2978

Seventh Semester B.Tech. Degree Examination, June 2009 03-701 : REFRIGERATION AND AIR CONDITIONING (M)
Time : 3 Hours Max. Marks : 100

Insturctions : 1) Use of Psychrometric chart and Refrigeration properties table permitted. 2) Answer all questions from Part A and any three questions from Part B. PART A 1. What is the difference between a heat pump and a refrigerator ? 2. Explain the concept of magnetic refrigeration. 3. Prove that COP of a Heat Pump = 1 + COP of a refrigerator. 4. What are the advantages of vapour absorption refrigeration system ? 5. Define dew point temperature and wet bulb temperature. 6. Compare vapour compression refrigeration system with air refrigeration system. 7. Discuss on bypass factor, apparatus dew point temperature and RSHF line. 8. Discuss on ozone depletion and green house effect. 9. What is an air washer ? 10. Mention the advantages and disadvantages of split type AC system. (410=40 Marks)

P.T.O.

2978

-2-

*2978*

PART B Module I 11. a) Compare reversed Carnots cycle and vapour compression cycle. b) Explain the working of a Bell-Coleman cycle air refrigeration system. 20 OR 12. a) Explain the working of a thermostatic expansion valve. b) A R22 vapour compression system operating at a condenser temperature of 45 C and an evaporator temperature of 10C has a capacity of 20 TR. Determine i) The mass flow rate of refrigerant, ii) The COP and iii) The total heat rejected at the condenser. 20 Module II 13. a) Compare vapour compression refrigeration system with vapour absorption refrigeration system. b) Explain the working of an NH3 LiBr vapour absorption refrigeration system. OR 14. a) Compare the properties of various refrigerants used. b) Explain the working of an ice-plant. 15. a) b)

20

20

16. a) b)

Module III Discuss on comfort and industrial AC. For an auditorium to be airconditioned, the room design condition is 26C DBT, 18 C WBT, the outside condition is 40 C DBT, 26 C WBT. The room sensible and latent heat are 11.1 kW and 3.9 kW respectively. The conditioned air supplied to the room contains 25% fresh air and 75% recirculated room air. Determine : i) The amount of fresh air required ii) The DBT and RH of supply air and iii) By pass factor, if ADP of cooling coil is 10C. 20 OR Discuss on summer air conditioning. Air at 20 C DBT and 18 C WBT enters a heating and humidifying apparatus, from which it leaves at 35C DBT and 30C DPT. Moisture is supplied as liquid water at 27 C to humidify the air. Find the quantity of heat that must be added per kg of air through the apparatus. 20

Potrebbero piacerti anche