AXIOM Artis U The little big one for universal angiography applications

s
medical

AXIOM Artis U The little big one for universal angiography applications

The AXIOM Artis U has the power, strength and image quality of an angiographic suite with the footprint and maneuverability of a portable C-arm for a dedicated interventional room. The system is intended to support a wide field of applications, e.g., angiographic interventions, cardiac interventions and GI procedures. The AXIOM Artis U provides a state-of-the-art imaging system that can be configured from single exposure acquisition up to 30 f/s for cardiac applications. The imaging system provides exceptional image management to meet the needs of any IT department for seamless integration. The AXIOM Artis concept is based on four main pillars: Easy handling Outstanding image quality Maximized radiation protection Optimal networking These four elements enable the user to optimize the clinical workflow in the field of cardiology, angiography, neuroangiography and various nonvascular procedures. The flexible configuration of the system makes it possible to control the system either in the examination room or outside of the control room*. System Highlights Gantry System: Movable C-arm system Operation: Complete ergonomic system control in the examination room with integrated generator and imaging system control syngo operation in the examination room and in the control room Image acquisition system: Choice between two high-resolution image intensifier sizes: 23 cm I.I. with three modes, 33 cm I.I. with four modes for improved detail recognition Full-size CCD TV system with digital imaging chain 2

Image processing system: Digital imaging system with FLUOROSPOT Compact Standardized platform with syngo -based user interface Imaging modes ranging from single frame to series acquisition with frame rates from 0.5 to 8 frames/second in 15 f/s with 1k2 or 30 f/s with 1024 x 512/10-bit matrix Online DDO* for fluoroscopy and acquisition Pulsed fluoroscopy Expanded CARE radiation protection Comprehensive DICOM 3 functionality Integrated CD burner* X-ray generation: High frequency generator with CAREMATIC Choice of 65 kW or 80 kW* Automatic exposure control IONTOMAT PN Operation of the generator integrated into the imaging system Dual-focus, high performance X-ray tube assembly with low-noise air-cooling High performance focal spot for optimal image quality Display and display carrier: One or two* 18 (46 cm diagonal) TFT highcontrast black/white flat display for flicker-free image on a movable display trolley In the trolley: integrated drawer with keyboard and mouse** Control room*: Additional 18 TFT flat-screen monochrome display Keyboard and mouse 2nd footswitch for X-ray release

** Option ** Without control room option

AXIOM Artis U Technical Data

Stand Orbital movement Swivel range Immersion depth Horizontal travel BV Angulation Vertical travel Source I.I. distance Imaging system High resolution, digital imaging system with innovative image display, DICOM network connection and syngo -based user interface Tableside control for system operation of all important imaging system functions, fluoro and acquisition parameters, filters, collimators and selection of organ programs. Can be mounted directly at the accessory rail of the patient table or put on the monitor trolley Reference image*: Storage and direct access to reference images on a second flat display in the examination room DDO (dynamic density optimization) for real-time harmonization of fluoroscopy, native series and single images* Real-time edge enhancement, positive/negative image display, windowing, contrast/brightness, electronic shuttering, image shift (roaming), vertical and horizontal image reversal, image rotation, zoom functions Fluoro Loop*: Storage of fluoroscopy images and scenes up to 512 images. Stores fluoroscopy images during fluoroscopy as well Fast, direct access to all series, individual images, and photo files via MULTIMAP, in both the examination room and the control room* Image storage capacity: 40,000 images in 512 matrix or 10,000 images in 1k matrix Standard video output for video recorder* or video printer* Paper printer output for printing images (not for diagnostics), examination protocols and patient data via PostScript printer level 2*. In the U.S., paper printouts should not be used for diagnosis, unless the PostScript printer has specifically received 510 (k) clearance for this purpose. + 90 to 45 10 87 cm 20 cm 33 cm 145 38 cm 110 cm 23 cm 190 28 cm 100 cm

** Option ** Scheduled for later release

Operating modes Digitally pulsed fluoroscopy with 3, 7.5 or 15 p/s and continuous fluoroscopy with 30 f/s in 1k/10 bit and digital real-time filtering, noise reduction through sliding weighted averaging DR Digital Radiography with 1k/10-bit matrix, digital filtering, single image and series native acquisitions with 0.5, 1, 2, 3, 4, 6 or 8 f/s DSA* Digital subtraction angiography with pixel shift, remasking, roadmapping, peak opacification (max. and min. opac.), landmarking in 1k-matrix with real-time filtering and 0.5, 1, 2, 3, 4 or 6 f/s* Cardiac acquisition* Cardiac acquisition with 15 f/s, acquisition and storage in 1k 2 matrix Cardiac acquisition with 30 f/s, acquisition and storage in 1024 x 512 matrix Vascular Analysis Measurement program integrated into the image system for objective, exact, and reproducible vascular analysis. With automatic contour recognition, stenosis quantification, distance and angle measurement and different calibration methods* DICOM 3 Network Interfaces DICOM Send/StC* Network interface in DICOM 3 standard for DICOM-3-compatible image communication network Feedback from the image archive (StC = Storage Commitment) DICOM Print* For connection to a network laser camera or printer DICOM Query/Retrieve* Retrieve images from a patient image archive DICOM Get Worklist/MPPS* Get Worklist function for importing patient data from a data management system (RIS/HIS) Modality Performed Procedure Step (MPPS): send examination statistics and dose information to a patient data management system CD Recorder* CD drive for digital image storage on a CD-ROM for offline data exchange in DICOM 3, TIFF and AVI formats

AXIOM Artis U Technical Data

CARE CAREMATIC CAREMATIC automatic X-ray control system for fully automatic calculation and optimization of exposure data based on fluoroscopy values CAREFILTER Three-level adaptive Cu-prefiltration for reducing skin dose; configured in organ program or automatically guided selection depending on the absorption of the object Filtration levels 0.1, 0.2, 0.3 mm Cu CAREVISION Pulsed fluoroscopy with reduced pulse frequencies from 3.0, 7.5, 15 p/s. Pulse frequency adjusted to the requirements of each application for significant reduction of radiation exposure, particularly during interventions CAREPROFILE* Radiation-free positioning of primary and semi-transparent collimators via graphic display in LIH-image on the image monitor CAREWATCH* Electronic unit with measurement chamber integrated into the collimator housing for acquisition of area dose product or skin dose displayed on the image system monitor Different displays can be configured for fluoroscopy and for fluoro pause: During fluoro During fluoro pause Skin dose rate Accumulated skin dose, or area dose product or percentage of a configurable dose limit value (amount of fluoro and acquisition)

* Option

X-ray TV system High-resolution digital X-ray TV system with maintenance-free 1k CCD-camera chip, max. 69 dB Operation In the examination room Moveable cart with four casters and brake One or two high-contrast monochrome flat displays, drawer with keyboard and mouse Acoustic alarm and two radiation displays Ergonomic foot switch for triggering fluoroscopy and acquisition TSC (Tableside control) for all important functions of the image system, acquisition and fluoroscopy parameters incl. organ programs and collimator control. The TSC can be mounted at the table or on the trolley. In the control room* Control room with additional high-contrast monochrome flat display Extender for keyboard and mouse use in control room: Input of patient data and post-processing can be performed outside the examination room Ergonomic foot switch for triggering fluoroscopy and acquisition: 2nd X-ray release and live-image display is possible without dose burden for the examiner Data display DSB 1803-DC 18 TFT high-contrast black/white flat display for flicker-free, distortion-free live and reference image display in X-ray diagnostics as well as for interventional, therapeutic procedures Light weight, high luminosity and contrast values Diagonal screen measurement Image display Typical brightness Maximum brightness Contrast ratio Horizontal viewing area 18 (46 cm) 1280 x 1024 450 cd/m2 600 cd/m2 400 : 1 160

AXIOM Artis U Technical Data

X-ray image intensifiers Depending on the diagnostic and therapeutic focus, 23 cm or 33 cm I.I. are available with high dynamics for superselective and survey exposures The high contrast and excellent modulation properties allow display of the finest details Cesium iodide input screen for high quantum absorption to generate minimal quantum noise Precision electronic optics with minimal image distortion and consistent high resolution across the entire image field Anti-reflective coating and glare trap Semiconductor measurement fields for dose control Beam quality according to IEC 61262-5 DQE (ICE 61262-5) > 65% I.I. laser light localizer for radiation-free positioning* Image intensifier 23 cm I.I. formats Minimum resolution (lp/mm) Removable grid Image intensifier 33 cm I.I. formats Minimum resolution (lp/mm) Removable grid Collimator Angio collimator with iris and square collimator, wedge-shaped diaphragm blades for DSA and cardiology applications and graduated finger filter Independent rotation and shift of the filter blades Card collimator for configuration with 23 cm I.I. with a rectangular blade and with a wedge-shaped filter diaphragm (scheduled for later release) Tube OPTITOP 150/40/80 HC-100 Nominal voltage (IEC 60613) 150 kV Focal spot (IEC 60613) Output (IEC 60613) Cold output (OW) Anode angle (IEC 60788) Anode heat storage capacity Anode drive Total filtration (IEC 60601-1-3) 0.6 40 kW 52 kW 12 580,000 J (783,000 HU) 150 Hz (3-phase current) 2.5 mm Al 1.0 80 kW 103 kW 33 cm 3.8 Pb 17/70 22 cm 4.6 16 cm 5.0 13 cm 5.8 23 cm 4.6 Pb 15/80 16 cm 5.2 12 cm 5.8

* Option

Generator POLYDOROS SX 65 or POLYDOROS SX 80 Microprocessor controlled HF-generator with automatic dose regulation for radiography and fluoroscopy Generator control is completely integrated into the image system Up to 25 organ programs for storage of acquisition parameters POLYDOROS SX 65 Power rating Fluoroscopy Acquisition Minimal pulse width POLYDOROS SX 80* Power rating Fluoroscopy Acquisition Minimal pulse width Remote Service Preparation for Siemens Remote Service SRS: Hardware and software remote diagnostics Remote system configuration, e.g., addition of a DICOM node, early warning system for ensuring system operation Installation Data Rated voltage Power consumption Room size Room height Ambient conditions (operation) Examination and control room Temperature range: Relative humidity: Air pressure: + 10C to + 35C 15 75% below dew point 700 hPa to 1060 hPa 3/N/PE ~ 400/440/480 V ( 10%) at 50Hz/60Hz; 440/480 V ( 10%) possible with optional power transformer* max. 145 kVA min. 400 x 450 cm min. 250 cm 80 kW (800 mA at 100 kV) acc. to IEC 601-2-7 40 kV to 150 kV 0.1 mA to 100 mA up to 1,000 mA 4 ms 65 kW (650 mA at 100 kV) acc. to IEC 601-2-7 40 kV to 150 kV 0.1 mA to 100 mA up to 800 mA 4 ms

System weight AXIOM Artis U FLUOROSPOT Compact Trolley POLYDOROS SX 65/80 approx. 410 kg approx. 80 kg approx. 110 kg approx. 290 kg

AXIOM Artis U Technical Data

Room layout (mm)

10

System view (mm)

145/190 145/190

1100 / /1000 BV 33 / BV 23

11

The information in this document contains general descriptions of the technical options available, and may not always apply in individual cases. The required features should therefore be specified in each individual case at completion of contract. Siemens reserves the right to modify the design and specifications contained herein without prior notice. Please contact your local Siemens sales representative for the most current information. Original images always lose a certain amount of detail when reproduced. In the interest of complying with legal requirements concerning the environmental compatibility of our products (protection of natural resources and waste conservation), we recycle certain components. Using the same extensive quality assurance measures as for factory-new components, we guarantee the quality of these recycled components.

CAUTION
LASER RADIATION DO NOT STARE INTO BEAM
PEAK POWER < 1 mW WAVE LENGTH 540 - 700 mm CLASS II LASER PRODUCT

(For U.S. and Canada)

Siemens AG Wittelsbacherplatz 2 D-80333 Muenchen Germany Headquarters Siemens AG, Medical Solutions Henkestr. 127, D-91052 Erlangen Germany Telephone ++49 9131 84-0 www.siemens.com/medical Contact Address Siemens AG, Medical Solutions Angiography, Fluoroscopic and Radiographic Systems Siemensstr. 1, D-91301 Forchheim Germany Telephone ++49 9191 18-0

Siemens Medical Solutions that help

2005 Siemens Medical Solutions Order No. A91001-M1400-G936-3-7600 Printed in Germany AX CRM NA 03053