Methodology The alarm analysis is based on alarm history taken from 24th to 28th of March.

The analysis is done per RNC sorting out the count of BFD alarms in descending order.

For internal use only 1 Nokia Siemens Networks

Introduction
Fault reason Remote node transmission error. (i.e. RNC=Local WBTS=Remote) Description The alarm is raised if the BFD service is not available anymore on the BTS. In case only 1 BFD session is configured and activated, the alarm is raised if BFD on this session fails in either ingress or egress direction Instructions 1. Check if the far end has BFD switched on. 2. Check cabling and network connections to the far end.

For internal use only 2 Nokia Siemens Networks

RNC-301(MB1)
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution Fixing the Transmission

For internal use only 3 Nokia Siemens Networks

RNC-301(MB1) Continued
At total of 5 sites are affected in MB1 RNC for the past 4 days from 24th to 28th March 2013 At total of 11 BFD Alarms were triggered

For internal use only 4 Nokia Siemens Networks

RNC-401(MW1)
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution
Fixing the Transmission

For internal use only 5 Nokia Siemens Networks

RNC-401(MW1) Continued
At total of 40 sites are affected in MW1 RNC for the past 4 days from 24th to 28th March 2013 At total of 444 BFD Alarms were triggered per RNC

For internal use only 6 Nokia Siemens Networks

RNC-501(AR1)
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution
Fixing the Transmission

For internal use only 7 Nokia Siemens Networks

RNC-501(AR1) Continued
At total of 23 sites are affected in AR1 RNC for the past 4 days from 24th to 28th March 2013 At total of 494 BFD Alarms were triggered per RNC

For internal use only 8 Nokia Siemens Networks

RNC-601(DA1)
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution
Fixing the Transmission

For internal use only 9 Nokia Siemens Networks

RNC-601(DA1) Continued
At total of 29 sites are affected in DA1 RNC for the past 4 days from 24th to 28th March 2013 At total of 8315 BFD Alarms were triggered per RNC

For internal use only 10 Nokia Siemens Networks

RNC-611(DA2)
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution
Fixing the Transmission

For internal use only 11 Nokia Siemens Networks

RNC-611(DA2) Continued
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution
Fixing the Transmission

For internal use only 12 Nokia Siemens Networks

RNC-611(DA2) Continued
At total of 215 sites are affected in DA2 RNC for the past 4 days from 24th to 28th March 2013 At total of 41625 BFD Alarms were triggered per RNC

For internal use only 13 Nokia Siemens Networks

RNC-621(DA3)
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution
Fixing the Transmission

For internal use only 14 Nokia Siemens Networks

RNC-621(DA3) Continued
At total of 101 sites are affected in DA3 RNC for the past 4 days from 24th to 28th March 2013 At total of 30843 BFD Alarms were triggered per RNC

For internal use only 15 Nokia Siemens Networks

RNC-702(DO2)
Problem
BFD Down Alarms count is High

Cause
Poor/unstable Transmission link as indicated by BDF Failure alarms on BTS. This is typically a transmission issue

Proposed Resolution
Fixing the Transmission

For internal use only 16 Nokia Siemens Networks

RNC-702(DO2) Continued
At total of 53 sites are affected in DO2 RNC for the past 4 days from 24th to 28th March 2013 At total of 806 BFD Alarms were triggered per RNC

For internal use only 17 Nokia Siemens Networks

In Summary

For internal use only 18 Nokia Siemens Networks

In Summary

For internal use only 19 Nokia Siemens Networks

Conclusion
Problem Cause
Proposed Resolution

BFD Down Poor/unstable Transmission link Alarms as indicated by BDF Failure count is alarms on BTS. High This is typically a transmission issue

Fixing the Transmission will resolve most of the network Problems