Sei sulla pagina 1di 3

Automotive Cables Type GPT

General Purpose Thermoplastic Insulated

Description
Soft copper flexible conductor PVC insulated.

Construction
Conductor Flexible soft copper conductor, Class K stranded Insulation Flame Retardant Polyvinyl chloride (PVC 75 C)

Characteristics
Operating Temperature 75 C. Operating Voltage 50 V.

Applications
Low voltage automotive wiring. Insulation resistant to abrasion gasoline and oil.

Specifications
CENTELSA GPT Cables are manufactured under the following standards:
UL 1581, NTC-3203 Reference Standard for Electrical Wires, Cables and Flexible Cords SAE J1128 NTC-1116 Primary Low Voltage Cables Colors Black, white, red, yellow, blue, brown, orange grey and violet.

42

Packaging 100 m spools covered with plastic thermo pack, in corrugated carton boxes. Note: Other configurations, sizes, colors and length not specified herein are available upon request.

43

Automotive Cables Type GPT 50V, 75C (International System Units)


General Purpose Thermoplastic Insulated Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables

SIZE AWG

STRANDS

STRAND SECTION CONDUCTOR DIAMETER DIAMETER (mm2) (mm) (mm)

INSULATION THICKNESS (mm)

DIAMETER OVER INSULATION (mm)

APPROX. TOTAL WEIGHT (kg/km)

DC RESISTANCE AT 20C 1 (ohm/km)

22 20 18 16 14 12 10 8

7 10 16 26 41 65 104 168

0.254 0.254 0.254 0.254 0.254 0.254 0.254 0.254

0.35 0.51 0.81 1.32 2.08 3.29 5.27 8.51

0.76 0.97 1.23 1.51 1.98 2.52 3.21 3.66

0.58 0.58 0.58 0.58 0.58 0.66 0.79 0.94

1.76 1.97 2.23 2.51 2.98 3.62 4.51 5.20

6 8 11 16 24 38 59 93

49.6 34.7 21.7 13.3 8.46 5.34 3.34 2.07

Notes: 1. DC Resistance calculated based on a 17.241 ohm-mm2/km copper resistivity. 2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.

Automotive Cables Type GPT 50V, 75C


General Purpose Thermoplastic Insulated Standard: SAE J1128 NTC-1116, Primary Low Voltage Cables
SIZE AWG STRANDS STRAND SECTION CONDUCTOR DIAMETER DIAMETER (kcmil) (mils) (mils) INSULATION THICKNESS (mils) DIAMETER OVER INSULATION (mils) APPROX. TOTAL WEIGHT (lb/kft) DC RESISTANCE AT 20C 1 (ohm/kft)

22 20 18 16 14 12 10 8

7 10 16 26 41 65 104 168

10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0

0.70 1.00 1.60 2.60 4.10 6.50 10.40 16.80

30 38 48 59 78 99 126 144

23 23 23 23 23 26 31 37

69 78 88 99 117 143 178 205

4 5 8 11 16 25 40 62

15.1 10.6 6.61 4.07 2.58 1.63 1.02 0.630

Notes: 1. DC Resistance calculated based on a 10.371 ohm-cmil/ft copper resistivity. 2. Values herein indicated are approximated and are subject to normal manufacturing tolerances.