Sei sulla pagina 1di 4

EWSD Q.1. Fill in the blanks (a) (b) (c) (d) Q.2.

DLUC0 & DLUC1 work on load sharing basis. SN0 & SN1 work on hot standby basis. MB(0) & MB(1) work on load sharing basis. BAP(0) & BAP(1) work on hot standby basis for O&M functions. (load sharing/hot standby) (7) (4)

Fill in the blanks (a) The channel registers are available in CP , whereas the call registers are available in GP. (b) (c) During the speech phase, metering information is stored in GP.

The DTMF digits during normal exchange operation are stored/ processed in CRP. whereas during stand-alone operation of R-DLUs EMSP module will be used for this purpose. (d) (e) Q.3. The load parameter to be used for creation of an LTG for connecting a line unit via V5.2 interface will be 52. Maximum number of PDCs used for connecting the DLUD with LTGs is 4 whereas this figure will be 16 if we are to connect DLUG to the LTGs. (4)

True/False

(a) If DLUC0 fails, DLUC1 will process the information for DIUD0 also. - False (b) During normal operation both the BAPs handle O&M functions & their share of call processing functions ? - False (c) CAP can replace the functionality of BAP SPARE -False (d) In an R-DLU, under normal operation the intra-DLU calls (Calls within the DLU) will be handled by SASC (Stand-alone service controller). -False Q.4. Where do we extend fire and air-conditioning alarms in the main exchange? (Mention the Unit name and the card name). SYPD, RM:EA Can we extend these alarms from Remote DLU sites also? If yes, on which card? Yes, ALEX Q.5. What devices can be connected via IOP UNI One O&M terminal (OMT or BCT boot or Netm Boot), MDD, MOD &MTD (2) (1) (4)

Q.6.

Name the functional units of BAP / CAP / IOC.

(3)

Processing Unit (duplicated) , Local Memory, Common Interface and Interface to the bus system for Input/ Output Control (active only when used as an IOC) Q.7. Calculate for a 78 LTG exchange with 78 Signalling Links connected to CCNC (8+2)

(a) the modules in a single plane of SN (B) Modules TSMB LISB SSM8B SSM16B SGCB TSG-0 8 4 1 TSG-1 3 4 1 SSG-0 8 2 1

(b) the number of racks for SN (B) = Three Q.8. What types of message exchanges (between which processors) are handled by MB? (4) 1. 2. 3. 4. Q.9. GP GP GP SGC CP CCNC GP CP

For a 200-LTG exchange, How many MBGs will be required ? How many MBU:LTGs will be required ?

2x2 4x2

(1) (1) (3)

Which MBU numbers will be given in the plane -0 of this exchange? MBUL MBUS Q.10. : 0-0, 0-1, 0-2, 0-3 : 0-1, 0-1

How will you diagnose MBU:LTG ? CONF MBUL : MB= , MBUL= DIAG MBUL : MB= , MBUL= , OST=MBL ; ;

(2)

Q.11.

In connection with Digit Transfer Report from LTG0-2 to LTG1-2., answer the following questions: (4) Which time slot is used on the SDC connecting LTG to the SN ? 0 Which side of the SN will be used for the active message channel ? 0 Which side of the MB will be used for the active message channel ? 0 Which time slot is used on the SDC connecting SN and MB ? 4 In which unit will you find a SILCB module ? What is the function performed by it ? (3) GP It handles the exchange of messages with DLU/PA. It functions as an Input/ Output Processor. The transmission protocols are based on HDLC procedure. On the LTG side, the SILC completes the layer-2 functions of signaling protocol (synchronization, error detection, error handling) and thereby guarantees secure message exchange between peripheral units (DLU or ISDN PA) and the GP. On which highway does the message information for LTGs go (3)

Q.12

Q.13.

(a) between LTG and SN (b) between SN and MBU:LTG (c) between MB and IOP:MB Q.14

SDC:LTG SDC:TSG B:MBG (4)

Which functional units in EWSD are connected to the IOP:MB ? MBG, CCG,CCNC & SYP

Q.15.

One EWSD exchange is working with two BAPs and two IOCs. Because of increase in the BHCA two CAPs are being added in the exchange. How many additional PIA modules are required ? Two (One for each BCMY) (2)

Q.16.

One EWSD exchange is working with 120 LTGs. How many IOP:MBs will you find in the IOP0 and IOP1 shelves ? Eight (4+4) This EWSD is expanded to add 120 more LTGs. How many additional IOP:MBs will be required? Two (1+1)

(2) (2) (3)

Q.17.

List out 3 differences in LTG (FN. B) and LTG (FN. C) (i) (ii) (iii)

Lines are connected on LTG (FN. B), Trunks are connected on LTG (FN. C). Load parameter for LTG (FN. B) is 12 or 52 whereas it is 13 for LTG (FN. C). CRPs are used for LTG (FN. B) whereas for LTG (FN. C) CRM or RM:CTC are used . (5)

Q.18.

Which commands (parameter names not required) will be used to know (i) the operational status of : DLU system STAT DLU DLU equipment STAT DLUEQ DLU modules STAT DLUMOD DLU subscribers line circuits STAT DLUPORT (ii) the LTGs to which the DLU is connected DISP DLU (a) (i) (ii) (iii) (iv) (b) (c)

Q.19.

Name the modules of LTGM . Also indicate which functional units are integrated in them. (6) DIU120A Four DIU30 and DCC or DIU LDIM Two DIU: LDIB and DCC GPL PU, MU, SIB, SMX, MCH or GPLS which contains modules of GPL and SILC GSMYAA Contains GS, LIU, GCG, TOG and 16 CRPC Circuits or GSMYCC Contains GS, LIU, GCG, TOG and 16 CRMR2 Circuits or GSMYDC Contains GS, LIU, GCG, TOG and 8 CRMR2 plus 4 RM:CTC Circuits Optionally fourth module (LTU:S) can be accommodated e.g. PHMA or COUC or ATE:N or DEC120 or MDTOG or MCT How many LTGN can be accommodated in F:LTGN (A) Sixteen How many STM1 interfaces can be accommodated in frame F:STMI Two ( 1) (1) (5)

Q.20.

An exchange is equipped with 250 LTGs. Calculate the following :

(a) (b) (c) (d) (e) Q.21.

Number of TSGs Number of SSGs Number of MBGs Number of MBU:LTGs Number of MBU:SGCs

= = = = =

4x2 2x2 2x2 4x2 2x2

What does COC stand for? What does it imply ? (3) Cross Office Check. After the path is through connected at the SN, the LIU of the calling LTG performs a cross-office check (COC) through the SN-halves. The purpose of the COC is to detect errors. In the COC, a test bit pattern from the LIU part of the LTG of the calling subscriber is sent to the LTG of the called subscriber, where it is looped back and returned to the sending LIU part. The LTG at this end compares the transmitted and received bit patterns and, if they match, confirm that the existing connection will be used for transferring information. Write down the equivalent modules for the old SN version : TSMB = Two TSM plus Two LIL SSM8B= Two SSM 8/15 plus Two LIS SSM16B=Eight SSM16/16 LISB = Two LIS (10)

Q.22.

SGCB = SGC plus LIM