Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Attenuating material
LC oscillating circuit
Signal evaluator
Switching amplifier
Switching trigger
unattenuated I attenuated sn U
Hysteresis
About Inductive Sensors Inductive sensors plan an especially important role owing to their non-contact mode of operation, their robust industrycompatible construction and the resulting high degree of reliability as well as for economic reasons. Their non-contact mode of operation means that no actuation forces are required and direct contact with the object is avoided. The completely electronic design (no moving parts or contacts) functions without wear. The electronics are encapsulated and provide a high degree of protection against vibration and shock stress as well as dirt, dust and humidity, and as a result, the majority of these sensors can also be used in extreme conditions. About Inductive Proximity Sensors An inductive proximity sensor comprises and LC oscillating circuit, a signal evaluator and a switching amplifier. (See Fig. 1) The coil of this oscillating circuit generates a high-frequency electromagnetic alternating field. This field is emitted at the sensing face of the sensor. If attenuating material nears the sensing face, eddy currents are
710
generated in the case of nonferrite metals. In the case of ferromagentic metals, hysteresis and eddy current loss also occurs. These losses draw energy from the oscillating circuit and reduce oscillation. The signal evaluator detects this reduction and converts it into a switching signal. (See Fig. 2) The terms "attenuated" and "unattenuated" are used to describe the two switching states of the inductive proximity sensors. Response curve for inductive proximity sensors The specified sensing ranges are determined in the case of axial approach along the reference axis of the sensor. (See Fig. 3) Radial approach results in a reduction of the sensing range. The edge of the switching trigger has only a small surface area. As a result, less eddy-current losses occur. The sensor therefore only reacts if the switching trigger laterally enters the alternating field relatively close to the sensing face. In the case of axial approach, the full surface of the switching trigger is exposed to the scattered electromagnetic field. Axial alignment therefore provides the maximum sensing range.
Proximity sensor
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Character
1 I
2 M
3 4 1 2
5 6 O
7 8 2 B
9 P
10 11 12 13 14 S Z U O
Character
14
3/4
Connection W Cable, PVC U Cable, PUR-PVC P Cable with connector, M8x1 T Connector, M8x1 C Connector, M12x1 K Terminals
13
12
10
6/7/8 Sensing range/ installation B Flush N Non-flush 02B 2 mm; flush 04N 4 mm; non-flush 1B5 1.5 mm; flush 2N5 2.5 mm; non-flush
Interface P DC (3/4-wire) PNP N DC (3/4-wire) NPN C DC (4-wire) PNP or NPN D DC (2-wire) A AC 2-wire U AC/DC 2-wire NAMUR
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
711
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
712
DC
AC
AC
DC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
713
IM 04 Miniature
Inductive Proximity Sensors Highlights
Shielded
DC
PNP or NPN output Normally open/normally closed function High switching frequency Short circuit protection (pulsed)
Robust brass housing, nickel-plated with fine thread M4 x 0.5 mm Cable Enclosure rating IP 67 LED status indicator
IM 04 Miniature
0.9 (22)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
714
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H typ. Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 20% of Ub 0.6 V max. at Ia = 50 mA 10 mA 100 mA 10 ms 10% of sr 2% 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 0.8 Nm PUR, 3 x 0.055 mm2
Installation in metal
Switching output
PNP NPN PNP PNP
Output function
Switching frequency f in Hz
2000 2000 2000 2000
Connection type
Type
Part no.
Connection Diagram
PNP
bn bk bu
NPN + DC -
bn bk bu
+ DC -
PNP
bn bk bu
Wire color bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 05 Miniature
Inductive Proximity Sensors Highlights
Shielded
DC
PNP or NPN output Normally open/normally closed function High switching frequency Short circuit protection (pulsed)
Robust brass housing, nickel-plated with fine thread M5 x 0.5 mm Cable or connector Enclosure rating IP 67 LED status indicator
IM 05 Miniature
1.0 (25)
7 LED
M5x0.5 0.1 (3.5) 0.6 (18) 0.8 (20) LED 0.3 M5x0.5 (6.5) M8x1
1.5 (38)
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
716
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 20% of Ub 2.0 V max. at Ia = 200 mA 10 mA 200 mA 10 ms 10% of sr 1.5% 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 1.5 Nm PVC, 3 x 0.14 mm2
Switching output
PNP NPN NPN PNP NPN PNP
Output function
Switching frequency f in Hz
5000 5000 5000 5000 5000 5000
Connection type
Type
Part no.
6 011 591 6 020 155 6 020 157 6 020 110 6 020 158 6 020 159
Connection Diagram
PNP
bn bk bu
1 4 3
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 4 3
bn bk bu
1 4 3
+ DC 4 1 3
Wire color bn bk bu
Assignment + V DC NO/NC - V DC
717
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 08 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67
PNP or NPN output Normally open/normally closed function High switching frequency LED status indicator
IM 08 Standard
1.6 (40.2)
M8x1 1.4 (36.2)
1.6 (40.2)
M8x1 1.4 (35.3)
2.0 (50)
LED, 4x90 M8x1 0 .2 (4) 1.2 (31.3) M8x1
2.0 (50)
LED, 4x90 M8x1 1.5 (38) M12x1
2.4 (60)
LED, 4x90 M8x1 0 .2 (4) 1.3 (34) M12x1
2.4 (60)
Accessories Cables and connectors page 908, 909
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
718
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% 1.2 V at Ia max. 20 mA 200 mA 100 ms 2% - 10% of sr 2% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 4 Nm PVC, 3 x 0.14 mm2
Switching output
PNP NPN PNP NPN PNP NPN PNP PNP NPN PNP NPN PNP NPN PNP NPN
Output function
Switching frequency f in Hz
3000 3000 3000 3000 3000 3000 3000 3000 3000 2500 2500 2500 2500 2500 2500
Connection type
Type
Part no.
Cable 2 m Cable 2 m Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm
IM08-01B5PS-ZW1 IM08-01B5NS-ZW1 IM08-01B5PO-ZW1 IM08-01B5NO-ZW1 IM08-01B5PS-ZT1 IM08-01B5NS-ZT1 IM08-01B5PO-ZT1 IM08-01B5PS-ZC1 IM08-01B5NS-ZC1 IM08-02N5PS-ZW1 IM08-02N5NS-ZW1 IM08-02N5PS-ZT1 IM08-02N5NS-ZT1 IM08-02N5PS-ZC1 IM08-02N5NS-ZC1
6 020 215 6 020 216 6 020 217 6 020 218 6 020 219 6 020 220 6 020 221 6 020 223 6 020 224 6 020 227 6 020 228 6 020 231 6 020 232 6 020 235 6 020 236
Connection Diagram
PNP
bn bk bu
1 4 3 1 2/4 3 Contact M8 1 4 3
bn bk bu bn bk bu Assignment + V DC NO/NC - V DC
1 4 3 1 2/4 3 M8 1 4
+ DC + DC M12 3 3 4
719
PNP
bn bk bu
2 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 08 Short
Inductive Proximity Sensors Highlights
Shielded
DC
PNP or NPN output Normally open/normally closed function High switching frequency Short circuit protection (pulsed)
Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
IM 08 Short
0.6 (16)
LED, 4x90
M8x1
M8x1
0.5 (12)
1.1 (29)
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
720
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 20% of Ub 2.0 V max. at Ia = 200 mA 10 mA 200 mA 10 ms 10% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 4 Nm PVC, 3 x 0.14 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP
Output function
Switching frequency f in Hz
5000 5000 5000 5000 5000
Connection type
Type
Part no.
6 020 111 6 020 173 6 020 112 6 020 176 6 020 177
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 2 3
Wire color bn bk bu
4 1 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 08 Advanced
Inductive Proximity Sensors Highlights
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm) 13 LED
Shielded or unshielded PNP or NPN output Normally open/normally closed function High switching frequency
IM 08 Advanced
Dimensional Drawing
M8x1
1.6 (40.2)
M8x1 1.4 (36.2)
1.6 (40.2)
M8x1 1.4 (35.3)
2.0 (50)
LED, 4x90 M8x1 1.2 (31.3) M8x1
2.0 (50)
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
722
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing Installation range Sn in metal in (mm)
0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4)
10...30 V DC 10% of Ub 1.2 V at Ia max. 20 mA 200 mA 100 ms 2% - 15% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 4 Nm PVC, 3 x 0.14 mm2
Switching output
PNP NPN PNP PNP NPN PNP NPN PNP NPN PNP PNP NPN PNP NPN
Output function
Switching frequency f in Hz
3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
Connection type
Type
Part no.
Cable 2 m Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Cable 2 m Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm
IM08-02BPS-ZW1 IM08-02BNS-ZW1 IM08-02BPO-ZW1 IM08-02BPS-ZT1 IM08-02BNS-ZT1 IM08-02BPO-ZT1 IM08-02BNO-ZT1 IM08-04NPS-ZW1 IM08-04NNS-ZW1 IM08-04NPO-ZW1 IM08-04NPS-ZT1 IM08-04NNS-ZT1 IM08-04NPO-ZT1 IM08-04NNO-ZT1
7 900 001 7 900 002 7 900 003 7 900 005 7 900 006 7 900 007 7 900 008 7 900 009 7 900 010 7 900 011 7 900 013 7 900 014 7 900 015 7 900 016
Connection Diagram
PNP
bn bk bu
1 4 3
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 4 3
bn bk bu Assignment + V DC NO/NC - V DC
1 4 3 4 1
+ DC -
Wire color bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
723
IM 08 Advanced Short
Inductive Proximity Sensors Highlights
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
13 LED dimensions in inches (mm)
Shielded or unshielded PNP or NPN output Normally open/normally closed function High switching frequency
IM 08 Advanced Short
Dimensional Drawing
M8x1
1.2 (30.2)
M8x1 0.2 (4) 1.0 (26.2)
1.2 (30.2)
1.6 (40)
LED, 4x90 M8x1 0.2 (4) 0.8 (21.3) M8x1
1.6 (40)
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
724
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing Installation range Sn in metal in (mm)
0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4)
10...30 V DC 10% of Ub 1.2 V at Ia max. 10 mA 200 mA 5 ms 1% - 20% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 4 Nm PVC, 3 x 0.14 mm2
Switching output
PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN
Output function
Switching frequency f in Hz
3000 3000 3000 3000 3000 3000 2500 2500 2500 2500 2500 2500
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm
IM08-02BPS-ZWK IM08-02BNS-ZWK IM08-02BPS-ZTK IM08-02BNS-ZTK IM08-02BPO-ZTK IM08-02BNO-ZTK IM08-04NPS-ZWK IM08-04NNS-ZWK IM08-04NPS-ZTK IM08-04NNS-ZTK IM08-04NPO-ZTK IM08-04NNO-ZTK
6 025 861 6 025 862 6 025 863 6 025 864 6 025 865 6 025 866 6 025 867 6 025 868 6 025 869 6 025 870 6 025 871 6 025 872
Connection Diagram
PNP
bn bk bu
1 4 3
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 4 3
bn bk bu Assignment + V DC NO/NC - V DC
1 4 3 4 1
+ DC -
Wire color bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
725
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm)
Installation quasi flush or non-flush in metal Normally open function PNP or NPN output High switching frequency
Dimensional Drawing
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
726
Electrical and Mechanical Data Operating voltage Ub Ripple Uss Voltage drop Ud (at Ia max.) Power consumption (without load) Continuous current Ia Time delay before availability Tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 20% of Ub 2 V at Ia max. 10 mA 200 mA 100 ms 1% - 5% of sr (5% typ.) 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, chrome-plated, plastic 4 Nm PVC, 3 x 0.14 mm2
Installation in metal
* *
Switching output
PNP PNP PNP NPN PNP
Output function
Switching frequency f in Hz
1000 1000 500 500 500
Connection type
Type
Part no.
6 027 505 6 025 574 6 027 506 6 027 507 6 027 508
* Installation notes quasi flush When mounting in conductible materials the sensors have to be installed with a distance A to the surface. A Steel, metal = 1 mm / A Stainless steel = 0 mm
Connection Diagram
PNP
NPN bn bk bu 1 4 3 + DC -
bn bk bu
1 4 3
+ DC -
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 08 NAMUR
Inductive Proximity Sensors Highlights
High switching frequency Robust brass housing with nickelplated fine thread M8 x 1 Enclosure rating IP 67
IM 08 NAMUR
M8x1
1.2 (30)
page 966
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
728
Electrical and Mechanical Data Operating voltage Ub Nominal voltage Un Power consumption, attenuated Power consumption, unattenuated Internal capacitance Internal inductance Cable resistance Temperature drift EMC Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Max. data for connecting isolating unit EN 2 EX or other approved isolating amplifier: Short circuit current Ik max No load voltage Uo Power loss Pmax 5...25 V DC 8.2 V DC 1.0 mA 2.2 mA 80 nF 110 H 50 10% of sr to EN 60 947-5-2 IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 2.5 Nm PVC, 2 x 0.14 mm2, blue
50 mA 15 V 180 mW
Installation in metal
Switching output
NAMUR
Output function
Switching frequency f in Hz
2000
Connection type
Type
Part no.
Cable 2 m
IM08-01B-N-ZW0
6 021 123
Connection Diagram
Assignment + V DC - V DC
729
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
PNP or NPN output Normally open/normally closed function Short circuit protection (pulsed)
Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
IM 12 Standard
2.0 (50)
LED
2.0 (50)
M12x1 1.5 (38) M12x1 LED, 4x90 0.2 (5)
2.6 (65)
M12x1 LED, 4x90 1.7 (43)
M12x1
2.6 (65)
M8x1 M12x1 1.5 (38) LED, 4x90
0.2 (5)
2.4 (60.5)
M8x1 LED, 4x90 1.7 (43)
M12x1
2.4 (60.5)
Accessories Cables and connectors Mounting brackets page 908, 909 925
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
730
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing range Sn in (mm)
0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.08 (2) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4) 0.2 (4)
10...30 V DC 10% 1.2 V at Ia max. 20 mA 200 mA 100 ms 2% - 10% of sr 2% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 10 Nm PVC, 3 x 0.22 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP PNP NPN PNP NPN PNP
Output function
Switching frequency f in Hz
2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
Connection type
Type
Part no.
Cable 2 m Cable 2 m Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm
IM12-02BPS-ZW1 IM12-02BNS-ZW1 IM12-02BPO-ZW1 IM12-02BNO-ZW1 IM12-02BPS-ZT1 IM12-02BNS-ZT1 IM12-02BPS-ZC1 IM12-02BNS-ZC1 IM12-02BPO-ZC1 IM12-02BNO-ZC1 IM12-04NPS-ZW1 IM12-04NNS-ZW1 IM12-04NPO-ZW1 IM12-04NPS-ZT1 IM12-04NNS-ZT1 IM12-04NPS-ZC1 IM12-04NNS-ZC1 IM12-04NPO-ZC1
6 011 963 6 011 964 6 011 965 6 011 966 6 011 967 6 011 968 6 011 971 6 011 972 6 011 973 6 011 974 6 011 975 6 011 976 6 011 977 6 011 979 6 011 980 6 011 983 6 011 984 6 011 985
NPN + DC NPN + DC -
bn bk bu bn bk bu
1 4 3 1 2/4 3
+ DC + DC -
bk bu PNP bn bk bu
4 3 1 2/4 3
Contact M8 1 4 3
Assignment + V DC NO/NC - V DC
M8 1
4 3 2
731
M12 3
2 1 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 Short
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
PNP or NPN output Normally open function High switching frequency Short circuit protection (pulsed)
Robust brass housing,nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
IM 12 Short
M12x1
1.4 (35)
M12x1
LED
1.4 (35)
M12x1 LED, 4x90 0.2 (5) 1.1 (27)
M12x1
1.8 (45)
1.8 (45)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
732
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% of Ub 1.5 V at Ia max. 10 mA 300 mA 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 7.0 Nm PUR-PVC, 3 x 0.25 mm2
Switching output
PNP NPN PNP NPN PNP NPN PNP NPN
Output function
Switching frequency f in Hz
3000 3000 3000 3000 3000 3000 3000 3000
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm
1 017 426 1 017 438 1 017 428 1 017 440 1 017 427 1 017 439 1 017 429 1 017 441
Connection Diagram
PNP
bn bk bu
1 4 3
+ DC -
NPN
bn bk bu
1 4 3
Wire color bn bk bu
1 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 2-wire
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
Normally open function Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M12 x 1 mm
IM 12 2-wire
2.4 (60)
LED
2.4 (60)
M12x1 0.2 (5) 1.9 (48) M12x1 LED, 4x90
3.0 (75)
M12x1 2.1 (53) LED, 4x90
M12x1
3.0 (75)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
734
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% 2.8 V at Ia max. 3 mA 100 mA 0.8 mA 50 ms 2% - 10% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 10 Nm PVC, 2 x 0.22 mm2
Installation in metal
Output function
Switching frequency f in Hz
1500 1500 1500 1500
Connection type
Type
Part no.
Connection Diagram
bn bu
1 4
+ DC 2
Contact 1 4
Assignment + V DC - V DC 3 4 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
735
IM 12 Advanced
Inductive Proximity Sensors Highlights
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm) 17 LED
Shielded or unshielded PNP or NPN output Normally open/normally closed function High switching frequency
IM 12 Advanced
Dimensional Drawing
2.0 (50)
LED M12x1
1.6 (40)
2.0 (50)
M12x1 LED, 4x90 1.5 (38)
M12x1 0 .2 (5)
2.6 (65)
M12x1 LED, 4x90 1.7 (43)
M12x1
2.6 (65)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
736
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% of Ub 1.2 V at Ia max. 10 mA 200 mA 100 ms 1% - 15% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 10 Nm PVC, 3 x 0.22 mm2
Installation in metal
Switching output
PNP NPN PNP PNP NPN PNP PNP NPN PNP NPN PNP NPN PNP
Output function
Switching frequency f in Hz
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Connection type
Type
Part no.
Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm
IM12-04BPS-ZW1 IM12-04BNS-ZW1 IM12-04BPO-ZW1 IM12-04BPS-ZC1 IM12-04BNS-ZC1 IM12-04BPO-ZC1 IM12-08NPS-ZW1 IM12-08NNS-ZW1 IM12-08NPO-ZW1 IM12-08NNO-ZW1 IM12-08NPS-ZC1 IM12-08NNS-ZC1 IM12-08NPO-ZC1
7 900 033 7 900 034 7 900 035 7 900 037 7 900 038 7 900 039 7 900 041 7 900 042 7 900 043 7 900 044 7 900 045 7 900 046 7 900 047
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 2 3
bn bk bu
1 2 3 2
+ DC -
Contact 1 2/4 3
Assignment + V DC NO/NC - V DC
737
1 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 Advanced Short
Inductive Proximity Sensors Highlights
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm) 17 LED
Shielded or unshielded PNP or NPN output Normally open/normally closed function High switching frequency
IM 08 Advanced Short
Dimensional Drawing
1.6 (40)
LED M12x1
1.2 (30)
1.6 (40)
M12x1 LED, 4x90 1.2 (30)
M12x1 0 .2 (5)
2.1 (52.5)
M12x1 LED, 4x90 1.4 (35)
M12x1
2.1 (52.5)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
738
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% of Ub 1.5 V at Ia max. 10 mA 300 mA 100 ms 1% - 15% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...168F (-25...75C) Brass, nickel-plated, plastic 7 Nm PVC, 3 x 0.22 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN
Output function
Switching frequency f in Hz
2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm
IM12-04BPS-ZWK IM12-04BNS-ZWK IM12-04BPS-ZCK IM12-04BNS-ZCK IM12-04BPO-ZCK IM12-04BNO-ZCK IM12-08NPS-ZWK IM12-08NNS-ZWK IM12-08NPS-ZCK IM12-08NNS-ZCK IM12-08NPO-ZCK IM12-08NNO-ZCK
6 025 682 6 025 683 6 025 679 6 025 681 6 025 680 6 025 859 6 025 684 6 025 685 6 025 686 6 025 687 6 025 688 6 025 860
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 2 3
bn bk bu
1 2 3 2
+ DC -
Contact 1 2/4 3
Assignment + V DC NO/NC - V DC
739
1 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm)
Installation quasi or non-flush in metal Normally open function/normally closed function PNP or NPN output High switching frequency
Dimensional Drawing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
740
Electrical and Mechanical Data Operating voltage Ub Ripple Uss Voltage drop Ud (at Ia max.) Power consumption (without load) Continuous current Ia Time delay before availability Tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 20% of Ub 2 V at Ia max. 10 mA 200 mA 100 ms 1% - 5% of sr (5% typ.) 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, chrome-plated, plastic 10 Nm PVC, 3 x 0.34 mm2
Installation in metal
* * *
Switching output
PNP PNP PNP PNP NPN PNP
Output function
Switching frequency f in Hz
800 800 800 400 400 400
Connection type
Type
Part no.
6 027 509 6 027 510 6 027 511 6 027 512 6 027 513 6 027 514
* Installation notes quasi flush When mounting in conductible materials the sensors have to be installed with a distance A to the surface. A Steel, metal = 2 mm / A Stainless steel = 1 mm
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 2 3
Wire color bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 Harsh Environment
Inductive Proximity Sensors Highlights
DC
For harsh environment, resistant to most cutting oils Enclosure rating IP 68 Shielded or unshielded PNP or NPN output Complementary output function
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M12 x 1 mm Internal enclosure housing in technopolymer LED status indicator (NO function)
dimensions in inches (mm) 17 0.5 (12.7) M12x1 LED
IM 12 Harsh environment
Dimensional Drawing
1.3 (33)
2.6 (65)
0.5 (12.7) 1.5 (39) M12x1 LED
M12x1
2.6 (65)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
742
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating Shock and vibration stress Ambient temperature Ta Housing material Tightening torque 10...30 V DC 10% 1.2 V at Ia max. 20 mA 100 mA 100 ms 2% - 10% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 68 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 10 Nm
Switching output
Output function
Switching frequency f in Hz
Connection type
Type
Part no.
0.08 (2)
PNP complementary
2000
Connector M12 x 1 mm
IM12-02BPP-ZC1
7 902 923
0.08 (2)
NPN complementary
2000
Connector M12 x 1 mm
IM12-02BNP-ZC1
7 902 924
0.2 (4)
PNP complementary
2000
Connector M12 x 1 mm
IM12-04NPP-ZC1
7 902 925
0.2 (4)
NPN complementary
2000
Connector M12 x 1 mm
IM12-04NNP-ZC1
7 902 926
Connection Diagram
PNP 1 4 2 complementary 3 DC +
NPN 1 4 2 complementary 3 2 3 1 4
743
+ DC
Contact 1 2 3 4
Assignment + V DC NC - V DC NO
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 QuadProx
Inductive Proximity Sensors Highlights
DC
Programmable output functions in one sensor: PNP/NO, PNP/NC, NPN/NO, NPN/NC Shielded or unshielded Short circuit protection
Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator (NO function)
IM 12 QuadProx
0.2 (5)
2.4 (60)
2.4 (60)
0.2 (5)
3.0 (75)
3.0 (75)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
744
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% 1.2 V at Ia max. 30 mA 100 mA 250 ms 2% - 10% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 15 Nm PVC, 4 x 0.22 mm2
Selection Table Sensing range Sn in (mm) Installation in metal Switching output Output function Switching frequency f in Hz Connection type Type Part no.
0.08 (2)
PNP/NPN config.
config.
1000
Cable 2 m
IM12-02BCP-ZW1
7 902 927
0.08 (2)
1000
Connector M12 x 1 mm
IM12-02BCP-ZC1
7 902 928
0.2 (4)
1000
Cable 2 m
IM12-04NCP-ZW1
7 902 929
0.2 (4)
PNP/NPN config.
config.
1000
Connector M12 x 1 mm
IM12-04NCP-ZC1
7 902 930
Connection Diagram
PNP
bn wh bk bu
1 2 4 3
bn wh bk bu
1 2 4 3
+ DC -
PNP
bu wh bk bn
3 2 4 1
bu wh bk bn
3 2 4 1
+ DC -
2 3 1 4
1 2 3 4
- V DC +V DC -V DC +V DC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 Universal
Inductive Proximity Sensors Highlights
Shielded or unshielded
AC
Normally open/normally closed function Robust brass housing, nickel-plated with fine thread M12 x 1 mm
IM 12
Dimensional Drawing dimensions in inches (mm) 17 LED M12x1 0.2 (4) 0.4 (9)
1.8 (46)
2.8 (71)
0.7 (18)
2.0 (50)
2.8 (71)
0.7 (18)
17 M12x1 0.2 (4) 0.7 (18) 1/2" -20 UNF LED 1.8 (46)
3.0 (77)
17 M12x1 0.7 (18) Accessories Cables and connectors Mounting brackets page 909 925 1/2" -20 UNF LED 2.0 (50)
3.0 (77)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
746
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Continuous current Ia Peak current Ik Min. load current Residual current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Protection class Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 90...250 V AC 8.5 V AC at Ia max. 250 mA AC (... + 50 C), 200 mA AC (... + 80 C) 0.9 A (20 ms/0.5 Hz) 8 mA 3 mA (250 V AC), 1.5 mA (120 V AC) approx.10 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm 13...176F (-25...80C) Brass, nickel-plated, plastic 7 Nm PUR-PVC, 2 x 0.5 mm2
Installation in metal
Output function
Switching frequency f in Hz
25 25 25 25 25 25
Connection type
Type
Part no.
7 902 118 7 902 119 6 020 627 7 902 120 7 902 121 6 020 628
Connection Diagram
bn bu
L1 AC N
bn bu
L1 AC N
Contact Assignment 3 L1 2 1 N NC
1
747
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 12 NAMUR
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
NAMUR to DIN 19 234 High switching frequency Robust brass housing with nickel=plated fine thread M8 x 1
IM 12 NAMUR
1.2 (30)
0.4 (2)
M12x1
1.2 (30)
0.4 (2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
748
Electrical and Mechanical Data Operating voltage Ub Nominal voltage Un Power consumption, attenuated Power consumption, unattenuated Internal capacitance Internal inductance Cable resistance Temperature drift EMC Short-circuit protected Reverse polarity protected Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Max. data for connecting isolating unit EN 2 EX or other approved isolating amplifier: Short circuit current Ik max No load voltage Uo Power loss Pmax 5...25 V DC 8.2 V DC 1.0 mA 2.2 mA 230 nF 380 H 50 10% of sr to EN 60 947-5-2 Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 7.0 Nm PVC, 2 x 0.34 mm2, blue
50 mA 15 V 180 mW
Installation in metal
Switching output
NAMUR NAMUR
Output function
Switching frequency f in Hz
1200 1500
Connection type
Type
Part no.
Cable 2 m Cable 2 m
IM12-02B-N-ZW0 IM12-04N-N-ZW0
Connection Diagram
Assignment + V DC - V DC
749
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 18 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
PNP or NPN output Normally open/normally closed function Short circuit protection (pulsed)
Robust brass housing, nickel-plated with fine thread M18 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
IM 18 Standard
1.3 (32)
2.0(50)
LED M18x1
1.6 (40)
2.0 (50)
M18x1
0.3 (8)
2.5 (64)
M18x1
2.5 (64)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
750
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% 1 V at Ia max. 20 mA 400 mA 100 ms 2% - 10% of sr 2% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 30 Nm PVC, 3 x 0.34 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP PNP NPN NPN PNP NPN PNP
Output function
Switching frequency f in Hz
600 600 600 600 600 600 600 600 600 600 600
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm
IM18-05BPS-ZW1 IM18-05BNS-ZW1 IM18-05BPS-ZC1 IM18-05BNS-ZC1 IM18-05BPO-ZC1 IM18-08NPS-ZW1 IM18-08NNS-ZW1 IM18-08NNO-ZW1 IM18-08NPS-ZC1 IM18-08NNS-ZC1 IM18-08NPO-ZC1
6 011 987 6 011 988 6 011 991 6 011 992 6 011 993 6 011 995 6 011 996 6 011 998 6 011 999 6 012 000 6 012 001
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 2 3
bn bk bu
1 2 3 2
+ DC -
Contact 1 2/4 3
Assignment + V DC NO/NC - V DC
751
1 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 18 Short
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
PNP or NPN output Normally open function Short circuit protection (pulsed)
Robust brass housing, nickel-plated with fine thread M18 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
IM 18 Short
M18x1
1.6 (40)
M18x1
LED
1.6 (40)
M18x1
1.8 (45)
M18x1
1.8 (45)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
752
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% of Ub 1.5 V at Ia max. 10 mA 300 mA 10 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 25 Nm PUR-PVC, 3 x 0.25 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP NPN PNP NPN
Output function
Switching frequency f in Hz
2000 2000 2000 2000 2000 2000 2000 2000
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm
1 017 430 1 017 442 1 017 432 1 017 444 1 017 431 1 017 443 1 017 433 1 017 445
Connection Diagram
PNP
bn bk bu
1 4 3
+ DC -
NPN
bn bk bu
1 4 3
Wire color bn bk bu
1 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 18 2-wire
Inductive Proximity Sensors Highlights
Shielded or unshielded
DC
Normally open function Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M18 x 1 mm
IM 18
1.3 (32)
2.0(50)
LED M18x1
1.6 (40)
2.0 (50)
M18x1
0.3 (8)
2.5 (64)
M18x1
2.5 (64)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
754
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Load current Continuous current Ia Off-state current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% 2.8 V at Ia max. 3 mA 100 mA 0.8 mA 50 ms 2% - 10% of sr 2% of sr 10% of sr to EN 60 947-5-2 Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 30 Nm PVC, 2 x 0.34 mm2
Installation in metal
Output function
Switching frequency f in Hz
300 300 300 300
Connection type
Type
Part no.
Connection Diagram
bn bu
1 4
+ DC -
bn bu
1 2
+ DC 2
Contact 1 2/4
Assignment + V DC - V DC
755
3 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 18 Advanced
Inductive Proximity Sensors Highlights
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M18 x 1 mm Cable and connector LED status indicator
Shielded or unshielded PNP or NPN output High switching frequency Normally open/normally closed function
IM 18 Advanced
1.3 (32)
2.0(50)
LED M18x1
1.6 (40)
2.0 (50)
M18x1
0.3 (8)
2.5 (64)
M18x1
2.5 (64)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
756
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing range Sn in mm
8 8 8 8 8 8 12 12 12 12 12 12
10...30 V DC 10% of Ub 1 V at Ia max. 10 mA 400 mA 100 ms 2% - 15% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 30 Nm PVC, 3 x 0.25 mm2
Installation in metal
Switching output
PNP NPN PNP PNP NPN PNP PNP NPN PNP PNP NPN PNP
Output function
Switching frequency f in Hz
300 300 300 300 300 300 300 300 300 300 300 300
Connection type
Type
Part no.
Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm
IM18-08BPS-ZW1 IM18-08BNS-ZW1 IM18-08BPO-ZW1 IM18-08BPS-ZC1 IM18-08BNS-ZC1 IM18-08BPO-ZC1 IM18-12NPS-ZW1 IM18-12NNS-ZW1 IM18-12NPO-ZW1 IM18-12NPS-ZC1 IM18-12NNS-ZC1 IM18-12NPO-ZC1
7 900 081 7 900 082 7 900 083 7 900 085 7 900 086 7 900 087 7 900 093 7 900 094 7 900 095 7 900 097 7 900 098 7 900 099
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 2 3
Wire color bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm)
Installation quasi flush or non-flush in metal Normally open function PNP or NPN output High switching frequency
Dimensional Drawing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
758
Electrical and Mechanical Data Operating voltage Ub Ripple Uss Voltage drop Ud (at Ia max.) Power consumption (without load) Continuous current Ia Time delay before availability Tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 20% of Ub 2 V at Ia max. 10 mA 200 mA 100 ms 1% - 5% of sr (5% typ.) 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, chrome-plated, plastic 30 Nm PVC, 3 x 0.34 mm2
Installation in metal
*
Switching output
PNP NPN PNP PNP PNP
Output function
Switching frequency f in Hz
500 500 500 200 200
Connection type
Type
Part no.
6 027 515 6 027 516 6 027 517 6 027 518 6 027 519
* Installation notes quasi flush When mounting in conductible materials the sensors have to be installed with a distance A to the surface. A Steel, metal = 4 mm / A Stainless steel = 1.5 mm
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC 2
Contact 1 4 3
Assignment + V DC NO - V DC 4 3 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
759
IM 18 Harsh Environment
Inductive Proximity Sensors Highlights
DC
For harsh environment, resistant to most cutting oils Enclosure rating IP 68 Shielded or unshielded PNP or NPN output Complementary output function
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M12 x 1 mm Internal enclosure housing in technopolymer LED status indicator (NO function)
dimensions in inches (mm) 24
IM 18 Harsh environment
Dimensional Drawing
M12x1
0.3 (8)
2.5 (63)
M12x1
2.5 (63)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
760
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating Shock and vibration stress Ambient temperature Ta Housing material Tightening torque 10...30 V DC 10% 0.8 V at Ia max. 20 mA 400 mA 100 ms 2% - 10% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 68 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 40 Nm
Selection Table Sensing range Sn in (mm) Installation in metal Switching output Output function Switching frequency f in Hz Connection type Type Part no.
0.2 (5)
PNP complementary
1000
Connector M12 x 1 mm
IM18-05BPP-ZC1
7 902 931
0.2 (5)
NPN complementary
1000
Connector M12 x 1 mm
IM18-05BNP-ZC1
7 902 932
0.3 (8)
PNP complementary
1000
Connector M12 x 1 mm
IM18-08NPP-ZC1
7 902 933
0.3 (8)
NPN complementary
1000
Connector M12 x 1 mm
IM18-08NNP-ZC1
7 902 934
Connection Diagram
PNP 1 4 2 complementary 3 DC +
NPN 1 4 2 complementary 3 2 3 1 4 DC +
Contact 1 2 3 4
Assignment + V DC NC - V DC NO
761
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 18 QuadProx
Inductive Proximity Sensors Highlights
Programmable output functions in one sensor: PNP/NO, PNP/NC, NPN/NO, NPN/NC Shielded or unshielded Short circuit protection
Robust brass housing, nickel-plated with fine thread M18 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator (NO function)
IM 18 QuadProx
0.3 (8)
1.5 (37)
2.4 (60)
LED
M18x1
1.8 (45)
2.4 (60)
M18x1
3.0 (74)
M18x1
3.0 (74)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
762
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing Installation range Sn in metal in (mm) 10...30 V DC 10% 1.2 V at Ia max. 30 mA 100 mA 200 ms 2% - 10% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 40 Nm PVC, 4 x 0.34 mm2
Switching output
Output function
Switching frequency f in Hz
Connection type
Type
Part no.
0.2 (5)
300
Cable 2 m
IM18-05BCP-ZW1
7 902 935
0.2 (5)
300
Connector M12 x 1 mm
IM18-05BCP-ZC1
7 902 936
0.3 (8)
300
Cable 2 m
IM18-08NCP-ZW1
7 902 937
0.3 (8)
300
Connector M12 x 1 mm
IM18-08NCP-ZC1
7 902 938
Connection Diagram
PNP
bn wh bk bu
1 2 4 3
bn wh bk bu
1 2 4 3
+ DC -
PNP
bu wh bk bn
3 2 4 1
bu wh bk bn
3 2 4 1
+ DC -
2 3 4 1
1 2 3 4
+V DC +V DC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 18 Universal
Inductive Proximity Sensors Highlights
Shielded or unshielded Broad operating voltage range in AC and DC Normally open/normally closed function High switching frequency
IM 18 Universal Dimensional Drawing
Robust brass housing, nickel-plated with fine thread M18 x 1 mm Enclosure rating IP 67 LED status indicator
M18x1
0.4 (9)
0.3 (8)
2.0 (50)
LED
3.1 (80)
0.7 (18)
M18x1
0.4 (9)
2.3 (58)
LED
3.1 (80)
0.7 (18)
3.2 (82)
2.0 (55) 2.0 (50) M18x1 0.2 (4) LED 7/8-16 1.1 UNF
(28)
24
3.2 (82)
0.3 (8)
2.0 (55) 1.7 (42) 7/8-16 1.1 UNF 0.2 (4) LED
M18x1
(28)
24
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
764
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Continuous current Ia Peak current Ik Min. load current Residual current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Protection class Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing range Sn in (mm)
0.2 (5) 0.2 (5) 0.2 (5) 0.3 (8) 0.3 (8) 0.3 (8)
20...250 V AC / DC 6.5 V AC / 6 V DC at Ia max. 350 mA AC (...+50C), 250 mA AC (...+80C), 100 mA DC 2.2 A (20ms/0.5 Hz) 5 mA 2.5 mA (250 V AC), 1.3 mA (110 V AC), 0.8 mA (24 V DC) approx. 8 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm 13...176F (-25...80C) Brass, nickel-plated, plastic 35 Nm PUR-PVC, 2 x 0.5 mm2
Installation in metal
Output function
Switching frequency f in Hz
25 (AC) / 100 (DC) 25 (AC) / 100 (DC) 25 (AC) / 100 (DC) 25 (AC) / 100 (DC) 25 (AC) / 100 (DC) 25 (AC) / 100 (DC)
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector 3-pin Mini Cable 2 m Cable 2 m Connector 3-pin Mini
7 902 122 7 902 123 6 021 223 7 902 124 7 902 125 6 021 224
Connection Diagram
bn bu
bn bu
Wire color bn bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
765
IM 18 NAMUR
Inductive Proximity Sensors Highlights
NAMUR to DIN 19 234 Shielded or unshielded Robust brass housing, nickel-plated with fine thread M18 x 1 mm High switching frequency
IM 18 NAMUR Dimensional Drawing
1.3 (33)
0.1 (2)
M18x1
1.3 (33)
0.1 (2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
766
Electrical and Mechanical Data Operating voltage Ub Nominal voltage Un Power consumption, attenuated Power consumption, unattenuated Internal capacitance Internal inductance Cable resistance Temperature drift EMC Short-circuit protected Reverse polarity protected Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Max. data for connecting isolating unit EN 2 EX or other approved isolating amplifier: Short circuit current Ik max No load voltage Uo Power loss Pmax 5...25 V DC 8.2 V DC 1.0 mA 2.2 mA 230 nF (flush) 240 nF (non-flush) 60 H 50 10% of sr to EN 60 947-5-2 Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 35 Nm PVC, 2 x 0.34 mm2, blue
50 mA 15 V 180 mW
Installation in metal
Switching output
NAMUR NAMUR
Output function
Switching frequency f in Hz
720 300
Connection type
Type
Part no.
Cable 2 m Cable 2 m
IM18-05B-N-ZW0 IM18-08N-N-ZW0
Connection Diagram
Assignment + V DC - V DC
767
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 30 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded PNP or NPN output Normally open/normally closed function High switching frequency Short circuit protection (pulsed)
IM 30 Standard Dimensional Drawing
Robust brass housing, nickel-plated with fine thread M30 x 1.5 mm Cable or connector Enclosure rating IP 67 LED status indicator
0.5 (12)
1.5 (38)
2.4 (60)
LED
M30x1.5
2.0 (50)
2.4 (60)
M30x1.5
3.0 (76)
M30x1.5
3.0 (76)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
768
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H typ. Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% 1 V at Ia max. 20 mA 400 mA 100 ms 2% - 10% of sr 2% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 60 Nm PUR-PVC, 3 x 0.5 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP PNP NPN PNP PNP NPN
Output function
Switching frequency f in Hz
200 200 200 200 200 200 200 200 200 200
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm
IM30-10BPS-ZW1 IM30-10BNS-ZW1 IM30-10BPS-ZC1 IM30-10BNS-ZC1 IM30-10BPO-ZC1 IM30-15NPS-ZW1 IM30-15NNS-ZW1 IM30-15NPO-ZW1 IM30-15NPS-ZC1 IM30-15NNS-ZC1
6 020 274 6 020 275 6 020 278 6 020 279 6 020 280 6 020 282 6 020 283 6 020 284 6 020 286 6 020 287
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu Wire color
1 2 3
bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 30 Short
Inductive Proximity Sensors Highlights
Shielded or unshielded PNP or NPN output Normally open function Short circuit protection (pulsed)
Robust brass housing, nickel-plated with fine thread M30 x 1.5 mm Cable or connector Enclosure rating IP 67 LED status indicator
IM 30 Short
36 LED M30x1.5
1.0 (25)
1.6 (40)
LED
M30x1.5
1.6 (40)
M30x1.5
0.9
2.0 (50)
M30x1.5
2.0 (50)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
770
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing range Sn in (mm)
0.4 (10) 0.4 (10) 0.4 (10) 0.6 (15) 0.6 (15) 0.6 (15)
10...30 V DC 10% of Ub 1.5 V at Ia max. 10 mA 300 mA 10 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 50 Nm PUR-PVC, 3 x 0.5 mm2
Installation in metal
Switching output
PNP NPN PNP PNP NPN PNP
Output function
Switching frequency f in Hz
500 500 500 500 500 500
Connection type
Type
Part no.
1 017434 1 017 446 1 017 436 1 017 435 1 017 447 1 017 437
Connection Diagram
PNP
bn bk bu
1 4 3
+ DC -
NPN
bn bk bu
1 4 3
Wire color bn bk bu
3 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 30 2-wire
Inductive Proximity Sensors Highlights
Shielded or unshielded Normally open/normally closed function High switching frequency Short circuit protection (pulsed)
IM 30 2-wire Dimensional Drawing
Robust brass housing, nickel-plating with fine thread M30 x 1.5 mm Cable or connector Enclosure rating IP 67 LED status indicator
0.5 (12)
1.5 (38)
2.4 (60)
LED
M30x1.5
2.0 (50)
2.4 (60)
M30x1.5
3.0 (76)
M30x1.5
3.0 (76)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
772
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Load current Continuous current Ia OFF state current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% 2.8 V at Ia max. 3 mA 100 mA 0.8 mA 50 ms 2% - 10% of sr 2% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 bis 55 Hz, 1 mm -13...158F (-25...70C) Brass nickel-plated, plastic 30 Nm PVC, 2 x 0.5 mm2
Installation in metal
Output function
Switching frequency f in Hz
200 200 200 200
Connection
Type
Part no.
Connection Diagram
bn bu
1 4
+ DC -
bn bu
1 2
+ DC 2
Contact 1 2/4
Assignment + V DC - V DC
773
3 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 30 Advanced
Inductive Proximity Sensors Highlights
Enhanced sensing range Shielded or unshielded PNP or NPN output Normally open/normally closed function High switching frequency
IM 30 Advanced Dimensional Drawing
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M30 x 1.5 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm) 36 LED
M30x1,5
0.5 (12)
1.5 (38)
2.4 (60)
LED
M30x1,5
2.0 (50)
2.4 (60)
M30x1,5
3.0 (76)
M30x1,5
3.0 (76)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
774
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% of Ub 1 V at Ia max. 10 mA 400 mA 100 ms 2% - 15% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 60 Nm PVC, 3 x 0.5 mm2
Installation in metal
Switching output
PNP NPN PNP PNP NPN PNP PNP NPN PNP PNP NPN PNP
Output function
Switching frequency f in Hz
150 150 150 150 150 150 150 150 150 150 150 150
Connection type
Type
Part no.
Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm Cable 2 m Cable 2 m Cable 2 m Connector M12 x 1 mm Connector M12 x 1 mm Connector M12 x 1 mm
IM30-15BPS-ZW1 IM30-15BNS-ZW1 IM30-15BPO-ZW1 IM30-15BPS-ZC1 IM30-15BNS-ZC1 IM30-15BPO-ZC1 IM30-20NPS-ZW1 IM30-20NNS-ZW1 IM30-20NPO-ZW1 IM30-20NPS-ZC1 IM30-20NNS-ZC1 IM30-20NPO-ZC1
7 900 141 7 900 142 7 900 143 7 900 145 7 900 146 7 900 147 7 900 153 7 900 154 7 900 155 7 900 157 7 900158 7 900 159
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu Wire color
1 2 3
bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Short circuit protection (pulsed) Robust brass housing, nickel-plated with fine thread M8 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator
dimensions in inches (mm)
Installation quasi flush or non-flush in metal Normally open function PNP or NPN output High switching frequency
Dimensional Drawing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
776
Electrical and Mechanical Data Operating voltage Ub Ripple Uss Voltage drop Ud (at Ia max.) Power consumption (without load) Continuous current Ia Time delay before availability Tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 20% of Ub 2 V at Ia max. 10 mA 200 mA 100 ms 1% - 5% of sr (5% typ.) 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, chrome-plated, plastic 60 Nm PVC, 3 x 0.34 mm2
Installation in metal
* *
Switching output
NPN PNP PNP
Output function
Switching frequency f in Hz
200 200 100
Connection type
Type
Part no.
* Installation notes quasi flush When mounting in conductible materials the sensors have to be installed with a distance A to the surface. A Steel, metal = 6 mm / A Stainless steel = 2 mm
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC 2
Contact 1 4 3
Assignment + V DC NO - V DC 4 3 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
777
IM 30 Universal
Inductive Proximity Sensors Highlights
Shielded or unshielded
AC
Robust brass housing, nickel-plated with fine thread M30 x 1.5 mm Enclosure rating IP 67 LED status indicator
IM 30 Universal
0.6 (15)
1.7 (44)
3.2 (81)
0.7 (18)
LED
M30x1.5
0.4 (9)
2.3 (59)
3.2 (81)
0.7 (18)
page 927
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
778
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Continuous current Ia Peak current Ik Min. load current Residual current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Protection class Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 2...250 V AC / DC 6.5 V AC / 6 V DC at Ia max. 350 mA AC (...+50C), 250 mA AC (...+80C), 100 mA DC 2.2 A (20ms/0.5 Hz) 5 mA 2.5 mA (250 V AC), 1.3 mA (110 V AC), 0.8 mA (24 V DC) approx. 8 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm 13...176F (-25...80C) Brass, nickel-plated, plastic 50 Nm PUR-PVC, 2 x 0.5 mm2
Installation in metal
Output function
Switching frequency f in Hz
25 (AC) / 30 (DC) 25 (AC) / 30 (DC) 25 (AC) / 30 (DC)
Connection
Type
Part no.
Connection Diagram
bn bu bn bu
Wire color bn bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IM 30 NAMUR
Inductive Proximity Sensors Highlights
Shielded High switching frequency Short circuit protection (pulsed) Solid stainless steel housing Cable
IM 30 NAMUR Dimensional Drawing
36
M30x1.5
0.6 (15)
1.6 (41)
0.1 (2)
M30x1.5
1.6 (41)
0.1 (2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
780
Electrical and Mechanical Data Operating voltage Ub Rated voltage Un Power consumption, attenuated Power Consumption, unattenuated Internal capacitance Internal inductance Cable resistance Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protected Reverse polarity protected Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Max. data for connecting isolating unit EN 2 EX or other approved isolating amplifier: Short circuit current Ik max No load voltage Uo Power loss Pmax 5...25 V DC 8.2 V DC 1.0 mA 2.2 mA 230 nF (flush) 240 nF (non-flush) 130 H (flush) 100 H (non-flush) 50 2 ms 1% - 10% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 50 Nm PUR-PVC, 3 x 0.055 mm2, blue
50 mA 15 V 180 mW
Switching output
NAMUR NAMUR
Output function
Switching frequency f in Hz
450 200
Connection type
Type
Part no.
Cable 2 m Cable 2 m
IM30-10B-N-ZW0 IM30-15N-N-ZW0
Connection Diagram
Assignment + V DC - V DC
781
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IH 03 Miniature
Inductive Proximity Sensors Highlights
Shielded PNP or NPN output Normally open function High switching frequency Short circuit protection (pulsed)
IH 03 Miniature Dimensional Drawing
Solid stainless steel housing Cable Enclosure rating IP 67 LED status indicator
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
782
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 10...30 V DC 20% of Ub 0.6 V max. at Ia max. 10 mA 100 mA 10 ms 10% of sr 2% 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Stainless steel, plastic PUR-PVC, 3 x 0.055 mm2
Installation in metal
Switching output
PNP NPN PNP
Output function
Switching frequency f in Hz
2000 2000 2000
Connection type
Type
Part no.
Connection Diagram
PNP
bn bk bu
NPN + DC -
bn bk bu
+ DC -
PNP
bn bk bu
Wire color bn bk bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IH 04 Miniature
Inductive Proximity Sensors Highlights
Shielded PNP or NPN output Normally open function High switching frequency Short circuit protection (pulsed)
IH 04 Miniature Dimensional Drawing
Solid stainless steel housing Cable or connector Enclosure rating IP 67 LED status indicator
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
784
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 10...30 V DC 20% of Ub 2.0 V max. at Ia max. 10 mA 200 mA 10 ms 10% of sr 1.5% 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Stainless steel, plastic PUR-PVC, 3 x 0.14 mm2
Installation in metal
Switching output
PNP NPN PNP NPN
Output function
Switching frequency f in Hz
5000 5000 5000 5000
Connection type
Type
Part no.
Connection Diagram
PNP
bn bk bu
1 4 3
+ DC -
NPN
bn bk bu Wire color
1 4 3
+ DC Contact Assignment 4 1 3
bn bk bu
1 4 3
+ V DC NO - V DC
785
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IH 06 Short
Inductive Proximity Sensors Highlights
Shielded PNP or NPN output Normally open function High switching frequency Short circuit protection (pulsed)
IH 06 Short Dimensional Drawing
Solid stainless steel housing Cable or connector Enclosure rating IP 67 LED status indicator
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
786
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable Selection Table Sensing range Sn in (mm)
0.6 (1.5) 0.6 (1.5) 0.6 (1.5) 0.6 (1.5) 0.6 (1.5) 0.6 (1.5)
10...30 V DC 20% of Ub 2.0 V max. at Ia max. 10 mA 200 mA 10 ms 10% of sr 5% 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Stainless steel, plastic PVC, 3 x 0.14 mm2
Installation in metal
Switching output
PNP NPN PNP PNP NPN PNP
Output function
Switching frequency f in Hz
5000 5000 5000 5000 5000 5000
Connection type
Type
Part no.
6 020 165 6 020 166 6 020 167 6 020 169 6 020 170 6 020 171
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 4 3
Wire color bn bk bu
4 1 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IH 06 Advanced
Inductive Proximity Sensors Highlights
Enhanced sensing range Shielded or unshielded PNP or NPN output High switching frequency Short circuit protection (pulsed)
IH 06 Advanced Dimensional Drawing
Solid stainless steel housing Cable or connector Enclosure rating IP 67 LED status indicator
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
788
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 10...30 V DC 10% of Ub 1.2 V at Ia max. 20 mA 200 mA 100 ms 2% - 15% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Stainless steel, plastic PVC, 3 x 0.14 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP NPN PNP
Output function
Switching frequency f in Hz
3000 3000 3000 3000 3000 3000 3000
Connection type
Type
Part no.
7 900 177 7 900 178 7 900 179 7 900 180 7 900181 7 900 182 7 900 183
Connection Diagram
PNP
bn bk bu
1 4 3
bn bk bu
1 4 3 4 1
+ DC -
Wire color bn bk bu
Assignment + V DC NO/NC - V DC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
789
IH 06 Advanced Short
Inductive Proximity Sensors Highlights
Enhanced sensing range Shielded or unshielded PNP or NPN output High switching frequency Short circuit protection (pulsed)
IH 06 Advanced Short Dimensional Drawing
Solid stainless steel housing Cable or connector Enclosure rating IP 67 LED status indicator
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
790
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 10...30 V DC 10% of Ub 1.2 V at Ia max. 10 mA 200 mA 5 ms 1% - 20% of sr 5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...160F (-25...70C) Stainless steel, plastic PVC, 3 x 0.14 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP PNP NPN PNP NPN PNP
Output function
Switching frequency f in Hz
3000 3000 3000 3000 3000 2500 2500 2500 2500 2500
Connection type
Type
Part no.
Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm Connector M8 x 1 mm
IH06-02BPS-VWK IH06-02BNS-VWK IH06-02BPS-VTK IH06-02BNS-VTK IH06-02BPO-VTK IH06-04NPS-VWK IH06-04NNS-VWK IH06-04NPS-VTK IH06-04NNS-VTK IH06-04NPO-VTK
6 025 874 6 025 874 6 025 874 6 025 874 6 025 874 6 025 874 6 025 874 6 025 874 6 025 874 6 025 874
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3
+ DC -
PNP
bn bk bu
1 4 3
Wire color bn bk bu
4 1 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IH 20 Universal
Inductive Proximity Sensors Highlights
Unshielded
AC
Broad operating voltage range in AC and DC Short circuit protection (pulsed) Plastic housing
Dimensional Drawing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
792
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ud (at Ia max.) Continuous current Ia Peak current Ik Min. load current Residual current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Protection class Shock and vibration stress Ambient temperature Ta Housing material Connection cable 20...250 V AC / DC 6.5 V AC / 6 V DC 350 mA AC (... 50C), 250 mA AC (...80C), 100 mA DC 2.2 A (20 ms / 0.5 Hz) 5 mA 2.5 mA (250 V AC), 1.3 mA (110 V AC), 0.8 mA (24 V DC) approx. 45 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...176F (-25...80C) Plastic PUR-PVC, 2 x 0.5 mm2
Installation in metal
Switching output
PNP
Output function
Switching frequency f in Hz
25 (AC) / 70 (DC)
Connection type
Type
Part no.
Cable 2 m
IH20-10NUS-KU0
7 902 130
Connection Diagram
bn bu
L1 / + AC/DC N/-
Assignment L1 / + N /-
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
793
IH 34 Universal
Inductive Proximity Sensors Highlights
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
794
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ud (at Ia max.) Continuous current Ia Peak current Ik Min. load current Residual current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Protection class Shock and vibration stress Ambient temperature Ta Housing material Connection cable 20...250 V AC / DC 6.5 V AC / 6 V DC 350 mA AC (... 50C), 250 mA AC (...80C), 100 mA DC 2.2 A (20 ms / 0.5 Hz) 5 mA 2.5 mA (250 V AC), 1.3 mA (110 V AC), 0.8 mA (24 V DC) approx. 8 / 50 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...176F (-25...80C) Plastic PUR-PVC, 2 x 0.5 mm2
Installation in metal
Output function
Switching frequency f in Hz
7 7
Connection type
Type
Part no.
Cable 2 m Cable 2 m
IH34-30NUS-KU0 IH34-30NUO-KU0
Connection Diagram
bn bu
L1 / + AC/DC N/-
bn bu
Wire color bn bu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IQ 05 Miniature
Inductive Proximity Sensors Highlights
Shielded PNP or NPN output Normally open function High switching frequency Short circuit protection (pulsed)
IQ 05 Miniature Dimensional Drawing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
796
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 10...30 V DC 20% of Ub 2.0 V max. at Ia = 200 mA 10 mA 200 mA 10 ms 10% of sr 1.5% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated,plastic PUR, 3 x 0.055 mm2
Installation in metal
Switching output
PNP NPN PNP NPN
Output function
Switching frequency f in Hz
5000 5000 5000 5000
Connection type
Type
Part no.
Connection Diagram
PNP
bn bk bu
PNP + DC NPN + DC -
bn bk bu
+ DC -
NPN
bn bk bu
bn bk bu
+ DC -
Assignment + V DC NO - V DC
797
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IQ 08 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded PNP or NPN output High switching frequency Short circuit protection (pulsed) Small plastic housing
IQ 08 Advanced Dimensional Drawing
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
798
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 10...30 V DC 10% of Ub 1.5 V at Ia max. 10 mA 300 mA 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Plastic PVC, 3 x 0.25 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP PNP
Output function
Switching frequency f in Hz
5000 5000 5000 5000 5000 5000
Connection type
Type
Part no.
7 900 195 7 900 196 7 900 197 7 900 198 7 900 199 7 900 201
Connection Diagram
PNP
bn bk bu
1 4 3
+ DC -
NPN
bn bk bu Wire color
1 4 3
+ DC Contact Assignment 4 1 3
bn bk bu
1 4 3
+ V DC NO - V DC
799
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IQ 10 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded PNP or NPN output High switching frequency Short circuit protection (pulsed) Plastic housing
IQ 10 Advanced Dimensional Drawing
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
800
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 10...30 V DC 10% of Ub 1.5 V at Ia max. 10 mA 300 mA 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Plastic PVC, 3 x 0.25 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP NPN PNP NPN
Output function
Switching frequency f in Hz
3000 3000 3000 3000 3000 3000 3000 3000
Connection type
Type
Part no.
7 900 203 7 900 204 7 900 205 7 900 206 7 900 207 7 900 208 7 900 209 7 900 210
Connection Diagram
PNP
bn bk bu
1 4 3
NPN + DC -
bn bk bu
1 4 3 4 1
+ DC -
Contact 1 4 3
Assignment + V DC NO - V DC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
801
IQ 12 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded PNP or NPN output High switching frequency Short circuit protection (pulsed) Plastic housing
IQ 12 Advanced Dimensional Drawing
page 908
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
802
Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable 6...30 V DC 10% of Ub 1.5 V at Ia max. 5 mA 300 mA 10 ms 1% - 15% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Plastic PVC, 3 x 0.25 mm2
Installation in metal
Switching output
PNP NPN PNP NPN PNP PNP
Output function
Switching frequency f in Hz
3000 3000 3000 3000 1000 1000
Connection type
Type
Part no.
1 016 275 1 016 299 1 016 276 1 016 461 1 016 463 1 016 467
Connection Diagram
PNP
bn bk bu
1 4 3
+ DC -
NPN
bn bk bu Wire color
1 4 3
+ DC Contact Assignment 4 1 3
bn bk bu
1 4 3
+ V DC NO - V DC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
803
IQ 40 Short
Inductive Proximity Sensors Highlights
Shielded or unshielded User-selectable sensing position, adjusts to any of 5 sensing directions PNP output NO and complementary output function
IQ 40 Short Dimensional Drawing
Short circuit protection (pulsed) Plastic housing Connector Enclosure rating IP 67 LED status indicator and LED function indicator
dimensions in inches (mm)
page 909
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
804
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Protection class Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Selection Table Sensing Installation range Sn in metal in (mm) 10...36 V DC 2.5 V at Ia max. and Ub 24 V 15 mA 250 mA approx. 4 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Plastic
Switching output
Output function
Switching frequency f in Hz
Connection type
Type
Part no.
0.6 (15)
PNP
200
Connector M12 x 1 mm
IQ40-15BPS-KC0
7 900 223
0.8 (20)
PNP programmable
300
Connector M12 x 1 mm
IQ40-20BPP-KCK
6 012 014
1.4 (35)
PNP
100
Connector M12 x 1 mm
IQ40-35NPS-KC0
7 900 224
1.4 (35)
PNP programmable
100
Connector M12 x 1 mm
IQ40-35NPP-KCK
6 012 015
Connection Diagram
PNP
+ DC -
Contact 1 4 3 2
Assignment + V DC NO - V DC free 3
2 1 4
4 4 3 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IQ 40 Standard
Inductive Proximity Sensors Highlights
Shielded or unshielded User-selectable sensing position, adjusts to any of 5 sensing directions PNP output Programmable NO/NC function
IQ 40 Advanced Dimensional Drawing
Short circuit protection (pulsed) Plastic housing Terminal connection Enclosure rating IP 65 LED status indicator
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
806
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Protection class Shock and vibration stress Ambient temperature Ta Housing material Selection Table Sensing range Sn in (mm) Installation in metal Switching output Output function Switching frequency f in Hz Connection type Type Part no. 10...36 V DC 2.5 V at Ia max. and Ub 24 V 15 mA 250 mA approx. 4 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 65 30 g, 11 ms, 10 to 55 Hz, 1 mm 13...176F (-25...80C) Plastic
0.6 (15)
PNP programmable
300
IQ40-15BPP-KK0
7 900 219
0.8 (20)
PNP programmable
300
IQ40-20NPP-KK0
7 900 221
Connection Diagram
PNP 1/3 X 2/4 progr. Programming with wirelinks Link closed: NO Link open: NC Terminal 1/3 X 2/4 Assignment + V DC NO/NC - V DC
807
+ DC -
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IQ 40 Universal
Inductive Proximity Sensors Highlights
Shielded or unshielded
AC
User-selectable sensing position, adjusts to any of 5 sensing directions Broad operating voltage range in AC and DC
Programmable switching output: NO or NC Plastic housing Enclosure rating IP 65 Terminal connection LED status indicator
IQ 40 Universal
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
808
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Continuous current Ia Peak current Ik Min. load current Residual current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Protection class Shock and vibration stress Ambient temperature Ta Housing material Selection Table Sensing range Sn in (mm) Installation in metal Output function Switching frequency f in Hz Connection Type Part no. 20...250 V AC / DC 6.5 V AC / 6 V DC with Ia max. 350 mA AC (...+50C), 250 mA AC (...+80C), 100 mA DC 2.2 A (20 ms / 0.5 Hz) 5 mA 2.5 mA (250 V AC), 1.3 mA (110 V AC), 0.8 mA (24 V DC) approx. 8 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes IP 65 30 g, 11 ms, 10 to 55 Hz, 1 mm 13...176F (-25...80C) Plastic
20 (AC) / 55 (DC)
Terminal up to 2.5mm2
IQ40-15BUP-KK0
7 902 136
20 (AC) / 55 (DC)
Terminal up to 2.5mm2
IQ40-20NUP-KK0
7 902 137
Connection Diagram
1/3 2/4 progr. Programming with wire links Link closed: NO Link open: NC Terminal Assignment 1/3 2/4 L1 / + N/ -
L1 / + AC/DC N/-
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
809
IQ 80 Standard
Inductive Proximity Sensors Highlights
Unshielded Adjustable sensing distance from 20 to 60 mm PNP output Programmable NO/NC function
IQ 80 Advanced Dimensional Drawing
Short circuit protection (pulsed) Robust plastic housing Terminal connection Enclosure rating IP 65 LED status indicator
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
810
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Protection class Shock and vibration stress Ambient temperature Ta Housing material Selection Table Sensing range Sn in (mm) Installation in metal Switching output Output function Switching frequency f in Hz Connection type Type Part no. 10...36 V DC 2.5 V at Ia max. and Ub 24 V 15 mA 250 mA approx. 250 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes IP 65 30 g, 11 ms, 10 to 55 Hz, 1 mm 13...176F (-25...80C) Plastic
2.4 (60)
PNP programmable
IQ80-60NPP-KK0
7 900 227
Connection Diagram
PNP
1 2 3 4 5 NO
+ DC -
+ DC NC
progr.
Terminal 1 2 3 4 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IQ 80 Universal
Inductive Proximity Sensors Highlights
Unshielded Adjustable sensing distance from 20 to 60 mm Broad operating voltage range in AC and DC Robust plastic housing
IQ 80 Universal Dimensional Drawing
Programmable switching output: NO or NC Enclosure rating IP 65 Terminal connection LED status indicator
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
812
Electrical and Mechanical Data Operating voltage Ub Voltage drop Ub Continuous current Ia Peak current Ik Min. load current Residual current Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Protection class Shock and vibration stress Ambient temperature Ta Housing material Selection Table Sensing range Sn in (mm) Installation in metal Output function Switching frequency f in Hz Connection Type Part no. 20...250 V AC / DC 6.5 V AC / 6 V DC with Ia max. 350 mA AC (...+50C), 250 mA AC (...+80C), 100 mA DC 2.2 A (20 ms / 0.5 Hz) 5 mA 2.5 mA (250 V AC), 1 mA (24 V DC) approx. 8 ms 1% - 15% of sr 10% of sr 10% of sr to EN 60 947-5-2 Yes IP 65 30 g, 11 ms, 10 to 55 Hz, 1 mm 13...176F (-25...80C) Plastic
IQ80-60NUP-KK0
7 902 138
Connection Diagram
progr.
1 2 3 4 5 NO
N/+ AC/DC L1 / -
N/+ AC/DC L1 / NC
Terminal 1 2 3 4 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com