Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Figure 4-15 Diagrammatic cross sections illustrating (a) a simple ramp or "L" shape well; (D) a more complicated "S" shape weli ; (c) a horizonial well. [(a) and (b) published by permission of Tenneco Oil Company, (0) pubfished by permission of J. Brewton]
Electric Log Correlation Directionally Drilled Wells 83 relation sequence number 1. There are two wells drilled with a minimum down-dip deviation (Wells N0. B-5 and These Wells can be correlated to each other and then with the straight hole, Well No. B-l, drilled as a vertical well from the platform.
Step 5. Continue correlating wells with increased deviation in the down-dip direction. For this example, these are Wells N0. B-2 and B3, indicated by correlation sequence number 2. These two highly deviated wells can be correlated with each other and then with Wells No. and 8-6. Also, the vertical Well No. 3 may be used to correlate B-2 and B-3, since it is an off-structure well exhibiting a thick stratigraphic section. Step 6. When all wells classified as being deviated down-dip are correlated, the next group to correlate are those wells deviated along structural strike. From Platform B, Wells No. and B-9 fall into this category. These wells can be correlated to each other and then with straight hole B-l to close the loop. When correlating wells drilled along strike, the effect of bed dip is removed from the representative thickness of the directionally drilled wells. This can often simplify correlation. Step 7. Finally, correlate the wells deviated up-dip. Those Wells drilled closest to the crest of the structure usually are complicated by stratigraphic thinning, faulting, and unconformi ties. The correlation of these wells can be most difficult; therefore, they are normallyr correlated last when all other correlation information is available and you can recognize the best correlation markers. Wells No. B-4 and B-8 drilled from the B Platform fall into this category. They are labeled as correlation sequence number 4. Wells drilled in an up-dip direction can have variable log section thickness due to the geometric relationship between a wellbore and stmctural dip. A log section from a well drilled in an up-dip direction can be thicker, thinnet, or equal to the thickness of a log section from a nearby vertical well drilled through the same stratigraphic section. This potential complexity can add to the difficulty of correlating wells drilled in an up-dip direction. Because of these complexities, we recommend that these wells be correlated last, after significant knowledge is gained from other correlation work. Step 8. Generally, it is best to correlate wells located nearest each other, especially in areas where significant changes in stratigraphic thickness are probable. Wells nearest each other and approximately in the same structural position usually are expected to have the most com parable interval thicknesses. Step 9. After correlating the wells from one platform, begin correlation of wells on any additional platforms in the area. In Fig. 4-16. the A Platform wells in the northwest portion of the field should be correlated next. It is not necessary, however, to isolate correlation to a single platform. Often, wells from one platform are drilled in a direction toward another platform. If wells from separate platforms are in close proximity to one another, they should be correlated to each other. Notice that correlation sequence number 5 illustrates the correlation of 13-4 with A-5, and B-8 with A-4. Wells N0. A-1 and are straight holes drilled from separate platforms, but since they are located in a similar structural position, they can also be correlated to each other. The primary focus of this correlation plan is to provide a logical method for correlating all vertical and deviated wells in an area of study. The plan outlined is by no means the only one that can be used. The important point is to have a plan. Without one, log correlation becomes a random process, often resulting in some type of correlation problem or in miscorrelations.
Correlation of Vertical and Dlrectionally Drilled Wells In this section, we discuss general procedures for correlating vertical wells with directionally drilled wells. Directional wells have a measured log thickness (MLT) that can be less than, greater than, or equal to the log thickness in a vertical well drilled through the same stratigraphic section. These different MLTs result in additional complexities that must be considered when undertaking correlation work using well logs from both vertical and deviated wells. Now we look at the correlation of a vertical well with a deviated well. Figure 4- 17 shows a portion of an electric log from vertical Well No. A-1 and the electric log from directionally drilled Well No. A-2. The wells are in close proximity to each other. The detailed electric log correlation
(sand and shale sections) for both wells indicates that they have penetrated the same stratigraphic section. Although both wells have a high degree of correlation (see SRM 1 through SRM 4), the stratigraphic section in Well No. A-2 is much thicker than the same section seen in Well No. A-l. The log section in WelINo.A-1 from SRM 1 to SRM 4 is 490 ft thick. The same section in Well No. A-2 is 735 ft. Earlier in the chapter, in the discussion on vertical wells, we mentioned that a short section in one well with respect to another might be the result of stratigraphic changes or a fault. If the short section is isolated to one particular location, the short section is most likely the result of a fault rather than variations in stratigraphy. Conversely, if the short section is uniformly distributed over a series of intervals, the short section is probably due to stratigraphic variations rather than a fault. Based on correlation criteria, the thinner section in Well No. A-] appears to be the result of stratigraphic thinning rather than a fault. In this example, however, we introduce another possible explanation for the shortening. Since Well No. A-2 is directionally drilled, the thickness seen in the well with respect to Well No. A-l may be completely the result of the wellbore deviation. Figure 4-18 shows vertical Well No. A-1 and deviated Well No. A-Z in its true orientation with respect to the vertical. Well No. A-Z is drilled due west at a deviation angle of 48 deg (48 deg from the vertical). The correlation markers in each well show that the strata are horizontal and the thick section seen in Well No. A-2 is solely the result of wellbore deviation. We have now
AMPLIFIED SHORT NORMAL Figure 4-1? Portion of an electric log from a vertical well (A-l) and a directionally drilled well (A-2). The electric log sections show detailed correlations.
introduced another complexity in correlation that must be considered when both vertical ant deviated wells are present in the area of study. Here are several procedures that can be used to help correlate a vertical well with a directionally drilled well. 1. Mark the angle of deviation for the directional well on the log at least every 1000 ft. Thi: provides a reminder that the well is deviated and indicates the angle of deviation at 1000ft intervals on the actual log. ' 2. To compare interval thicknesses, slide the vertical well log as you correlate from markei to marker. This allows you to compensate during correlation for the expanded or reducet section in the directional well as a result of its deviation. 3. Calculate a thickness ratio for certain correlation intervals of interest to help evaluate whether any short section is the result of faulting. stratigraphic thinning, or just WCllbOl'f deviation (Fig. 4-18). 4. If a copy machine with a reduction mode is available, calculate the correction factor required to convert the deviated (stretched) log section to a vertical log section, and then reduce the log by the appropriate reduction factor. Use the reduced log for correlation. S. In areas of horizontal beds or low reliefi the MD leg from a deviated well can be corrected for wellborc deviation and converted into a TVD (true vertical depth) log to use for correlation. 6. In areas with bed clips greater than 5 to 10 deg, if dip data are available from a diprneter log or previously constructed structure maps, these data can be used to convert the deviated log to a TVT (true vertical thickness) log. A TVT log is one in which the measured thickness has been corrected for wellbore deviation and bed dip to the thickness represented in a vertical well. In areas of dip, a TV!) log provides little aid, if any, in correlation and can actually cause correlation problems (see section on MLT. TVDT. TVT, and TST).
on the log along with the amount of missing section, the depth of the fault, and the well(s) used to correlate the fault.
THICKNESS RATIO : Figure 4-18 Vertical Well No. A-1 and deviated Well No. A-2 (shown in its true orientation with respect to vertical). The correlation markers show that the thicker section in wet! No. A-2 is a direct result of its deviation from the vertical.
SHORT NORMAL AMPLIFIED SHORT NORMAL TOP OF 10000 SAND MISSING SECTION 150'
1 ,000' SAND
INTERVAL FAULTED
10,300' SAND
10,300' SAND
(a)
Figure 4-19a Detailed correlation oi a deviated well with a verlical well to locale the de pth and the missing sec-. tion for a fault in the deviated well. The base of the 10.000-ft Sand is faulted out.
(b)
Figure 4-19b The simplified stratigraphic section through Wells No. A-1 and A-2 illustrates that the missing section in Well No. A-2 is equivalent to the vertical section highlighted in Well No. A-1. No thickness correction tactor is required in this example.
The missing section in directional Well N0. is determined by correlation with Well NI which is a vertical well. In a vertical well, the log thickness and vertical thickness are ll'. same. Since missing section is expressed as the verticair thickness of the stratigraphic intent: faulted out of a well, the vertical thickness of the missing section in Well No. A:2 is 150 ft. Th 150 ft represents the missing section for the fault. This information will be used in future fau and structure mapping. Figure 4-19!) is a simplified stratigraphic section showing Wells No. A-1 and A-2 positione. in their true orientation with respect to the vertical. Well No. A-2, which is deviated at 48 de from the vertical, is pulled apart at the fault to show the restoration of the faulted-out section. Thi cross section clearly illustrates that the missing section in Well No. A-2 is equal to the 150 ft c vertical section highlighted in Well N0. A-l. Now consider a fault in vertical Well No. A-l correlated with deviated Well No. A-2 (Fig 4-20a). Well No. A-] has a fault near the base of the 10,000-ft Sand. Detailed correlation, a shown in the figure, identifies a 225-ft section in deviated Well N0. A-2 that is faulted out of We] No. A-l. The faulted-out section is highlighted in the figure. Since the missing section for th fault is determined as the TVT of the stratigraphic interval faulted out of the well, the estimate 0 225 ft of missing section based on the deviated log thickness must be corrected to express thl missing section in terms of TVT. Figure 4-20!) is a stratigraphic section showing Wells No. A-1 and A-2 positioned in thei: true orientation relative to vertical. The log section of Well No. A-l is pulled apart at the fault tr Show the restoration of the faulted out section. Since we are working in an area with horizonta beds, the correction of the measured log thickness in Well No. A-2 to TVT is determined by tht simple trigonometric solution of a right triangle. The insert in the center of the figure shows that the TVT of the missing section is equivalent to the vertical side of a right triangle whose hypotenuse is equal to the log thickness of the missing section in deviated Well N0. A2.
Where TVT (431 TVT True vertical thickness
MLT = Measured log thickness in deviated well : Angle of wellbore deviation from vertical
Therefore,