Trolley mounted magnetic therapy devices with 2 and 4 independent outputs

0476

Magnetomed 8200

Magnetomed 8400

Magnetomed 8200: Trolley mounted magnetic therapy generator with 2 independent outputs and the option of activating the outputs with the following combinations: 1+2 independent 1+2 simultaneously (ideal for total body treatment where simultaneous double solenoid piloting is required).

Magnetomed 8400: Trolley mounted magnetic therapy generator with 4 independent outputs and the option of activating the outputs with the following combinations: 1 2 3 4 independent 1+2 simultaneously 3, 4 independent 1+2 simultaneously and 3+4 simultaneously. 1+2+3+4 simultaneously.

Magnetic therapy
26

0476

Magnetomed 7400

Magnetomed 7200

Magnetomed 7100

Magnetomed 2000

Magnetomed 7400: Table based magnetic therapy generator with 4 independent coupled outputs and the option of activating the outputs with the following combinations: 1+2 simultaneously 3+4 simultaneously (ideal for "total-body" treatment where simultaneous double solenoid piloting is required).

Magnetomed 7200: Table based magnetic therapy generator with 2 independent outputs, and the option of activating the outputs with the following combinations: 1, 2 independent 1+2 simultaneously (ideal for total body treatment where simultaneous double solenoid piloting is required). Magnetomed 7100: Table based magnetic therapy generator with 1 output Magnetomed 2000: Table based magnetic therapy generator with 2 independent outputs..

Magnetic therapy
27

Table based devices for magnetic therapy with 1 - 2 and 4 outputs

CP30
Portable 30 cm diameter cylinder for treatment of lower or upper limbs Portable 30 cm diameter cylinder with feet to support it on flat surfaces, with the exclusive MFC patent that concentrates the force lines inside the solenoid and does not disperse them towards the outside (in accordance with Legis. Decree 626). North Pole identification for correct orientation.

CP50
Portable 50 cm diameter cylinder for treatment of upper or lower limbs Portable 50 cm diameter cylinder with feet to support it on flat surfaces, and the exclusive MFC patent that concentrates the force lines inside the solenoid and does not disperse them towards the outside (in accordance with Legis. Decree 626). North Pole identification for correct orientation.

CP
Applicator couple size 16x10x3.5 for localised treatment Applicator couple that can be operated both by the side method (to treat large areas) and the opposing method (to concentrate the magnetic induction in a restricted area). Plastic container covered in grey imitation leather to identify the North Pole and blue to identify the South Pole Reduced weight and minimum heat during operation.

Magnetic therapy
28

Optional accessories and supplied accessories

LC60/2 - Bed + 2 cylinders for total body treatment


High tech aluminium bed with 2 sliding rails and 2 cylinders, 60 cm in diameter and 36cm in width each), covered in imitation leather. Exclusive MFC patent that concentrates the force lines inside the solenoid and does not disperse them towards the outside (in accordance with Legis. Decree 626). The 50 cm cylinder glides along ball bearings and can travel for 40% of the total length. The 60 cm cylinder glides along ball bearings and can travel for 100% of the total length overlapping the 50 cm cylinder in the final part. In comparison with standard systems, this system gives greater space to the patient who can easily stretch out along the bed. North Pole identification for correct orientation.

LC60 - Bed + cylinder for standard treatment


High tech aluminium bed with 2 sliding rails and 1 cylinder 60 cm in diameter and 36cm in width. It is covered in imitation leather, and has the exclusive MFC patent that concentrates the force lines inside the solenoid and does not disperse them towards the outside (in accordance with Legis. Decree 626). The 60 cm cylinder glides along ball bearings and can travel for 100% of the total length. North pole identification for correct orientation.

Magnetic therapy
29

Optional accessories

SA
Stand + crescent shaped Applicator for treatment when sitting. High tech aluminium stand and crescent shaped solenoid that can slide up. Sliding can be started from 40 cm. Ideal for treatment while sitting or for patients that cannot use the bed.

Accessories supplied

7100

7200 - 8200

7400 - 8400

2000

Power cable Users manual Fuses Ring magnet


(For testing the device)

1 1 2 x 1.6 A-T 1

1 1 2 x 3.15 A-T 1

1 1 2 x 6.3 A-T 1

1 1 2 x 3.15 A-T 1

Magnetic therapy
30

Optional accessories and supplied accessories

Along with their applicators, magnetic therapy devices generate magnetic fields that can be adjusted in intensity and frequency, producing induction in the surrounding area and shown graphically in Figure 1: The force lines are strongest near the solenoid and decrease as you move outwards from it. The maximum power is at the contact point with the solenoid, and the intensity produced outside the cylinder is similar to that inside. From this description, it can be understood that any person that is in the area or passing by will be subjected to the effects of the electromagnetic field in addition to the patient inside the solenoid. The intensity is still significant at 50-60 cm from the solenoid.
fig. 1

All magnetic therapy equipment on the market produces this effect. It means that any persons in the vicinity of the applicators and solenoids are overexposed to undesired electromagnetic fields. In order to resolve this serious problem, after a long period of research and study, EME Srl developed the exclusive MFC patent (d. n PS2000U00044) which uses a special device to significantly reduce the magnetic induction produced outside the solenoid and which concentrates the force lines inside the solenoid. Therefore it is the patient who will feel the effects and not the operators. The effect is shown in the diagram in fig. 2.
fig. 2

Tests carried out show that by using the MFC patent, electromagnetic pollution in the area is reduced by more than 85%. This brings the device into compliance with the new regulations introduced by Legis. Decree 626 implementing the following directives
89/391/CEE 89/654/CEE 89/655/CEE 89/656/CEE 90/269/CEE 90/270/CEE 90/394/CEE 90/679/CEE

on the improvement of health and safety for workers in their places of work.

Magnetic therapy
31

The MFC patent - Magnetic Field Concentrator

The Magnetomed series is another step forward in the field of magnetic therapy. Thanks to its advanced technology this device can now be continually updated and will be able to carry out functions that become available in the future. By using a smart card or an Internet connection, this computer derived technology means that you can easily update the unit by adding functions, protocols, and anything else our research and development department makes available. Magnetomed emits low frequency pulsed magnetic fields (adjustable from 1 to 100 Hz) and

intensity up to 100 Gauss per single output. The wide range of accessories available means that you can optimise treatment for those conditions that respond well to magnetic therapy. The 2 and 4 output models are capable of providing effective total body treatment. You can create customised patient profiles with the smart-card. A useful encoder means that you can quickly select the current or the protocol to use by accessing a library of over 100 programmes, or you can create and store up to 400 simple or sequential operational protocols.

Technical features
Power supply Maximum mains power asborption Fuses Backlit LCD Display to view and check the operating paramenters Programmable treatment time Programmable treatment frequency Maximum induction Isolation classification Risk classification (93/42/CEE) Degree of protection from liquids MFC patent that reduces electromagnetic pollution by more than 85% Output channels

7100
230 Vca 50-60Hz, 10% 210 W 2 x 1.6 A-T Graphics 320x240 DPI 1-99 minutes
1-100 Hz 100 Gauss 20%

7200 - 8200
230 Vca 50-60Hz, 10% 410 W 2 x 3.15 A-T Graphics 320x240 DPI 1-99 minutes
1-100 Hz 100 Gauss 20%

7400 - 8400
230 Vca 50-60Hz, 10% 810 W 2 x 6.3 A-T Graphics 320x240 DPI 1-99 minutes
1-100 Hz 100 Gauss 20%

2000
230 Vca 50-60Hz, 10% 410 W 2 x 3.15 A-T Graphics 24x64 DPI 1-99 minutes
1-100 Hz 100 Gauss 20%

I type BF IIA IPXO

I type BF IIA IPXO

I type BF IIA IPXO

I type BF IIA IPXO

7400: 2+2 independent 8400: 4 independent

Stored protocols Storable protocols in the internal memory Storable protocols with the Smart Card Power greater than 400 Gauss Option of solenoid piloting in various shapes and sizes Protection from short circuiting Duty cycle controllable from 10% to 100% Weight

100 200 200

100 200 200

100 200 200

20 10


3,5 Kg 39x14x30 cm


7200: 3,5 Kg 8200: 27 Kg 7200: 39x14x30 cm 8200: 39x86x31 cm


7400: 4 Kg 8400: 27 Kg 7400: 39x14x30 cm 8400: 39x86x31 cm


4 Kg

Size

39x14x30 cm

Magnetic therapy
32

Technical specifications

Magnetomed treatment induces the following biological effects: 1. basic general action by magnetic fields on the plasmatic membrane as shown by the more significant experimental data studied by us. It is primarily represented by: modification of the membrane permeability and therefore the ionic equilibrium on both its sides (improvement in ionic exchange and increase in oxygen uptake and use); influence on the flow of ions (especially calcium) through the membrane itself with its action dependant on the frequency used (greater oxygen uptake and therefore energy for the mechanisms that drive the ionic pumps); influence on many enzymatic intracellular systems and on the membrane; influence on the relationship between antigens and antibodies; influence on the layout and orientation of the molecules that are on the sides of the membrane and that have their own magnetic moments, and are involved in those biological processes that need steric positions imposed by the molecules in order to develop (active transport, hormone-receptor complexes, transmitter-receptor enzymatic reactions, antigen-antibody reactions, etc.) 2. on the blood: beneficial action on the vessel diameter and on the viscosity of blood with improvement of local circulatory conditions and oxygen pressure (hypervascularization). This also explains the acceleration in the healing process of soft tissue and bone injuries and trophic injuries with peripheral circulatory origin, and the beneficial effect on biological structures that depend on the diffusion of oxygen, like cartilage for example. 3. on the immune system: increase in immunoglobulin-G and circulating leucocytes with strengthening of the immune system; regulation of steroid substance and endogenous opioid production (therefore modulating the pain system). 4. on the endocrine system: inhibition of some hormonal functions (parathyroid) and stimulation of others (Pineal melatonin). 5. on the central and peripheral nervous systems: reduction in sympathetic system activity (due to probable hyperpolarisation of the pre and post-synaptic membranes, or modulating the vasodilation stimuli frequencies); alteration of cerebral cellular activity. 6. on metabolism 7. on cell reproduction 8. on tissue regeneration: for the magnetic field action on collagen genesis by fibroblasts, on the angiopoiesis with neoformation of blood vessels (that explains the beneficial effects of magnetic fields on healing wounds, sores, and numb sores). 9. on bone tissue: osteogenesis is stimulated where it doesn't occur naturally (pseudoarthrosis, consolidation delays) providing the necessary signals for cell reactivation (mesenchymal periosteum, monocytes, fibroblasts, osteoblasts that encourage the formation of internal callus), improving blood uptake, inhibiting the parathormones and therefore encouraging osteoblast activity.

Main Magnetomed applications:


Traumatology Rheumatology Angiology Neurology Dermatology Endocrinology Orthopaedics
Pseudoarthrosis Fractures at risk of pseudoarthrosis Delay in healing of fractures Soft area injuries (bruises, sprains, burns) - Oedema Skin wounds - Dislocations Degenerative rheumatism Inflammatory rheumatism Fibromyalgic rheumatism Peripheral arteriopathy in lower limbs - Bed sores and venous ulcers Post herpetic neuralgia Lumbago Sciatica - Schizophrenia Psoriasis - (Atrophic) dermatitis Geriatric and post-menopausal osteoporosis Knee arthrosis Vertebral arthrosis Bursitis Cervicobrachialgia Stress lumbago - Shoulderhumeral periarthritis (including calcified)

Magnetic therapy
33

Use of the equipment and stored programmes