Sei sulla pagina 1di 2

HERMETIC

EVERGREEN

CENTRIFUGAL CHILLERS

For the Textile Industry No Compromises. Reliable operation based on ASME pressure vessel construction, the highest gear-rating class in the industry, steel-back babbitt-lined bearings, 0.1% design leak rate and 100% run-in testing. Ultra-high energy efficiency using HFC-134a and patented technology. Ease of service through optional built-in storage of refrigerant. Take-apart construction and small component parts allow easy installation while taking up less mechanical room floor space. Uses chlorine-free HFC-134a refrigerant, recognized as one of the safest refrigerants on the market today.

TEXTILE MILLS ARE PART OF CARRIERS HERITAGE

The Highest Efficiency Chlorine-Free Chillers In The World


Todays customers demand high-efficiency products with exceptional value. Carriers Evergreen centrifugal chillers provide this value by achieving energy efficiency levels, utilizing time-proven technology designed specifically for chlorine-free refrigerant. This combined effect ensures the most cost-effective, reliable solution to todays comfort cooling and process cooling applications. The addition of the turbine is a revolutionary advancement in technology. It represents the only major change to the basic vapor compression refrigeration cycle since the first centrifugal chiller was invented by Dr. Willis Carrier in 1922.

Reliable Operation
The Evergreen single-stage compressor design utilizes stationary tunnel diffuser technology to optimize compressor efficiency while reducing the total number of moving parts and increasing product reliability. Twenty-five years of operating experience go into each hermetic compressor motor. Since they are refrigerant cooled, Carriers Evergreen hermetic motors run cooler and cleaner, providing longer life while eliminating shaft seal leakage, high noise levels, and machine room cooling associated with open-motor designs.

Chlorine-Free HFC-134a Refrigerant


Evergreen chillers use chlorine-free HFC-134a refrigerant with zero ozone-depletion potential. As the refrigerant of choice for automotive and appliance manufacturers, HFC-134a production continues to rise assuring you a plentiful supply of refrigerant at reasonable prices in the years to come. The Evergreens positive-pressure design also reduces the chiller size by up to 35%, compared to negative-pressure designs, minimizing the need for costly mechanical room floor space. In addition, positive-pressure designs eliminate the need for expensive negative-pressure containment devices, reducing system first cost. With Carriers optional built-in isolation valves and unit-mounted pumpdown, refrigerant can be stored inside the chiller during servicing, reducing refrigerant loss and eliminating time-consuming transfer procedures.

Built-in Quality
All Evergreen heat exchangers are designed, manufactured, and tested to meet strict ASME section VIII, division I code for unfired pressure vessels. Compressors are 100% run-tested to ensure proper operation of all compressor systems, including electrical, oil management, power transmission, and compression. Controls and optional unit-mounted starters are tested for proper electrical function before and after unit mounting to ensure complete system operability. Carrier has invested significantly in the Evergreen product line to ensure that we provide you with the best value in highefficiency, chlorine-free centrifugal chillers.

Technological Leadership
In a breakthrough that utilizes advances adapted from Geothermal Power Turbine technology, Carrier has significantly reduced power consumption of HFC-134a positive-pressure chillers. The optional two-phase flow turbine expander is an energy reclaim system that attaches to an extended motor shaft on the chiller. Utilizing the HFC-134a pressure differential that exists between the condenser and the evaporator, the turbine supplements the energy furnished by the chiller motor, thus reducing external energy requirements. The result is ultra-high energy efficiencies, making the Evergreen chiller the highest efficiency chlorine-free centrifugal chiller in the world.

For more information, contact your local Carrier Representative or visit www.carrier-commercial.com.

PHYSICAL DATA
HEAT NOMINAL CAPACITY EXCHANGER SIZE (TONS) 200 225 250 300 350 450 500 550 600 700 800 1000 1200 1300 1500 10 to 12 15 to 17 20 to 22 30 to 32 35 to 37 40 to 42 45 to 47 50 to 52 55 to 57 60 to 62 65 to 67 70 to 72 75 to 77 80 to 82 85 to 87 (Length, with Nozzle-in-Head Waterbox) 2-Pass ft.-in. 11- 4 13- 73/8 11- 51/8 13- 81/4 15- 43/4 13-11 15- 8 13- 111/4 15- 73/4 13- 113/4 15- 81/4 16- 2 18- 2 18- 3 18- 3 mm 3454 4150 3483 4172 4693 4242 4775 4248 4769 4261 4782 4937 5537 4953 5603 1- or 3-Pass ft.-in. mm 11- 11 14- 21/4 12- 0 14- 31/4 15- 113/4 14- 7 16- 31/4 14- 63/4 16- 31/4 14- 71/4 16- 33/4 16- 10 18- 10 16- 11 18- 11 3632 4324 3658 4350 4870 4445 4959 4439 4959 4451 4972 5131 5740 5156 5766 ft.-in. 445- 53/4 5- 53/4 5- 53/4 6- 2 6- 2 6- 61/2 6- 61/2 6- 101/2 6- 101/2 7- 111/2 7- 111/2 8- 103/4 8- 103/4 113/4 113/4 Width mm 1518 1518 1670 1670 1670 1880 1880 1994 1994 2096 2096 2426 2426 2711 2711 Height ft.-in. 666- 31/4 6- 95/8 6- 95/8 7- 03/4 7- 03/4 7- 27/8 7- 27/8 7- 47/8 7- 47/8 9- 91/2 9- 91/2 9- 111/4 9- 111/4 11/4 11/4 mm 1861 1861 1911 2073 2073 2153 2153 2207 2207 2257 2257 2985 2985 3029 3029

Manufacturer reserves the right to make changes to products and specifications Carrier Corporation Syracuse, NY Printed in U.S.A. 0799 819-170