Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
BILL NO - 6
CHILLER / SERVICE COMPOUND
OUND
PK1/6/Section 9 -
PK1/6/Section 10 - Ironmongery PK1/6/Section 11 - Mechanical Engineering Installation Plumbing & Fire fighting HVAC Installation
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. SITE WORKS Site works measured under Bill No10. DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Foundation Incl GF Slab 6.1 RATE (R.O.) AMOUNT (R.O)
QTY.
UNIT
Note
FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) EXCAVATION A B Excavation for pit foundation Excavation fro trench/ strip Disposal C Load and remove surplus excavated material from site including providing suitable tip as specified Allow for removal of mud accumulations from site including providing suitable tip as specified Filling F 150mm Thick compacted hard core filling including compaction as specified 1,125 75 m3 m3
1,200
m3
Item
2,387
m2
To Collection R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) Cont'd EXCAVATION (Cont'd) Anti-termite treatment as specified A Anti-termite treatment to soil under building, applied strictly in accordance with the manufacturer's printed instructions including the provision for producing 10year guarantee (Approx. area 2387m2) CONCRETE WORK Plain poured OPC concrete, cube strength 220kg/cm as specified B Blinding 100mm thick Reinforced poured vibrated OPC concrete grade M35 as specified C D E F G H Isolated footings Column shafts Plinth beams Strip footings Cable trench (base and walls) Allow for slab on grade including slab thickening (Approx. area 760m2) DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Foundation Incl GF Slab 6.1 RATE (R.O.) AMOUNT (R.O)
QTY.
UNIT
Item
1,138
m2
41 6 41 47 8
m3 m3 m3 m3 m3
Item
To Collection R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) Cont'd REINFORCEMENT High yield deformed steel bar reinforcement, characteristic yield strength of steel - 460N/mm2 as specified A B C D E F Isolated footings Column shafts Plinth beams Strip footings Cable trench (base and walls) Allow for mesh reinforcements (slab on grade) - Approx. area 760m2 DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Foundation Incl GF Slab 6.1 RATE (R.O.) AMOUNT (R.O)
QTY.
UNIT
kg kg kg kg kg
Item
To Collection R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) Cont'd Formwork to give 'as struck' finish A B C D E Sides of, column footings Sides of, column Shafts Ditto, plinth beams Sides of strip footings Sides of cable trench, walls and base MISCELLANEOUS WORKS (Provisional) Cable trenches F Allow for construction of any other cable trenches required for MEP works complete with excavation and earth works, structural concrete works, waterproofing, galvanized steel checked plate covers etc. as specifications and shown on drawings No. 002/MU/11/2038/E/4001 DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Foundation Incl GF Slab 6.1 RATE (R.O.) AMOUNT (R.O)
QTY.
UNIT
m2 m2 m2 m2 m2
Item
To Collection R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) Cont'd SUNDRIES Waterproofing (As drawing No. 002/MU/10/ST-01 & 03) Prepare and apply approved type bituminous waterproofing system, apply to concrete surfaces below ground level including hemple coal tur epoxy paint as specified A B C D E Laid horizontally over blinding (measured separately) Allow for slab on grade Laid vertically Laid approved type protection board 25mm thick protection screed as specified (for wall and column footings) as shown on drawing 002/MU/10/ST01 & 03 1000 Gauge plastic damp proof membrane (for cable trench) Forming 20mm thick isolation joint in floor bed filled with ethylene polymer layer Forming 25mm thick expansion joint in floor slab and beams complete with compressible filler and ends covered with sealant Allow for construction joints as specified DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Foundation Incl GF Slab 6.1 RATE (R.O.) AMOUNT (R.O)
QTY.
UNIT
382
m2 Item
1,199 1,199
m2 m2
312
m2
81
m2
Item
m2 Item
To Collection R.O.
1142-04-2012
BILL NO. 6 CHILLER / SERVICE COMPOUND Foundation Incl GF Slab 6.1 RATE (R.O.) AMOUNT (R.O)
QTY.
UNIT
FOUNDATIONS INCLUDING GROUND FLOOR SLAB (PROVISIONAL) Carried to Summary of Bill No. 6 Summary
R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. CONCRETE WORK Reinforced poured vibrated OPC concrete grade M35 DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Concrete Work 6.2 RATE (R.O.)
QTY.
UNIT
A B C D E F G
Columns Beams Suspended slabs 120mm thick Ditto, 140mm thick Lintels Ramp Steps
29 46 11 94 2 4 1
m3 m3 m3 m3 m3 m3 m3
To Collection R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. CONCRETE WORK (Cont'd) REINFORCEMENT High yield deformed steel bar reinforcement, characteristic yield strength of steel - 460N/mm2 as specified A B C D E F Columns Beams Suspended slabs Lintels Allow for ramps Steps DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Concrete Work 6.2 RATE (R.O.)
QTY.
UNIT
kg kg kg kg Item
110
kg
1142-04-2012
BILL NO. 6 CHILLER / SERVICE COMPOUND Concrete Work 6.2 RATE (R.O.)
QTY.
UNIT
To Collection R.O. CONCRETE WORK (Cont'd) Formwork to give 'stuck' finish A B C D E F Sides of columns Sides and soffit of beams Sides and soffit of lintel 120mm Wide edge of slab 140mm Ditto, Sides of ramps Formwork to give 'fair face' finish G Soffit of suspended slab MISCELLANEOUS WORKS H Allow for construction of bases for fire fighting water tank (size 11300 x 300 x 500mm ) SUNDRIES J K Allow for construction joint complete as specified Allow for providing ties between concrete columns/walls and block work Item 661 m2 465 523 7 23 103 4 m2 m2 m2 m m m2
Item
Item
1142-04-2012
BILL NO. 6 CHILLER / SERVICE COMPOUND Concrete Work 6.2 RATE (R.O.)
QTY.
UNIT
To Collection R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. CONCRETE WORK Carried to Summary of Bill No. 6 Summary DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Concrete Work 6.2 RATE (R.O.) R.O.
QTY.
UNIT
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
To Collection R.O.
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
SERVICE COMPOUND
1142-04-2012
SERVICE COMPOUND
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. MASONRY Note: 1. Block work rates are to include forming recess panels, working on projections and the like, if these items are not specifically measured 2. The rates for block work are to include reinforcement and concrete filling adjacent to door, window and other openings, between concrete and block work and inter sections as described in the specifications 3. Rates are to include for providing galvanized wall ties between wall panels at cavity walls, as specified BLOCKWORK Precast ordinary Portland cement solid non-load bearing block work in cement sand mortar as specified A B 200mm Walls 200mm Parapet wall Precast ordinary Portland cement Claustra non-load bearing block work in cement sand mortar as specified C 200mm Walls DESCRIPTION
QTY.
UNIT
939 55
m2 m2
535
m2
To Collection
R.O.
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. MASONRY (Cont'd) BLOCKWORK (Cont'd) SUNDRIES Wall end Galvanized mild steel butterfly pattern wall ties one end cast into concrete and other end built into joint of block walls as specified A 200mm Solid walls Wall head Compressible filler board 12mm thick set between top of block work and soffits of reinforced concrete structure B C 200mm Solid walls 200mm Claustra walls DESCRIPTION
QTY.
UNIT
167
368 327
m m
1142-04-2012
BILL NO. 6 CHILLER / SERVICE COMPOUND Masonry 6.3 RATE (R.O.) R.O.
QTY.
UNIT To Collection
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. MASONRY Carried to Summary of Bill No. 6 Summary DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Masonry 6.3 RATE (R.O.) R.O.
QTY.
UNIT
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. METAL WORKS NON STRUCTURAL METAL WORKS (Cont'd) Aluminium Windows Supply and installation of glazed window comprising of white powder coated aluminium medium section frames, sub frames, beadings, 6mm single tinted glazing panels including specified ironmongery, finishes, pointing around frames in mastic, all ancillary items on and including fixing to concrete or block work as drawings and specifications DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Metal Works 6.4 RATE (R.O.)
Qty
UNIT
Window type W01, overall size 1200 x 1200mm fixed window Ladders
16
No
Item
Allow for GRP grating or approved type grating for cable trenches (Approx area 42 Sq.m)
Item
To Collection R.O.
1142-04-2012
BILL NO. 6 CHILLER / SERVICE COMPOUND Metal Works 6.4 RATE (R.O.)
Qty
UNIT
COLLECTION PK1/6.4/1
METAL WORKS
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. Carried to Summary of Bill No. 6 Summary DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Metal Works 6.4 RATE (R.O.) R.O.
Qty
UNIT
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
To Collection R.O.
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. ROOFING Reinforced bitumen membrane system to inverted roof covering generally COVERING AND LINING Roof membrane, flexible, preformed waterproof membrane comprising self- adhesive rubber/bitumen compound bonded to up stand and edges, applied strictly in accordance with manufacturers printed instructions including all necessary additional strips at angle fillets, intersections, etc., complete with mastic pointing, all as per drawing No. 002/X/A(27)01 and as specified DESCRIPTION
QTY.
UNIT
B C
To skirting and upstand minimum 300mm high Allow for dressing roofing system in to and around rain water roof outlets Solar reflective second layer of self-adhesive reflective aluminium membrane for Exposed roofing as specification
125
Item
D E
Skirting minimum 300mm girth Allow for machine plinths Extruded polyurethane rigid foam insulation board (density 55kg/CUM)as specified
125
m Item
50mm Thick covering, laid loose 1000G Polythene sheet (Min. lapping 300mm) separation layer as detailed
770
m2
To roof slab
770
m2
1142-04-2012
QTY.
UNIT
To Collection R.O. ROOFING (Cont'd) COVERING AND LINING (Cont'd) Roof finish A 300 x 300 x 30mm Thick concrete paving slabs laid on and including 30mm thick levelling screed as detail 770 Miscellaneous items B Allow for dressing roofing system in to and around pipe work, plinths, column bases etc. on roof to make a complete roofing system Allow for waterproofing to roof plinths and duct cover slabs as specified Forming of 20 x 20mm groove in parapet to receive waterproofing membrane and solar shield (measured separately) m2
Item
Item
125
1142-04-2012
QTY.
UNIT
To Collection R.O. ROOFING (Cont'd) COVERING AND LINING (Cont'd) FLASHING Aluminium flashing fixed to masonry / concrete wall / parapet wall including sealant, surface treatment, timber battens as specified A Cover flashing 100 - 450mm girth bent to required profile with non ferrous clip, with tanalised batten shot fired to concrete/block work through membrane (provisional) SCREED B 70mm (minimum) Thick screed laid to falls on roof slab as specified 30mm Thick levelling screed over 1000G Polythene membrane (Measured separately) as specified 770 D 50 x 50mm Angle fillet in PCC (1:3:6, 10mm) GRP Roof Supply and installation of GRP roof complete with supporting structure including all fixing accessories as drawings and specifications E Over transformer yard area, including necessary frames and fixing accessories as specified SUNDRIES Testing F Allow for flood test to a depth of 50mm for continuous 24hour period 125 m2 m
125
770
m2
140
m2
Item
1142-04-2012
QTY.
UNIT
To Collection R.O.
1142-04-2012
QTY.
UNIT
R.O.
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
SERVICE COMPOUND
1142-04-2012
SERVICE COMPOUND
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
To Collection R.O.
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. DOORS AND FRAMES Note: Rates for doors and frames measured as doorsets shall also include for the following: 1) All hardwood shall be best quality as specified 2) Sizes stated are structural opening sizes 3) Door leaf/jambs, heads and meeting styles of all external doors to be sealed with approved weather strips and neoprene gasket 4) Approved type damp proof membrane for, all faces, edges and ends of timber in contacts with concrete, block work, plaster, render, marble or metal surfaces DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Door & Frames 6.6 RATE (R.O.)
QTY.
UNIT
44mm thick solid timber louvered door with complete with frames, sub frames, hard wood lipping, and architraves etc., fixed to concrete or block works including all ironmongery, fixing accessories, and protective and decorative finishes as specified
Double leaf louverd door, type D1, overall size 1800 x 2200mm Single leaf louverd door, type D2, overall size 1000 x 2200mm
No
No
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. Carried to Summary of Bill No. 6 Summary DESCRIPTION
BILL NO. 6 CHILLER / SERVICE COMPOUND Door & Frames 6.6 RATE (R.O.) R.O.
QTY.
UNIT
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
SERVICE COMPOUND
AMOUNT (R.O)
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM DESCRIPTION NO. CARPENTRY AND JOINERY
BILL NO. 6 CHILLER / SERVICE COMPOUND Carpentry & Joinery 6.7 QTY. UNIT RATE (R.O.)
1142-04-2012
1142-04-2012
MOD/RAFO PACKAGE - 1 MUSANAH (SAMAD) ITEM NO. FINISHES INTERNAL FINISHES (Cont'd) Plastering Note: 1.Plastering rates are to include forming recess panels, working on projections and the like, if these items are not specifically measured Plastering to walls; 15-20mm thick to receive paint finish including MS corner beads and all related accessories to complete works, applied in accordance with the specifications and drawings A To walls DESCRIPTION
QTY.
UNIT
1,110
m2
To Collection R.O.
PK1/6.8/49 Commercial in Confidential