Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Copper Cables
Max DC Resistance at 2.86 Ohm/100 ft 2.86 Ohm/100 ft 2.86 Ohm/100 ft 2.86 Ohm/100 ft 20C (9.38 Ohm/100 m) (9.38 Ohm/100 m) (9.38 Ohm/100 m) (9.38 Ohm/100 m) Resistance unbalance 3% 3% 5% 5%
Capacitance unbalance 100.58 pF/100 ft pair-to-ground at 1 kHz (330 pF/100 m) Characteristic impedance at 1-16 MHz Min structural return Loss (SRL) at 10 MHz at 16 MHz Max attenuation at 20C at 772 kHz at 1 MHz at 4 MHz at 8 MHz at 10 MHz at 16 MHz Min NEXT loss at 772 kHz at 1 MHz at 4 MHz at 8 MHz at 10 MHz at 16 MHz Min relative velocity of propagation at 10 MHz 85115 Ohm
100.58 pF/100 ft 100.58 pF/100 ft 100.58 pF/100 ft (330 pF/100 m) (330 pF/100 m) (330 pF/100 m) 85115 Ohm 85115 Ohm 85115 Ohm
2.2 dB/100 m 2.6 dB/100 m 5.6 dB/100 m 8.5 dB/100 m 9.7 dB/100 m 13.1 dB/100 m
Specifications
Meets EIA/TIA 568-B for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 10 pairs, category 3, solid Cable is used for indoor installation Conductive material: soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.29 (7.5 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 3.93 (100 mm) Minimum bend radius: 6 outer cable diameters Conductor elongation: 14% minimum Operating temperature: +14F to +122F (10C to +50C) Weight per 1000 ft: 43 lbs (19.5 kg) Standard package: 3280 ft (1000 m) UTP10-C3-SOLID-INDOOR Unshielded twisted pair cable (UTP), 10 pairs, category 3, solid, indoor
Description Materials:
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair
Technical characteristics:
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
97
Specifications
Meets EIA/TIA 568-B for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 25 pairs, category 3, solid Cable is used for indoor installation Conductive material: soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.43 (11 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 3.93 (100 mm) Minimum bend radius: 6 outer cable diameters Conductor elongation: 14% minimum Operating temperature: +14F to +122F (10C to +50C) Weight per 1000 ft: 102.8 lbs (46.6 kg) Standard package: 3280 ft (1000 m) UTP25-C3-SOLID-INDOOR Unshielded twisted pair cable (UTP), 25 pairs, category 3, solid, indoor
Description Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Protective skin Solid twisted pair Polymer tape
Ordering information
Specifications
Meets EIA/TIA 568-B for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 50 pairs, category 3, solid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.59 (15 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Operating temperature: +14F to +122F (10C to +50C) Weight per 1000 ft: 196.9 lbs (89.3 kg) Standard package: 1640 ft (500 m) UTP50-C3-SOLID-INDOOR Unshielded twisted pair cable (UTP), 50 pairs, category 3, solid, indoor
Description Materials:
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair
Technical characteristics
Ordering information
Contact a Hyperline representative in your region for additional technical details and specifications.
www.hyperline.com
1-888-HYPER4U
98
Copper Cables
Specifications
Meets EIA/TIA 568-B for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 100 pairs, category 3, solid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.78 (20 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Operating temperature: +14F to +122F (10C to +50C) Weight per 1000 ft: 372.9 lbs (169.2 kg) Standard package: 1640 ft (500 m) UTP100-C3-SOLID-INDOOR Unshielded twisted pair cable (UTP), 100 pairs, category 3, solid, indoor
Schematic symbols: Jacket Rip-cord Protective skin Solid twisted pair Polymer tape
Description Materials:
Technical characteristics
Ordering information
@
FTP10-C3-SOLID-INDOOR
Contact a Hyperline representative in your region to get additional technical characteristics of cable
Specifications
Meets EIA/TIA 568-B for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 10 pairs, category 3, solid Shield aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.31 (8 mm) Jacket thickness: 0.027 (0.7 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Installation temperature: +22F to +122F (5C to +50C) Operating temperature: 4F to +122F (20C to +50C) Weight per 1000 ft: 47 lbs (21.3 kg) Standard package: 3280 ft (1000 m) FTP10-C3-SOLID-INDOOR Shielded twisted pair cable (FTP), 10 pairs, category 3, solid, indoor
Description
Materials:
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
99
Specifications
Meets EIA/TIA 568-B.2 for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 25 pairs, category 3, solid Shield aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.45 (11.5 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Installation temperature: +23F to +122F (5C to +50C) Operating temperature: 4F to +122F (20C to +50C) Weight per 1000 ft: 108.9 lbs (49.4 kg) Standard package: 3280 ft (1000 m) FTP25-C3-SOLID-INDOOR Shielded twisted pair cable (FTP), 25 pairs, category 3, solid, indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Solid twisted pair Polymer tape
Ordering information
Specifications
Meets EIA/TIA 568-B.2 for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 50 pairs, category 3, solid Shield aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.59 (15 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Installation temperature: +23F to +122F (5C to +50C) Operating temperature: 4F to +122F (20C to +50C) Weight per 1000 ft: 205 lbs (93 kg) Standard package: 1640 ft (500 m) FTP50-C3-SOLID-INDOOR Shielded twisted pair cable (FTP), 50 pairs, category 3, solid, indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair
Ordering information
www.hyperline.com
1-888-HYPER4U
100
Copper Cables
Specifications
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair
Meets EIA/TIA 568-B.2 for category 3 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 100 pairs, category 3, solid Shield aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.86 (22 mm) Jacket thickness: 0.059 (1.5 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Installation temperature: +23F to +122F (5C to +50C) Operating temperature: 4F to +122F (20C to +50C) Weight per 1000 ft: 383 lbs (173.7 kg) Standard package: 1640 ft (500 m) FTP100-C3-SOLID-INDOOR Shielded twisted pair cable (FTP), 100 pairs, category 3, solid, indoor
Description
Materials:
Technical characteristics
Ordering information
Specifications
Meets EIA/TIA 568-B for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 10 pairs, category 3, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.33 (8.5 mm) Jacket thickness: 0.051 (1.3 mm) Maximum strand pitch: 3.93 (100 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +14F to +122F (10C to +50C) Operating temperature: 40F to +122F (40C to +50C) Weight per 1000 ft: 39 lbs (17.7 kg) Standard package: 3280 ft (1000 m) UTP10-C3-SOLID-OUTDOOR Unshielded twisted pair cable (UTP), 10 pairs, category 3, solid, outdoor
Description Materials:
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
101
Specifications
Meets EIA/TIA 568-B for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 25 pairs, category 3, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.47 (12 mm) Jacket thickness: 0.051 (1.3 mm) Maximum strand pitch: 3.93 (100 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +14F to +122F (10C to +50C) Operating temperature: 40F to +122F (40C to +50C) Weight per 1000 ft: 94.14 lbs (42.7 kg) Standard package: 3280 ft (1000 m) UTP25-C3-SOLID-OUTDOOR Unshielded twisted pair cable (UTP), 25 pairs, category 3, solid, outdoor
Description Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair
Ordering information
Specifications
Specifications Meets EIA/TIA 568-B for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 50 pairs, category 3, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.62 (16 mm) Jacket thickness: 0.059 (1.5 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +14F to +122F (10C to +50C) Operating temperature: 40F to +122F (40C to +50C) Weight per 1000 ft: 183.4 lbs (83.2 kg) Standard package: 1640 ft (500 m) UTP50-C3-SOLID-OUTDOOR Unshielded twisted pair cable (UTP), 50 pairs, category 3, solid, outdoor
Description Materials:
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
102
Copper Cables
Specifications
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair
Meets EIA/TIA 568-B for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Unshielded Copper cable, 100 pairs, category 3, solid, twisted pairs are divided into 4 cable bundles of 25 pairs each Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.82 (21 mm) Jacket thickness: 0.059 (1.5 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius:10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +14F to +122F (10C to +50C) Operating temperature: 40F to +122F (40C to +50C) Weight per 1000 ft: 332.6 lbs (150.9 kg) Standard package: 1640 ft (500 m) UTP100-C3-SOLID-OUTDOOR Unshielded twisted pair cable (UTP), 100 pairs, category 3, solid, outdoor
Description
Materials:
Technical characteristics
Ordering information
Specifications
Meets EIA/TIA 568-B.2 for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 10 pairs, category 3, solid Shield aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.31 (8 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Operating temperature: 40F to +158F (40C to +70C) Weight per 1000 ft: 43 lbs (19.5 kg) Standard package: 3280 ft (1000 m) FTP10-C3-SOLID-OUTDOOR Shielded twisted pair cable (FTP), 10 pairs, category 3, solid, outdoor
Description
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
103
Specifications
Meets EIA/TIA 568-B.2 for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 25 pairs, category 3, solid Shield aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.47 (12 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Operating temperature: 40F to +158F (40C to +70C) Weight per 1000 ft: 100.1 lbs (45.4 kg) Standard package: 3280 ft (1000 m) FTP25-C3-SOLID-OUTDOOR Shielded twisted pair cable (FTP), 25 pairs, category 3, solid, outdoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Solid twisted pair Polymer tape
Ordering information
Specifications
Meets EIA/TIA 568-B.2 for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 50 pairs, category 3, solid Shield aluminum foil, twisted pairs are divided into 4 bundles; 2 of 12 pairs and 2 of 13 pairs Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.59 (15 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Operating temperature: 40F to +158F (40C to +70C) Weight per 1000 ft: 191.5 lbs (86.9 kg) Standard package: 1640 ft (500 m) FTP50-C3-SOLID-OUTDOOR Shielded twisted pair cable (FTP), 50 pairs, category 3, solid, outdoor
Description
Materials:
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
104
Copper Cables
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair
Specifications
Meets EIA/TIA 568-B.2 for category 3 requirements Fire protection CMX The cable meets IEC 60332-1 fire safety standard Shielded Copper cable, 100 pairs, category 3, solid Shield aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.31 (8 mm) Jacket thickness: 0.039 (1 mm) Maximum strand pitch: 5.9 (150 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Installation temperature: +10F to +122F (10C to +50C) Operating temperature: 40F to +158F (40C to +70C) Weight per 1000 ft: 342.7 lbs (155.4 kg) Standard package: 1640 ft (500 m) FTP100-C3-SOLID-OUTDOOR Shielded twisted pair cable (FTP), 100 pairs, category 3, solid, outdoor
Description
Materials:
Technical characteristics
Ordering information
Description Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair Messenger
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
105
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair Messenger
Ordering information
Description
Materials:
Technical characteristics
Ordering information
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair Steel wire
www.hyperline.com
1-888-HYPER4U
106
Copper Cables
Description
Materials:
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Polymer tape Solid twisted pair Steel wire
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
107
Specifications
Meets EIA/TIA 568-A requirements Fire protection CMX The cable meets UL 444/UL 1581 fire safety standard Unshielded Copper cable, 2 pairs, category 5, solid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC (polyvinyl chloride) Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.0360.008 (0.920.02 mm) Outer cable diameter: 0.180.008 (4.60.02 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +23F to +104F (5C to +40C) Operating temperature: 4F to +167F (20C to +75C) Weight per 1000 ft: 12.1 lbs (5.5 kg) Standard package: 1640 ft (500 m) UTP2-C5e-SOLID-GY Unshielded twisted pair cable (UTP), 2 pairs, category 5, solid, indoor, grey
Description Materials:
Technical characteristics
Ordering information
Specifications
Meets EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 444/UL 1581 fire safety standard Unshielded Copper cable, 2 pairs, category 5, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0360.008 (0.920.02 mm) Outer cable diameter: 0.160.008 (4.30.02 mm) Jacket thickness: 0.025 (0.65 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 11.9 lbs (5.4 kg) Standard package: 1640 ft (500 m) UTP2-C5e-SOLID-OUTDOOR-40 Unshielded twisted pair cable (UTP), 2 pairs, category 5, solid, outdoor
Description Materials:
Technical characteristics
Ordering information
Contact a Hyperline representative in your region to get additional technical characteristics of cable
www.hyperline.com
1-888-HYPER4U
108
Copper Cables
Specifications
Meets EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 444/UL1581 fire safety standard Shielded Copper cable, 2 pairs, category 5, solid Shield aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0360.008 (0.920.02 mm) Outer cable diameter: 0.20.008 (5.10.02 mm) Jacket thickness: 0.025 (0.65 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 17.1 lbs (7.7 kg) Standard package: 1640 ft (500 m) FTP2-C5e-SOLID-OUTDOOR-40 Shielded twisted pair cable (FTP), 2 pairs, category 5, solid, outdoor
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Solid twisted pair
Description
Materials:
Technical characteristics
Ordering information
Unshielded Twisted Pair Cable (UTP), 2 pairs, Solid, Outdoor, with Messenger
UTP2-C5E-SOLID-SW-OUTDOOR-40
Specifications
Meets EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 444/UL 1581 fire safety standard Unshielded Copper cable, 2 pairs, category 5, solid, with steel wire Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Messenger Conductor diameter: 0.54 mm (AWG) Insulated conductor diameter: 0.0360.008 (0.920.02 mm) Outer cable diameter: 0.170.008 (4.30.02 mm) Jacket thickness: 0.025 (0.65 mm) Messenger diameter: 0.1 (2.6 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 22.8 lbs (10.4 kg) Standard package: 1640 ft (500 m) Unshielded twisted pair cable (UTP), 2 pairs, category 5, solid, outdoor, with messenger
Schematic symbols: Jacket Rip-cord Protective skin Solid twisted pair Messenger
Description Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
109
Shielded Twisted Pair Cable (FTP), 2 pairs, Solid, Outdoor, with Messenger
FTP2-C5E-SOLID-SW-OUTDOOR-40
Specifications
Meets EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 444/UL 1581 fire safety standard Shielded Copper cable, 2 pairs, category 5, solid, with steel wire Shield aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Messenger Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0350.008 (0.90.02 mm) Outer cable diameter: 0.20.008 (5.10.02 mm) Jacket thickness: 0.025 (0.65 mm) Messenger diameter: 0.1 (2.6 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 30.4 lbs (13.8 kg) Standard package: 1640 ft (500 m) FTP2-C5E-SOLID-SW-OUTDOOR-40 Shielded twisted pair cable (FTP), 2 pairs, category 5, solid, outdoor, with messenger
Description
Materials:
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Solid twisted pair Messenger
Technical characteristics
Ordering information
Multi-pair cables are mainly intended for main cabling. This cable is specified up to 100 MHz. Category 5 UTP multi-pair cables meet ANSI/TIA/EIA 568A, ISO/IEC 11801, and EN 50173 requirements for category 5. The cable structure provides high crosstalk attenuation. The conductor insulation is made of PE. Indoor cable has a light grey PVC jacket, outdoor cable has a black PVC jacket. Each bunch of cable is separated by wrapped tape. Temperature plays a great role in cabling technology. Low temperature influence results in a loss of cable flexibility. The cable becomes fragile, and it becomes difficult to work with it. Conversely, high temperature destroys the plastic used in cable manufacturing. Therefore, it is very important to use cable with characteristics appropriate for the operating environment.
Capacitance unbalance at 1 kHz Longitudinal conversion 43 dB loss at 64 kHz Max voltage rating 300 V Dielectric strength of 1000 V RMS insulation Nominal velocity of 68% propagation Max propagation delay at 1 MHz 1.74 ns/ft (5.7 ns/m) at 10 MHz 1.64 ns/ft (5.4 ns/m) at 100 MHz 1.61 ns/ft (5.3 ns/m) Propagation delay skew 10.61 ns/100 ft at 1100 MHz (35 ns/100m) Min insulation 8.05 GOhm/mile resistance (5 GOhm/km)
www.hyperline.com
1-888-HYPER4U
110
Copper Cables
Schematic symbols: Jacket Protective skin Solid twisted pair Central power member
Meets ANSI/EIA/TIA 568-A-5 and ISO/IEC 11801 for category 5 requirements The cable meets UL 1581 VW-1 and IEC 60332.1 fire safety standard The cable contains 8 unshielded twisted pairs, jacketed with PVC compound The cable is used for indoor installation. Conductive material: wire made of soft annealed copper Conductor insulation: PO The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.28 (7.2 mm) Jacket thickness: 0.028 (0.7 mm) Bend radius (installation): 10 outer cable diameters Bend radius (operation): 6 outer cable diameters Installation temperature: +23F to +122F (5C to +50C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 40.3 lbs (18.3 kg) Standard package: 3280 ft (1000 m) UTP8M-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 8 pairs, category 5, solid, indoor
Technical characteristics
Ordering information
Schematic symbols: Jacket Rip-cord Protective skin Solid twisted pair Central power member
Specifications
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard The cable contains 10 unshielded twisted pairs, jacketed with PVC compound The cable is used for indoor installation Conductive material: wire made of soft annealed copper Conductor insulation: PO The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.3 (7.6 mm) Jacket thickness: 0.031 (0.8 mm) Bend radius (installation): 10 outer cable diameters Bend radius (operation): 6 outer cable diameters Installation temperature: +23F to +122F (5C to +50C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 48.4 lbs (21.9 kg) Standard package: 3280 ft (1000 m) UTP10M-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 10 pairs, category 5, solid, indoor
Description Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
111
Specifications Description
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 for category 5 requirements The cable meets UL 1581 VW-1 fire safety standard The multi-core cable contains 3 unshielded non-jacketed cables, each containing 4 twisted pairs with identity tapes, cabled together and wrapped with plastic tape. The cable is used for indoor installation Conductive material: wire made of soft annealed copper Conductor insulation: PO The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Outer cable diameter: 0.39 (10 mm) Jacket thickness: 0.031 (0.8 mm) Bend radius (installation): 20 outer cable diameters Bend radius (operation): 10 outer cable diameters Installation temperature: +32F to +122F (0C to +50C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 62.5 lbs (28.3 kg) Standard package: 3280 ft (1000 m) UTP12-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 12 pairs, category 5, solid, indoor
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair Marking tape
Ordering information
Specifications Description
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 for category 5 requirements The cable meets UL 1581 VW-1 fire safety standard The multi-core cable contains 4 unshielded non-jacketed cables, each containing 4 twisted pairs with identity tapes, cabled together and wrapped with plastic tape The cable is used for indoor installation. Conductive material: wire made of soft annealed copper Conductor insulation: PO The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Outer cable diameter: 0.47 (12 mm) Jacket thickness: 0.031 (0.8 mm) Bend radius (installation): 20 outer cable diameters Bend radius (operation): 10 outer cable diameters Installation temperature: +32F to +122F (0C to +50C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 79.3 lbs (36 kg) Standard package: 3280 ft (1000 m) UTP16-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 16 pairs, category 5, solid, indoor
Materials:
Schematic symbols: Jacket Rip-cord Protective skin Polymer tape Solid twisted pair Marking tape
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
112
Copper Cables
Specifications
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded multi-pair Copper cable, 24 pairs, category 5, solid, cable consists of 6 unshielded (UTP) bunches ( 0.16 (4 mm)) of 4 twisted pairs each Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.51 (13 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Pulling strength: 500 N Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 114.2 lbs (51.8 kg) Standard package: 3280 ft (1000 m) UTP24-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 24 pairs, category 5, solid, indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Polymer tape Protective skin Solid twisted pair Marking tape Central power member
UTP48-C5-SOLID-INDOOR
Ordering information
Specifications
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Unshielded multi-pair Copper cable, 48 pairs, category 5, solid, cable consists of 12 unshielded (UTP) bunches (0.16 (4 mm)) of 4 twisted pairs each Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 3 (17.6 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Pulling strength: 500 N Breaking strength: 600 N Installation temperature: +23F to +104F (5C to +40C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 201.6 lbs (91.4 kg) Standard package: 1640 ft (500 m) UTP48-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 48 pairs, category 5, solid, indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Polymer tape Protective skin Solid twisted pair Marking tape
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
113
Specifications
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 requirements Fire protection CM The cable meets IEC 60332-1 fire safety standard Unshielded multi-pair Copper cable, 100 pairs, category 5, solid, cable consists of 25 unshielded (UTP) numbered bunches (0.16 (4 mm)) of 4 twisted pairseach Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 1 (25.6 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Pulling strength: 500 N Breaking strength: 600 N Installation temperature: +23F to +104F (5C to +40C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 397.8 lbs (180.4 kg) Standard package: 1640 ft (500 m) UTP100-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 100 pairs, category 5, solid, indoor
Description
Materials:
Technical characteristics
Ordering information
Schematic symbols: Jacket Rip-cord Polymer tape Protective skin Solid twisted pair Marking tape Central power member
Unshielded Twisted Pair Cable (UTP), 25 (50, 100) pairs, Solid, Indoor
UTPYYM-C5-SOLID-INDOOR
Specifications
Meets ANSI/EIA/TIA 568-A requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded multi-pair Copper cable, 25 (50, 100) pairs, category 5, solid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.490.9 (12.523 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 6 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Pulling strength: 500 N Breaking strength: 600 N Installation temperature: +23F to +104F (5C to +40C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 107.5369.6 lbs (48.8167.6 kg) Standard package: 16403280 ft (5001000 m) UTPYYM-C5-SOLID-INDOOR (YYquantity of pairs: 25, 50, 100 pairs) Unshielded twisted pair cable (UTP), category 5, solid, indoor
Description Materials:
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
114
Copper Cables
Shielded Twisted Pair Cable (FTP), 25 (50, 100) pairs, Solid, Indoor
FTPYYM-C5-SOLID-INDOOR
Specifications
Meets ANSI/EIA/TIA 568-A requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded multi-pair Copper cable, 25 (50, 100) pairs, category 5, solid Shield: aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.591.18 (1530 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Pulling strength: 500 N Breaking strength: 600 N Installation temperature: +23F to +104F (5 C to +40C) Operating temperature: +23F to +140F (5C to +60C) Weight per 1000 ft: 190.2467 lbs (72.5211.8 kg) Standard package: 16403280 ft (5001000 m) FTPYYM-C5-SOLID-INDOOR (YY- quantity of pairs: 25, 50, 100 pairs) Shielded twisted pair cable (FTP), 25 (50, 100) pairs, category 5, solid, indoor
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Solid twisted pair
Description
Materials:
Technical characteristics
Ordering information
Specifications
Meets EIA/TIA 568-A requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 25 pairs, category 5, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.036 (0.92 mm) Outer cable diameter: 0.48 (12.4 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +14F to +104F (10C to +40C) Operating temperature: 40F to +158F (40C to +70C) Weight per 1000 ft: 114.2 lbs (51.8 kg) Standard package: 3280 ft (1000 m) UTP25-C5-SOLID-OUTDOOR Unshielded twisted pair cable (UTP), 25 pairs, category 5, solid, outdoor
Description
Schematic symbols: Jacket Rip-cord Protective skin Solid twisted pair Central power member
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
115
Specifications
Meets EIA/TIA 568-A requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 50 pairs, category 5, solid, twisted pairs are divided in 2 bunches of 25 pairs each Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) The outer cable diameter: 0.49x0.89 (12.6x22.8 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +14F to +104F (10C to +40C) Operating temperature: 40F to +158F (40C to +70C) Weight per 1000 ft: 228.5 lbs (103.6 kg) Standard package: 1640 ft (500 m) UTP50-C5-SOLID-OUTDOOR Unshielded twisted pair cable (UTP), 50 pairs, category 5, solid, outdoor
Description
Materials:
Technical characteristics
Ordering information
Schematic symbols: Jacket Rip-cord Protective skin Solid twisted pair Central power member
Specifications
Meets EIA/TIA 568-A requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable,100 pairs, category 5, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) The outer cable diameter: 1 (25.6 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 10 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Installation temperature: +14F to +104F (10C to +40C) Operating temperature: 40F to +158F (40C to +70C) Weight per 1000 ft: 383.7 lbs (174 kg) Standard package: 1640 ft (500 m) UTP100-C5-SOLID-OUTDOOR Unshielded twisted pair cable (UTP), 100 pairs, category 5, solid, outdoor
Description Materials:
Technical characteristics
Ordering information
Schematic symbols: Jacket Rip-cord Polymer tape Protective skin Solid twisted pair Marking tape Central power member
www.hyperline.com
1-888-HYPER4U
116
Copper Cables
Shielded Twisted Pair Cable (FTP), 25 (50, 100) pairs, Solid, Outdoor
FTPYY-C5-SOLID-OUTDOOR
Specifications
Meets ANSI/EIA/TIA 568-A requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Shielded multi-pair Copper cable, 25 (50, 100) pairs, category 5, solid Shield: aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.035 (0.9 mm) Outer cable diameter: 0.621.22 (1631 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Installation temperature: +14F to +104F (10C to +40C) Operating temperature: 49F to +140F (45C to +60C) Weight per 1000 ft: 147.8456.9 lbs (67.1207.3 kg) Standard package: 16403280 ft (5001000 m) FTPYY-C5-SOLID-OUTDOOR (YY quantity of pairs: 25, 50, 100 pairs) Shielded twisted pair cable (FTP), 25 (50, 100) pairs, category 5, solid, outdoor
Schematic symbols: Jacket Rip-cord Shield-foil Drain wire Protective skin Solid twisted pair Central power member
Description
Materials:
Technical characteristics
Ordering information
The nearest cable end relative to the receiving terminal is the most serious source of crosstalk. Due to this, the requirements of category 5e cabling focus on NEXT limitation. As frequency increases, both specific attenuation (decreased signal strength in the receiving terminal), and crosstalk attenuation (an increase in crosstalk) rise. Therefore, it is necessary, in order
to prevent even the most insignificant causes of crosstalk, to provide a signal strength that is higher than the crosstalk level. There is also a FEXT limitation. FEXT characterizes which part of signal at the far end reaches the receiving terminal. As for Equal Level FEXT (ELFEXT), it defines crosstalk attenuation at the far end, taking into consideration attenuation in the cabling system.
1-888-HYPER4U
www.hyperline.com
Copper Cables
117
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 1 pair, category 5e, solid, cross Cable is used for interconnection wiring Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: N/A Conductor diameter: 0.019 (0.5 mm) (24 AWG) Insulated conductor diameter: 0.0350.002 (0.880.05 mm) Outer cable diameter: 0.070.008 (1.70.02 mm) Standard package: 1640 ft (500 m) UTP1-C5e-SOLID-CROSS Unshielded twisted pair cable (UTP), 1 pair, category 5e, solid, cross, indoor
Description Materials:
Technical characteristics
Ordering information
Description Materials:
Technical characteristics
Ordering information
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 2 pairs, category 5e, stranded (patch) Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 7x0.008 (0.2 mm) (24 AWG) Insulated conductor diameter: 0.0380.002 (0.970.05 mm) Outer cable diameter: 0.180.008 (4.50.2 mm) Jacket thickness: 0.02 (0.5 mm) Standard package: 1640 ft (500 m) UTP2-C5e-PATCH-GY Unshielded twisted pair cable (UTP), 2 pairs, category 5e, stranded (patch), indoor
Description Materials:
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
118
Copper Cables
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 5e, solid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0350.008 (0.90.2 mm) Outer cable diameter: 0.20.008 (5.10.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Pulling strength: 92 N Breaking strength: 600 N Installation temperature: +23F to +122F (5C to +50C) Operating temperature:4F to +167F (20C to +75C) Weight per 1000 ft: 21.5 lbs (9.8 kg) Standard package: 1000 ft (305 m) UTP4-C5e-SOLID-XX (XX the jacket color: GY grey, WH white, BL blue, RD red, GN green, YL yellow, BK black, OR orange, PK pink) Unshielded twisted pair cable (UTP), 4 pairs category 5e, solid, indoor Note: Also available: UTP4-C5e-SOLID-PLENUM Unshielded Twisted Pair (UTP), 4 pairs, solid, indoor, plenum UTP4-C5e-SOLID-LSZH Unshielded Twisted Pair (UTP), 4 pairs, solid, indoor, LSZH
Description
Materials:
Technical characteristics
Ordering information
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 5e, stranded (patch) Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 7x0.008 (0.2 mm) (24 AWG) Insulated conductor diameter: 0.0380.008 (0.990.2 mm) Outer cable diameter: 0.210.008 (5.50.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Installation temperature: +32F to +122F (0C to +50C) Operating temperature: 4F to +167F (20C to +75C) Weight per 1000 ft: 22.8 lbs (10.4 kg) Standard package: 1000 ft (305 m) UTP4-C5e-PATCH-XX (XX the jacket color: GY grey, WH white, BL blue, RD red, GN green, YL yellow, BK black, OR orange, PK pink) Unshielded twisted pair cable (UTP), 4 pairs, category 5e, stranded (patch), indoor
Description
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
119
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 5e, solid Shield: aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0350.008 (0.90.2 mm) Outer cable diameter: 0.210.008 (5.40.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Pulling strength: 92 N Breaking strength: 400 N Installation temperature: +23F to +122F (5C to +50C) Operating temperature: 4F to +167F (20C to +75C) Weight per 1000 ft: 24.3 lbs (11 kg) Standard package: 1000 ft (305 m) FTP4-C5e-SOLID-GY Shielded twisted pair cable (FTP), 4 pairs, category 5e, solid, indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Shield-foil Drain wire Protective skin Solid twisted pair
Ordering information
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 5e, stranded (patch) Shield: aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm) Conductor diameter: 7x0.008 (0.2 mm) (24 AWG) Insulated conductor diameter: 0.0350.008 (0.90.2 mm) Outer cable diameter: 0.210.008 (5.40.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Operating temperature: 4F to +167F (20C to +75C) Weight per 1000 ft: 21.5 lbs (9.8 kg) Standard package: 1000 ft (305 m) FTP4-C5e-PATCH-XX (XX the jacket color: GY grey, WH white, BL blue, RD red, GN green, YL yellow, BK black, OR orange, PK pink) Shielded twisted pair cable (FTP), 4 pairs, category 5e, stranded (patch), indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Shield-foil Drain wire Protective skin Stranded twisted pair
Ordering information
www.hyperline.com
1-888-HYPER4U
120
Copper Cables
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 5e, solid Shield: aluminum foil and wire braid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm), and braid of 16 tinned Copper wires Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0350.008 (0.90.2 mm) Outer cable diameter: 0.220.008 (5.80.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Operating temperature: 4F to +167F (20C to +75C) Weight per 1000 ft: 32.9 lbs (14.9 kg) Standard package: 1000 ft (305 m) SFTP4-C5e-SOLID-GY Shielded twisted pair cable (SFTP), 4 pairs, category 5e, solid, indoor
Description
Schematic symbols: Jacket Shield-braid Drain wire Shield-foil Solid twisted pair
Materials:
Technical characteristics
Ordering information
Specifications
Schematic symbols: Jacket Shield-braid Drain wire Shield-foil Stranded twisted pair
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 5e, stranded (patch) Shield: aluminum foil and wire braid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm), and braid of 16 tinned Copper wires Conductor diameter: 7x0.008 (0.2 mm) (24 AWG) Insulated conductor diameter: 0.0360.008 (0.930.2 mm) Outer cable diameter: 0.220.008 (5.60.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Drain wire diameter: 0.019 (0.5 mm) Operating temperature: 4F to +167F (20C to +75C) Weight per 1000 ft: 25.5 lbs (11.6 kg) Standard package: 1000 ft (305 m) SFTP4-C5e-PATCH-GY Shielded twisted pair cable (SFTP), 4 pairs, category 5e, stranded (patch), indoor
Description
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
121
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 5e, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0350.008 (0.90.2 mm) Outer cable diameter: 0.20.008 (5.30.2 mm) Jacket thickness: 0.025 (0.65 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Pulling strength: 1500 N Breaking strength: 2000 N Installation temperature: +14F to +122F (10C to +50C) Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 18.8 lbs (8.5 kg) Standard package: 1640 ft (500 m) Rip cord has a breaking strength of 98 N UTP4-C5e-SOLID-OUTDOOR-40 Unshielded twisted pair cable (UTP), 4 pairs, category 5e, solid, outdoor
Description Materials:
Technical characteristics
Ordering information
Unshielded Twisted Pair Cable (UTP), 4 pairs, Solid, Outdoor, with Messenger
UTP4-C5E-SOLID-SW-OUTDOOR-40
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 5e, solid, with steel wire Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Messenger Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.0350.008 (0.90.2 mm) Outer cable diameter: 0.220.008 (5.80.2 mm) Jacket thickness: 0.025 (0.65 mm) Messenger diameter: 0.070.004 (2.00.1 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Installation temperature: +14F to +122F (10C to +50C) Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 55.1 lbs (25 kg) Standard package: 1640 ft (500 m) Rip cord has a breaking strength of 98 N UTP4-C5e-SOLID-SW-OUTDOOR-40 Unsielded twisted pair cable (UTP), 4 pairs, category 5e, solid, outdoor, with messenger
Description Materials:
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
122
Copper Cables
Specifications
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 5e, solid Shield: aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.360.008 (0.930.2 mm) Outer cable diameter: 0.220.008 (5.80.2 mm) Jacket thickness: 0.025 (0.65 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Operating temperature: 40F to +122F (40C to +50C) Weight per 1000 ft: 23.5 lbs (10.7 kg) Standard package: 1640 ft (500 m) FTP4-C5e-SOLID-OUTDOOR-40 Shielded twisted pair cable (FTP), 4 pairs, category 5e, solid, outdoor
Description
Schematic symbols: Jacket Shield-foil Drain wire Protective skin Solid twisted pair
Materials:
Technical characteristics
Ordering information
Shielded Twisted Pair Cable (FTP), 4 pairs, Solid, Outdoor, with Messenger
FTP4-C5E-SOLID-SW-OUTDOOR-40
Specifications
Schematic symbols: Jacket Shield-foil Drain wire Protective skin Solid twisted pair Messenger
Meets ANSI/EIA/TIA 568-B.2 requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 5e, solid, with steel wire Shield: aluminum foil Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm) Messenger Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.360.008 (0.920.2 mm) Outer cable diameter: 0.220.008 (5.80.2 mm) Jacket thickness: 0.025 (0.65 mm) Messenger diameter: 0.070.004 (20.1 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Operating temperature: 40F to +122F (40C to +50C) Weight per 1000 ft: 61.1 lbs (27.7 kg) Standard package: 1640 ft (500 m) FTP4-C5e-SOLID-SW-OUTDOOR-40 Shielded twisted pair cable (FTP), 4 pairs, category 5e, solid, outdoor, with messenger
Description
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
123
66 57 51 48 47 44 44 39 36
63 54 49 45 44 41 41 36 33
20 23 25 25 25 24 24 21.5 20.5
Max capacitance 1.6 pF/m unbalance at 1kHz Longitudinal conver4610*Log(f ) dB sion loss at 130 MHz Max voltage rating 220 V Dielectric strength of 1700 VAC/1 min insulation Nominal velocity of 68% propagation Max propagation delay At 1 MHz 1.74 ns/ft (5.7 ns/m) At 10 MHz 1.64 ns/ft (5.4 ns/m) At 100 MHz 1.61 ns/ft (5.3 ns/m) Propagation delay skew 4.57 ms/100 ft at 1100 MHz (15 ns/100m) Insulation resistance 5 GOhm/km at 500 V
Specifications
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 24 pairs, category 5e, solid. Cable consists of 6 shielded FTP bunches of 4 pairs each Shield: aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.04 (1 mm) Outer cable diameter: 0.78 (20 mm) Jacket thickness: 0.031 (0.8 mm) Minimum bend radius: 10 outer cable diameters Rip cord has a breaking strength of 98 N Conductor elongation: 14% minimum Drain wire diameter: 0.019 (0.5 mm) Pulling strength: 400 N Breaking strength: 600 N Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 221.1 lbs (100.3 kg) Standard package: 3280 ft (1000 m) FTP24-C5e-SOLID-INDOOR Shielded twisted pair cable (FTP), 24 pairs, category 5e, solid, indoor
Description
Materials:
Technical characteristics
Ordering information
Schematic symbols: Jacket Rip-cord Protective skin Shield-foil Drain wire Solid twisted pair Central power member
www.hyperline.com
1-888-HYPER4U
124
Copper Cables
Specifications
Meets ANSI/EIA/TIA 568-A, ISO/IEC 11801 and IEC 61165-6 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 48 pairs, category 5e, solid. Cable consists of 12 shielded FTP bunches of 4 pairs each Shield: aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.04 (1 mm) Outer cable diameter: 1.02 (26 mm) Jacket thickness: 0.047 (1.2 mm) Minimum bend radius: 10 outer cable diameters Rip cord has a breaking strength of 98 N Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 373.6 lbs (169.5 kg) Standard package: 1640 ft (500 m) FTP48-C5e-SOLID-INDOOR Shielded twisted pair cable (FTP), 48 pairs, category 5e, solid, indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Protective skin Shield-foil Drain wire Solid twisted pair Central power member
FTP100-C5E-SOLID-INDOOR
Ordering information
Specifications
Meets ANSI/EIA/TIA 568-A, ISO/IEC 11801 and IEC 61165-6 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 100 pairs, category 5e, solid. Cable consists of 25 shielded FTP bunches of 4 pair each Shield: aluminum foil Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm) Conductor diameter: 0.02 (0.51 mm) (24 AWG) Insulated conductor diameter: 0.04 (1 mm) Outer cable diameter: 1.52 (38.8 mm) Jacket thickness: 0.039 (1 mm) Minimum bend radius: 10 outer cable diameters Rip cord has a breaking strength of 98 N Conductor elongation: 14% minimum Drain wire diameter: 0.019 (0.5 mm) Operating temperature: +32F to +122F (0C to +50C) Weight per 1000 ft: 696.8 lbs (316.1 kg) Standard package: 1640 ft (500 m) FTP100-C5e-SOLID-INDOOR Shielded twisted pair cable (FTP), 100 pairs, category 5e, solid, indoor
Description
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Protective skin Shield-foil Drain wire Solid twisted pair Central power member
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
125
330 pF/100 m
- Category 6 cable is intended for Gigabit Ethernet applications. - Category 6 cable provides performance up to 200 MHz. However, for better quality performance, cables have been tested at higher frequencies (250MHz). - Category 6 cable can be successfully used in all modern applications. ACR of category 6 cable is 45% better than ACR of category 5 and 5e cable at 100MHz.
- The usage of thicker conductors (from 0.45 mm) results in a higher level of attenuation of category 6 cable than category 5 and 5e cable. - Some types of category 6 cable have a plastic spacer between the pairs. This additional separation improves NEXT performance and decreases crosstalk. - The mechanical characteristics of category 6 cable are very close to the mechanical characteristics of category 5 cable. Category 6 cables are compatible with RJ-45 modular plugs.
Unshielded Twisted Pair Cable (UTP), 4 pairs, Solid, Indoor, with Spacer
UTP4-C6-SOLID-GY
Specifications
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 6, solid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: (0.540.01 mm) (24 AWG) Insulated conductor diameter: 0.0380.008 (0.990.2 mm) Outer cable diameter: 0.240.008 (6.20.2 mm) Jacket thickness: 0.015 (0.4 mm) Pulling strength: 130 N Minimum bend radius: 4 outer cable diameters Operating temperature: 4F to +167F (20C to +75C) Weight per 1000 ft: 28.4 lbs (12.9 kg) Standard package: 1000 ft (305 m) UTP4-C6-SOLID-GY Unshielded twisted pair cable (UTP), 4 pairs, category 6, solid, indoor, with spacer Note: Also available : UTP4-C6-SOLID-PLENUM Unshielded Twisted Pair (UTP), 4 pairs, solid, indoor, plenum UTP4-C6-SOLID-LSZH Unshielded Twisted Pair (UTP), 4 pairs, solid, indoor, LSZH
Description Materials:
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
126
Copper Cables
Specifications
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 6, solid 4 separately foil-shielded pairs Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: PVC Shield: every pair is separately shielded with polyester aluminum foil, which covers 100% of twisted pair Conductor diameter: 0.0220.0004 (0.570.01 mm) (23 AWG) Insulated conductor diameter: 0.056 (1.43 mm) Outer cable diameter: 0.3 (7.8 mm) Jacket thickness: 0.027 (0.7 mm) Pulling strength: 130 N maximum Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Drain wire diameter: 0.019 (0.5 mm) Installation temperature is +23F to +122F (5C to +50C) Operating temperature: 4F to +140F (20C to +60C) Weight per 1000 ft: 37 lbs (16.8 kg) Standard package: 1640 ft (500 m) STP4-C6-SOLID-GY Shielded twisted pair cable (STP), 4 pairs, category 6, solid, indoor
Description
Materials:
Technical characteristics
Ordering information
Description
Materials:
Schematic symbols: Jacket Shield-foil Drain wire Protective skin Solid twisted pair
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
127
Specifications
Meets IEC 61156-5, ISO/IEC 11801 and EIA/TIA 568-B.2-1 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, Category 6A, solid 4 separately foil-shielded pairs Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: PVC Shield: every pair is separately shielded with polyester aluminum foil, which covers 100% of twisted pair General shield: An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 0.19 (5 mm), thickness 0.001 (0.025 mm), width 0.78 (20 mm) Conductor diameter: 0.0220.004 (0.570.01mm) (23 AWG) Insulated conductor diameter: 0.056 (1.43 mm) Outer cable diameter: 0.31 (8 mm) Jacket thickness: 0.019 (0.5 mm) Pulling strength: 130 N maximum Minimum bend radius: 5 outer cable diameters Conductor elongation: 14% minimum Rip cord has a breaking strength of 98 N Operating temperature: +14F to +140F (10C to +60C) Weight per 1000 ft: 37 lbs (16.8 kg) Standard package: 1640 ft (500 m) USTP4-C6a-SOLID-INDOOR Shielded twisted pair cable (SFTP), 4 pairs, Category 6A, solid, indoor
Description
Materials:
Technical characteristics
Ordering information
Unshielded Twisted Pair Cable (UTP), 4 pairs, Stranded (patch), Indoor, with Spacer
UTP4-C6-PATCH-GY
Specifications
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 6, stranded (patch) Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film- porous-film structure The cable jacket: PVC Conductor diameter: 7x0.0080.004 (7x0.2 mm0.01 mm) (24 AWG) Insulated conductor diameter: 0.040.008 (1.030.2 mm) Outer cable diameter: 0.20.008 (5.30.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Operating temperature: +23F to +140F (5C to +60C) Weight per 1000 ft: 30.2 lbs (13.7 kg) Standard package: 1000 ft (305 m) UTP4-C6-PATCH-GY Unshielded twisted pair cable (UTP), 4 pairs, category 6, stranded (patch), indoor, with spacer
Description Materials:
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
128
Copper Cables
Unshielded Twisted Pair Cable (UTP), 4 pairs, Stranded (patch), Indoor, without Spacer
UTP4-C6-PATCH-NCR-GY
Specifications
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 6, stranded (patch) Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Conductor diameter: 7x0.0080.004 (7x0.2 mm0.01 mm) (24 AWG) Insulated conductor diameter: 0.040.008 (1.030.2 mm) Outer cable diameter: 0.20.008 (5.30.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Operating temperature: +23F to +140F (5C to +60C) Weight per 1000 ft: 24.9 lbs (11.3 kg) Standard package: 1000 ft (305 m) UTP4-C6-PATCH-NCR-GY Unshielded twisted pair cable (UTP), 4 pairs, category 6, stranded (patch), indoor, without spacer
Description Materials:
Technical characteristics
Ordering information
Specifications
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 6, stranded (patch) 4 separately foil-shielded pairs Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: PVC Shield: every pair is separately shielded with polyester aluminum foil, which covers 100% of twisted pair Conductor diameter: 7x0.006 (7x0.16 mm) (26 AWG) Insulated conductor diameter: 0.038 (0.98 mm) Outer cable diameter: 0.23 (5.9 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Operating temperature: +23F to +140F (5C to +60C) Weight per 1000 ft: 26.9 lbs (12.2 kg) Standard package: 1640 ft (500 m) STP4-C6-PATCH-INDOOR Shielded twisted pair cable (STP), 4 pairs, category 6, stranded (patch), indoor
Description
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
129
Specifications
Meets IEC 61156-5, ISO/IEC 11801 and EIA/TIA 568-B.2-1 requirements Fire protection CM The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 6, stranded 4 separately foil-shielded pairs General shield: wire braid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: PVC Shield: every pair is separately shielded with polyester aluminum foil, which covers 100% of twisted pair and wire braid cover 65 % minimum Conductor diameter: 7x0.006 (7x0.16 mm) (26 AWG) Insulated conductor diameter: 0.038 (0.98 mm) Outer cable diameter: 0.230.008 (60.2 mm) Jacket thickness: 0.015 (0.4 mm) Minimum bend radius: 8 outer cable diameters Conductor elongation: 14% minimum Operating temperature: +23F to +140F (5C to +60C) Weight per 1000 ft: 28.9 lbs (13.1 kg) Standard package: 1640 ft (500 m) SSTP4-C6-PATCH-INDOOR Shielded twisted pair cable (SSTP), 4 pairs, category 6, stranded (patch), indoor
Description
Materials:
Technical characteristics
Ordering information
Unshielded Twisted Pair Cable (UTP), 4 pairs, Solid, Outdoor, with Spacer
UTP4-C6-SOLID-OUTDOOR-40
Specifications
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Unshielded Copper cable, 4 pairs, category 6, solid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE The cable jacket: UV resistant black PE Conductor diameter: 0.0210.0004 (0.540.01 mm) (24 AWG) Insulated conductor diameter: 0.0380.008 (0.990.2 mm) Outer cable diameter: 0.240.008 (6.20.2 mm) Jacket thickness: 0.025 (0.65 mm) Pulling strength: 130 N maximum Minimum bend radius: 4 outer cable diameters Conductor elongation: 14% minimum Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 27 lbs (12.3 kg) Standard package: 1640 ft (500 m) UTP4-C6-SOLID-OUTDOOR-40 Unshielded twisted pair cable (UTP), 4 pairs, category 6, solid, outdoor, with spacer
Description Materials:
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
130
Copper Cables
Specifications
Meets ANSI/EIA/TIA 568-B.2-1 requirements Fire protection CMX The cable meets UL 1581 VW-1 fire safety standard Shielded Copper cable, 4 pairs, category 6, solid 4 separately foil-shielded pairs Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: UV resistant black PE Shield: every pair is separately shielded with polyester aluminum foil, which covers 100% of twisted pair Conductor diameter: 0.220.0004 (0.570.01 mm) (23 AWG) Insulated conductor diameter: 0.056 (1.43 mm) Outer cable diameter: 0.3 (7.8 mm) Jacket thickness: 0.027 (0.7 mm) Pulling strength: 130 N maximum Minimum bend radius: 4 outer cable diameters Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 35.6 lbs (16.2 kg) Standard package: 1640 ft (500 m) STP4-C6-SOLID-OUTDOOR Shielded twisted pair cable (STP), 4 pairs, category 6, solid, outdoor
Description
Materials:
Technical characteristics
Ordering information
Description
Materials:
Schematic symbols: Jacket Shield-foil Drain wire Protective skin Solid twisted pair
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
131
At present, Category 7 is the only cable standard which allows 10GBase-T over 328 ft (100 m). Category 6 (ISO 11801, E class) presents a cabling system with unshielded twisted pairs among others, whereas category 7 (ISO 11801, F class) presupposes the same cabling system but with shielded twisted pairs only. Category 7/F class cable is rated for transmission frequencies of up to 600 MHz, which is considerably higher than category 6 transmission frequencies (up to 250 MHz). This is due to the characteristics of its construction: the pairs consist of conductors with minimum diameters of 0.023 (0.58 mm). This standard also specifies individually-shielded pairs inside an overall shield. Besides these high characteristics, individually-shielded pairs can be separated inside the cable and used for different applications which require a lack of mutual crosstalk. For example, two pairs can be used for data transmission, another pair for an analog telephone line, and the other for video transmission.
Max propagation delay at frequency 1 MHz 1.61 ns/ft (5.3 ns/m) at frequency 10 MHz 1.52 ns/ft (5.0 ns/m) at frequency 100 MHz 1.52 ns/ft (5.0 ns/m)
Shielded Twisted Pair Cable (SSTP), 4 pairs, Solid, Indoor, 23 AWG, LSZH
SSTP4-10GBE-SOLID-INDOOR
Specifications
Meets IEC 61156-5, IEC 61156-5 category 5e, 6, 7 requirements and ISO/IEC 11801 category 7 requirements Fire protection CM The cable meets UL VW-1, IEC 60332-1 fire safety standard Shielded Copper cable, 4 pairs, category 7 (1000 MHz, 10GbE), solid 4 separately foil-shielded pairs General shield: wire braid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: LSZH (low smoke zero halogen) Shield: every pair is separately shielded with polyester aluminum foil (foil is outside), which covers 100% of twisted pair General shield: tin copper braid 60% minimum Conductor diameter: 0.022 (0.57 mm) (23 AWG) Outer cable diameter: 0.33 (8.4 mm) Operating temperature: 22F to +158F (30C to +70C) Weight per 1000 ft: 49.1 lbs (22.3 kg) Standard package: 1640 ft (500 m) SSTP4-10GBE-SOLID-INDOOR Shielded twisted pair cable (SSTP), 4 pairs, category 7, solid, indoor, 23 AWG, LSZH
Description
Materials:
Schematic symbols: Jacket Shield-braid Shield-foil Solid twisted pair Drain wire
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
132
Copper Cables
Shielded Twisted Pair Cable (SSTP), 4 pairs, Solid, Indoor, 22 AWG, LSZH
SSTP4-C7-SOLID-INDOOR
Specifications
Meets IEC 61156-5, IEC 61156-5 category 5e, 6, 7 requirements and ISO/IEC 11801 category 7 requirements Fire protection CM The cable meets UL VW-1, IEC 60332-1 fire safety standard Shielded Copper cable, 4 pairs, category 7 (1000 MHz, 10GbE), solid 4 separately foil-shielded pairs General shield: wire braid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: LSZH (low smoke zero halogen) Shield: Shield: every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair General shield: tin Copper braid 60% minimum Conductor diameter: 0.025 (0.64 mm) (22 AWG) Outer cable diameter: 0.32 (8.2 mm) Operating temperature: 22F to +158F (30C to +70C) Weight per 1000 ft: 47.7 lbs (21.3 kg) Standard package: 1640 ft (500 m) SSTP4-C7-SOLID-INDOOR Shielded twisted pair cable (SSTP), 4 pairs, category 7, solid, indoor, 22 AWG, LSZH
Schematic symbols: Jacket Shield-braid Drain wire Shield-foil Solid twisted pair
Description
Materials:
Technical characteristics
Ordering information
Shielded Twisted Pair Cable (SSTP), 4 pairs, Stranded (patch), Indoor, 26 AWG, LSZH
SSTP4-C7-PATCH-INDOOR
Specifications
Meets IEC 61156-5, IEC 61156-5 category 5e, 6, 7 requirements and ISO/IEC 11801 category 7 requirements Fire protection CM The cable meets UL VW-1, IEC 60332-1 fire safety standard Shielded Copper cable, 4 pairs, category 7 (1000 MHz, 10GbE), stranded (patch) 4 separately foil-shielded pairs General shield: wire braid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: LSZH (low smoke zero halogen) Shield: every pair is separately shielded with polyester aluminum foil (foil iis on the outside), which covers 100% of twisted pair General shield: tin Copper braid 65 % minimum Conductor diameter: 7x0.006 (7x0.16 mm) (26 AWG) Outer cable diameter: 0.230.008 (6.00.2 mm) Operating temperature: 22F to +158F (30C to +70C) Weight per 1000 ft: 29.6 lbs (13.4 kg) Standard package: 1640 ft (500 m) SSTP4-C7-PATCH-INDOOR Shielded twisted pair cable (SSTP), 4 pairs, category 7, stranded (patch), indoor, 26 AWG, LSZH
Description
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
133
Shielded Twisted Pair Cable (SSTP), 4 pairs, Solid, Outdoor, 22 AWG, LSZH
SSTP4-C7-SOLID-OUTDOOR-40
Specifications Meets IEC 61156-5, IEC 61156-5 category 5e, 6, 7 requirements and ISO/IEC 11801 category 7 requirements Fire protection CMX The cable meets UL VW-1, IEC 60332-1 fire safety standard Shielded Copper cable, 4 pairs, category 7 (1000 MHz, 10GbE), solid 4 separately foil-shielded pairs General shield: wire braid Cable is used for outdoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: UV resistant black PE Shield: Shield: every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair General shield: tin Copper braid 55 % minimum The insulated conductor diameter: 0.06 (1.56 mm) Pulling strength: 140 N maximum Minimum bend radius: 8 outer cable diameters Operating temperature: 40F to +140F (40C to +60C) Weight per 1000 ft: 47 lbs (21.3 kg) Standard package: 1640 ft (500 m) SSTP4-C7-SOLID-OUTDOOR-40 Shielded twisted pair cable (SSTP), 4 pairs, category 7, solid, outdoor, 22 AWG, LSZH
Description
Materials:
Technical characteristics
Ordering information
Schematic symbols: Jacket Shield-braid Drain wire Shield-foil Solid twisted pair
Resistance unbalance
2% max
Transfer impedance at frequency 30 MHz Impedance at frequency 11200 MHz Insulation resistance at t=20C Capacitive unbalance at frequency 1 kHz
1005 Ohm 244.62 MOhm/mile (152 MOhm/km min) 0.46 pF/ft (1.5 pF/m) 13.17pF/ft (43 pF/m)
Cables of category 7 and 8 have essential improvements in the construction of their pair shields. The cross-section of the shielded twisted pair appears not to be round or oval as it had been, but is a definitely shaped sector. Four-Pairs taken together constitute a complete circle. Thus, the wire braid wraps much smoother around the cable core of twisted pairs than it does in any other cable. Additionally, in comparison with SSTP cables of other constructions, this cable looks smoother and tighter which means it can be more conveniently laid and more easily pulled through the cable duct. The improvement in insulation material in the category 8 cables results in a lower rate of attenuation per unit length. This positively affects the cable itself and the wiring as a whole. The crosstalk attenuation for upper frequencies is 2030 dB higher than would be expected. Thus, the twisted pair stays protected up to a frequency of 1000 MHz.
Maximum voltage
60 V RMS
Propagation velocity
79-80%
Dielectric rigidity
www.hyperline.com
1-888-HYPER4U
134
Copper Cables
Shielded Twisted Pair Cable (SSTP), 4 pairs, Solid, Indoor, 22 AWG, LSZH
SSTP4-C8-SOLID-INDOOR
Specifications
Meets ISO/IEC 11801 (2nd edition) and exceeds ISO/IEC 11801 for D, E, F classes and IEC 61156-5, IEC 61156-7 category 5e, 6, 7 requirements Fire protection CM The cable meets UL VW-1, IEC 60332-1 fire safety standard Shielded Copper cable, 4 pairs, category 8, solid 4 separately foil-shielded pairs General shield: wire braid Cable is used for indoor installation Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: HDPE, film-porous-film structure The cable jacket: LSZH (low smoke zero halogen) Shield: every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair General shield: tin Copper braid 70% minimum Conductor diameter: 0.025 (0.64 mm) (22 AWG) Outer cable diameter: 0.34 (8.7 mm) Operating temperature: 22F to +158F (30C to +70C) Weight per 1000 ft: 53.8 lbs (24.4 kg) Standard package: 1640 ft (500 m) SSTP4-C8-SOLID-INDOOR Shielded twisted pair cable (SSTP), 4 pairs, category 8, solid, indoor, 22 AWG, LSZH
Schematic symbols: Jacket Shield-braid Drain wire Shield-foil Solid twisted pair
Description
Materials:
Technical characteristics
Ordering information
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
135
Technical characteristics
Ordering information
Technical characteristics
Ordering information
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
136
Copper Cables
Description Materials:
The cable is designed for telecommunications. Conductive material: annealed soft electrolytic copper wire, consisting of 7 cores Insulation color: black, red, green, yellow Jacket material: PVC (polyvinylchloride) Conductor diameter: 7x0.005 (7x0.12 mm) 28 AWG Insulation diameter: 0.040.002 (0.950.05 mm) UTC2x2x0.12-C2-PATCH-INDOOR Telephone cable, category 2, stranded (patch), ribbon, 4 wires
Meets MIL-C-17 standard RG-6 coaxial cable is used in the networks of satellite and cable television Conductor: Copper steel wire Dielectric: low density cellular polyethylene Shield: aluminum foil and copper wire braid Jacket material: PVC (polyvinylchloride) Wave impedance: 75 Ohm Conductor diameter: 0.04 (1.02 mm) (18 AWG) Dielectric diameter: 0.18 (4.57 mm) Outer jacket thickness: 0.031 (0.8 mm) Outer cable diameter: 0.27 (6.9 mm) Shield: 0.006 (0.16 mm), cover 60% minimum, aluminum foil Test frequency: up to 3 GHz Voltage rating: 3000 V Temperature range: 4F to +176F (20C to +80C) Weight per 1000 ft: 30.9 lbs (14 kg) COAX-RG6 Coaxial cable
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
137
Technical characteristics
Ordering information
Technical characteristics
Ordering information
Technical characteristics
Ordering information
www.hyperline.com
1-888-HYPER4U
138
Copper Cables
Specifications Description
Meets MIL-C-17 standard RG-11 coaxial cable is used in the networks of satellite and cable television Conductor: Copper steel wire Dielectric: low density cellular polyethylene Shield: aluminium foil and copper wire braid Jacket material: PVC (polyvinylchloride) Wave impedance: 75 Ohm Conductor diameter: 0.06 (1.62 mm) (14 AWG) Dielectric diameter: 0.28 (7.11 mm) Outer jacket thickness: 0.04 (1.1 mm) Outer cable diameter: 0.4 (10.16 mm) Shield: 0.007 (0.18 mm), cover 60% minimum, aluminium foil Test frequency: up to 3 GHz Voltage rating: 5000 V Temperature range: 4F to +176F (20C to +80C) Weight per 1000 ft: 66.5 lbs (30.2 kg) Minimum bend radius: (cabling) 4.5 (114.3 mm) Pulling tension: 259.9 lbs (117.9 kg) Capacitive resistance: 53.1 pF/m Signaling rate: 83% COAX-RG11 Coaxial cable
Materials:
Technical characteristics
Ordering information
Specifications Description
Meets MIL-C-17 standard RG-59 coaxial cable is used in the networks of satellite and cable television Conductor: Copper steel wire Dielectric: low density cellular polyethylene Shield: aluminium foil and copper wire braid Jacket material: PVC (polyvinylchloride) Wave impedance: 75 Ohm Conductor diameter: 0.03 (0.81 mm) (20 AWG) Dielectric diameter: 0.14 (3.66 mm) Outer jacket thickness: 0.035 (0.9 mm) Outer cable diameter: 0.24 (6.02 mm) Shield: 0.006 (0.16 mm), cover 67% minimum, aluminium foil Test frequency: up to 1 GHz Voltage rating: 2300 V Temperature range: 4F to +176F (20C to +80C) Weight per 1000 ft: 23.5 lbs (10.7 kg) Minimum bend radius: (cabling) 2.5 (63.5 mm) Pulling tension: 50 lbs (22.7 kg) Capacitive resistance: 86.9 pF/m Signaling rate: 73% COAX-RG59 Coaxial cable
Materials:
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com
Copper Cables
139
Specifications Description
The cable meets UL 1581 VW-1 standard The cable consists of 2 RG-6 coaxial cables designed for cable television signal or any other similar applications, transfer 2 unshielded cables of category 5e (UTP) designed for data transfer , and fiber optic cable. Cable is used for indoor installation. Conductive material: copper steel wire, monolithic; annealed soft electrolytic copper wire; fiber optic 62.5/125; onductor insulation: HDPE Fiber insulation: secondary buffer coating (tight buffer) Dielectric: low density cellular polyethylene Inner jacket: fire-resistant PVC-compound; outer jacket: PVC-compound Outer cable diameter: 0.63 (16 mm) Minimum bend radius: 7.08 (180 mm) Installation temperature: +32F to +104F (0C to +40C) Operating temperature: +14F to +140F (10C to +60C) Weight per 1000 ft: 136.4 lbs (61.9 kg) Copper cable Conductor diameter: 0.02 (0.55 mm) (24 AWG) Insulated conductor diameter: 0.0350.0008 (0.90.02 mm) Fiber optic cable: Fiber diameter: 2x1251m Fiber jacket diameter: 900 m Coaxial cable: Conductor diameter: 0.04 (1.02 mm) (18 AWG) Dielectric diameter: 0.18 (4.57 mm) Outer jacket thickness: 0.031 (0.8 mm) Cable outer diameter: 0.27 (6.9 mm) Shield: 0.006 (0.16 mm), cover 60% minimum, aluminum foil CC-2RG6-2U5eS-FO Multi-service Communication Hybrid Cable
Materials:
Technical characteristics
Schematic symbols: Jacket Rip-cord Protective skin Copper cable Coaxial cable Fiber optic cable
Ordering information
Technical characteristics
Schematic symbols: Jacket Rip-cord Steel wire Protective skin Copper cable Fiber optic cable
Ordering information
www.hyperline.com
1-888-HYPER4U
140
Copper Cables
Materials:
Schematic symbols: Jacket Shield-braid Protective skin Copper cable Coaxial cable
Technical characteristics
Ordering information
Materials:
Schematic symbols: Jacket Rip-cord Protective skin Copper cable Fiber optic cable
Technical characteristics
Ordering information
1-888-HYPER4U
www.hyperline.com