Background
`
SCV ORV Shell and Tubes Direct Contact Ambient AAV = Natural Draft FAV = Fan Assisted Intermediate Fluids with Fin Fans Heating Towers [reverse cooling towers]
Decision Drivers
Soft Issues
Operational Flexibility Load Following Follo ing Restart time and costs Reliability Ease of Operation Effectiveness Ambient Temperature Limits to Operation Trim Heat Required to Reach Pipeline Temperature Efficiency Turndown Range
Hidden Costs
Water Intake / Outfall Systems Screens and Filters Water Quality and Treatments Algaecides / Bacterial Treatments Suspended Solids Corrosion Intermediate fluids Cost Hazards Chemicals C e ca s Neutralizing Hypochlorites Environmental Compliance
Overall Efficiencies
Basis = 1 BCFD about 600,000,000 btu / hr Efficiency = 600 MM / total energy used SCV at 98% fuel efficient 98% =600,000,000 / 612,248,900 Power required = 2400 kW = 8,195,000 btu / hr Final Fi l = 600 MM / 612 + 8 8.2 2 MM = 96 96.7% 7% AAV using 0 power and 0 fuel = infinite% Heat drawn from ambient heat sink 600,000,000 btu / 0 = infinite
Mechanical Advantage
`
Gained b by using sing Pumps for using free seawater heat sink Fans for using free free ambient air heat sink Outcomes are surprising Apparent efficiencies exceed 100% Only within confines of closed system with x Free energy in water x Free energy in air
Trim Heat eat Required equ ed for o Competing Co pet g Ambient LNG Vaporizer Technologies
P e rc e n t T rim H e a t R e q u ire d v s A m b ie n t T e m p e ra tu re
120 40 100 % T r im H e a t R e q u ir e d 80 60 40 20 0 0 20 40 60 Am b ie n t T e m p e r a tu r e (F ) 80 65 68 70 45 54
ORV Shell & Tube FAV AAV IFV-Mustang IFV Mustang IFV-Dahej RCT