Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
RR2KP Series
Contact Material Contact Resistance Minimum Applicable Load Operating Time Maximum Continuous Applied Voltage (AC/DC) at 20C Minimum Set and Reset Voltage at 20C Power Consumption
Silver 30m maximum (initial value) 5V DC, 100mA 25ms maximum 110% of the rated voltage without overheating UL Recognized File No. E66043 CSA Certied File No.LR35144
E
Relays
Ordering Information
80% of the rated voltage AC: approximately 2.4VA (50Hz), 2.2VA (60Hz) DC: approximately 1.5W 100M minimum (with 500V DC megger) Between live and dead parts: 1,500V AC, 1 minute Between contact circuit and opposite coil: 1,500V AC, 1 minute Between contact circuits: 1,500V AC, 1 minute (1,000V between NO-NC contacts) 1,800 operations/hour Coil: 85C maximum; Contact: 65C maximum 0 to 6G (55Hz maximum) 100N (approximately 10G) Electrical: over 500,000 operations (120V, 10A) Mechanical: over 5,000,000 operations 30 to +70C 170g (approximately)
Order standard voltages for fastest delivery. Allow extra delivery time for non-standard voltages.
Basic Part No. RR2KP-U Coil Voltage: AC120V
Specifications
Insulation Resistance
Dielectric Strength
Frequency Response Temperature Rise Vibration Resistance Shock Resistance Life Expectancy Operating Temperature Weight
www.idec.com
E-27
RR2KP Series
Part Numbers
Relays
Contact Configuration
DPDT
Standard
RR2KP-U
60Hz
429mA 184mA 92mA 22mA 10.6mA 240mA 120mA 60mA 30mA 13.8mA
50Hz
467mA 200mA 100mA 24mA 11.5mA
E
Relays
Inductive CSA
10A 10A 10A
Nominal
10A 0.5A 10A 7.5A
UL
10A 10A 10A
Nominal
7.5A 0.5A 7.5A 5A
UL
7A 7.5A 7A
CSA
7.5A 0.5A 7.5A 7A
2. Inductive load cos = 0.3, L/R = 7ms. 3. UL/CSA motor load rating 1/4 HP at 120V AC and 1/3 HP at 240V AC.
Applicable Sockets Part Numbers: Sockets Relay RR2KP Snap DIN Rail Mount
SR3P-05 SR3P-06
Panel
SR3P-51
Springs (optional)
SR3P-06F3 SR3P-51F3
1. See Section F for details on sockets. All DIN rail mount sockets shown above can be mounted using DIN rail BNDN1000.
E-28
www.idec.com
Relays
Internal Circuit
RR2KP Series (+) 6
RR2KP Series
5 4 Reset (-) 3
7 8 9
E
Relays
9 10
9 10
Dimensions
Plug-in RR2KP
Total length from panel surface including relay socket SR3P-05A: 105 (108.5) max., SR3P-511: 87.5 (92) max.
6 5 4 7 8
3 2 1 11 10
80.5 max.
36
36
www.idec.com
E-29