Sei sulla pagina 1di 32

HEAT TRANSFER

Introduction
Upon completion of this course, the student will be able to: 1. 2. 3. 4. 5. 6. 7. Identify and explain the three types of heat transfer and the laws associated with the three modes of heat transfer Define thermal conductivity and thermal resistance Calculate the rate transfer by conduction both for plane and cylindrical systems Explain the overall heat transfer coefficient Calculate rates of heat transfer using the overall heat transfer coefficient for plane and cylindrical systems Describe the different types of heat exchangers commonly used in the industry Describe the operation of heat exchangers and evaluate related variables associated with heat exchanger operation (LMTD, CMTD, heat transfer coefficients, and sizing) Calculate heat transfer rates in heat exchangers.

8.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 2 of 33

UNIT 1

HEAT TRANSFER
Introduction
Heat transfer and the different laws governing heat transmission are very important in the design and operation of equipment like steam generators, furnaces, pre-heaters, heat exchangers, coolers, evaporators and condensers in different industries. The primary objectives of any heat transfer operation are: 1. 2. 3. To obtain the maximum heat transfer rate per unit surface compatible with economic factors Recovery of heat as in heat exchangers, recuperators, and regenerators Minimizing heat losses by use of insulation

In a given operation, all three objectives may be important.

LESSON 1 Modes of heat transfer


1.1 Conduction

Conduction is the transfer of heat from one part of a substance to another under the influence of a temperature gradient, without appreciable displacement of the molecules of that substance. It is the transfer of energy from one molecule to an adjacent molecule. Conduction is the only mechanism of heat flow in an opaque solid. With transparent solids (e.g. glass), some energy is transmitted by radiation as well as by conduction. With gases and liquids, conduction may be supplemented by convection and radiation. With flowing fluids, heat is transferred by conduction at right angles to the direction of flow. Examples of conduction are: heat transfer through walls, pipes, freezing of the ground in winter, etc. 1.2 Convection

Convection involves the transfer of heat by the molecules of a substance moving from one place to another and by mixing with each other. This mode of heat transfer involves primarily fluids (liquids and gases).

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 3 of 33

The motion of the fluid may be due to density difference resulting from temperature differences (natural convection), or the motion may be produced by mechanical means, as in forced convection. During heat transfer by convection, energy is also transferred simultaneously by molecular conduction, and, in transparent media, by radiation. Examples of heat transfer by convection are: cooling or heating of fluids in heat exchangers, cooling of a cup of coffee by blowing over the surface, baking a cake in a gas oven, etc. 1.3 Radiation

In contrast to the mechanisms of conduction and convection, where energy transfer through a material medium is involved, heat may also be transferred through a vacuum. This mode of heat transfer is electromagnetic radiation. A hot body emits radiant energy in all directions. When this energy strikes another body, part of it may be reflected, part may be transmitted through the body, and the remainder is absorbed and quantitatively transformed into heat. Examples of radiation are: transfer of heat from the sun to the earth, heating of tubes in a furnace, etc.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 4 of 33

LESSON 2

Laws of Heat Transfer


2.1 Conduction Heat Transfer

When a temperature gradient exists in a body, there is an energy transfer from the high temperature region to the low temperature region this is heat transfer by conduction. Heat transfer by conduction is governed by Fouriers Law, which for one-dimensional cases is given as: q In the above equation, q A k = the heat transfer rate in watts = -k A dT/dx (1)

= the area involved in the heat transfer = thermal conductivity of the material (values of k for different materials can be found in the data book).

dT/dx = the temperature gradient in the direction of heat flow

The negative sign in the equation is due to the fact that heat flows downhill on a temperature scale. K has the units of watts per meter per 0C where heat flow is expressed in watts. Equation (1) is known as the Fouriers Law of Heat Conduction 2.2 Convection Heat Transfer

When a heated solid is placed in air, heat is carried away from the solid surface. Close to the surface of the solid, heat is lost by conduction, but as the distance increases from the surface, heat transfer is by a convection process. To express the overall effect of convection, the following equation is used: q = hA (Tw - T) (2)

In the above equation, Tw and T are the temperatures at the wall and in the free stream respectively. A is the area of heat flow. The above equation is also known as Newtons law of cooling. The quantity h is called the convective heat transfer coefficient. This is also sometimes called the film conductance because of its relationship to the conduction process in the thin stationary layer of fluid at the solid surface. Units of h: watts per square meter per 0C, when heat flow (q) is in watts.
Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 5 of 33

2.3

Radiation Heat Transfer

In the radiation mode, heat transfer takes place by electromagnetic radiation (when there is a temperature difference). A black body (called an ideal radiator) emits energy at a rate proportional to the fourth power of the absolute temperature of the body. When two bodies exchange heat by radiation, the net heat exchange is then proportional to the difference in T4 q = (T14 - T24) The symbol is called the Stefan Boltzmann constant 5.669 x 10-8 w/(m2 K4). and (3) has a value of

Equation (3) is called the Stefan Boltzmanns law of thermal radiation and is applicable only to black bodies. For other surfaces, the emisivity factor (F) and the geometric shape factor (Fg) has to be added to the equation: q = F Fg (T14 - T24) (4)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 6 of 33

LESSON 3 Steady State Conduction 3.1 Conduction in a plane surface: If conduction heat transfer takes place at steady conditions through a plane surface (plane wall), equation 1 can be written as: q kA =- ------- (T2 T1) x (5)

This may be shown diagrammatically: x

q q

T1

T2( T1 T2)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 7 of 33

If more than one material is present, as in a multi-layered wall, the heat flow equation becomes: T1 - T4 q = -----------------------------------------xA/(kA A) + xB/(kB A) + xC/(kC A)

XA XB XC

1 Electrical Analogy: Equation (5) can be written as:

Thermal Potential Difference Heat Flow Rate = --------------------------------------Thermal Resistance The above is analogous to Ohms Law in Electric circuit theory. The heat transfer rate is the flow; and the combination of thermal conductivity, thickness of the material, and the area represents the resistance to this flow; the temperature is the potential, or driving force for heat flow. The heat conduction can then be represented as an electric analogy: T1 O RA T2 O RB xB/(kB A) T3 O xC/(kC A) RC T4 O

xA/(kA A)

where RA , RB , and RC represents the three resistances in series.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 8 of 33

3.2

Radial Systems (cylinders)

When heat is flowing through the sides of a cylindrical body of circular cross section (e.g. a pipe) the direction of heat flow is at all points radial and perpendicular to the axis; the cross section of the path of heat transfer is proportional to the distance from the center of the cylinder. In these cases, it will be shown below that the logarithmic-mean area is the proper average value.

L Inner Radius =ri Outer Radius =ro Length =L

Inner wall temperature = Ti ; Outer wall temperature = To Fouriers Law for heat conduction for radial systems can be written as: qr = -k Ar dT/dr (6)

The area for heat flow in the radial path is given as: Ar = 2rL Substituting the expression for Ar, equation (6) becomes qr = -2rL k dT/dr (7)

Noting that at r = ri , T = Ti and that at r = ro , T = To , equation (7) can be integrated (with q constant): 2kL (Ti To) q = ------------------------ln(ro/ri) Equation (8) is the expression for heat transfer through a cylinder. resistance (Rth) in this case is: Rth ln(ro/ri) = ------------2kL (8) The thermal

(9)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 9 of 33

For a multi-layered cylindrical wall (e.g. for a pipe with several layers of insulation), the expression for heat transfer becomes: 2L (T1 T4) q = ---------------------------------------------ln(r2/r1)/kA + ln(r3/r2)/kB + ln(r4/r3)/kC (10)

The electrical analogy will be represented as: T1 O RA T2 O RB ln(r3/r2)/2kBL T3 O RC ln(r4/r3)/2kCL T4 O

ln(r2/r1)/2kAL

Example Problems (Steady State Conduction) Example 1 A composite three-layered wall is formed of a 0.5 cm thick aluminum plate, a 0.25 thick layer of sheet asbestos, and a 2.0 cm thick layer of rock wool; the asbestos is the central layer. The outer aluminum surface is at 500oC and the outer rock wool surface is at 50oC. Determine the heat flow per unit area.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 10 of 33

The thermal conductivities of the three materials are: kal = 268.08 W/(m oK) ; kasb = 0.166 W/(m oK); krw = 0.0548 W/(m oK) Solution: The heat flow per unit area can be written as: T1 - T4 q/A = ---------------------------------x1/k1 + x2/k2 + x3/k3 )

q 500C q A1 ASb Rw 50C

0.5

0.25

2.0

(500 - 50) oC q/A = ----------------------------------------------------------(0.5x 10-2)m (0.25x 10-2)m (2.0 x 10-2)m ---------------------- + --------------------- + ---------------------268.08 W/(m oK) 0.1660 W/(m oK) 0.0548 W/(m oK) = 1184.08 W/m2 (answer)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 11 of 33

Example 2 A 8 cm outer diameter (o.d.) steel pipe is covered with a 5 cm layer of asbestos, that is covered in turn with a 5.0 cm layer of glass wool. Determine: (a) the steady state heat transfer rate per linear meter of pipe, and (b) the interfacial temperature between the asbestos and the glass wool if the pipe outer surface temperature is 250 0C and the glass wool outer temperature is 40 0 C.Given: kasb = 0.2 W/(m oK) and kgw = 0.055 W/(m oK) Solution: Since this is an example of a radial system, the equation heat flux can be written as: 2L (T1 T3) q = ----------------------------------ln(r2/r1)/kAsb + ln(r3/r2)/kgw The heat transfer rate per linear foot is q/A. Thus the above equation can be written as: q/L = 2 (250 40) ------------------------------------------ln(5.5/4.0)/0.2 + ln(10.5/5.5)/0.055 = 98.84 W/m (answer, a)

1319 = ------------------------1.592+ 11.757

Since the heat transfer rate per linear foot (98.84 W/m) is known, the equation can be written for a single layer (the glass wool layer): 2 (T2 T3) 2 (T2 40) 2 (T2 40) q/L = ---------------- = -------------------- = --------------------ln(r3/r2)/kgw ln(10.5/5.5)/0.055 11.757

(q/L) 11.757 (T2 40) = ---------------2 T2 = 225 0C (answer, b)

= 184.95

Note: We could also have chosen the asbestos layer to find T2 since q/L is the same.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 12 of 33

LESSON 4
Overall Heat Transfer Coefficient In industrial processes, heat transfer usually takes place by a combination of conduction and convection mechanisms. In these circumstances, the overall heat transfer rate is to be determined. The convective heat transfer coefficient (h) in equation 2 (Newtons law of cooling) is then replaced with U (the overall heat transfer coefficient). Thus equation 2 becomes: q = U * A * (T)overall Where (T)overall is the overall temperature difference A U is the area through which heat flows, and is the overall heat transfer coefficient (11)

The units of U are the same as the units of h i.e W/(m2 0C) a) Plane Wall

Let us take a plane wall as shown in the diagram below, made up of a homogeneous material with a thermal conductivity k. One side of the wall is exposed to a fluid A at temperature TA, and the other side to fluid B at temperature TB (TA > TB). The thickness of the wall is x. The wall temperatures on the two sides of the wall are T1 and T2 (T1 > T2). X Fluid A TA hB K T1 T2 TB Fluid B

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 13 of 33

If we apply Newtons law of cooling at the two surfaces this gives the heat transferred per unit area: q/A = hA (TA - T1) = hB (T2 - TB) The equality holds because the heat transferred from one side of the wall is equal to the heat transferred to the other side. Rearranging the equation, (TA - T1) (T2 - TB) q = ----------- = -----------1/(hA A) 1/(hB A) The terms 1/(hA A) and 1/(hB A) are thermal resistances due to the convective boundary layer at the two surfaces of the wall.Hence the electrical analogy to this may be represented by three resistances in series (Figure below), the conductive resistance being x/kA from the conductive heat transfer equation (Equation 5). q TA O 1/(h1 A) T1 O T2 O x/(k A) 1/(h2 A) TB O

The heat transfer rate through each layer of resistance of a plane wall is: (TA - T1) (T1 - T2) q = ----------- = ------------ = 1/(hA A) x/(k A) (T2 - TB) -----------1/(hB A)

The conductive heat flow is exactly equal to convective heat flow on either side of the plane wall. On combining the equations to find the heat transfer per unit area: T1 - T2 q/A = ------------------------------1/hA + x / k + 1/hB Thus the overall heat transfer coefficient (U) for a plane wall becomes: 1 W U = ------------------------------- (13) having units of -----------1/hA + x / k + 1/hB m2 * 0 K (12)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 14 of 33

b)

Radial Systems:

To T2 ri Ti ro T1 q Ti O Ri T1 O Ra T2 O Ro To

Let us consider the cylindrical system (e.g. pipe) shown above: Ti and To are the temperature of the fluids flowing on the inner and outer sides of the system and ri and ro are the inner and outer radii; T1 and T2 are the surface temperatures as shown. Heat flow through the system can be represented as: (T)overall q = ---------------- Rthermal In the above equation, Ri Ra = inner convective thermal resistance = 1/(hiAi) = 1/ (2riLhi) ln (r2/r1) = conductive thermal resistance = ------------2ka L Ti - To = -------------------Ri + R a + Ro

Ro = outer convective thermal resistance = 1/(hoAo) = 1/ (2roLho) L = the length of the cylindrical system (pipe) Similar to the analysis of the plane wall, the heat transfer rate through each layer of resistance of the cylindrical system can be shown as: Ti - T1 T1 - T2 q = ----------- = -------------------------1/(hiAi) ln(r2/r1) /(2kaL) T2 - To = -------------1/(hoAo)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 15 of 33

This is because the heat flow through each resistance layer is exactly the same. Thus we can write the equation of the heat transfer through the system as: Ti - To q = -------------------------------------------------------------1/ (2riLhi) + ln(r2/r1) /(2kaL) + 1/ (2roLho) (14)

The overall heat transfer coefficient for a cylindrical system is based on either the inner surface area (Ai) or the outer surface area (Ao) of the cylinder (or pipe). Therefore, we can write : Ti - To q = Ui Ai (Ti - To) = Uo Ao (Ti - To) = -----------R 1 Uo = -------------------------------r2 r2 ln (r2/r1) 1 ----- + ---------------- + -----r1hi ka ho 1 Ui = -------------------------------1 r1 ln (r2/r1) r1 ----- + ---------------- + -----hi ka r2 ho (15)

(16)

Uo and Ui are the overall heat transfer coefficients based on the outer and inner surface areas respectively.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 16 of 33

Example problems (Overall Heat Transfer Coefficient) Example 3 A rectangular steel tank is filled with a liquid at 700C and exposed along the outside to air at 200C. The inner and outer heat transfer coefficients are hi = 23 W/(m2 K) and ho = 8 W/(m2 K). The tank wall is 1 cm. Thick mild steel with thermal conductivity k = 45 W/(m*K) and this is covered with a 3 cm. Layer of glass wool insulation ( k = 0.04 W/m*K). Determine: (a) the overall heat transfer coefficient and (b) the heat transfer rate per square meter area. Solution: Write the expression for the overall heat transfer coefficient for plane surfaces with two conductive layers: 1 U = ----------------------------------------1/hi +x1/k1 + x1/k1 + 1/hi 1 U = ----------------------------------------------------1/23 + (1x10-2)/45 + (3x 10-2)/0.04 + 1/8 1 U = --------------------------------------------+ 0.00022 + 0.75 + 0.125 = 1/0.9187 = 1.08 W/(m2 K) (answer a) (Note that the thermal resistance of the steel wall is negligible and that of the glass wool is predominant) The heat transfer rate per square meter: Q/A = U * T = (1.08)(70 - 20) = 54 W/ m2 (answer b)

or

or

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 17 of 33

Example 4 Water at 980C flows through a 2 inch schedule 40 horizontal steel pipe (k = 54 W/(m 0 C) and is exposed to atmospheric air at 200c.Calculate the overall heat transfer coefficient for this situation, based on the outer area of the pipe. The inner and outer convective heat transfer coefficients are: hi = 1961 W/(m2 0C) and ho = 7.91 W/(m2 0C). Given: the I.D. and O.D. of the pipe are 0.0525 m and 0.06033m respectively. Solution: Write the expression for the overall heat transfer coefficient for a radial system based on the outer surface area: 1 Uo = ----------------------------------r2 r2 ln (r2/r1) 1 ----- + ---------------- + -----r1hi ka ho 1 Uo = ----------------------------------------------------------------------0.06033 0.06033 ln (0.06033/0.0525) 1 ---------------- + ------------------------------------ + -----------(0.0525)(1961) 54 7.91 1 1 Uo = ------------------------------------------- = ---------------0.00059 + 0.00021 + 0.1264 0.1272 Uo = 7.86 W/ (m2 * 0C) (answer)

(note: the overall heat transfer coefficient is controlled by ho ).

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 18 of 33

UNIT 2

HEAT EXCHANGERS

There are many different types of industrial heat exchange equipment (heat exchangers). However, the one characteristic common to most heat exchangers is the transfer of heat from a hot fluid to a cold fluid with the two fluids being separated by a solid boundary. The proper operation and maintenance of heat exchangers is crucial to the efficient operation of any process plant.

LESSON 1

Types of Heat Exchangers:

1.

Double Pipe Heat Exchanger

This is the simplest type of heat exchanger and is essentially two concentric pipes with one fluid flowing through the center pipe while the other fluid flows co-currently or counter-currently in the annular space.The following figure shows a diagram of a double pipe exchanger with counter-flow arrangement.

2.

Shell and Tube Heat Exchanger

When the heat required transfer surface is large, the recommended type of heat exchanger is the Shell and Tube variety. In this type of cooler or heater, large heat transfer surface can be achieved economically and practically by placing tubes in a bundle; the ends of the tubes are mounted in a tube sheet. The tube bundle is then enclosed in a cylindrical casing (the shell) through which one fluid flows around and through the tube bundle. Fluid flowing through the tubes enters a header or channel where it is distributed through the tubes in parallel flow and leaves the unit through another header. Either the hot or the cold fluid may flow in the shell of the exchanger surrounding the tubes. Parallel flow through all tubes at a low velocity produces low heat transfer rates. For higher rates of heat transfer, multi-pass operation may be used. In multi-pass operation, the fluid in the tubes is diverted by baffles within the distribution header. Higher velocity and thus higher heat transfer rates are thus achieved.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 19 of 33

Baffles on the shell side divert the flow of the shell fluid into a path predominantly across the tubes of the exchanger. This increases turbulence and enhances heat transfer rates. Baffles in the shell are mostly semi-circular discs of sheet metal accommodating the tubes.

Flow in a double pipe heat exchanger (counter current)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 20 of 33

Cold fluid in

hot fluid out

Hot fluid in (a) Cold fluid in hot fluid in

cold fluid out

Cold fluid out

hot fluid out (b)

Shell and tube heat exchangers: (a) 1 shell pass and 1 tube pass (1-1 exchanger). (b) 1 shell pass and 2 tube passes (1-2 exchanger)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 21 of 33

LESSON 2

Types of Flow in Heat Exchangers


2.1 Co-current Flow

Both fluids flow in the same direction T1 T1 t1 t2 T2 T2 t2 t1 T2 T1

t1 Length of exchanger 2.2 Counter-current Flow One fluid flows in the opposite direction of the other T1 T2 t1 T1 t2 t2 T2

T2 T1 t1

Length of exchanger

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 22 of 33

LESSON 3

Determination of Heat Transfer for Heat Exchangers


The rate of heat transfer for heat exchangers is given by the following three equations: i) Heat lost by the hot fluid: q = mh * Cp * Th ii) Heat gained by the cold fluid: q = = mc * Cp * Tc iii) Heat transferred between the fluids: q = U * A * TLM (19) (18) (17)

The q for each equation is equal as the heat lost by the hot fluid is equal to the heat gained by the cold fluid and is also equal to the heat transferred between the two fluids.

In the above equations, mh and mc are the mass flow rate of the hot and cold fluids Cp is the specific heat Th = the temperature difference of the hot fluid as it enters and leaves the exchanger Tc = the temperature difference of the cold fluid as it enters and leaves the exchanger U = the overall heat transfer coefficient, and

A = the surface area of the exchanger TLM = the Log Mean Temperature Difference (LMTD) or the logarithmic average difference between the two streams and given by: ( T2 - T1) TLM = ----------------------ln (T2 /T1 ) (20)

where T2 and T1 are the temperature differences between the two fluids at each end of the exchanger. These temperature differences are also called the terminal temperature differences.
Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 23 of 33

Usually T2 is the higher of the two and is also referred to as GTTD (Greatest Terminal Temperature Difference). T1 is then referred to as LTTD (Least Terminal Temperature Difference). It is important to have a consistent basis for the overall heat transfer coefficient and the area. In most cases the outside surface area is used . Thus : q = Uo * Ao * TLM (21)

The above equation applies for exchangers with pure counter current flow. However, in most commercial heat exchangers of the shell and tube type (with more than one tube pass), the flow of fluids is neither co-current nor counter-current. The flow is really a complex pattern of mixed flows. Thus in a shell and tube heat exchanger, TLM is used along with a correction factor (F) to account for the geometry of the exchanger and for the fact that flow is not truly cocurrent or counter-current. Thus the equation for heat transfer for a shell and tube heat exchanger can be written as: q = Uo * Ao * F * TLM (22)

where F is correction factor. The product of F and TLM is termed the Corrected Mean Temperature Difference (CMTD). So the equation for heat transfer becomes: q = Uo * Ao * CMTD

where CMTD = F * LMTD and LMTD = TLM The correction factors are determined from the LMTD Correction Factor tables found in the GPSA Handbook (page 9-4, 9-5). Most heat exchangers in service require a correction factor as most of them have more than one tube pass. The correction factors are given in the handbook in terms of two dimensionless ratios: (a) The temperature ratio: R = (T1 T2) / (t2 t1) (b) The effectiveness ratio: P = (t2 t1) / (T1 t1) (23) (24)

In both the above expressions the higher case (T) is used for the shell fluid temperature and the lower case (t) is used for the tube side fluid. In the GPSA hand book, Section 9 deals with industrial heat exchangers. Typical values of the overall heat transfer coefficient for heat exchanger use in the natural gas industry are given in Figure 9-9. All heat exchangers in use have a specification sheet with all the relevant operational data. An example of a heat exchanger specification data sheet is given in Figure 9-12 in the hand book.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 24 of 33

Sample Problems on Heat Exchangers: Example 1 Water at a flow rate of 550 kg/hr is cooled in a double pipe heat exchanger from 50oC to 25oC by a cool brine solution which enters at 5oC and exits at 12oC. If the overall heat transfer coefficient is 1020 W/(m2 oC), what is the heat exchanger area required for (a) co-current flow and (b) counter-current flow ? (Given Cp for water is 4176 J / (kg oC). Solution: The heat transfer rate (q) can be found from the data for the water stream: q = m*Cp * Th = 550 kg/hr *4176 J/(kg oC) * (50 - 25) oC * 1/3600 sec./ hr = 15950 W (Watts) The heat transfer rate can also be written as q = U * A * TLM Solving for the heat transfer area A, q A = --------------U * TLM Now TLM ( T2 - T1) = ----------------------ln (T2 /T1 ) T1 = LTTD = 25 - 12 = 13 oC

T2 = GTTD = 50 - 5 = 45 oC and Thus TLM

( 45 - 13) = ------------------- = 25.77 oC ln (45 /13 ) = 0.607 m2 (answer a)

15950 W So A = ---------------------------------1020 W /(m2 oC) * 25.77 oC

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 25 of 33

(b) For counter-current flow conditions, T2 = GTTD = 50 - 12 = 38 oC and T1 = LTTD = 25 - 5 = 20 oC and TLM ( 38 - 20) = ------------------- = 28.04 oC ln (38 /20) (answer b)

So

15950 W A = --------------------------------- = 0.558 m2 1020 W /(m2 oC) * 28.04 oC

(note: for the same heat duty, the counter current arrangement requires less area).

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 26 of 33

Example 2 Water at a rate of 68 kg/min is heated in a counter current double pipe heat exchanger from 35 oC to 75 oC by a hot oil stream entering at 110 oC and leaving at 75 oC. The heat capacity of the water is 4.19 kJ/kg oC and the heat capacity of the oil is 1.9 kJ/kg o C. The overall heat transfer coefficient for the exchanger is 320 W/m2 oC. What is the required flow of the oil and the required surface area of heat transfer? Solution: The heat transfer rate is determined from the heat absorbed by the water: q = mw * Cp(w) * Tw = 68 kg/min * 1/(60 sec/min) * 4.19 kJ/kg oC * (75 35) oC = 189.95 kW = 189950 W = 189 .95 kJ/sec = 189950 J/sec. This amount of heat is equal to the heat given up by the oil. Therefore, q = 189.95 kW = moil * Cp(oil) * Toil moil 189.95 kW 189.95 kW = ------------------ = ----------------------------Cp(oil) * Toil 1.9 kJ/kg oC * (110 75) oC = 2.86 kg/sec = 171.6 kg/min. (answer) Calculating heat transfer area: LMTD for the exchanger is given by: TLM (75 35) - (110 75) = ----------------------------------ln (( 75 35) /(110 75)) q A = ----------U * TLM = 37.44 oC

Area of the exchanger,

189950 J/sec = ------------------------320 W/m2 oC * 37.44oC

Therefore A = 15.85 m2 (answer)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 27 of 33

Example 3 Instead of the double pipe heat exchanger of the previous example, it is desired to use a shell and tube exchanger with water making one shell pass and the oil making two tube passes. Calculate the area required for this exchanger, assuming that the overall heat transfer coefficient remains at 320 W/m2 oC. Solution: To solve this problem, we have to determine a correction factor for the LMTD calculated on the basis of a counter current exchanger. As already mentioned the correction factor can be found from pages 9-4 and 9-5 in the GPSA Hand Book. For this problem, R = (T1 T2) / (t2 t1) = (35 75) / (75 110) = 1.143 P = (t2 t1) / (T1 t1) = (75 110) / (35 110) = 0.467 The correction factor (F) for a 1 shell pass and 2 tube passes exchanger (1-2 exchanger) is found to be: F = 0.81 Thus writing the expression for the area of the exchanger to include the correction factor: q 189.95 kJ/sec A = ----------- = -----------------------------------------U *F *TLM 320 W/m2 oC * 0.81 *37.44oC A = 19.53 m2 (answer)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 28 of 33

Example 4 A shell and tube heat exchanger operates with 2 shell passes and 4 tube passes. The shell fluid is ethylene glycol (specific heat = 2.5 kJ/kg oC) which enters at 140 oC and leaves at 80 oC with a flow rate of 4500 kg/hr. Water flows in the tubes, entering at 35 o C and leaves at 85 oC. The overall heat transfer coefficient for this arrangement is 850 W/m2 oC. Calculate the flow rate of water required and the area of the exchanger. Solution: To calculate the heat transfer rate, we take the glycol stream as all data for this stream is known: q = mg * Cp(g) * Tg = (4500 kg/hr * 1/3600 s/hr ) * 2.5 kJ/kg oC * (140 80)oC = 187.5 kW = 187.5 kJ/sec = 187500 J/sec Find the flow rate of the water: 187.5 kW 187.5 kW mw = ------------------ = ----------------------------Cp(w) * Tw 4.18 kJ/kg oC * (85 35) oC = 0.89713 kg/sec. = 3229.7 kg/hr. Find the area of the exchanger: Since this is a shell and tube exchanger, we need correction factor for the LMTD (TLM). TLM (140 85) (80 35) = ----------------------------------ln ((140 85) (80 35)) = 49.85 oC Find the correction factor for this exchanger: R = (T1 T2) / (t2 t1) = (140 80) / (85 35) = 1.2 P = (t2 t1) / (T1 t1) = (85 35) / (140 35) = 0.476

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 29 of 33

Correction factor F from hand book : F = 0.95 If we write the expression for the area of the 2-4 exchanger, q 187500 J/sec A = ----------- = ------------------------U *F *TLM 850 W/m2 oC * 0.95 *49.85oC A = 4.66 m2 (answer)

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 30 of 33

Lesson 4
Fixed and Floating Head Heat Exchangers Heat exchangers with fixed tube sheets are difficult to clean, both on the shell side as well as in the tube side. Also there is virtually no provision for differential thermal expansion of the tube bundle and the shell which can be caused by large temperature differentials between the shell and tube fluids. To allow provisions for easy removal of the tube bundle for cleaning and to allow for thermal expansion a floating head heat exchanger is used (Fig., page 25 ). In this type of heat exchanger, one of the tube sheets is independent of the shell so that the entire tube bundle can be removed for cleaning of the shell and the outside of the tubes. This also allows for differential expansion between the tube s and the shell.

LESSON 5

routing of the fluids in a shell and tube heat exchanger


If one of the fluids fouls up the surfaces much more rapidly than the other, it should be routed through the tubes, since the inside of the tubes can be cleaned without removing the tube bundle from the shell. If both the fluids are equally non-fouling, and one is under high pressure, it should flow inside the tubes to avoid the expense of a high pressure shell. When only one of the fluids is corrosive, it should flow inside the tubes to avoid the expense of special metal for both shell and tubes. If one of the fluids is much more viscous than the other, it may be routed through the shell to increase the overall heat transfer coefficient. At times, because of the limitation in available pressure drop, it is necessary to route a given stream through the shell.

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 31 of 33

A Floating Head 2 4 Shell and Tube Heat Exchanger

Extended Surface Tubing

Integrated Training Program / Phase A Heat Transfer Copyright 2004 International Human Resources Development Corporation

Page 32 of 33

LESSON 6

Extended Surface Heat Exchangers


If heat exchange occurs between two fluids where one fluid has a very high resistance to heat transfer in comparison to the other, the higher resistance fluid controls the rate of heat transfer. Such cases occur, for example, in the heating of air by steam or in heating of a very viscous oil, flowing in laminar flow, by a molten salt mix. The relative magnitude of the heat transfer coefficient is about 60 W/m2 oC for the oil or air, compared with 12000 W/m2 oC for the steam or salt (200 times greater). Consequently, the overall coefficient is essentially equal to the individual coefficient for the air or oil (close to 60 W/m2 oC); the capacity of a unit area of heating surface will be low, and many lengths of tube will be required to provide a reasonable capacity. In order to compensate for the high resistance of the oil or air, the heat transfer surface exposed to these fluids may be increased by extension of the surface, as in the addition of fins to the outside of the tubes . The fins are referred to as extended surfaces. These extended surfaces increase the heat transfer area substantially in a given amount of space. A common example of extended surface heat exchanger is the automobile radiator.