Sei sulla pagina 1di 6

N-17000-6

CONDENSER THERMODYNAMIC CALCULATION N369.00J

HARBIN TURBINE CO.LTD PEOPLES REPUBLIC OF CHINA


2008

N-17000-6

CONDENSER THERMODYNAMIC CALCULATION N369.00J

DES CHECK AUDIT APP TECH


2008.3

vwo
NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

condition
name main exhaust flow main exhaust enthalpy assistant exhaust flow symbol Gk1 ik1 Gk2 formula & source known known known known known known Gk=Gk1+Gk2 ik= Gk1.ik1+Gk2.ik2)/ Gk Consult table Selected tk=tn-tn Selected W=Gk.m Consult table Consult table t=(ik-tk)/m/Cp t2=t1+t t=tn-t2 tcp=t/ln((tkt1)/(tk-t2)) Selected CT1 Selected t/h kJ/(kg*) kg/m
3

unit t/h kJ/kg t/h kJ/kg MPa t/h kJ/kg

value 691.1 2376.2 0 0 0.0097 33 691.1 2376.2 45.24 0.5 44.74 74.69 51618.259 0.957 1019 7.314183467 40.31418347 4.925816533 7.497520134 TA 0.06

assistant exhaust enthalpy ik2 back pressure circulating water temp.at waterbox inlet total exhaust flow total exhaust enthalpy Saturation temp. of condenser super_cooling value condensate temp. circulating factor circulating water flow circulating specific heat circulating density circulating water temp. rise pk t1 Gk ik tn tn tk m W Cp t

circulating water temp. at t2 waterbox outlet Temp. difference in heat t transfer end Log. even temp difference Material of cooling tube rate of tubes in air cooling zone tcp

design condition--Tmcr
NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 name main exhaust flow main exhaust enthalpy assistant exhaust flow symbol Gk1 ik1 Gk2 formula & source known known known known known known Gk=Gk1+Gk2 ik= Gk1.ik1+Gk2.ik2)/ Gk Consult table Selected tk=tn-tn Selected W=Gk.m Consult table Consult table t=(ik-tk)/m/Cp t2=t1+t t=tn-t2 tcp=t/ln((tkt1)/(tk-t2)) Selected CT1 Selected t/h kJ/(kg*) kg/m3 unit t/h kJ/kg t/h kJ/kg MPa t/h kJ/kg value 660.95 2382.2 0 0 0.0097 33 660.95 2382.2 45.24 0.5 44.74 78 51554.1 0.957 1019 7.022997816 40.02299782 5.217002184 7.702105159 TA 0.06

assistant exhaust enthalp ik2 back pressure circulating water temp.at waterbox inlet total exhaust flow total exhaust enthalpy pk t1 Gk ik

Saturation temp. of condenser tn super_cooling value condensate temp. circulating factor circulating water flow circulating specific heat circulating density circulating water temp. rise tn tk m W Cp t

circulating water temp. t2 at waterbox outlet Temp. difference in heat transfer end Log. even temp difference Material of cooling tube rate of tubes in air cooling zone t tcp

NO. 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

name thickness of tubes wall in air cooling zone rate of tubes in condensing zone thickness of tubes wall in condensing zone rate of tubes in againsting steam zone thickness of tubes wall in againsting steam zone average thickness of tube wall Tube O.D Flow of cooling water Velocity of cooling water Cleanliness factor

symbol TH1 CT2 TH2 CT3 TH3 dn Z V

formula & source Selected Selected Selected Selected Selected =CT1*TH1+CT2*TH2+CT 3*TH3 Selected Selected Selected Selected Consult table Consult table Consult table

unit mm

value 0.7 0.87

mm

0.5 0.07

mm mm mm m3/s

0.7 0.526 31.75 2 2.2 0.85 1.079 0.946

temp. correction factor t Tube material correction facto m Coefficient General heat-transfer factor Cooling area Actual cooling area Quantity of cooling tubes C K F' F N'

Kcal/m2.h.

2291 2948.274637 15258.79718 17000 17261.72373 17616 9674.942314

K=C.V0.5..t.Kcal/m2.h. F'=Gk(ik-tk)/K/tcp Selected N'=WZ10000000/(9 3.14(dn -2)2 V) Selected L=F*1000000/ (3.14* dn *N) m2 m2 Ea Ea mm

Actual quantity of cooling tub N Effective length of actual cooling tube L

NO. 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

name

symbol

formula & source Selected Selected Selected Selected Selected =CT1*TH1+CT2*TH2+CT 3*TH3 Selected Selected Selected Selected Consult table Consult table Consult table K=C.V
0.5

unit mm

value 0.7 0.87

thickness of tubes wall in TH1 air cooling zone rate of tubes in CT2 condensing zone thickness of tubes wall in TH2 condensing zone rate of tubes in CT3 againsting steam zone thickness of tubes wall in TH3 againsting steam zone average thickness of tube wall Tube O.D Flow of cooling water Velocity of cooling water Cleanliness factor temp. correction factor Tube material correction factor Coefficient General heat-transfer factor Cooling area Actual cooling area Quantity of cooling tubes dn Z V t m C K F' F N'

mm

0.5 0.07

mm mm mm
3 m /s

0.7 0.526 31.75 2 2.2 0.85 1.079 0.946

Kcal/m2.h. Kcal/m2.h. ..t. m m


2

2291 2948.274637 16345.40038 17000 17283.20592 17616 9674.942314

F'=Gk(ik-tk)/K/tcp Selected N'=WZ 10000000/(93.14 (dn -2)2V Selected L=F*1000000/ (3.14* dn *N)

Ea Ea mm

Actual quantity of cooling tubes N Effective length of actual L cooling tube