Sei sulla pagina 1di 8

Date : 8/Sep/03 CONTROL ROOM AT VAPI FIRST SLAB LEVEL Design of Two way slab marked : General Data

Grade of Concrete Grade of Steel Density of Concrete Shorter Span of slab Lx Longer Span of Slab Ly Ly/Lx Edge condition (Panel) : S3 = = = = = M20 Fe415 25 3 5 ( 20 ( 415 kN/m3 m m N/mm2 ) N/mm2 )

= 1.666667 . 5 Two Short Edges Discontinuous = = 140 15 mm mm

Trying and adopting Thickness of slanb Clear Cover to reinforcement Loading on Slab Dead Load - Self Weight ( 0.14 x 25 ) - Floor Finish load - Other Dead Load Live Load Total Design Load

= = = = =

3.5 1

kN/mm2 kN/mm2 kN/mm2 kN/mm2 kN/mm2

5 9.5

Along Short Span Moment coefficient a Mu = 1.5 ( a x w x Lx2) Effective Depth K = Mu/bd2 Pt of steel required Area of Steel Required Ast min @ 0.12 % Midspan 0.047667 6.11325 121 0.418 0.124 150 168 #8 250 mm c/c Support 0.063333 8.1225 121 0.555 0.165 199 168 #8 250 mm c/c #8 500 mm c/c 301.59 0.2493

Along Long Span Midspan 0.035 4.48875 117 0.328 0.098 115 168 #8 250 mm c/c Support 0 0 117 0.000 0.006 7 168 #8 250 mm c/c #8 500 mm c/c 301.59 0.2578

Provide Dia. And Spacing as (# indicates HYSD Bar) Extra top

Area of Steel Provided Pt. Provided

201.06 0.1662

201.06 0.1718

Date : 8/Sep/03 CONTROL ROOM AT VAPI FIRST SLAB LEVEL DEFLECTION CHECK :- (REF. CLAUSE 23.2.1 OF IS:456) Basic Allowable 'Lx/d' ratio without modification Steel Stress of Service Loads is given as fs = 0.58.fy [ Ast / Ast(pr.) ] Modification factor as per SP:24 (Clause 22.2) 1 0.225+0.00322.fs-0.625 log10(bd/Ast(pr)) Permissible 'Le/d' ratio with modification factor Actual Span/Depth ratio, Lx / d = = = = = 26 180.12 N/mm2 1 0.317827 = 2 2.0000 52.000

( subjected to max MF=2

26.000 x 24.793 <

= 52.000 HENCE O.K.

REFERENCES :1) IS:456 (CODE OF PRACTICE FOR PLAIN AND REINFORCED CONCRETE 2000)

A) TABLE : 26 BENDING MOMENT COEFFICIENT FOR RECTANGULAR PANELS SUPPORT ON FOUR SIDES WITH PROVISION FOR TORSIONAL REINFORCEMENT. B) CLAUSE 26.5.2.1 FOR MINIMUM REINFORCEMENT IN SLABS 2) SP:16 (DESIGN AIDS FOR REINFORCED CONCRETE TO IS:456 - 1978) CHART:22 CONTROL OF DEFLECTION (PAGE NO. 44) EFFECTIVE DEPTH CALCULATION :ASSUMED OVERALL DEPTH CLEAR COVER TO REINF. MAXIMUM BAR SIZE EFF. DEPTH FOR MAIN REINF. EFF. DEPTH FOR SEC. REINF. = = = = = = = 140.00 mm 25.00 mm 10.00 mm 140.00 110.00 110.00 100.00 mm mm 25.00 10.00

3)

MATERIALS USED :1) 2) GRADE OF CONCRETE GRADE OF TOR STEEL = = M20 Fe415

1)

DESIGN OF SLAB MARKED :

TS1, TS22

THICKNESS =

DATA AVAILABLE :SPAN ALONG SHORTER SIDE, Lx SPAN ALONG LONGER SIDE, Ly RATIO OF SPANS, Ly / Lx CONTINUITY ALONG PERIPHERY DEAD LOADS :a) Self weight of slab b) Floor-finish + Water-proofing = = 0.140 x (assumed) 2550 = = = = = = 5.230 m c/c. & = 5.760 m c/c. & = 1.1060 TWO ADJACENT EDGES DISCONTINUOUS

c) False Ceiling LIVE LOADS :a) Considering accessible roof THUS TOTAL LOADS, w

50.00

= =

DESIGN PARTICULARS

ALONG Lx MID-SPAN SUPPORT

a) b) c) d) e) f) g) h)

Coefficient (IS456) Mu = 1.5 (.w.Lx.Lx) Effective depth, d in mm K = Mu / b.d.d in N/sqmm. Percentage of Reinf. 'pt' Area of Reinforcement 'Ast' 'Ast' minimum @ 0.12% Provide dia. & spacing as (T indicates HYSD bars - Fe415 gr.) Area of Steel provided, Ast(pr.) pt (pr.) = 100 Ast(pr.) / b.d

0.0403 1375.70 110 1.1369 0.3439 378.33 168.00 T 10.00 @ 140.00 mm c/c 561.00 0.5100

0.0534 1822.88 110 1.5065 0.4663 512.94

i) j)

DEFLECTION CHECK :- (REF. CLAUSE 23.2.1 OF IS:456) Basic Allowable 'Lx/d' ratio without modification Steel Stress of Service Loads is given as fs = 0.58.fy [ Ast / Ast(pr.) ] Modification factor as per SP:24 (Clause 22.2) 1 = = = 26 162.32 N/mm2 1 =

0.225+0.00322.fs-0.625 log10(bd/Ast(pr)) Permissible 'Le/d' ratio with modification factor Actual Span/Depth ratio, Lx / d

= = =

0.564915945 26.000 x 45.455 <

ONCRETE 2000)

NGULAR PANELS SUPPORTED NFORCEMENT.

10.00 /

2.00

140.00 MM

5.000 m clear 5.530 m clear

ES DISCONTINUOUS

357.00 Kg/m2 275.00 Kg/m2

50.00 Kg/m2 682.00 Kg/m2

150.00 Kg/m2 832.00 Kg/m2

ALONG Ly MID-SPAN SUPPORT

0.0350 1194.77 100 1.1948 0.3626 362.61 168.00 T 10.00 @ 200.00 mm c/c 392.70 0.3927

0.0470 1604.41 100 1.6044 0.5000 500.03

N/mm2 1.7702

1.7702 46.025

= 46.025 HENCE O.K.

Potrebbero piacerti anche