Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Issue Date
V1.3 2011-09-09
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
GRFU Description
Contents
Contents
1 Introduction .............................................................................................................................. 1
1.1 Appearance ............................................................................................................................................. 1 1.2 Physical Ports ......................................................................................................................................... 1
ii
GRFU Description
1 Introduction
1
1.1 Appearance
Figure 1-1 shows the exterior of the GRFU. Figure 1-1 Exterior of the GRFU
Introduction
The GSM Radio Frequency Unit (GRFU) is a Radio Frequency (RF) unit based on the multi-carrier technology. GRFUs are installed in the indoor macro base station (including the BTS3900 and the BTS3900L) and the outdoor macro base station (namely, the BTS3900A). They are usually used in scenarios requiring large capacity.
GRFU Description
1 Introduction
Table 1-1 Physical ports of the GRFU Port Common public radio interface (CPRI) port RF port Interconnection port for receiving RF signals Power supply socket
Monitoring port
Quantity 2
Function Connects to the baseband unit (BBU3900), or to another RRU for cascading Connects to an antenna Transmits and receives the diversity signals received through an antenna channel Receives 48 V DC power Port for monitoring and maintenance
2 2
1 1
GRFU Description
2 Technical Specifications
2
2.1 Frequency Band
Frequency Band 1900M
NOTE
Technical Specifications
Table 2-1 GRFU V1 frequency band RX Frequency Band (MHz) 1,8501,890 1,8701,910 TX Frequency Band (MHz) 1,9301,970 1,9501,990
GRFU V1 modules supporting other frequency bands are replaced with GRFU V2 or V2a modules for delivery.
Table 2-2 GRFU V2 frequency band Frequency Band 900M PGSM 900M EGSM 1800M RX Frequency Band (MHz) 890915 880915 1,7101,770 1,7251,785 Table 2-3 GRFU V2a frequency band Frequency Band 900M 1800M RX Frequency Band (MHz) 885910 1,7101,755 TX Frequency Band (MHz) 930955 1,8051,850 TX Frequency Band (MHz) 935960 925960 1,8051,865 1,8201,880
GRFU Description
2 Technical Specifications
2.2 Capacity
Table 2-4 GRFU capacity Item GRFU Specification A GRFU supports a maximum of six carriers.
Table 2-6 GRFU V2 receiver sensitivity Frequency Band 900M EGSM 900M PGSM/ 1800M 1-Way Receiver Sensitivity (dBm) -113.3 -113.5 2-Way Receiver Sensitivity (dBm) -116.3 -116.5
Table 2-7 GRFU V2a receiver sensitivity Frequency Band 900M EGSM/ 1800M 1-Way Receiver Sensitivity (dBm) -113.5 2-Way Receiver Sensitivity (dBm) -116.5
Table 2-8 Typical GRFU V1 configurations (1900MHz) Number of Carriers S1 BCCH Carrier Output Power (Power Sharing Disabled) 60 W (GMSK)/40 W (8PSK) *1 BCCH Carrier Output Power (Power Sharing Enabled) 60 W (GMSK)/40 W (8PSK) *1
GRFU Description
2 Technical Specifications
Number of Carriers S2 S3 S4 S5 S6
NOTE
BCCH Carrier Output Power (Power Sharing Disabled) 40 W (GMSK)/26 W (8PSK) 27 W (GMSK)/18 W (8PSK) 20 W (GMSK)/13 W (8PSK) 12 W (GMSK)/8 W (8PSK) 10 W (GMSK)/6.6 W (8PSK)
BCCH Carrier Output Power (Power Sharing Enabled) 40 W (GMSK)/26 W (8PSK) 31 W (GMSK)/20 W (8PSK) 27 W (GMSK)/18 W (8PSK) 20 W (GMSK)/13 W (8PSK) 16 W (GMSK)/10 W (8PSK)
The maximum output power of S1 is 60 W. If 1 x 60 W is desired, you must add the license for using the 60 W output power, otherwise, S1 will be 1 x 40 W.
BCCH Carrier Output Power (Power Sharing Enabled) 60 W (GMSK)/60 W (8PSK) *1*2 40 W (GMSK)/40 W (8PSK) *2 31 W (GMSK)/31 W(8PSK) *2 27 W (GMSK)/27 W (8PSK) *3 20 W (GMSK)/20 W (8PSK) *3 20 W (GMSK)/20 W (8PSK) *3
40 W (GMSK)/40 W (8PSK) *2 27 W (GMSK)/27 W (8PSK) *2 20 W (GMSK)/20 W (8PSK) *3 16 W (GMSK)/16 W (8PSK) *3 12 W (GMSK)/12 W (8PSK) *3
The maximum output power of S1 is 60 W. If 1 x 60 W is desired, you must add the license for using the 60 W output power, otherwise, S1 will be 1 x 40 W. For S1, S2, and S3, the 8PSK output power is the same as the GMSK output power with the improvement in hardware capability. For S4, S5, and S6, the 8PSK output power is the same as the GMSK output power with the optional feature GBFD-118104 Enhanced EDGE Coverage enabled.
Table 2-10 Typical GRFU V2 configurations (1800MHz) Number of Carriers S1 S2 S3 S4 BCCH Carrier Output Power (Power Sharing Disabled) 60 W (GMSK)/40 W (8PSK) *1 40 W (GMSK)/26 W (8PSK) 27 W(GMSK)/18 W (8PSK) 20 W(GMSK)/20 W (8PSK) *2 BCCH Carrier Output Power (Power Sharing Enabled) 60 W (GMSK)/40 W (8PSK) *1 40 W (GMSK)/26 W (8PSK) 31 W (GMSK)/20 W (8PSK) 27 W (GMSK) / 27 W (8PSK) *2
GRFU Description
2 Technical Specifications
Number of Carriers S5 S6
NOTE
BCCH Carrier Output Power (Power Sharing Disabled) 16 W (GMSK)/16 W (8PSK) *2 12 W (GMSK)/12 W (8PSK) *2
BCCH Carrier Output Power (Power Sharing Enabled) 20 W (GMSK) / 20 W (8PSK) *2 20 W (GMSK)/20 W (8PSK) *2
The maximum output power of S1 is 60 W. If 1 x 60 W is desired, you must add the license for using the 60 W output power, otherwise, S1 will be 1 x 40 W. For S4, S5, and S6, the 8PSK output power is the same as the GMSK output power with the optional feature GBFD-118104 Enhanced EDGE Coverage enabled.
Multi-carrier intelligent voltage regulation, TRX working voltage adjustment, discontinuous transmission (DTX), power control, and power sharing are enabled. The power consumption listed in this section refers to the power consumption of BTS3900s with -48 V DC. TOC refers to the output power at the duplex port on the BTS.
Table 2-11 Power consumption of the BTS3900 that is configured with GRFUs (V1, 1900MHz) Configuration S4/4/4, TOC = 20 W S6/6/6, TOC = 16 W Typical Power Consumption (W) 710 710 Maximum Power Consumption (W) 1,310 1,370
Table 2-12 Power consumption of the BTS3900 that is configured with GRFUs (V2, 900MHz) Configuration S4/4/4, TOC = 20 W S6/6/6, TOC = 20 W Typical Power Consumption (W) 680 710 Maximum Power Consumption (W) 1,300 1,190
Table 2-13 Power consumption of the BTS3900 that is configured with GRFUs (V2, 1800MHz) Configuration S4/4/4, TOC = 20 W Typical Power Consumption (W) 670 Maximum Power Consumption (W) 1,290
GRFU Description
2 Technical Specifications
Multi-carrier intelligent voltage regulation, TRX working voltage adjustment, DTX, power control, and power sharing are enabled. The power consumption listed in this section refers to the power consumption of BTS3900s with AC power supply. TOC refers to the output power at the duplex port on the BTS.
Table 2-14 Power consumption of the BTS3900A that is configured with GRFUs (V1, 1900MHz) Configuration S4/4/4, TOC = 20 W S6/6/6, TOC = 16 W Typical Power Consumption (W) 790 790 Maximum Power Consumption (W) 1,470 1,540
Table 2-15 Power consumption of the BTS3900A that is configured with GRFUs (V2, 900MHz) Configuration S4/4/4, TOC = 20 W S6/6/6, TOC = 20 W Typical Power Consumption (W) 760 790 Maximum Power Consumption (W) 1,470 1,340
Table 2-16 Power consumption of the BTS3900A that is configured with GRFUs (V2, 1800MHz) Configuration S4/4/4, TOC = 20 W S6/6/6, TOC = 20 W Typical Power Consumption (W) 750 860 Maximum Power Consumption (W) 1,450 1,430
GRFU Description
2 Technical Specifications
Multi-carrier intelligent voltage regulation, TRX working voltage adjustment, DTX, power control, and power sharing are enabled. The power consumption listed in this section refers to the power consumption of BTS3900Ls with -48 V DC. TOC refers to the output power at the duplex port on the BTS.
Table 2-17 Power consumption of the BTS3900L that is configured with GRFUs (V2) Configuration 900M S4/4/4 + 1800M S8/8/8, TOC = 20 W Typical Power Consumption (W) 1,800 Maximum Power Consumption (W) 3,730
GRFU Description
3
Acronym and Abbreviation DTX GATM GRFU PBT RF RRU TOC
Table 3-1 Acronyms and abbreviations Full Name Discontinuous Transmission GSM Antenna and TMA Control Module GSM Radio Frequency Unit Power Boost Technology Radio Frequency Remote RF Unit Transmit Power at the Top of Cabinet