Flow Through An Orifice: How Orifice Size is Useful in Vacuum Pump Selection
Knowledge of the flow through an orifice and orifice size can be used in determining the sizing and selection of a vacuum pump or system. Many of the situations encountered when sizing vacuum equipment, particularly in material handling type applications are resolved with a basic understanding of how flow through an orifice works. To begin the discussion on flow, lets first define what we mean by the terms orifice and nozzle: An orifice can be defined as a round, straight hole having a sharp edge in a plate. A nozzle can be defined as a hole with a rounded entrance that transitions into a short, straight section at the throat. For simplicity and the purposes of this discussion, we will refer to both as an orifice. Flow The ow of gas through an orifice follows certain theoretical formulas. As with any theoretical formula, the exact results achieved may not match perfectly, but they are sufficiently close to use in estimating the expected performance requirement. To determine flow (in SCFM) through an orifice, the following equation is used: Q (ow) = A (area in in2) x V (velocity) There are two types of flow conditions depending on the velocity of the gas; sub-critical and critical flow. For air, when the vacuum level on the pump side of the orifice (i.e. downstream pressure) is less than half of an atmosphere (around 380 Torr), the velocity through the orifice is constantly changing along with the pressure level. In sub-critical flow, the level of SCFM is dependent on the vacuum level it increases as the pressure decreases (and vice versa). When the downstream pressure reaches half of an atmosphere, the velocity through the orifice becomes fixed (or sonic), and the flow condition changes to critical flow. In critical flow, as the downstream pressure level changes, the flow remains constant as the velocity is fixed. The only way to increase the flow would be to increase the size of the orifice (i.e. area). For all other gases, the critical ratio (rc) can be calculated as follows provided the ratio of specific heats (k) is known:

rc

P2 P1

( )
2 k+1

k k-1

Flow Through An Orifice: Vacuum Pump Selection

www.buschusa.com
Flow coefficient The flow coefficient of an orifice is a relative measure of its efficiency. The flow coefficient (C) of a typical sharp-edged orifice is generally accepted to be 0.61 (61% efficient), whereas the flow coefficient of a typical nozzle is generally accepted as 0.97 (97% efficient). Note that the presence of dirt or burrs on the orifice can significantly affect the efficiency, and hence flow capacity of the orifice. Figure 1 below illustrates this effect:

Figure 1
Orifice C = .61 Nozzle C = .97 C > .61 C < .61

Flow thru an Orifice When sizing vacuum pumps or vacuum systems that utilize an orifice, nozzle, slot, hole, etc., an orifice chart can be used to help estimate airow (SCFM) as shown in Figure 2. For slots, equating the slot area in square inches to the area in square inches of an orifice is used to determine the orifice equivalent. Flow (SCFM) through a Square Edge Orifice ORIFICEcient CHART Flow Coeffi = .61
Orifice Diameter 3/64 1/16 5/64 3/32 7/64 1/8 9/64 5/32 11/64 3/16 13/64 7/32 15/64 1/4 9/32 5/16 11/32 3/8 13/32 7/16 15/32 1/2 9/16 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4 Area in 0.0017 0.0031 0.0048 0.0069 0.0094 0.0123 0.0155 0.0192 0.0232 0.0276 0.0324 0.0376 0.0431 0.0491 0.0621 0.0767 0.0928 0.1104 0.1296 0.1503 0.1726 0.1963 0.2485 0.4418 0.7854 1.7671 3.1416 4.9087 7.0686 9.6211 12.5664 1 2 0.115 0.181 0.212 0.321 0.338 0.494 0.483 0.718 0.666 0.989 0.869 1.33 1.10 1.63 1.35 2.00 1.59 2.38 1.88 2.85 2.22 3.27 2.61 3.73 3.00 4.25 3.38 4.76 4.16 5.97 5.12 7.28 5.90 8.68 6.86 10.17 8.41 12.22 9.96 14.55 11.40 16.61 13.04 19.03 17.59 25.00 31.27 44.44 55.59 79.01 125.08 177.78 222.37 316.05 347.46 493.83 500.34 711.11 681.02 967.90 889.49 1264.20 3 0.220 0.386 0.620 0.881 1.21 1.60 2.01 2.47 2.92 3.51 4.00 4.59 5.22 5.89 7.29 8.73 10.52 12.59 14.84 17.54 20.33 23.30 30.32 53.90 95.83 215.61 383.30 598.91 862.44 1173.87 1533.22 4 0.246 0.439 0.701 1.01 1.39 1.84 2.30 2.81 3.38 3.99 4.57 5.28 6.02 6.80 8.32 9.96 12.12 14.46 17.06 19.92 23.04 26.42 34.39 61.14 108.69 244.55 434.76 679.31 978.20 1331.44 1739.03 5 0.270 0.483 0.774 1.12 1.53 2.04 2.53 3.10 3.75 4.37 5.08 5.87 6.66 7.54 9.25 11.07 13.40 16.07 18.82 22.07 25.23 28.90 37.72 67.06 119.21 268.23 476.86 745.09 1072.92 1460.37 1907.42 6 0.291 0.523 0.831 1.20 1.65 2.18 2.72 3.31 4.04 4.68 5.50 6.32 7.24 8.15 9.99 11.99 14.39 17.26 20.30 23.82 27.34 30.93 40.53 72.05 128.09 288.21 512.38 800.59 1152.85 1569.16 2049.52 Inches Hgv 7 8 9 0.312 0.329 0.344 0.559 0.591 0.615 0.873 0.908 0.950 1.26 1.33 1.38 1.75 1.82 1.89 2.30 2.40 2.48 2.86 2.97 3.09 3.50 3.66 3.81 4.25 4.43 4.58 4.94 5.16 5.35 5.82 6.08 6.31 6.66 7.00 7.27 7.66 7.99 8.32 8.66 9.05 9.40 10.72 11.20 11.74 12.79 13.48 14.05 15.32 16.11 16.92 18.30 19.19 20.20 21.60 22.71 23.77 25.27 26.66 27.75 29.10 30.62 31.88 32.78 34.65 36.21 43.12 45.20 47.12 76.66 80.36 83.77 136.28 142.85 148.92 306.63 321.42 335.08 545.12 571.42 595.69 851.75 892.84 930.77 1226.52 1285.69 1340.30 1669.44 1749.97 1824.30 2180.49 2285.67 2382.76 10 0.352 0.633 0.978 1.41 1.94 2.55 3.18 3.93 4.73 5.56 6.51 7.52 8.59 9.72 12.11 14.64 17.57 20.90 24.70 28.76 32.95 37.61 48.73 86.63 154.01 346.52 616.04 962.57 1386.10 1886.63 2464.17 11 0.360 0.645 1.00 1.45 1.99 2.59 3.25 4.03 4.84 5.72 6.70 7.75 8.82 10.02 12.58 15.17 18.27 21.68 25.61 29.72 34.14 38.82 50.20 89.24 158.66 356.98 634.63 991.60 1427.91 1943.55 2538.51 12 0.366 0.658 1.02 1.48 2.02 2.65 3.31 4.10 4.94 5.87 6.86 7.91 9.04 10.24 12.93 15.69 18.80 22.45 26.41 30.66 35.21 39.94 51.50 91.56 162.77 366.22 651.06 1017.28 1464.89 1993.88 2604.25 13 0.370 0.661 1.03 1.50 2.05 2.67 3.36 4.16 5.02 5.94 6.99 8.06 9.22 10.46 13.23 16.06 19.34 23.18 27.08 31.72 36.19 40.82 52.47 93.28 165.83 373.12 663.32 1036.44 1492.48 2031.43 2653.30

Figure 2
14 0.371 0.663 1.04 1.51 2.06 2.70 3.39 4.18 5.09 6.05 7.07 8.17 9.36 10.61 13.35 16.44 19.74 23.67 27.88 32.35 37.03 41.87 53.90 95.82 170.35 383.29 681.40 1064.69 1533.16 2086.80 2725.61 15-30 0.372 0.667 1.04 1.51 2.06 2.71 3.42 4.20 5.13 6.10 7.14 8.26 9.48 10.75 13.62 16.83 20.19 24.35 28.90 33.54 38.37 43.38 55.08 97.92 174.08 391.68 696.32 1088.00 1566.72 2132.48 2785.28

Flow Through An Orifice: Vacuum Pump Selection

www.buschusa.com
Orifice Ratios For most applications that use vacuum, multiple orifices are used. A high speed cartoning machine for example will typically use one or more sets of suction cups that grip or hold the box through the set up and unloading stages and where each cup uses an inner orifice through which the air is removed (or evacuated) by the vacuum system. In multiple orifice situations the sizing of the connecting lines or manifolds is key to the speed at which the air is removed and hence the machine/system efficiency. Often, incorrect manifolding of the orifices is witnessed. By introducing the concept of orifice ratios we can better assist the customer, be it an OEM or an end user. The term orifice ratio refers to the size of the area upstream on the orifice (towards the point of use) to the area downstream. As an example, consider a typical situation where four suction cups are used on a common arm or end effector, with each cup having an internal id orifice. It is not unusual that these cups would then be manifolded together into a common line, then to a single control valve that turns the vacuum on/off through the cycle. In this example, lets assume that the four cups are connected to a common line, then to a control valve. The below chart in Figure 3 provides the area for some of the common size orifices in sizes up to 6. Area Chart
Orifice Diameter 3/64 1/16 5/64 3/32 7/64 1/8 9/64 5/32 11/64 3/16 13/64 7/32 Area in 0.0017 0.0031 0.0048 0.0069 0.0094 0.0123 0.0155 0.0192 0.0232 0.0276 0.0324 0.0376 Orifice Diameter 15/64 1/4 9/32 5/16 11/32 3/8 13/32 7/16 15/32 1/2 9/16 3/4 Area in 0.0431 0.0491 0.0621 0.0767 0.0928 0.1104 0.1296 0.1503 0.1726 0.1963 0.2485 0.4418 Orifice Diameter 1 1 2 2 3 3 4 4 5 5 6 6 1/2 1/2 1/2 1/2 1/2 1/2

Figure 3
Area in 0.7854 1.7671 3.1416 4.9087 7.0686 9.6211 12.5664 15.9043 19.6350 23.7583 28.2743 33.1831

As shown in the table above, a id orifice has an area of .0491 in2. As we are using four in this example, we add the areas together to get a combined total area of .20 in2. In connecting the four together via the line, we now have a situation where the total orifice area in use is greater than the connected line area resulting in a pinch point in the system. Orifice ratios where the upstream area is greater than the downstream area result in situation likened to a vacuum rush hour traffic backup. Due to the pinch point, the air cannot be evacuated through the connected line as quickly as necessary so the evacuation to the desired pressure level is delayed.

Flow Through An Orifice: Vacuum Pump Selection

www.buschusa.com
In the curve set below in Figure 4, we represent the time it takes for the pressure levels on both sides of the orifice to equalize in a typical 4:1 orifice ratio situation (note that it takes almost 2 full seconds for the pressure to equalize). Eventually, the pressure drop is overcome and the levels will be the same, but at the expense of time. 4 : 1 Orifice Ratio Figure 4

A better solution is to manifold the cups to a connected line that has at least the same area as the total orifice area. In this example, using a line to manifold the cups and a minimum control valve (which should always be at least the same size or larger as the connecting line) changes the orifice ratio to 1:1. By working to maintain a 1:1 orifice ratio, the time it takes the pressure levels to equalize is greatly reduced and as a result, the vacuum level in the cup reaches the required level faster so that the machine can also run faster. This is represented in the curve set in Figure 5 below:

Flow Through An Orifice: Vacuum Pump Selection

www.buschusa.com
1 : 1 Orifice Ratio Figure 5

Conclusion By having a better understanding of flow conditions, flow through an orifice and orifice ratios, a more efficient vacuum solution can be realized. Often, there are opportunities to eliminate pressure drop in the system that hampers evacuation time by making some simple changes to connecting lines and control valves. Further, when reducing pressure drop in the system, pump sizing may also be reduced. Consider that if the upstream pressure required is 18 Hgv, but the downstream pressure required to maintain it is 24 Hgv, an efficiency opportunity exists. In this case the pump or system would need to be twice as large to overcome the pressure drop (P1/P2 or 12/6 = 2) than if there were zero delta P. The same also holds true for when a lower than necessary pressure level is specified or maintained where the lower pressure has no impact on the work being performed.

Flow Through An Orifice: Vacuum Pump Selection