Sei sulla pagina 1di 1

Samsung Fiberoptics products

OUTDOOR CABLE
OP22 | OP31 | OP32

OPGW - OPtical Ground Wire


Stranded Tube / Central Tube
Description
SAMSUNG OPGW provides ground wire protection for overhead power lines as well as fiber optic cable for telecommunication network with high performance. By combining these functions in one cable, OPGW considerably reduces loads on the towers and is optimized for superior mechanical, electrical, and data transmission properties to fulfill all overhead line design requirements.
Outer layer Breaking load mm KN 10-6/K Ohm/km

Mechanical Performance

Temperature : - Operation/Storage : -40 ~ +70 C C - Installation : -20 ~ +70


OP22 Characteristics Unit Number of tubes * Fibers/tube Nominal outer diameter Nominal cable weight Metallic section Inner layer mm kg/km mm 2 mm 24 1 * 24 13.98 465 111 Central
2.75 2.82

Fiber Count 36 1 * 36 17.04 687 166 48 1 * 48 18.32 793 191 72 2 * 36 17.04 649 157

* AS,

Central
3.35

3.44

* AS,

Central
3.60

3.7

* AS,

Central
3.35

3.7

* AS,

2.83

* (1ST + 5AS) * 12AW


51 18 0.33 100

3.45

* (1ST + 5AS) * 12AW


76 18 0.22 220

3.71

* (1ST + 5AS) * 12AW


88 18 0.19 300

3.45

* (1ST + 5AS) * 12AW


66 18 0.23 200

Feature / Benefit
Up to 144 fibers (OP22), 48 fibers (OP31, OP32) Laser welded, hermetically sealed stainless steel tubes provide mechanical and thermal protection for optical fiber High tensile load, long span, high crush resistance Excellent resistance to moisture and hydrogen ingress handling Fiber bundles for more than 12 fibers to quick and easy identification Minimized additional loads due to small diameter and lightweight with the high strength aramid yarns
OPGW - Optical Ground Wire OP22

Thermal coefficient D.C. resistance/20 C

Short circuit current, 40~200 C KA 2.S Minimum bending radius - Short term [Loaded] : 15*OD - Long term [Installed]: 10*OD mm mm

280 210

340 255

366 275

340 255

OP31 | OP32 Characteristics Unit Protective Layer Nominal outer diameter Nominal cable weight Metallic section Central tube inner layer Outer layer Breaking load mm kg/km mm 2 mm mm KN 10 /K
-6

Fiber Count 2 ~ 48 Single (OP31) 10.6 411 58 Central


3.6

2 ~ 48 Dual (OP32) 17.82 650 145

Anti-rotational devices usually not required for installation Custom cable designs available Meets or exceeds test criteria specified in IEEE 1138, the recognized standard for OPGW

* 1ST

Central

3.6

3.5

* 6AS

* 1ST, 3.5* 6AS 3.61* 12AW


17 0.3 2700

69 13 1.5 2700

78

Cable Drawing

Thermal coefficient D.C. resistance/20 C

Ohm/km Short circuit current, 40~200 C KA 2.S Minimum bending radius - Short term [Loaded] : 15*OD mm mm

212 159

357 267

Colored optical fiber Fiber bundle Gel-filled stainless Steel Tube(ST) Aluminum clad Steel wire(AS) Aluminum Wire(AW)

- Long term [Installed]: 10*OD


* Tested in accordance with IEC 60794-1

Note Ordering

Fiber and binder colors by IEC60304: Blue/Orange/Green/Brown/Grey/White/Red/Black/Yellow/Violet/Pink/Aqua

OP22: Stranded tube

OP32: Central tube(dual layer)

-2 OP22 - 1 OP31 1 Fiber count 002~144 OP32 2


Fiber type

S Single mode: Max. 0.38/0.25 dB/km @1310/1550 nm U NZ-DSF: Max. 0.25 dB/km @1550 nm

* Drawings are not to scale