Sei sulla pagina 1di 10

Page: 1

AIRFIELD LIGHTING PRIMARY CABLE


TSXB7Pe 5 kV Type C In compliance to FAA Specification for L-824, AC 150/5345-7E

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Brass Tape Shield 6. Polyester Tape 7. Extruded PE Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

No. of core and size

Max. Nominal Approx. Approx. Conducto Nominal conductor thickness Overall weight of r number Insulation resistance of Brass cable diameter of wire thickness at 20 C tape 7 mm 2.3 mm 0.1 mm 11.4 kg/km 189 /km 3.11

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 4,000 86

DTSXB7P0001065MC

1 x 6 mm

TSXC7Pe 5 kV Type C In compliance to FAA Specification for L-824, AC 150/5345-7E

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Copper Tape Shield 6. Polyester Tape 7. Extruded PE Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

DTSXC7PPVC1065MC

Nominal Max. Conducto Nominal thickness Approx. Approx. conductor No. of core Overall weight of of r number Insulation resistance and size cable of wire thickness Copper diameter at 20 C tape mm mm mm kg/km /km 1 x 6 mm 7 2.3 0.1 11.4 193 3.11

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 4,000 86

Page: 2

AIRFIELD LIGHTING PRIMARY CABLE

CU/XLPE/PE 5kV NON-SCREENED In compliance to FAA Specification for L-824, AC 150/5345-7E

Construction : 1. Round Stranded Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Extruded PE Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

No. of core and size

Conducto r number of wire

Nominal Insulation thickness mm 2.3

Max. Approx. Approx. conductor Overall weight of resistance cable diameter at 20 C mm 10.8 kg/km 132 /km 3.08

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 4,000 86

DNSXSTPE000106MC

1 x 6 mm

Page: 3

AIRFIELD LIGHTING PRIMARY CABLE

TCU/EPR/PE 5 kV
In compliance to BS 6234, BS 6360, BS 6007, BS 6746, M&E 42

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded EPR Insulation 3. Extruded PE Outer Sheath/Jacket *. Other color of Jacket is available

Item Code

No. of core and size

Max. Conducto Nominal Nominal Approx. Approx. conductor r number Insulation thickness Overall weight of resistance cable of wire thickness of Sheath diameter at 20 C 7 mm 2.8 mm 1.2 mm 11.1 kg/km 188 /km 3.11

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 600 72

DTCUEPRPE01065MC

1 x 6 mm

TCU/EPR/PCP 5 kV In compliance to FAA Specification for L-824, AC 150/5345-7E

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded EPR Insulation 3. Extruded Polycloroprene Sheath *. Other color of Jacket is available

Item Code

No. of core and size

Max. Conducto Nominal Nominal Approx. Approx. conductor r number Insulation thickness Overall weight of resistance cable of wire thickness of Sheath diameter at 20 C 7 7 19 mm 2.3 2.3 2.3 mm 1.2 1.2 1.2 mm 10.1 10.9 11.0 kg/km 128 166 167 /km 3.11 2.011 2.011

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 600 72 400 92 400 92

DTCUEPRPCP1065MC DTCUEPRPCP1085MC DTCUEPRPCP1185MC

1 x 6 mm 1 x AWG 8 1 x AWG 8

Page: 4

AIRFIELD LIGHTING PRIMARY CABLE


SINGLE CORE POLYETHYLENE INSULATED NYLON JACKETED CABLE

CU/LDPE/Nylon 3 kV AS 1125

Construction : 1. Round Stranded Copper Conductor to AS 1125 2. Extruded LDPE Insulation (Natural) 3. Extruded Nylon 12 Outer Sheath/Jacket (Black) *. Other color of Jacket is available

Item Code

No. of core and size

AN2YNYLON00016MC

1 x 6 mm

Max. Number Nominal Nominal Approx. Approx. conductor of wire & Insulation thickness Overall weight of resistance cable thickness of Sheath diameter dia at 20 C mm mm mm kg/km /km 7/1.04 1.9 0.35 7.7 95 3.08

Min. Insulation resistance at 20 C M.Ohm.km 4,000

PCU/PE/PVC 3 kV In compliance to BS 6234, BS 6360, BS 6007, BS 6746, M&E 42

Construction : 1. Round Stranded Copper Conductor 2. Extruded PE Insulation 3. Extruded PVC Outer Sheath/Jacket *. Other color of Jacket is available

Item Code

No. of core and size

Max. Conducto Nominal Nominal Approx. Approx. conductor r number Insulation thickness Overall weight of resistance cable of wire thickness of Sheath diameter at 20 C 7 mm 2.8 mm 1.2 mm 11.1 kg/km 164 /km 3.08

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 4,000 72

DPCUPEPVC01063MC

1 x 6 mm

Page: 5

AIRFIELD LIGHTING PRIMARY CABLE

FL2XCY 6 kV Type C In compliance to FAA Specification for L-824, AC 150/5345-7E

Construction : 1. Round Stranded Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Copper Wire Shield 6. Polyester Tape 7. Extruded PVC Anti Termite Outer Sheath/Jacket ( Red Color ) *. Other color of Jacket is available

Item Code

No. of core and size

Conducto Nominal r number Insulation of wire thickness mm 2.5

Dia of copper wire screen mm 0.5

Max. Approx. Approx. conductor Overall weight of resistance cable diameter at 20 C mm 15.2 kg/km 298 /km 3.08

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 4,000 86

DFL2XCY0010666MC

1 x 6/6 mm

FLYCY 6 kV Type C In compliance to FAA Specification for L-824, AC 150/5345-7E

Construction : 1. Round Stranded Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded PVC Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Copper Wire Shield 6. Polyester Tape 7. Extruded PVC Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

No. of core and size

Conducto Nominal r number Insulation of wire thickness mm 2.5

Dia of copper wire screen mm 0.5

Max. Approx. Approx. conductor Overall weight of resistance cable diameter at 20 C mm 15.2 kg/km 325 /km 3.08

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 60 62

DFLYCY00010666MC

1 x 6/6 mm

Page: 6

AIRFIELD LIGHTING SECONDARY CABLE


SRN 600 V Type A In compliance to FAA Specification, AC 150/5345-7E ( L-824)

Construction : 1. Round Bunhed Tinned Copper Conductor 2. Extruded Rubber Insulation 3. Extruded Polychloroprene Outer Sheath/Jacket *. Other color of Jacket is available

Item Code

No. of core and size

Max. dia of wire

Max. Nominal Nominal Approx. Approx. conductor Insulation thickness Overall weight of resistance cable thickness of Sheath diameter at 20 C mm 0.9 1.0 mm 2.0 2.0 mm 11.8 13.0 kg/km 173 223 /km 8.21 5.09

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 800 32 700 44

DSRN0000002205FC DSRN0000002004FC

2 x 2,5 mm 2 x 4 mm

0.26 0.31

PVC/Nylon 600 V In compliance to FAA Specification for L-846, AC 150/5345-7E

Construction : 1. Round Stranded Copper Conductor 2. Extruded PVC Insulation (85 o C) 3. Extruded Nylon Outer Sheath/Jacket, Melting point 185 o C *. Other color of Jacket is available

Item Code

No. of core and size

Max. Conducto Nominal Nominal Approx. Approx. conductor r number Insulation thickness Overall weight of resistance cable of wire thickness of Sheath diameter at 20 C 7 mm 0.51 mm 0.3 mm 4.2 kg/km 51 /km 4.61

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 30 47

DPVCNYLON01004MC

1 x 4 mm

Page: 7

TOGETHER WE GROW

PT JEMBO CABLE COMPANY Tbk.


Schedule of Technical Data I/N : AFC00000002205MA

AIRFIELD LIGHTING FLAT SECONDARY CABLE 2 x 2.5 mm 250 V Ref. Specification : AS 1125

1 2 3

1 Round Stranded Annealed Copper Wires 2 Extruded PVC Insulation 3 Extruded Nylon 12 (Black Color) Outer Sheath

Cable Construction 1 Conductor Number of wire Approximate outer diameter 2 Insulation Colour Nominal Thickness Minimum Thickness 3 Outer Sheath Nominal Thickness Tolerance of overall diameter Cable Marking by Ink Jet printing AS 1125 Minimum Bending radius Approximate Weight of Cable Electrical Characteristic 1 Max. DC Conductor Resistance at 20C 2 AC Voltage Test 3 Min. Insulation resistance at 20 C Packing 1 Type of Packing 2 Standard Length 3 Approximate Dimension of Drum 4 Approximate Net Weight 5 Approximate Gross Weight : : : : : Wooden Drum 1000 74 96 m kg kg 630mmx410mm : : : 7.410 2 50 Ohm/km kV / 5 min Meg.Ohm.km : : : : : : : : : : : 250 V " Length Marking " Round Stranded Annealed Copper Wires 7 2.01 mm Extruded PVC Black, White 0.6 0.44 0.4 1 mm mm mm mm

Extruded Nylon 12 (Black Color) 7.3 x 4 mm

Approx Overall Diameter (mayor x minor) :

JEMBO CABLE AIRFIELD LIGHTING FLAT CABLE 2 x 2.5 mm : : 48 0.07 mm kg/m

Page: 8

TOGETHER WE GROW

PT JEMBO CABLE COMPANY Tbk.


Schedule of Technical Data I/N : AFC00000002205FA

AIRFIELD LIGHTING FLAT SECONDARY CABLE 2 x 2.5 mm 250 V Ref. Specification : AS 1125

1 2

1 Round Bunched Annealed Copper Wires, Class 5 2 Extruded PVC Insulation 3 Extruded Nylon 12 (Black Color) Outer Sheath

Cable Construction 1 Conductor Number of wire Approximate outer diameter 2 Insulation Colour Nominal Thickness Minimum Thickness 3 Outer Sheath Nominal Thickness Approx Overall Diameter (mayor x minor) Tolerance of overall diameter Cable Marking by Ink Jet printing AS 1125 Minimum Bending radius Approximate Weight of Cable Electrical Characteristic 1 Max. DC Conductor Resistance at 20C 2 AC Voltage Test 3 Min. Insulation resistance at 20 C Packing 1 Type of Packing 2 Standard Length 3 Approximate Dimension of Drum 4 Approximate Net Weight 5 Approximate Gross Weight : : : : : Wooden Drum 1000 72 94 m kg kg 630mmx410mm : : : 7.410 2 50 Ohm/km kV / 5 min Meg.Ohm.km : : : : : : : : : : : : 250 V " Length Marking " Round Bunched Annealed Copper Wires, Class 5 50/0.25 2.03 mm Extruded PVC Black, White 0.6 0.44 0.4 1 mm mm mm mm

Extruded Nylon 12 (Black Color) 7.3 x 4 mm

JEMBO CABLE AIRFIELD LIGHTING FLAT CABLE 2 x 2.5 mm : : 48 0.07 mm kg/m

Page: 9

TOGETHER WE GROW

PT JEMBO CABLE COMPANY Tbk.


Schedule of Technical Data I/N : AFC10000002004MA

AIRFIELD LIGHTING FLAT SECONDARY CABLE 2 x 4 mm 600 V Ref. Specification : AS 1125

1 2 3

1 Round Stranded Annealed Copper Wires 2 Extruded PVC Insulation 3 Extruded Nylon 12 (Black Color) Outer Sheath

Cable Construction 1 Conductor Number of wire Approximate outer diameter 2 Insulation Colour Nominal Thickness Minimum Thickness 3 Outer Sheath Nominal Thickness Tolerance of overall diameter Cable Marking by Ink Jet printing AS 1125 Minimum Bending radius Approximate Weight of Cable Electrical Characteristic 1 Max. DC Conductor Resistance at 20C 2 AC Voltage Test 3 Min. Insulation resistance at 20 C Packing 1 Type of Packing 2 Standard Length 3 Approximate Dimension of Drum 4 Approximate Net Weight 5 Approximate Gross Weight : : : : : Wooden Drum 1000 116 138 m kg kg 630mmx410mm : : : 4.610 2 40 Ohm/km kV / 5 min Meg.Ohm.km : : : : : : : : : : : 600 V " Length Marking " Round Stranded Annealed Copper Wires 7 2.55 mm Extruded PVC Black, White 0.8 0.62 0.4 1 mm mm mm mm

Extruded Nylon 12 (Black Color) 9.1 x 4.9 mm

Approx Overall Diameter (mayor x minor) :

JEMBO CABLE AIRFIELD LIGHTING FLAT CABLE 2 x 4 mm : : 59 0.12 mm kg/m

Page: 10

TOGETHER WE GROW

PT JEMBO CABLE COMPANY Tbk.


Schedule of Technical Data I/N : AFC10000002006MA

AIRFIELD LIGHTING FLAT SECONDARY CABLE 2 x 6 mm 600 V Ref. Specification : AS 1125

1 2 3

1 Round Stranded Annealed Copper Wires 2 Extruded PVC Insulation 3 Extruded Nylon 12 (Black Color) Outer Sheath

Cable Construction 1 Conductor Number of wire Approximate outer diameter 2 Insulation Colour Nominal Thickness Minimum Thickness 3 Outer Sheath Nominal Thickness Tolerance of overall diameter Cable Marking by Ink Jet printing AS 1125 Minimum Bending radius Approximate Weight of Cable Electrical Characteristic 1 Max. DC Conductor Resistance at 20C 2 AC Voltage Test 3 Min. Insulation resistance at 20 C Packing 1 Type of Packing 2 Standard Length 3 Approximate Dimension of Drum 4 Approximate Net Weight 5 Approximate Gross Weight : : : : : Wooden Drum 1000 160 187 m kg kg 730mmx410mm : : : 3.080 2 30 Ohm/km kV / 5 min Meg.Ohm.km : : : : : : : : : : : 600 V " Length Marking " Round Stranded Annealed Copper Wires 7 3.12 mm Extruded PVC Black, White 0.8 0.62 0.4 1 mm mm mm mm

Extruded Nylon 12 (Black Color) 10.3 x 5.5 mm

Approx Overall Diameter (mayor x minor) :

JEMBO CABLE AIRFIELD LIGHTING FLAT CABLE 2 x 6 mm : : 66 0.16 mm kg/m

Potrebbero piacerti anche