Sei sulla pagina 1di 29

FloBoss 103 Flow Manager

TM

The Cost-Effective Alternative to Chart Recorders.

Flow Computer Division


ESC to Exit
FB103 1 of 29 11-02-04

Say Goodbye to Chart Recorders...

Manually gathering and integrating charts is time consuming, labor intensive, and costly. Low accuracy, off-chart readings, inking problems, and malfunctions mean more lost and unaccounted gas. Chart recorders provide few capabilities beyond pressure and temperature measurement.

ESC to Exit

Flow Computer Division

FB103 2 of 29 11-02-04

And to Complicated EFM Installations...

Typical EFM installations are a maze of solar panels, battery boxes, radios, antennas, and wiring making installation difficult and costly. Engineering these installations can be time consuming, and the end result may not meet performance expectations.

ESC to Exit

Flow Computer Division

FB103 3 of 29 11-02-04

And Hello to the FloBoss 103

The FloBoss 103 provides fast, convenient, and inexpensive electronic retrieval of gas flow data locally or remotely. The FloBoss 103 delivers higher accuracy and eliminates chart problems. The result, less lost and unaccounted gas. The FloBoss 103 integrates batteries, communication cards, and sensor into a single, easyto-install unit.
ESC to Exit

Flow Computer Division

FB103 4 of 29 11-02-04

The FloBoss 103 Mission

To fulfill the need for a high-performance, compact single-run flow computer that is the ideal replacement for the traditional paper chart recorders used in natural gas flow measurement. To provide API Chapter 21.1 compliant flow measurement in a unit that is self contained -i.e., batteries and communications are built-in. All you need to add is an RTD and a 2- or 5Watt solar panel for full functionality.

ESC to Exit

Flow Computer Division

FB103 5 of 29 11-02-04

Functional Overview

The FloBoss 103 provides these outstanding functional features:


AGA Flow Calculations Historical Databases Event and Alarm Logs Data Security Embedded Communications Spontaneous Report-by-Exception (SRBX) Host Communication Pass-Through Communication Closed-loop PID Control Logic and Sequencing Control ROCLINK 800 Configuration Interface
ESC to Exit

Flow Computer Division

FB103 6 of 29 11-02-04

AGA Flow Calculations

Gas flow is calculated for both volume and energy in accordance with the 1992 AGA Report No. 3. AGA 8 compressibility calculations use Detail, Gross I, or Gross II methods. Meter setup is made quick and easy using fill-in-theblanks data entry.

ESC to Exit

Flow Computer Division

FB103 7 of 29 11-02-04

Historical Databases

The FloBoss 103 maintains API Chapter 21.1 compliant historical archives for measured and calculated values, and events/alarms. Up to 35 standard history points can be archived on an hourly and daily basis for up to 35 days. An extended history database supports data logging at intervals from 1 to 60 minutes, giving operators the flexibility to meet the needs of advanced applications.
ESC to Exit
FB103 8 of 29 11-02-04

Flow Computer Division

Event and Alarm Logs

The Event Log records the last 240 parameter changes and power on/off cycles. The Alarm Log records the last 240 occurrences of alarms (set or clear).

The logs can be viewed, saved to a disk file, or printed by using ROCLINK 800 software.

ESC to Exit

Flow Computer Division

FB103 9 of 29 11-02-04

Data Security

A maximum of 16 log-on identifiers (IDs) for operators can be stored. The log-on ID entered into ROCLINK 800 must match one of the stored IDs for the unit to communicate. Both the operator interface and host can have the same security. Security levels may be determined by user and access level.

ESC to Exit

Flow Computer Division

FB103 10 of 29 11-02-04

Embedded Communications

The FloBoss 103 offers a built-in EIA-485 port and an optional EIA-232 port or dialup modem port for host communications. An optional spread-spectrum radio interface supports either FreeWave M-Series or MaxStream 9X Stream spread-spectrum radios that fit entirely within the FloBoss 103 enclosure.

ESC to Exit

Flow Computer Division

FB103 11 of 29 11-02-04

SRBX Communication

Spontaneous Report-By -Exception (SRBX) communication allows the FloBoss 103 to automatically report any alarm to a host computer. SRBX can be performed over dial-up modem or serial line to a host that is set up for receiving field-initiated calls.
ESC to Exit

Flow Computer Division

FB103 12 of 29 11-02-04

Pass-Through Communications

Pass-through gives the FloBoss 103 the capability to pass information between a host and devices connected to the FloBoss 103 that use ROC or Modbus protocol. Pass-through reduces the cost of communication when several devices are geographically grouped. Pass-through is available for use with RS485, RS232, or dial-up modem connections.
ESC to Exit
FB103 13 of 29 11-02-04

Flow Computer Division

PID Loop Control

PID (Proportional, Integral, and Derivative) closed-loop control provides stable operation of a feedback control loop that employs a regulating device, such as a control valve. The PID loop has its own user-defined input, output, and override capability.
ESC to Exit
FB103 14 of 29 11-02-04

Flow Computer Division

Logic and Sequencing Control

Analog and discrete sequencing control is implemented through a Function Sequence Table (FST). The FST defines the actions to be performed by the FloBoss 103 through a series of Functions. The FST is developed using ROCLINK 800 software.
ESC to Exit
FB103 15 of 29 11-02-04

Flow Computer Division

ROCLINK 800 Configuration Interface

ROCLINK 800 is the easyto-use software for configuration and downloading data. Compatible with most other FloBoss and ROC products for convenience in mixedproduct installations. On-line Help screens get first-time users up and running quickly.

ESC to Exit

Flow Computer Division

FB103 16 of 29 11-02-04

FloBoss 103 Technical Features


High-Accuracy Dual-Variable Sensor 32-bit Processor

Built-in Battery Pack


Communications Cards / Radio Termination / I/O Board Rugged CSA-Approved Design Local Operator Display

Solar Panel and Mast


ESC to Exit

Flow Computer Division

FB103 17 of 29 11-02-04

FloBoss 103 Component Overview


LCD Battery Pack & Charger

Processor Memory Backup

Termination Board

Modem / RS232

Backplane

Dual-Variable Sensor
FB103 18 of 29 11-02-04

ESC to Exit

Flow Computer Division

High-Accuracy Dual-Variable Sensor

Dual-variable sensor uses Rosemount capacitance cell technology.

Measures static and differential pressure.


Accuracy is +0.1% standard or +0.075% optional. High stability design means less calibration. Exclusive co-planer flange for easy installation.
ESC to Exit
FB103 19 of 29 11-02-04

Flow Computer Division

32-Bit Processor / Backplane

High performance 32-bit processor is designed for low-power applications.

Memory consists of:


128 Kb flash boot ROM 2 Mb flash program ROM

Backplane

512 Kb of data RAM

All boards plug into a backplane making removal and replacement quick and easy.

Processor

ESC to Exit

Flow Computer Division

FB103 20 of 29 11-02-04

Built-In Battery Pack

Rechargeable lead acid batteries provide more than 15 days of autonomy, at one modem poll per day, without recharging. A 2- or 5-Watt solar panel will operate the FloBoss 103 indefinitely in a typical installation. Real-time clock and static RAM are backed up with a 3.6v lithium battery.
ESC to Exit

Flow Computer Division

FB103 21 of 29 11-02-04

Communications Cards / Radio

Local Operator Interface port uses RS-232C format. Standard RS-485 port is configurable for 600 to 19.2 K baud. Communication to a Host is supported by an optional RS232 or modem card, or built-in spread spectrum radio. Available protocols include ROC or Modbus Slave (ASCII or RTU).
ESC to Exit
FB103 22 of 29 11-02-04

Flow Computer Division

Termination / I/O Board

2 or 3-wire RTD element input is built-in. Diagnostic inputs for internal voltage, battery voltage, and enclosure/battery temperature are built-in.

Optional I/O board provides 6 channels of I/O that are switchselectable in combinations of analog and discrete inputs and outputs, and pulse inputs.

ESC to Exit

Flow Computer Division

FB103 23 of 29 11-02-04

Rugged, CSA-Approved Design

The base FloBoss 103 is approved for use in Class I, Division 1 and Division 2 areas.

The Solar Panel and Mast Assembly are approved for use in Class I, Division 2 areas only.
Housing and end caps are die-cast aluminum alloy with iridite plating and paint. Field wiring routes through sidemounted conduit ports and connects to the termination board located behind a removeable endcap.
ESC to Exit
FB103 24 of 29 11-02-04

Flow Computer Division

Local Operator Display (Optional)

Flow information is scrolled on a two-line liquid crystal display (LCD) when activated by the user. Top line displays values (8 numerals) and bottom line displays descriptions (5 alpha-numeric characters). Information displayed is configured by the user according to their needs.
ESC to Exit
FB103 25 of 29 11-02-04

Flow Computer Division

Solar Panel and Mast (Optional)

Optional solar panel and mast attach to the top of the FloBoss 103.

Solar panel can be positioned 360 degrees in azimuth and 90 degrees in elevation for optimal sun coverage. The 2-Watt panel measures only 4 by 6.25 inches and the 5-Watt only 8.75 by 9 inches.

ESC to Exit

Flow Computer Division

FB103 26 of 29 11-02-04

Go With the Leader in Process Control...

Process Management Appliance Solutions

Network Power Climate Technologies

Emerson Power & Water Solutions

Motor Technologies Professional Tools Storage Solutions

Industrial Automation

ESC to Exit

Flow Computer Division

FB103 27 of 29 11-02-04

...And the Leader in Products and Service

Emerson Process Management offers the industry's broadest array of process-automation products.

1st/2nd/3rd PLACE FINISHES

Emerson
Rockwell Honeywell Invensys Siemens ABB

39
17 16 14 15 5

So it's not surprising that, in an independent survey conducted by Control magazine, users have once again ranked our products first in more categories than any other supplier.

#1 IN SERVICES
Rated Very Good or better in 33 Service Categories More than twice our closest competitor

ESC to Exit

Flow Computer Division

FB103 28 of 29 11-02-04

Go with Emerson Process Management!

For detailed information on the FloBoss 103 and other great Flow Computer Division products, contact your Emerson Process Management Representative or call: 1-800-807-0730 (U.S. & Canada only) 1-641-754-3449 (Worldwide) You can also visit us on the World Wide Web at: www.EmersonProcess.com/flow
ESC to Exit

Flow Computer Division

FB103 29 of 29 11-02-04

Potrebbero piacerti anche