Sei sulla pagina 1di 8

Current Cycle Data Sheet

ANSI C119.4.
Class of Test Test Method:
Connector Type: Part Tested: Date Started: Date Completed:_ Project # Current Cycle: On Period (Hrs) Off Period (Hrs) Test Current:

A
CCT
Compression

Select The Class of Test First Select The Test Method Second Select the Connector Type

Amps

Cable (main) Size Type Stranding Insulation Length Crimping Tool Die Number Number of Crimps Size Select Type Type

Cable (Tap) Conductor Preparation:

Stranding Insulation Length

Main

Tap

Connector Temp (C) Measurement Point 1 2 3 4 5 6 7 8 9 10 Req'd Cycle Actual Cycle Number number C1 25-30 45-55 70-80 95-105 120-130 160-170 200-210 245-255 320-330 400-410 C2 C3 C4

Control Conductor (C)

11

495-505 Blank Blank Blank Blank Blank Blank Blank Blank Blank Blank Blank Blank Blank Blank

ycle Data Sheet

Compounded? Compound Wire Brushed?

No n/a Yes

Ambient (C)

Cycle Number

* Record Ambient at time resistance is measured Connector Resistance (Measured) Micro Ohms () Ambient @ Reading (C) C1 C2 C3

C4

ANSI C119.4
Class of Test
Part Tested: Cable (main) Size Type Stranding Insulation Length

A
Date Started: Cable (Tap) Size Type Stranding Insulation Length Off Period (Hrs)

Current Cycle Data Sheet


1/0/00 Date Completed:_ 1/0/00 Conductor Preparation: Compounded? No Compound n/a Wire Brushed? Yes

Test Method:
Project # 0

Current Cycle: On Period (Hrs) Connector Type: Crimping Tool Die Number Compression 0 Main Control Conduct or (C) 0 0 0 0 0 0 0 0 0 0 0

Test Current:

Amps

Die Number Tap

Measurement Points 1 2 3 4 5 6 7 8 9 10 11

Cycle Number 0 0 0 0 0 0 0 0 0 0 0

Ambient (C) 0 0 0 0 0 0 0 0 0 0 0

Connector Temp (C) C1 0 0 0 0 0 0 0 0 0 0 0 C2 0 0 0 0 0 0 0 0 0 0 0 C3 0 0 0 0 0 0 0 0 0 0 0 C4 0 0 0 0 0 0 0 0 0 0 0

Temperature Difference (C) C1 0 0 0 0 0 0 0 0 0 0 0 C2 0 0 0 0 0 0 0 0 0 0 0 C3 0 0 0 0 0 0 0 0 0 0 0 C4 0 0 0 0 0 0 0 0 0 0 0 C1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Stability Factor (Si) C2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Average Temperature Difference Maximum Stability Factor


1. The connector temperature cannot exceed the control conductor temperature

0.0

0.0

0.0

0.0 0.0 0.0 0.0 0.0


2. The stability factor Si shall not exceed 10 for each of the connector temperature measurements recorded at the specified intervals.

Measurement Points 1 2 3 4 5 6 7 8 9 10 11

Cycle Number 0 0 0 0 0 0 0 0 0 0 0

Ambient (C) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Control Conduct or (C) 0 0 0 0 0 0 0 0 0 0 0

Connector Resistance (Measured) Micro Ohms () C1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Connector Resistance

Micro Ohms () C2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 C4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Average Resistance Min Acceptable Resistance Max Allowable Resistance

0.0 0.0 0.0

0.0 0.0 0.0

0.0 0.0 0.0

0.0 0.0 0.0

3. The resistance of the connectors tested shall not vary by more than 5% from the average of the measured values.

ANSI C119.4
Heat Cycle Temperature and Resistance Graphs 0 Heat Cycle Temperature
1 0.9 0.8 0.7

Temperature C

0.6 0.5 0.4 0.3 0.2 0.1 0 0 0 0 0 0 0 0 0 0 0 0

Cycles
C1 C2 C3 C4 Control Ambient

Heat Cycle Resistance


1.0 0.9 0.8 0.7 Resistance (u ohms) 0.6

0.5
0.4 0.3 0.2 0.1 0.0 0 0 0 0 0 0 0 0 0 0 0

Cycles

C1

C2

C3

c4

Wire Type AL CU ACSR n/a

Resistance constants 0.0036 0.004 0.004

Class Method AA CCT A CCST B C

Type Mechanical Compression

Potrebbero piacerti anche