ADVISOR

CD 7212 CD95/15012

Installation Manual

Software from Version: V6.0

142938999-1

COPYRIGHT SLC BV 1997. All rights reserved. No part of this publication may be reproduced, transmitted, stored in a retrieval system, or transmitted in any form, or by any means - electronic, photocopying, recording, or otherwise - without the prior written permission of SLC BV. DISCLAIMER SLC BV makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose. Further SLC BV reserve the right to revise this publication and to make changes from time to time in the contents hereof without the obligation of SLC BV to notify any person of any such revision.

HOW TO USE THIS MANUAL

This manual contains installation details for the CD72, CD95 and CD150. When used in conjunction with the Programming Manual and the User Manual, it provides the installation engineer with basic installation and programming information.

Programming
The 'Programming Manual' for the CD72 or the CD95/CD150 covers all necessary aspects of programming the system. Everybody involved in installing or maintaining this panel should have access to a copy of this manual. The 'Programming Manual is available from your ARITECH national office. The Programming Map for the various systems can be found at the end of this manual.

Installation manual for CD72/95/15012

Page 3

Page 4

Installation manual for CD72/95/15012

CONTENTS

INSTALLATION GUIDELINES ..................................................................................................... 7


Before switching on the power..................................................................................................... 8
Figure 1. Separate alarm and tamper connection ............................................................... 8 Figure 2. Joint Connecting the alarm & tamper ................................................................... 8 Figure 3. Overview of the dipswitches on remotes.............................................................. 9

PROGRAMMING GUIDE .......................................................................................................... 11


Figure 4. Keys on a CD30xx.............................................................................................. 11

Returning to default settings...................................................................................................... 12 Leaving programming mode...................................................................................................... 13 Dialler ........................................................................................................................................ 13 Other manuals........................................................................................................................... 13

INSTALLATION GUIDE ........................................................................................................... 14


Wiring diagrams CD72 .............................................................................................................. 14
Figure 5. CD72 cabinet...................................................................................................... 14 Figure 6. CD72 control panel............................................................................................. 15

Wiring diagrams CD95/150 ....................................................................................................... 16


Figure 7. CD95 cabinet...................................................................................................... 16 Figure 8. CD150 cabinet.................................................................................................... 16 Figure 9. CD95/150 control panel...................................................................................... 17

Opening CD3008 / CD3048 keypad .......................................................................................... 18


Figure 10. Opening the CD3008 / CD3048 keypad.......................................................... 18

Opening CD3009 / CD3049 keypad .......................................................................................... 18


Figure 11. Opening the CD3009 / CD3049 keypad........................................................... 18

CD3008 / CD3009 keypad......................................................................................................... 19


Figure 12. CD3008 / CD3009 keypad ............................................................................... 19

CD3048 / CD3049 keypad......................................................................................................... 19


Figure 13. CD3048 / CD3049 keypad ............................................................................... 19

CD9031 expander ..................................................................................................................... 20


Figure 14. CD9031 expander ............................................................................................ 20

Keypad back tamper ................................................................................................................. 21 Connecting an extra power supply............................................................................................. 22


Figure 15. Use of an extra power supply........................................................................... 22

Inputs ........................................................................................................................................ 22 Connecting a detector without memory ..................................................................................... 23


Figure 16. Dual loop Connecting a detector without memory............................................ 23

Connecting a detector with Latch .............................................................................................. 23


Figure 17. Dual loop Connecting a detector with latch ...................................................... 23

Connecting a key switch............................................................................................................ 24


Figure 18. Connecting a key switch with LED's................................................................. 24

Connecting a nitewatch system............................................................................................... 24


Figure 19. Connecting a CP4005 Nitewatch PCB ............................................................. 24
Installation manual for CD72/95/15012 Page 5

Connecting a fire detector ......................................................................................................... 25


Figure 20. Connecting a fire detector ................................................................................ 25

Outputs ..................................................................................................................................... 26 Connecting a relay or an LED.................................................................................................... 26


Figure 21. Connecting a relay or an LED on the output .................................................... 26

Connecting an AS256 and AS294/394 sounder ........................................................................ 27


Figure 22. Connecting the AS294/394 + internal siren AS256 .......................................... 27 Figure 23. Connecting the AS294/394 .............................................................................. 27

Connecting the GS600/610/710/711 shock sensor (CD72 only)................................................ 28


Figure 24. Connecting the GS710/711 with separate alarm & tamper loops .................... 28 Figure 25. Connecting the GS710/711 with combined alarm & tamper loops................... 28

Printer output............................................................................................................................. 29
Figure 26. Printer connection ............................................................................................ 29

AS270/AS271 internal siren....................................................................................................... 30

SPECIFICATIONS .................................................................................................................. 31 PROGRAMMING MAP CD7212 .............................................................................................. 33 PROGRAMMING MAP CD95/15012 ....................................................................................... 37

Page 6

Installation manual for CD72/95/15012

INSTALLATION GUIDELINES
The CD72, CD95/150 control panels have been designed, assembled and tested to meet current standards of stability and resistance to electrical interference from the environment. If the following guidelines are followed, the system should give many years of reliable service.

1.

Ensure that there is a good earth for the alarm system.

A GOOD EARTH IS ESSENTIAL FOR EFFECTIVE RESISTANCE TO ELECTRICAL INTERFERENCE

Do not forget to provide a (network) earth for the telephone dialler. 2. Maintain a good separation between low voltage and mains supply cables, and use separate points of entry into the control panel cabinet. Avoid loops of wire inside the control panel and route cables so they do not lay on top or underneath the printed circuit board. The use of cable ties is recommended and improves neatness in the box. Mains switching relays must NOT be fitted inside the control panel cabinet. The switching of these relays may cause electrical interference. 4.1 4.2 4.3 Use a relay with good insulation between the contacts and the coil. Place a suppression diode (e.g. a 1N4001) across the relay coil. Relays connected to open collector outputs of the alarm system should be rated at 12 volts DC with a coil impedance greater than 400 Ohms.

3.

4.

5.

The remote bus cable is used for communication between the control panel and the keypads/expanders. The greatest care should therefore be taken when installing this cable. NEVER split this cable into separate cables. Do not use cables with wires which are used for TELEPHONE connections or for switching, for example, flashing lights, sirens or relays. Avoid cable ducts and cable ways which contain mains power cables. This is particularly important when such ducts contain cables supplying electric motors, fluorescent lights or 3-phase power. If this is not possible, shielded cable should be used and the cable should be earthed at the control panel end ONLY.

6.

Installation manual for CD72/95/15012

Page 7

BEFORE SWITCHING ON THE POWER


1. Detectors (or key switches) can be connected in two ways:

Conventional:

One zone each is required for both tamper and the alarm. Both zones should be closed with an end-loop resistor (4.7 kOhm). Program the zones menu as Alarm

Figure 1. Separate alarm and tamper connection

Dual loop:

The alarm and tamper are placed together in one zone. The zone has two end-loop resistors (4.7 kOhm) to differentiate between alarm and tamper. Figure 2 shows how they are connected. Program the zones menu as Dual.

Figure 2. Joint Connecting the alarm & tamper

This connection method gives the following input values: The zone is on standby triggered open short-circuited Resistance 3k5 - 6k2 6k6 - 11k7 > 12k7 < 2k9 Panel zone voltages 2.1 - 2.8 V 2.9 - 3.6 V > 3.7 V < 1.9 V
Table 1. Operation of the inputs

Remote zone voltages 4.7 - 6.8 V 6.9 - 8.6 V > 8.7 V < 4.6 V

Reaction none alarm tamper tamper

Page 8

Installation manual for CD72/95/15012

2.

Set the DIP switches of all the remote keypads and expanders. Remote 1 must be a keypad. CD72, remotes 2 to 4 must be keypads and remotes 5 and 6 expanders. CD95/150, remotes 2 to 8 can be keypads or expanders but remotes 9 to 16 must be expanders.

ON 1 CD95/150 CD72 2

SD 3 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

Keypad 1 Keypad 1 (all off) ON 1 2 SD 3 4

Remote 2 Keypad 2

Remote 3 Keypad 3

Remote 4 Keypad 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

CD95/150 CD72

Remote 5 Expander 1

Remote 6 Expander 2

Remote 7

Remote 8

ON 1 CD95/150 only 2

SD 3 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

Expander 9

Expander 10

Expander 11

Expander 12

ON 1 CD95/150 only 2

SD 3 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

ON 1 2

SD 3 4

Expander 13

Expander 14

Expander 15

Expander 16

Figure 3. Overview of the dipswitches on remotes

3.

Close the tamper switches on the remote keypads, expanders and the control panel. Also close all zones which can cause a direct alarm. If this is not done, the system will be triggered as soon as it is switched on.

4.

Remove link LK1 or JP1 from the PCB so that it returns to default settings.

Installation manual for CD72/95/15012

Page 9

5.

Supply only mains power to the control panel. The system will power up in the ARMED state. Any zones that may be open will initiate a full alarm condition and the sounders will activate. Do not use a battery to power the system when installing or changing the installation. If there is a short circuit in the 12 volt power supply, the voltage regulators in the supply (together with the fuses) will prevent serious damage to the system The 12 volt power supply will decrease sharply in the event of a short circuit. If a short circuit should occur, remove the 12 volt connections one by one. When the connection with the short circuit is removed the power supply will return to 12 volts.

NOTE: ONLY KEYPAD ONE IS OPERATIONAL.

Every time power is removed from the system the control panel memorises its status. If power is restored to the panel, the system starts up again in this status (except if LK1/JP1 has been removed). 6. Enter 0 followed by the default user code 1122 at keypad 1. 'Disarm? is shown on the display. System then disarms. If the sirens have been activated, these will now stop. The status of the system or the time and date will now appear in the display. 7. Enter 0 followed by the default engineers code 1278 at keypad 1 and press to return to programming mode.

N.B.

Do not forget to initialise additional keypads and expanders with the menu: INSTALL REMOTE Replace LK1/JP1.

Page 10

Installation manual for CD72/95/15012

PROGRAMMING GUIDE
1. Take some time to become familiar with the overview of the programming maps which can be found at the end of this manual.

2.

Any programming changes made may not take effect until you exit programming mode.

3.

If while programming an option the message No Privilege is displayed, the configuration is Split System and you do not have access to all the areas. This may be caused by not obtaining Extended Access (Maintenance menu), or because one or more of the areas are armed.

4.

The following keys may be used:

DISPLAY
ABC DEF GHI Accept

Always enter a 0 before entering an engineer/user code to prevent errors ! Under keys 1 to 9 there are 3 letters of the alphabet: press the keys repeatedly to enter first the number, then the lower case letters and then the upper case letters. Keys 9 and 0 have special symbols such as the comma and space. The arrows move the cursor during entry. Press to accept an entry. Cancel an entry by pressing X. To delete a character, overwrite with another character or a space.

1
JKL

2
MNO

3
PQR

End

4
STU

5
VWX

6
YZ

7
Cursor left

8 0

9
Cursor right

up

down

Figure 4. Keys on a CD30xx

Note: CD30xx stands for the keypads: CD3008, CD3048, CD3009 and CD3049

Installation manual for the CD72/95/15012

Page 11

RETURNING TO DEFAULT SETTINGS


There are two methods of returning the system (not the dialler) to default settings, these are:

1.

The removal of JP1 (CD72) or LK1 (CD95/150). Subject to the Engineers Lock not being programmed, this method will return the panel to default settings without the use of an engineers code. Proceed as follows: Remove both the battery and the mains power. Remove jumper JP1/LK1. Connect the mains power. Only keypad 1 is operational. The software version is displayed on the other keypads (if present). As the default setting is armed any open zones will trigger the system and the sounders will activate. Enter 0 followed by the default code 1122 to disarm the system. Use code 1278 to return to programming mode. If the default codes are invalid, the system had Engineers Lock blocking programmed. If the current engineers code is known use procedure 2, if not, then replacement of the PCB is the only way to gain access to programming mode.

2.

By programming. Use this method if Engineers Lock blocking is active and the engineers code is known. Proceed as follows: KEYPAD ONE MUST BE USED FOR THIS PROCEDURE ALL AREAS MUST BE DISARMED Go to keypad 1. Enter the installation engineers code. If the system is split, you will be asked for an area number, enter 1, press and you will enter the Maintenance section of the engineers programming menu. Accept this and use the down arrow key until Extended Access is displayed. Accept this to gain extended access, then press X to return to Maintenance. Press 7, 6 and 1 successively. You are now in the menu Miscellaneous, Factory Prog. Menu, Default Settings. Are you sure? flashes in the display. If No Privilege appears, there are two possibilities: You are not at keypad 1 The system is split and you do not have access to all areas. Check this using Extended Access. Press accept (). Wait ... appears in the display. The system has now reverted to default settings.

Page 12

Installation manual for the CD72/95/15012

LEAVING PROGRAMMING MODE


Before leaving programming mode use the Show Open Zones facility under the Maintenance menu (menu 1.3). If any zones shown are 24Hr zones (e.g. tamper or fire) the alarm will activate on leaving the engineers programming mode. If dual loop is programmed, the letter T will appear next to the zone number to indicate the tamper section of the loop is open. Procedure: a. Check for open 24Hr zones (see above). b. Press X until Goodbye is displayed. c. Press accept .

DIALLER
The use of the RD6203 dialler is recommended. This dialler fits inside the control panel cabinet and is connected to the control panels PCB using the cable supplied. The dialler may also be programmed via the keypad. A separate manual is available for the dialler.

OTHER MANUALS
Programming Manual CD72 or CD95/150 User manual Manager Manual Programming Manual RD6203 A fully documented programming information manual. Separate versions for the CD72 and the CD95/150 Details user options A user manual which examines the options in more depth. Intended for the manager. Documented information on programming the RD6203 dialler

Installation manual for the CD72/95/15012

Page 13

INSTALLATION GUIDE
WIRING DIAGRAMS CD72
Power supply adjustment (DO NOT ADJUST) Fixing hole

Printer connector

Main PCB

Cable entries

Transformer

230V connection

BATTERY Fixing hole

Fixing hole

Main PCB RD6203 Dialler

To hold lid in place while servicing the panel

Figure 5. CD72 cabinet

Page 14

Installation manual for the CD72/95/15012

See section specifications

F6 F5
5 4 3 2 1 A B C D JP1 43 42 41 Outputs 40 39 38 37 to keypads and 36 expanders 35 34 Line Fault 33 external tampering 32 Ext. Siren 31 Tamper 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 + + + 13 12 11 10 9 8 7 8

J1

To RD6203

CD7203
Eprom

Processor

Tamper switch

EEprom

Zones

F4
See section specifications

F3 F2 F1
RS232 printer

1 External siren (O/put 19) Internal siren (O/put 18) Aux. power

+
1 2 3 4
18VAC Battery

PL1

Figure 6. CD72 control panel

Installation manual for the CD72/95/15012

Page 15

WIRING DIAGRAMS CD95/150


Power supply adjustment (DO NOT ADJUST) Fixing hole Memory card connector Dialler connector Input expander socket LED power on Printer connector RS232 Fixing hole

Main PCB Output expander socket Fold lid down (CD95)

Cable entries

Transformer

RD6203 Dialler BATTERY Fixing hole

Mains cable entry

Fixing hole

Figure 7. CD95 cabinet


Power supply adjustment (DO NOT ADJUST)

Fixing hole

Dialler connector Memory card selector Dialler connector

Printer connector RS232 RD6203 Dialler Output expander socket Fuse holder Mains cable entry

Cable fixing points

BATTERY Transformer

Screw holes for cover Wall fixing holes

Pull forward

Lift up

Opening the cabinet

Main PCB

Unscrew the screws (2x)

Remove earth connection

Figure 8. CD150 cabinet

Page 16

Installation manual for the CD72/95/15012

Power output 18VAC Battery

External siren O/put 50 Internal siren O/put 49 to keypads and remotes 50 49 48 47 A B C D 46 45 44 43 42 41 40 39 8

Printer RS232 60 59 58 57 56 55 54 53 52 51 + - + - + - + -

F8

Outputs 1

CD9005
F7 F6
See section Specifications

Output Expander
Output 41 to 48

F5 F4 F3 F2 F1

8 7 6 5 4 3 2 1

38 FTC/Reset (in) 37 line fault (in) 36 external tampering 35 tamper 34 siren 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 Zones 16

Tamper Switch (CD95 only)

CD9503/ CD15003

LK1

CP4003
Input Expander
Eprom

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

zone 144 to 152 Connector memory card To RD6203

Figure 9. CD95/150 control panel

Installation manual for the CD72/95/15012

Page 17

OPENING CD3008 / CD3048 KEYPAD

Figure 10. Opening the CD3008 / CD3048 keypad

OPENING CD3009 / CD3049 KEYPAD

Lift up

Push

Remove screw if installed

Push clip in with screwdriver and lift up cover

Figure 11. Opening the CD3009 / CD3049 keypad

Page 18

Installation manual for the CD72/95/15012

CD3008 / CD3009 KEYPAD


Display contrast adjustment Keypad address setting switches

Cable entry from top

Fixing hole Push the side clip to remove PCB


1 2 3

Fixing hole Extra screw to secure lid


4 7 5 8 6 9 D C B A

Cable entry from back 4-wire bus connection Fixing hole Cable entry from bottom

Buzzer volume adjustment

Figure 12. CD3008 / CD3009 keypad

CD3048 / CD3049 KEYPAD


Display contrast adjustment Keypad address setting switches Cable entry from top

Zones
ON 4
OFF

Fixing hole
3 2

Push side clip to remove PCB Cable entry from back Power connection Four-wire bus connection Fixing hole Cable entry from bottom

3 1

Fixing hole Extra screw to secure lid


4 7 5 8 6 9

OB + D C B A

Buzzer

Jumper to cut Buzzer volume adjustment off Buzzer

Figure 13. CD3048 / CD3049 keypad

Remote connections A B C D

CD 72 38 37 36 35

Connection to CD 95/150 50 49 48 47

Installation manual for the CD72/95/15012

Page 19

CD9031 EXPANDER
Cable entry from top Fixing hole
TAM
OB OA D C B A

Fixing hole

1 Cable entry from back 2 3 4 Zones 5 6 7 Fixing hole 8

Outputs Four-wire bus connection

Processor

Reverse tampering

Cover tampering

Fixing hole

Cable entry from bottom

Expander Address setting switches

with lid tamper = Link 1-2 without lid tamper = Link 2-3

Lid tamper

Figure 14. CD9031 expander

Remote connections A B C D

Connection to CD 72 CD 95/150 38 50 37 49 36 48 35 47

Page 20

Installation manual for the CD72/95/15012

KEYPAD BACK TAMPER

CD30xx base . When the keypad lid is not used, remove the hinge-slot blanking pieces from the base and place them in the hinge-slot openings

For back tamper protection fix the screw through the hole into the wall .

Installation manual for the CD72/95/15012

Page 21

CONNECTING AN EXTRA POWER SUPPLY


An auxiliary power supply will be required if the voltage is too low as a result of large cable runs or the current demand is in excess of the panels current supply rating. To connect an extra power supply the + of the panel must not be connected to the + of the auxiliary power supply. Also do not connect the + of different auxiliary power supplies together. If the auxiliary power supply is used to power a remote expander/keypad, connect the + of the four wire bus (A) to the + of the auxiliary power supply. A common reference is obtained by connecting together all power supplies -. IMPORTANT: NEVER INTERCONNECT POSITIVES OF POWER SUPPLIES. ALWAYS INTERCONNECT NEGATIVES OF
POWER SUPPLIES

CD72/95/150 To Power Monitor zone Central power supply

4K7

4K7

4-wire bus

+
DE

A B C D

RC813

RC900

4 + +
BU4

Detects failure of the mains power

A B C D
4-wire bus of keypad or expander

Auxiliary power supply PG822

Detector, siren, relay, etc...

Figure 15. Use of an extra power supply

INPUTS
Panel CD72 Numbering
Keypad 1

Panel CD95/150 1....16


Keypad 3 Keypad 4

Expander socket CD95/150 145....152


Expander 5 Expander 6

1....8
Keypad 2

CD72

9....12
Keypad 1

13....16
Remote 2

17....20

21....24

9....16

17....24
Remote 7 Remote 8

Remote 3

Remote 4

Remote 5

Remote 6

CD95/150 CD95/150

17....20
Remote 9

25....32
Remote10

33....40
Remote11

41....48
Remote12

49....56
Remote13

57....64
Remote14

65....72
Remote15

73....80
Remote16

81....88

89....96

97....104

105....112 113....120 121....128 129....136 137....144

Table 2. Numbering of the inputs

Note: In the CD72 the expanders have priority over the keypads !

Page 22

Installation manual for the CD72/95/15012

CONNECTING A DETECTOR WITHOUT MEMORY

4k7

4k7

A
1 2 3

A
4 5

S
6

S
7

Power supply

Input zone

Figure 16. Dual loop Connecting a detector without memory

CONNECTING A DETECTOR WITH LATCH

4k7

4k7

A
1 2 3

A
4 5

S
6

S
7 8

M
9

W
10

Power supply

Input zone

Output Latch

Output Walk test

Figure 17. Dual loop Connecting a detector with latch

Note: Before connecting, the cable between terminal 2 and terminal 10 should be removed!

Installation manual for the CD72/95/15012

Page 23

CONNECTING A KEY SWITCH


C NO 4k7 NC
Input zone key Key switch

4k7 C NC
Tamper +12V

Output Arm/Disarm Output System Clear Programme outputs for negative applied
Figure 18. Connecting a key switch with LED's

CONNECTING A NITEWATCH SYSTEM


4K7

Input zone
4K7

CP 4005 Light zone 1 / Light zone 2 / Daylight zone

Figure 19. Connecting a CP4005 Nitewatch PCB

Page 24

Installation manual for the CD72/95/15012

CONNECTING A FIRE DETECTOR

CD72/95/150

- O1 + O1 = Fire reset - O2 = External siren O3 = Fire -

O2 O3 +
This extra connection is only necessary if a continuous signal from the external siren is required

RC213

RC213

1
To terminal 5 of the RC213 relay. To + terminal of the panel

To siren control (Sc)

3 4
7 8

2
9

DB602 + DP611/ DI612/ DT613

1
NO C

OR

5
NC

DB822 + DP803

4K7

4K7

4K7

4K7

To fire zone

To fire zone
Figure 20. Connecting a fire detector

Note 1:

If there are several detectors place them in parallel and cable the zones as described in figure 1 or 2 (see page 8). This connection also applied for detectors which require a reset after an alarm, e.g. the GS900 etc. The reset is performed after the second entry of a code after an alarm. Programme zone loop as Dual. Programme all outputs for negative applied -.

Note 2:

Note 3: Note 4: Note 5:

Installation manual for the CD72/95/15012

Page 25

OUTPUTS
Panel CD72 CD95/150 1....5 1....8 Internal siren 18 49 External siren 19 50 41....48 Output expander

Keypad 1

Remote 2

Remote 3

Remote 4

Remote 5

Remote 6

Remote 7

Remote 8

OA CD72 CD95/150 6 9

OB 7 10

OA 8 11

OB 9 12

OA 10 13

OB 11 14

OA 12 15

OB 13 16

OA 14 17

OB 15 18

OA 16 19

OB 17 20

OA 21

OB 22

OA 23

OB 24

Remote 9

Remote10 Remote11 Remote12 Remote13 Remote14 Remote15 Remote16

OA CD150 25

OB 26

OA 27

OB 28

OA 29

OB 30

OA 31

OB 32

OA 33

OB 34

OA 35

OB 36

OA 37

OB 38

OA 39

OB 40

Table 3. Numbering of the outputs

NB:

In a keypad OA is the buzzer. OB does not exist in a CD3008 / CD3009 keypad.

CONNECTING A RELAY OR AN LED


+12 Volt NC NO +12 Volt R = 820

Output

Output

Figure 21. Connecting a relay or an LED on the output

The resistor R is necessary to adjust the current. This may not be greater than 40 mA. For most LEDs, however, a current of approximately 15 mA is sufficient. The resistance calculation is as follows:

V I

13,8V Vled 15 mA

13,8V 2V 15mA

787

When rounded off this is 820 Ohms.

Page 26

Installation manual for the CD72/95/15012

CONNECTING AN AS256 AND AS294/394 SOUNDER


CD72 CD95/150 32 33 35 36 11 52 10 51 30 31 33 34 8 57 13 54 12 53 39 39

4K7

+ T AS256

+ T Sc AS294 / AS394

Bc

Figure 22. Connecting the AS294/394 + internal siren AS256

Programming Beacon control Internal siren control External siren control

CD72 01 Int Sir Sy + 18 Int Sir Sy 19 Ext Sir Sy +


Table 4. Programming for the sirens

CD95/150 01 Int Sir Sy + 49 Int Sir Sy 50 Ext Sir Sy +

NB:

If the tampers must be placed in separate zones, they can be connected according to figure 1 (1 endloop resistor) or figure 2 (2 end-loop resistors) (see page 8).

Cut these 2 jumpers for negative Hold-Off. The other 2 jumpers for positive Hold-Off.

Figure 23. Connecting the AS294/394

Installation manual for the CD72/95/15012

Page 27

CONNECTING THE GS600/610/710/711 SHOCK SENSOR (CD72 ONLY)

Figure 24. Connecting the GS710/711 with separate alarm & tamper loops

Figure 25. Connecting the GS710/711 with combined alarm & tamper loops

Page 28

Installation manual for the CD72/95/15012

PRINTER OUTPUT
PL1 (CD72) PL4 (CD95/150)

DB25 RS232

PL1 (CD72) PL4 (CD95/150)

DB9 RS232

Figure 26. Printer connection

Installation manual for the CD72/95/15012

Page 29

AS270/AS271 INTERNAL SIREN

Note: *) **) This fixing screw is used for pry-off tamper. Screw to close siren.

Connection: 1. 2. 3. 4. 5. Tamper Tamper + 12V - 0V Speaker - 0V Beacon

Programming in the panel: Connection AS270/AS271 1 Tamper 2 Tamper 3 + 12V 4 - 0V 5 - 0V 1 Tamper 2 Tamper 3 + 12V 4 - 0V 5 - 0V Programming Output Description Output Panel connection terminal 30 terminal 31 terminal 11 terminal 10 terminal 10 terminal 35 terminal 36 terminal 52 terminal 51 terminal 51

CD72

Internal siren Flash/Beacon

18 Internal siren 18 Internal siren -

CD95/150

Internal siren Flash/Beacon

49 Internal siren 49 Internal siren -

Page 30

Installation manual for the CD72/95/15012

SPECIFICATIONS
FUSES CD72
230 V fuse F1 F2 F3 F4 F5 F6 Battery Auxiliary power Internal siren External siren Dialler Remotes 315 mA 2A 1A 1A 1A 1A 1A 20x5 20x5 20x5 20x5 20x5 20x5 20x5 230 V fuse F1 F2 F3 F4 F5 F6 F7 F8 Dialler Output 8 Auxiliary power Battery External siren Internal siren Remotes Expander output

CD95/150
315 mA 800 mA 800 mA 1A 3,15 A 800 mA 800 mA 800 mA 800 mA 20x5 20x5 20x5 20x5 20x5 20x5 20x5 20x5 20x5

230 VAC Battery

secondary fuse 315 mA 12 Vdc, 16 Ah maximum for CD 72 12 Vdc, 24 Ah maximum for CD 95/150

Max. current consumption

max. 1.0 A, including remotes, dialler and unit for CD72 max. 2.0 A, including remotes, dialler and unit for CD95/150

Power consumption CD 72 CD 95/150 CD 3008/3009 CD 3048/3049 CD 9031 RD 6203 End of line resistors

typ. 66 mA 117 mA 26 mA 30 mA 26 mA 45 mA 4k7, 2 %, 0.25W 1 resistor for Alarm loop 2 resistors for Dual loop

max.

52 mA 55 mA 95 mA

Data bus A B C D Distance for data bus + 12V GND Data in (to panel) Data out (from panel)

Max 1500m.

Installation manual for the CD72/95/15012

Page 31

Dimensions (l x b x h) CD 3008/3048 CD 3009/3049 CD 9031 CD 72/95 CD 150 160 x 120 x 35 (3 mm ABS) 160 x 120 x 35 (3 mm ABS) 175 x 125 x 37 (3 mm polycarbonate) 315 x 385 x 88 (1,25 mm steel plate) 475 x 460 x 160 (1,25 mm steel plate)

Output no.
1 to 5 6 to 17 18 19

Location
control panel remotes internal siren CD72 external siren CD72

Output connected max.


100 mA 40 mA 1A 1A

Zone no.
1 to 8 9 to 24 n/a n/a

Table 5. Overview of the inputs and outputs on the CD72

Output no.
1 to 8 9 to 40 41 to 48 49 50

Location
control panel remotes expanders internal siren CD95/150 external siren CD95/150

Output connected max.


100 mA (output 8 = 1 A) 40 mA 100 mA (output 48 = 1 A) 1A 1A

Zone no.
1 to 16 17 to 144 145 to 152 n/a n/a

Table 6. Overview of the inputs and outputs on the CD95/150

Page 32

Installation manual for the CD72/95/15012

PROGRAMMING MAP CD7212


Note: The quick code numbers in front of each menu item (i.e. 2.4.4 to jump to Digi Cutout) are also the section heading numbers in the Menu Contents chapter of the programming manual, where the items are explained.

Installation manual for the CD72/95/15012

Page 33

Page 34

Installation manual for the CD72/95/15012

Installation manual for the CD72/95/15012

Page 35

Page 36

Installation manual for the CD72/95/15012

PROGRAMMING MAP CD95/15012


Note: The quick code numbers in front of each menu item (i.e. 2.4.4 to jump to Digi Cutout) are also the section heading numbers in the Menu Contents chapter of the programming manual, where the items are explained.

Installation manual for the CD72/95/15012

Page 37

Page 38

Installation manual for the CD72/95/15012

Installation manual for the CD72/95/15012

Page 39

Page 40

Installation manual for the CD72/95/15012