Low consumption Compact HT Range

30

THAE 110119 H.T.


Heating capacity: 8.719.1 kW

Operation with outdoor air down to 15C Hot water up to 60C Standard soft-start device for models with a single-phase power supply

Packaged air-cooled reversible heat pumps for very hot water production, with axial fans. Range with hermetic Scroll compressors and R407C refrigerant gas.
Construction features
Compressor: high eciency, hermetic rotary scroll compressor complete with thermal protection, crankcase heater and soft-start device for single-phase models. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns with hydrophilic treatment, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible with Adaptive Function Plus logic, with set-point variation based on the actual thermal load. Structure: in galvanised and painted sheet steel, complete with condensation drain pan and unit base antifreeze electric heater.

TANK&PUMP unit

Pump assembly complete with: water buer tank, circulation pump or electric circulation pump, expansion tank with membrane, air bleed valves, safety valve and drain valve.

FACTORY FITTED ACCESSORIES

Soft-start device (for models with 400 V power supply, as standard for 230 V models). Silenced installation. Water buer tank antifreeze electric heater Digital input for double set-point. 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE

Models

THAE: heat pump unit.

STANDARD unit PUMP unit

Without pump assembly and water buer tank. Pump assembly complete with: circulation pump or electric circulation pump, expansion tank with membrane, manual air bleed valve and safety valve.

3-way valve for the production of hot water, managed by regulation. Additional electric heater for heat pump, managed by regulation. External air temperature probe for set-point compensation. Water lter. Antivibration rubber mountings. Remote keyboard with display. Clock card. Serial interfaces for the BMS connection or for managing the unit within the scope of a Rhoss heat pump system (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. Rhoss supervision system for unit monitoring and remote management.

Web code: C0C1

HEAT PUMP

OUTDOOR INSTALLATION

31

Heating capacity Absorbed power C.O.P. Heating capacity Absorbed power C.O.P. Heating capacity Absorbed power C.O.P. Heating capacity Absorbed power C.O.P. Cooling capacity E.E.R. E.S.E.E.R. E.S.E.E.R.+ E.S.E.E.R. + Radiant systems Heating capacity Absorbed power (*) C.O.P. C.O.P. (**) Cooling capacity Absorbed power (*) E.E.R. Sound power level \ Sound pressure level \ Silenced version sound pressure level Scroll/step compressor Water buffer tank content Electrical supply DIMENSIONS AND WEIGHTS L - Width PUMP/STANDARD L - Width TANK&PUMP H - Height PUMP/STANDARD H - Height TANK&PUMP P - Depth Weight

kW kW kW kW kW kW kW kW kW

8,70 3,15 2,76 5,70 3,10 1,84 8,46 3,82 2,21 6,17 3,56 1,73 8,50 2,86 3,45 3,82

13,84 4,60 3,01 8,83 4,46 1,98 14,04 5,49 2,56 10,20 5,50 1,85 11,10 2,39 3,51 3,89 14,26 3,44 4,14 3,76 15,80 4,40 3,59 73,0 50 46 1/1 35 61/150 230-1-50 / 400-3+N-50 113 1.230 1.522 1.090 1.090 580 217

19,10 6,30 3,03 11,35 5,57 19,84 7,33 2,71 12,90 6,46 15,50 2,39 3,25 3,61 19,70 4,17 3,91 22,00 6,25 3,52 77,6 52 49 1/1 45 60/151 400-3+N-50 119 1.230 1.522 1.280 1.280 600 267 2,00

kW kW

9,41 2,42 3,88 3,66

kW kW dB(A) dB(A) dB(A) no. l V-ph-Hz mm mm mm mm mm kg

11,20 3,21 3,49 71,0 47 45 1/1 30 37/86 230-1-50 / 400-3+N-50 110 990 990 1.085 1.295 380 189

Available nominal head pressure of circulator pump/pump kPa

TERMINAL UNITS

FAN COIL UNITS

In the following conditions: Air: 7C D.B. - 6C W.B. - Water: 40/45C. Air: -7C D.B. - Water: 45C. With the same water ow rate as condition . Air: 7C D.B. - 6C W.B. - Water: 47/55C. Air: -7C D.B. - Water: 55C. With the same water ow rate as condition . Air: 35 D.B. - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 30/35C. Air: 35 D.B. - Water: 23/18C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.

ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software. (*) Unit without circulation pump. (**) Reference for the tax credit for the French market. NB: NF PAC certication is valid for all models with hydraulic installations with a circulation pump (P0) and with a circulation pump and a water buer tank (ASP0) with the exception of model 110 with 400V power supply.

SYSTEM ACCESSORIES

CONDENSING UNITS

EXP Polyvalent systems

INDUSTRIAL & PROCESS COOLING

4,72

WATER cooled CONDENSERLESS UNITS

WATER CHILLERS HEAT PUMPS

AIR cooled CENTRIFUGAL fans

2,04

WATER CHILLERS HEAT PUMPS

AIR cooled AXIAL fans

Low temperature fan coil/radiator systems

WATER CHILLERS HEAT PUMPS

THAE H.T. MODEL

110

113

119

Potrebbero piacerti anche