp. 27C DB / 19C WB - Outdoor Air Temp. 35C DB Nominal heating capacity based on : - Indoor Air Temp. 21C DB - Outdoor Air Temp. 7C DB/6C WB

Manufacturer reserves the rights to change specifications without prior notice.

Minisplit Systems

york air-conditioning products

Information for minisplit installation


Model Size
Power supply Power supply cable size

(mm2)

Interconnection cables (number of cables and sizes)

(mm2)

Maximum pipe run (m)

Maximum height (m)

Piping diameter Liquid - gas

Outdoor unit charged for a piping length of (m)

Extra refrigerant charge for every meter (gr)

High wall Inverter YWHJZH R410A

09 12 18 24 09 12 18 24 09 12 18 24 09 12 18 24 09 12 18 24 18 21 27 30 22 24 28 09 12 18 12 18 24 30 36 42 48 60

Indoor 3 x 2.5 Outdoor 4 x 2.5

YWHJZH 15 20 25 YRHJZH

1/4 - 3/8 10 1/4 - 5/8 5

20 50

High wall Inverter YRHJZH R410A

Indoor 3 x 2.5 Outdoor 4 x 2.5

15 25 EVHC-D 15 20 25 YVHFZH

5 10

1/4 - 3/8 5 1/4 - 1/2

15 20

High wall Inverter EVHC-D R410A

Indoor 3 x 2.5 Outdoor 4 x 2.5

5 10

1/4 - 3/8 5 1/4 - 1/2

30 50

High wall On-Off YVHFZH R410A

Indoor Outdoor

3 x 2.5 3x4

5 x 2.5 6x4

20 30 EAHC-FS-R 15 20 25 EMHC

10 15 16

1/4 - 3/8 1/4 - 1/2 3/8 - 5/8

30 50

High wall On-Off EAHC-FS-R R410A

1/4 - 3/8 10 1/4 - 1/2 5

Indoor Outdoor

3 x 2.5 3x4

5 x 2.5 6x4

30 50

High wall Multisplit EMHC R410A Multisplit Inverter ERJC R410A Console Inverter ECHC-D R410A

Outdoor

3x4

6 x 2.5

15 *

1/4 -3/8

5*

30

ERJC Outdoor 3x4 4 x 1.5 15 * ECHC-D Indoor 4 x 2.5 4 x 0.25 15 25 EOHC-D-R / EKHC-D-R / EUHC-D-R Ind: 3 x 1.5 Out: 3 x 2.5 Outdoor & Indoor Ind: 3 x 2.5 Out: 3 x 4 Ind: 3 x 2.5 Out: 3 x 6 Ind: 3 x 2.5 Out: 5 x 4 4 x 0.25 50 30 3/8 - 1/4 EOHC / EKHC / EUHC 20 15 30 3/8 - 5/8 5 120 1/4 - 3/8 1/4 - 1/2 30 60 10 1/4 - 3/8 1/4 - 1/2 5 20 10 * 1/4-3/8 ** 5* 40

Floor/Ceiling Inverter EOHC-D-R Cassette Inverter EKHC-D-R Blower Inverter EUHC-D-R R410A

Floor/Ceiling EOHC Cassette EKHC Blower EUHC R410A

09 12 18 24 36 42 48 60 Outdoor & Indoor

Ind: 3 x 1.5 Out: 3 x 2.5 Ind: 3 x 1.5 Out: 3 x 4 Ind: 3 x 1.5 Out: 3 x 6 Ind: 3 x 1.5 Out: 5 x 2.5 2 x 0.25

20 30

15

1/4 - 1/2 3/8 - 5/8

30 60

50

30

1/2 - 3/4

120

* Each indoor unit ** next indoor unit Confirm about data in the technical documentation.

54/55

Load calculation
Customer Telephone Adress Termical loads not exposed to sunlight WINDOWS exposed to sunlight exposed to sunlight with curtains exposed to sunlight with awnings exposed to sunlight and insulated OUTDOOR WALLS exposed to sunlight non insulated not exposed to sunlight and insulated not exposed to sunlight non insulated INDOOR WALLS * insulated CEILING OR ROOF * not insulated insulation under the roof not insulation under roof FLOOR * FRESH AIR PERSONS INSIDE THE ROOM WORKING ELECTRICAL EQUIPMENT insulated not insulated PARAMETERS m m
2 2

Date Type of installation

Project

FACTOR x x x x x x x x x x x x x x x x x x 50 180 135 90 9 23 7 12 10 5 12 10 24 7 10 4,5 144 1 = = = = = = = = = = = = = = = = = =

CAPACITY

m2 m2 m2 m m m
2 2 2

m2 m2 m m m
2 2 2

m2 m
2

m3/h pers. W

NEEDED COOLING CAPACITY


* To not consider if they are next to climatisated area.

Important: This is a simplified method to obtain an approximate value of cooling capacity, as long as the climatic conditions are not extreme. Only for cooling calculation.

Minisplit Systems

york air-conditioning products

56/57

VRF Systems
yds-c r410a indoor unit types

york air-conditioning products

YDS Variable refrigerant flow system


YDMH 100, 140, 252, 280, 335, 400, 450 C
Cooling capacities 10.0 kW to 180.0 kW

YDS System
Capacities from 10 to 180 kW Operating range of nominal power (10% - 100 %) Digital Scroll Technology Low noise levels High performance Flexible and quickly installation

Comfort Quality
Cooling and heating Connection up to 64 indoor units per refrigeration circuit (4 outdoor units) Complete range in R410A Reduced space of ground Is appropriate particularly for existing buildings Cooling to -10C to +48C (outdoor temperature) Heating to -15C to +30C (outdoor temperature)

58/59

YDS Variable refrigerant flow system


YDMH 100, 140, 252, 280, 335, 400, 450 C

Technology of future: Digital Scroll Compressor operation


The Digital Scroll Compressor uses a simple and effective method to modulate the capacity of an AC, giving unparalleled performance in the modulation field. To modulate the capacity the Digital Scroll operates in two stages, the loaded state in which the compressor works as a normal Scroll compressor at full capacity and mass flow, and the unloaded state, where there is not capacity and mass flow. During the unloaded state there is a separation between the scrolls. Once the scrolls separate, any gas passing through is no longer compressed. Changing the cycle time (Loaded state time and Unloaded state time) determines the capacity modulation of the compressor.

Modulation chamber Bleed hole Lift piston assembly

Spring Solenoid valve

With the introduction of the third generation of the YDS systems, we offer one of the biggest capacity capabilities in the VRF market. Cooling capacity from 10 kW to 180 kW is now available. This capacity is now possible to achieve through connecting from 4 outdoor units together. The range is based on 2 outdoor units of 10 kW and 14 kW capacity (Digital scroll compressor) and 4 basic modules of different capacities from 25.2 kW to 45 kW, each basic module including a Digital Scroll compressor and a conventional compressor. You can connect up to 64 indoor units in one

refrigerant circuit. More than 30 models are available, high walls, cassettes, duct and floor/ceiling types. The individual setting is done by infra red or wired remote control. Additionally it is possible to use a central controller.
140.0 - 180.0 kW

10.0 - 14.0 kW

25.2 - 45.0 kW

96.0 - 135.0 kW

53.2 - 90.0 kW

Manufacturer reserves the rights to change specifications without prior notice.

VRF Systems

york air-conditioning products

YDS Variable refrigerant flow system


YDMH 100 to 900
YDS Technical features - Single module outdoor unit
Model YDMH 100C YDMH 140C YDMH 252C YDMH 280C YDMH 335C YDMH 400C YDMH 450C

Cooling capacity Heating capacity Air flow Noise level at 1 m


Electrical features

kW kW m3/h dB(A)

10.00 12.00 6 000 55

14.00 16.00 6 000 55

25.20 27.00 10 000 58

28.00 31.50 10 000 58

33.50 35.00 10 000 58

40.00 43.00 14 000 60

45.00 47.00 14 000 60

Power supply Power input cooling Running current cooling Power input heating Running current heating Compressor
Dimensions and Weight

3/N/ 400V 50Hz kW A kW A Type 3.50 8.50 3.41 7.60 Digital Scroll 4.50 8.50 4.40 7.60 7.31 12.5 7.01 12.00 8.05 14.60 8.14 14.50 9.68 17.30 9.12 16.40 Digital Scroll and Fix Scroll 11.53 20.20 11.17 19.50 12.86 23.00 12.08 21.40

Height x Width x Length Weight


Piping connections

mm kg

1245 x 940 x 340 117

1245 x 940 x 340 117

1630 x 980 x 800 245

1630 x 1380 x 830 382

Gas Liquid Refrigerant charge Type kg 4.10

18mm / 3/4 10mm / 3/8 4.10 11.0

28mm / 1 1/8 12mm / 1/2 R410A 11.00 11.00 16.00

35mm / 1 3/8 16mm / 5/8 16.00

Piping length / Height difference

Max. piping length Max. height difference Max. number of indoor units

m m

70 8 6

70 8 8

175 70 13

175 70 16

175 70 20

175 70 20

175 70 20

YDS Technical features - Outdoor units with two module combinations


Model Module combinations YDMH 532C 1x YDMH252 1x YDMH280 YDMH 560C 2x YDMH280 YDMH 615C YDMH 680C YDMH 730C YDMH 785C YDMH 850C YDMH 900C 1x YDMH280 1x YDMH280 1x YDMH280 1x YDMH335 1x YDMH400 2x YDMH450 1x YDMH335 1x YDMH400 1x YDMH450 1x YDMH450 1x YDMH450

Cooling capacity Heating capacity Noise level at 1 m


Electrical features

kW kW dB(A)

53.2 58.5 62

56.00 63.00 62

61.50 66.50 62

68.00 74.50 62

73.00 78.50 62

78.50 82.00 63

85.00 90.00 63

90.00 94.00 63

Power supply Power input cooling Power input heating


Dimensions and Weight

3/N/ 400V 50Hz kW kW 15.36 15.15 16.10 16.28 17.73 17.26 19.58 19.31 20.91 20.22 22.54 21.20 24.39 23.25 25.72 24.16

Height x Width x Length Weight

mm kg

1630 x 1960 x 800 490

1630 x 2360 x 830 627

1630 x 2760 x 830 764

Piping size between the outdoor unit and the first branch

Gas Liquid
Refrigerant piping

35mm / 1 3/8 18mm / 3/4

42mm / 1 5/8 22mm / 7/8

Piping 1 Piping 2 Connection between modules (out. groups) Max. number of indoor units 20 20 YDSA / RD102 20 20

16mm / 5/8 18mm / 3/4 YDSA / RD103 20 20 32 32

60/61

YDMH 960 to 1800


YDS Technical features - Outdoor units with three module combinations
Model Module combinations YDMH 960C YDMH 1010C YDMH 1065C YDMH 1130C YDMH 1180C YDMH 1235C YDMH 1300C YDMH 1350C YDMH280 1x YDMH280 1x YDMH280 1x YDMH335 1x YDMH400 2x YDMH280 2x YDMH280 1x 1x YDMH335 1x YDMH400 2x 1x YDMH400 1x YDMH450 1x YDMH450 2x YDMH450 2x YDMH450 3x YDMH450 YDMH450 1x YDMH450

Cooling capacity Heating capacity Noise level at 1 m


Electrical features

kW kW dB(A)

96.00 106.00 64

101.00 110.00 64

106.50 113.50 64

113.00 121.50 64

118.00 125.50 64

122.50 129.00 64

130.00 137.00 64

135.00 141.00 64

Power supply Power input cooling Power input heating


Dimensions and Weight

3/N/ 400V 50Hz kW kW 27.63 27.45 28.96 28.36 30.59 29.34 32.44 31.39 33.77 32.30 35.40 33.28 37.25 35.33 38.58 36.24

Height x Width x Length Weight

mm kg

1630 x 3340 x 830 872

1630 x 3740 x 830 1.009

1630 x 4140 x 830 1.146

Piping size between the outdoor unit and the first branch

Gas Liquid
Refrigerant piping

42mm / 1 5/8 22mm / 7/8

Piping 1 Piping 2 Connection between modules (out. groups) Max. number of indoor units 32 1x YDSA / RD102 + 1x YDSA / RD01 32 32 40

16mm / 5/8 18mm / 3/4 1x YDSA / RD103 + 1x YDSA / RD01 40 40 40 40

YDS Technical features - Outdoor units with four module combinations


Model Module combinations YDMH 1405C YDMH 1455C YDMH 1520C YDMH 1570C YDMH 1630C 1x YDMH280 3x YDMH450 YDMH 1685C YDMH 1750C YDMH 1800C YDMH335 2x YDMH335 3x YDMH335 3x YDMH335 2x YDMH400 1x YDMH400 1x YDMH450 1x 1x YDMH450 2x YDMH450 1x YDMH335 1x YDMH400 3x YDMH450 3x YDMH450 4x YDMH450

Cooling capacity Heating capacity Noise level at 1 m


Electrical features

kW kW dB(A)

140.50 148.00 65

145.50 152.00 65

152.00 160.00 65

156.00 164.00 65

163.00 172.50 65

168.50 176.00 65

175.00 184.00 65

180.00 188.00 65

Power supply Power input cooling Power input heating


Dimensions and Weight

3/N/ 400V 50Hz kW kW 40.57 38.53 41.90 39.44 43.75 41.49 45.08 42.40 46.63 44.38 48.26 45.36 50.11 47.41 51.44 48.32

Height x Width x Length Weight

mm kg

1.630 x 4.320 x 830 1.117

1.630 x 4.720 x 830 1.254

1.630 x 5.120 x 830 1.391

1.630 x 5.520 x 830 1.528

Piping size between the outdoor unit and the first branch

Gas Liquid
Refrigerant piping

54mm / 2 1/8 28mm / 1 1/8

Piping 1 Piping 2 Connection between modules (out. groups) Max. number of indoor units 50 50 1x YDSA / RD102 + 2x YDSA / RD01 50 50

16mm / 5/8 18mm / 3/4 1x YDSA / RD103 + 2x YDSA / RD01 50 64 64 64

VRF Systems

YDS Variable refrigerant flow system

york air-conditioning products

YDS Technical features indoor units


High wall (EXV integrated)
Model YDHWC022C YDHWC028C YDHWC036C YDHWC045C YDHWC056C

Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Starting current HxWxD Dimensions and Weight Weight Gas Piping Liquid

kW kW m3/h dB(A) V/Ph/Hz A mm kg

2.2 2.6

2.8 3.2 580 / 500 / 420 35 / 32 / 29 2.5 290 x 915 x 210 12

3.6 4.0

4.5 5.0 900 / 760 / 650 40 / 38 / 34

5.6 6.3

230 / 1 / 50 + N + E 3.3 315 x 1070 x 210 15 12mm / 1/2 6mm / 1/4

Cassette
Model YDCS022C YDCS028C YDCS036C YDCS045C YDCS056C

Cooling Capacity Heating Air flow Noise level at 1 m H / L Power supply Electrical features Starting current HxWxD Dimensions and Weight Weight HxWxD Panel Weight Gas Piping Liquid

kW kW m3/h dB(A) V/Ph/Hz A mm kg mm kg

2.2 2.6

2.8 3.2 38 / 35

3.6 4.0 570 / 400 230 / 1 / 50 + N + E 3.6 254 x 580 x 580 18 30 x 650 x 650 3 12mm / 1/2 6mm / 1/4

4.5 5.0 39 / 36

5.6 6.3

18

18

24

24

16mm / 5/8 10mm / 3/8

Cassette
Model YDCL056C YDCL071C YDCL080C YDCL090C YDCL112C YDCL140C

Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Starting current HxWxD Dimensions and Weight Weight HxWxD Panel Weight Gas Piping Liquid

kW kW m3/h dB(A) V/Ph/Hz A mm kg mm kg

5.6 6.3 950 / 800 / 650 42 / 38 / 35 3.6

7.1 8.0 1 220 / 1 010 / 820 48 / 45 / 42

8.0 9.0

9.0 10.0 1 540 / 1 300 / 1 120 53 / 48 / 45 230 / 1 / 50 + N + E

11.2 12.5

14.0 15.0 1 802 / 1 483 / 1 284 48 / 45 / 43

4.2 230 x 840 x 840 30 46 x 950 x 950 6 16mm / 5/8 10mm / 3/8

27

6.0 300 x 840 x 840 36

62/63

Convertible console floor/ceiling


Model YDFC036C YDFC045C YDFC056C YDFC071C YDFC080C YDFC090C YDFC112C YDFC140C

Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Starting current HxWxD Dimensions and Weight Weight Gas Piping Liquid

kW kW m3/h dB(A) V/Ph/Hz A mm kg

3.5 4.0 650 / 570 / 500

4.7 5.1

5.3 6.2 800 / 600 / 500 43 / 41 / 38 5.4 660 x 995 x 198 29

7.0 8.2

4.7

12mm / 1/2 6mm / 1/4

7.9 8.8 9.4 10.6 1 400 / 1 200 / 1 000 45 / 43 / 40 230 / 1 / 50 + N + E 6.2 660 x 1 285 x 198 37 16mm / 5/8 10mm / 3/8

11.7 14.1 13.2 15.5 2 000 / 1 800 / 1 600 47 / 45 / 42 7.7 680 x 1 670 x 240 54

Floor standing
Model YDEFS022C YDEFS028C YDEFS036C YDEFS045C YDEFS56C YDEFS071C YDEFS080C

Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Electrical features Power supply HxWxD Dimensions and Weight Weight Gas Piping Liquid

kW kW m3/h dB(A) V/Ph/Hz mm kg

2.2 2.8 2.6 3.2 530 / 456 / 400 569 / 485 / 421 37 / 35 / 33 625 / 1 000 / 220 30

3.6 4.0 624 / 522 / 375 39 / 37 / 35

4.5 5.0 660 / 542 / 440 39 / 37 / 35 230 / 1 / 50 + N + E 625 / 1 200 / 220 37

5.6 6.3 1 150 / 970 / 830 41 / 39 / 37

7.1 8.0 8.0 9.0 1 380 / 1 100 / 870 1 332 / 1 212 / 1 023 43 / 41 / 38 625 / 1 500 / 220 44 16mm / 5/8 10mm / 3/8

12mm / 1/2 6mm / 1/4

Floor standing concealed


Model YDCFS022C YDCFS028C YDCFS036C YDCFS045C YDCFS56C YDCFS071C YDCFS080C

Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Electrical features Power supply HxWxD Dimensions and Weight Weight Gas Piping Liquid

kW kW m3/h dB(A) V/Ph/Hz mm kg

2.2 2.8 2.6 3.2 530 / 456 / 400 569 / 485 / 421 37 / 35 / 33 544 / 840 / 212 26

3.6 4.0 624 / 522 / 375 39 / 37 / 35

4.5 5.0 660 / 542 / 440 39 / 37 / 35 230 / 1 / 50 + N + E 544 / 1 036 / 212 29.5

5.6 6.3 1 150 / 970 / 830

7.1 8.0 1 380 / 1 100 / 870 41 / 39 / 37

8.0 9.0 1 332 / 1 212 / 1 023

544 / 1 336 / 212

12mm / 1/2 6mm / 1/4

545 / 1 336 / 212 36 16mm / 5/8 10mm / 3/8

Blower
Model YDDN022C YDDN028C YDDN036C YDDN045C YDDN056C YDDN071C YDDN080C YDDN090C YDDN112C YDDN140C

Cooling Capacity Heating Air flow Noise level at 1 m H / M / L Power supply Electrical features Static pressure HxWxD Dimensions and Weight Weight Gas Piping Liquid

kW kW m3/h dB(A) V/Ph/Hz Pa mm kg

2.8 3.6 3.2 4.0 570 / 400 / 320 34 / 32 / 30 35 / 33 / 31 10 210 x 955 x 385 15 12mm / 1/2 6mm / 1/4

2.2 2.6

4.5 5.6 7.1 8.0 5.0 6.3 8.0 8.4 1 160 / 1 100 / 950 1 400 / 1 100 / 900 45 / 41 / 38 46 / 44 / 42 230 / 1 / 50 + N + E 40 298 x 1 000 x 800 37.2 16mm / 5/8 10mm / 3/8

9.0 10.0

11.2 14.0 12.5 15.0 1 800 / 1 500 / 1 200 47 / 45 / 43 48 / 46 / 44 70 298 x 1 350 x 800 51.4

VRF Systems

york air-conditioning products

Remote Controllers
R05 Remote Controller
Light background, LCD display screen, clock function, ON / OFF / Temperature setting / Mode setting / Fan speed setting / Horizontal swing setting functions. Using for the Floor/Ceiling units.

R51 Remote Controller


LCD display, clock function, ON / OFF / Temperature setting / Mode setting / Fan speed / Swing etc. Using for all the indoor units except Floor/Ceiling units.

Wired Controller & Weekly Timer


AMR01Y Wired Controller
ON / OFF / Mode setting / Temp. setting / Fan speed / Time setting / Swing, etc. Temp sensor built-in.

AMR02M Weekly schedule timer


Control one indoor unit. Note: Weekly schedule timer and indoor CCM cannot be used simultaneity

Central Control Monitor


AMR02Y Outdoor CCM
Max. 32 outdoor units control.

AMR03Y Indoor CCM


Max. 64 indoor units control; New mode lock function.

AMR09Y Indoor CCM


Max. 64 indoor units control. New weekly timer function.

For BMS connection ckeck with your JCI representative.

64/65

Communication system connection Communication control connection

Refrigerant collector

Indoor unit power supply

Outdoor unit power supply

Central control

Infrared remote control

Infrared remote control

Infrared remote control

Wired control

Infrared remote control

YORK System YDS


The YORK system with Digital Scroll is working like the VRF principleand offers you economical airconditioning system for projects, which are requiring more capacity than the normal split and multi split solutions. The lengths for the connecting tubes between the indoor and outdoor have been prolonged, which brings you more flexible solutions for complex air-conditioning projects.

B C

A Real length of refrigerant piping : 150 m. B Maximum difference in height : 70 m. C Maximum difference in height between 2 indoor units : 15 m.

VRF Systems

YDS System - System Diagram

CD Rom 2012 :

Commercial Leaflets, Technical Library, Software Tools and more...

CD available at Johnson Controls office

york air-conditioning products

m-cd-g2012

Residential & Light Commercial 2012

Minimum system requirements


Operating system Windows 98 or better Pentium II processor or superior 32 MB of RAM Screen resolution 800 x 600 pixels, 16 bits To view all pdf files, the Adobe Acrobat Reader program is required. If said program is not installed, install the one included in this CD-ROM.

Multi-language Technical Information

easy-direct-clear

PUBL-6910 E-CAT-MIN-G2012 http://www.johnsoncontrols.co.uk

2012 Johnson Controls, Inc.

www.johnsoncontrols.com

Potrebbero piacerti anche