Specification and Parameters Item DK6-100 Type Current Limiting Lightning Arrestor Discharge Capacity 300kA (10/350s) Amplitude Damping Radio 82% Gradient Damping Multiplying Radio 35 Current Limiting Impedance Value 2 Weight (Kg) 45 Height (m) 2.1 Installation Size (mm) 1750.5 Zinc Coated Tower/pole (each piece, mm) 114X3000(H)X4(Screw) Art No. 100101001 Requirements of Installation and Detection Height of Installation At least 1.5m higher than the protected object Earthing Resistance 30 Earthing Downlead One piece or multi pieces of Steel Bar (Steel Flat) which Diameter (or equal sectional area) shall be no less than 8mm Wind Load No less than 45m/s Applicable Scope This product is widely used for preventing lightning direct stoke to the following area: Telecom, Petroleum, Chemical, Electric Power, Meteorology, Microwave Communication, Broadcasting, Oil Tank Farm, Electric Transformer Substation, Aviation, Financial System, Network, Industry and Highrise Building Usage 1. Conduct the direct lightning stroke 2. Leader Stroke in advance, conduct the electrical currents to ground, no phenomenon of shielding failure nor side stroke 3. Low grounding electrical currents, decrease the occurrence rate of counter strike which caused by potential difference that caused by enormous electrical currents flow to ground. Weaken the phenomenon of induced over-voltage caused by the enormous electrical currents presenting to the grounding weir.
Lightning arrester
Category: How things work
LIGHTNING ARRESTERS
The earthing screen and ground wires can well protect the electrical system against direct lightning strokes but they fail to provide protection against travelling waves, which may reach the terminal apparatus. The lightning arresters or surge diverters provide protection against such surges. A lightning arrester or a surge diverter is a protective device, which conducts the high voltage surges on the power system to the ground
Fig 7(i) shows the basic form of a surge diverter. It consists of a spark gap in series with a non-linear resistor. One end of the diverter is connected to the terminal of the equipment to be protected and the other end is effectively grounded. The length of the gap is so set that normal voltage is not enough to cause an arc but a dangerously high voltage will break down the air insulation and form an arc. The property of the non-linear resistance is that its resistance increases as the voltage (or current) increases and vice-versa. This is clear from the volt/amp characteristic of the resistor shown in Fig 7 (ii). The action of the lightning arrester or surge diverter is as under: (i) Under normal operation, the lightning arrester is off the line i.e. it conducts no current to earth or the gap is nonconducting (ii) On the occurrence of over voltage, the air insulation across the gap breaks down and an arc is formed providing a low resistance path for the surge to the ground. In this way, the excess charge on the line due to the surge is harmlessly conducted through the arrester to the ground instead of being sent back over the line. (iii) It is worthwhile to mention the function of non-linear resistor in the operation of arrester. As the gap sparks over due to over voltage, the arc would be a short-circuit on the power system and may cause power-follow current in the arrester. Since the characteristic of the resistor is to offer low resistance to high voltage (or current), it gives the effect of short-circuit. After the surge is over, the resistor offers high resistance to make the gap non-conducting.
VALVE TYPE ARRESTER EXPULSION TYPE ARRESTER MULTIGAP ARRESTER HORN GAP ARRESTER ROD GAP ARRESTER