Sei sulla pagina 1di 26

Hilti HIT-HY 70

Hilti HIT-HY 70 injection mortar for masonry


Injection mortar system
Hilti HITHY 70 330 ml foil pack (also available as 500 ml and 1400 ml foil pack) Mixer HIT-V rod HAS, HAS-E rod HIT-AC, HITACR rod HIT-AN rod HIT-IG internal threaded sleeve HIT-IC internal threaded sleeve HIS-RN sleeve HIT-SC composite sleeve

Benefits
- chemical injection fastening for all type of base materials: - hollow and solid - clay bricks, sand-lime bricks, normal and light weight concrete blocks, aerated light weight concrete, natural stones - two-component hybrid mortar - rapid curing - versatile and convenient handling - flexible setting depth and fastening thickness - small edge distance and anchor spacing - mortar filling control with HIT-SC sleeves - suitable for overhead fastenings - in-service temperatures: short term: max.120C long term: max 72C

HCR
Concrete Variable embedment depth Solid brick Hollow brick Autoclaved aerated concrete Fire resistance Corrosion resistance High corrosion resistant Hilti anchor design software

Approvals / certificates
Description Allgemeine bauaufsichtliche Zulassung (national German approval) Fiche technique SOCOTEC a) Fire test report Assessment report (fire) Authority / Laboratory DIBt, Berlin SOCOTEC, Paris MFPA, Leipzig warringtonfire No. / date of issue Z-21.3-1830 / 2009-01-20 YX 0047 08.2006 PB III/B-07-157 / 2007-06-04 WF 166402 / 2007-10-26
06 / 2011

646

Hilti HIT-HY 70

Basic loading data (for a single anchor)


x x x x x x All data in the table below applies to Load values valid for holes drilled with TE rotary hammers in hammering mode Correct anchor setting (see instruction for use, setting details) Steel quality of fastening elements: see data below Steel quality for screws for HIT-IG, HIT-IC and HIS-N: min. grade 5.8 / HIS-RN: A4-70 Threaded rods of appropriate size (diameter and length) and a minimum steel quality of 5.6 can be used Base material temperature during installation and curing must be between -5C through +40C (Exception: solid clay bricks (e.g. Mz12): +5C till 40C)

Recommended loads a) Frec for brick breakout and pull out in [kN] Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Solid clay brick Mz12/2,0 DIN 105/ EN 771-1 fb b) t 12 N/mm 80 Nrec [kN] Germany, Austria, Switzerland Solid sandlime brick KS 12/2,0 DIN 106/ EN 771-2 fb b) t12 N/mm Vrec [kN] 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) 3,0 c) Setting depth [mm] Nrec [kN] Vrec [kN] M6 M8 M10 M12 M8 M10 M12

HIT-IG / HIT-IC

1,0 1,0

1,7 1,7

1,7 1,7

1,7 1,7

1,7 1,7

1,7 1,7

Nrec [kN]

1,0

1,7

1,7

1,7

1,7

1,7

Vrec [kN] 80 Nrec [kN]

1,0 3,0 d)

1,7 3,0 d)

1,7 3,0 d)

1,7 3,0 d)

1,7 3,0 d)

1,7 3,0 d)

Germany, Austria, Vrec [kN] 3,0 d) 3,0 d) 3,0 d) 3,0 d) 3,0 d) 3,0 d) Switzerland a) Recommended load values for German base materials are based on national regulations. b) fb = brick strength c) Values only valid for Mz (DIN 105) with brick strength t 29 N/mm, density 2,0 kg/dm, minimum brick size NF (24,0cm x 11,5cm x 7,1cm), not covered by national German approval Z-21.3-1830 / 2009-01-20 d) Values only valid for KS (DIN 106) with brick strength t 23 N/mm, density 2,0 kg/dm, minimum brick size NF (24,0cm x 11,5cm x 7,1cm), not covered by national German approval Z-21.3-1830 / 2009-01-20

06 / 2011

647

Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN] Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Aerated concrete PPW 2-0,4 DIN 4165/ EN 771-4 fb b) t 2 N/mm Setting depth [mm] M6 M8 M10 M12 M8 M10 M12

HIT-IG / HIT-IC

Nrec [kN]

0,5

0,6

0,6

0,6

0,6

0,6

80

Germany, Austria, Switzerland

Vrec [kN]

0,1

0,1

0,2

0,2

0,4

0,4

Lightweight concrete acc. Nrec [kN] 1,0 1,0 1,5 1,5 1,5 TGL (haufwerks80 poriger Leichtbeton), Vrec [kN] 1,0 1,0 1,5 1,5 1,5 Germany a) Recommended load values for German base materials are based on national regulations. b) fb = brick strength

1,5

1,5

648

06 / 2011

Hilti HIT-HY 70

Basic loading data (for a single anchor)


All data in the table below applies to x Load values valid for holes drilled with TE rotary hammers in sensitive hammering mode x Correct anchor setting (see instruction for use, setting details) x Steel quality of fastening elements: see data above; x Steel quality for screws for HIT-IG: min. grade 5.8 x Threaded rods of appropriate size (diameter and length) and a minimum steel quality of 5.6 can be used

Recommended loads a) Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Setting depth [mm] 50 80 100 Germany, Austria, Switzerland 130 160 Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18x c) 22x 22x 0,3 0,3 0,6 0,6 0,4 0,4 0,8 0,8 0,8 0,8 0,84 0,8 0,91 0,8 0,8 0,8 1,0 1,0 1,54 1,4 1,68 1,4 1,82 0,4 0,4 0,8 0,8 0,8 0,8 0,84 0,8 0,91 0,8 0,8 0,8 1,0 1,0 1,54 1,4 1,68 1,4 1,82 0,8 0,4 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 1,0 1,0 1,54 1,4 1,54 1,4 1,54 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 1,0 1,0 1,54 1,4 1,54 1,4 1,54 0,8 0,8 1,0 1,0 0,8 0,8 1,0 1,0 0,8 0,8 1,0 1,0 0,8 0,8 1,0 1,0 -

HlzB 6 DIN 105/ EN 771-1 fb b) t 6 N/mm

Hlz 12 DIN 105/ EN 771-1 fb b) t12 N/mm

50 80 100

Germany, Austria, Switzerland a) b) c)

130 160

Vrec [kN] 1,4 1,4 1,4 1,4 Recommended load values for German base materials are based on national regulations. fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

06 / 2011

649

Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Setting depth [mm] 50 KSL 12 DIN 106/ EN 771-2 fb b) t 12 N/mm 80 100 Germany, Austria, Switzerland 130 160 Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18x c) 22x 22x 0,5 0,5 0,7 0,7 1,4 1,4 1,4 1,4 1,44 1,4 1,56 0,7 0,7 1,4 1,4 1,4 1,4 1,44 1,4 1,56 0,7 0,7 1,4 1,4 1,4 1,4 1,4 1,4 1,4 0,7 0,7 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,0 1,0 1,0 1,0 -

a) b) c)

Vrec [kN] 1,4 1,4 1,4 1,4 Recommended load values for German base materials are based on national regulations. fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

650

06 / 2011

Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Setting depth [mm] 50 Hbl 2 DIN 18 151/ EN 771-3 fb b) t 2 N/mm 80 100 Germany, Austria, Switzerland 130 160 Hbl 4 DIN 18 151/ EN 771-3 fb b) t 4 N/mm Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] Germany, Austria, Switzerland Hbn 4 DIN 18 153/ EN 771-3 fb b) t 4 N/mm 80 Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] 0,4 0,6 0,8 0,6 0,8 0,6 0,8 0,6 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,4 0,8 0,6 0,8 0,6 0,8 0,6 0,8 0,6 0,8 0,8 0,8 0,8 0,4 0,6 0,8 0,6 0,8 0,6 0,8 0,6 0,8 0,8 0,8 0,8 0,8 M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18x c) 22x 22x 0,3 0,3 0,4 0,5 0,5 0,5 0,5 0,7 0.6 0.72 0,6 0,78 0,6 0,6 0,5 0,5 0,5 0,5 0,7 0.6 0.72 0,6 0,78 0,6 0,6 0,5 0,5 0,5 0,5 0,7 0.6 0,7 0,6 0,7 0,6 0,6 0,5 0,5 0,5 0,5 0,7 0.6 0,7 0,6 0,7 0,6 0,6 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 -

80 Germany, Austria, Vrec [kN] 0,8 0,8 0,8 0,8 0,8 0,8 Switzerland a) Recommended load values for German base materials are based on national regulations. b) fb = brick strength c) HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

06 / 2011

651

Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Brique creuse C40 NF-P 13-301/ EN 771-1 fb b) t 4 N/mm Setting depth [mm] 80 100 130 France 160 Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] M6 M8 M10 M12 M8

HIT-IC / HIT-IG c)
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18x d) 22x 22x 0,5 1,0 0,5 1,0 0,5 1,0 0,5 1,0 0,7 1,5 0,7 1,5 0,7 1,5 0,7 1,5 0,5 1,0 0,5 1,0 0,5 1,0 0,5 1,0 0,7 1,5 0,7 1,5 1,2 1,7 1,2 1,7 0,5 1,0 0,5 1,0 0,5 1,0 0,5 1,0 0,7 1,5 0,7 1,5 1,2 1,7 1,2 1,7 0,5 1,0 0,5 1,0 0,5 1,0 0,5 1,0 0,7 1,5 0,7 1,5 1,2 1,7 1,2 1,9 0,5 1,0 0,7 1,5 0,5 1,0 0,7 1,5 0,5 1,0 0,7 1,5 0,5 1,0 0,7 1,5 -

Parpaing creux B40 NF-P 14-301/ EN 771-3 fb b) t 4 N/mm

80

100

130 France a) b) c) d)

160

Recommended load values for French base materials are based on national regulations. fb = brick strength HIT-IG not covered by national French approval XY 0047 06.2009 HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

652

06 / 2011

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC Values in brackets: mean ultimate loads Fu,m [kN]: HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Setting depth [mm] 50 Mattone Alveolater 50 EN 771-1 fb b)t 16 N/mm 80 100 Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] 160 Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Doppio uni EN 771-1 fb b)t 27 N/mm Nrec [kN] 80 Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] 160 Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] 100 Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] 160 a) b) c) Nrec [kN] Vrec [kN] M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x 0,9 (4,2) 1,2 (5,8) 1,1 (5,0) 1,2 (5,3) 0,65 (2,9) 1,3 (5,7) 1,0 (5,0) 1,3 (6,1) 0,6 (2,7) 0,9 1,1 1,2 1,5 1,2 1,5 1,2 2,3 (10,4) 1,2 2,3 1,2 0,65 1,3 1,0 1,9 1,0 1,9 2,0 1,9 2,0 1,9 0,7 (3,3) 0,9 0,7 0,9 1,5 (6,7) 0,9 1,5 (7,3) 0,9 1,1 (4,9) 1,2 1,5 1,2 1,5 1,2 2,3 1,2 2,3 1,2 0,65 1,3 (6,6) 1,0 (6,8) 1,9 (8,5) 1,0 1,9 2,0 (12,1) 1,9 2,0 1,9 0,7 0,9 0,7 0,9 1,5 0,9 1,5 0,9 1,25 1,2 1,7 1,2 1,7 1,2 2,8 1,2 2,8 1,2 0,65 1,3 1,0 1,9 1,0 1,9 2,0 1,9 2,0 1,9 1,0 0,9 1,0 0,9 1,9 0,9 1,5 1,0 1,25 (5,7) 2,0 (10,2) 1,7 2,0 1,7 2,0 2,8 (12,7) 2,0 2,8 (13,8) 2,0 0,65 (2,9) 1,3 (6,0) 1,0 2,0 (11,0) 1,0 2,0 2,0 (9,0) 2,0 2,0 2,0 1,0 1,0 1,0 1,0 1,9 (9,8) 1,0 1,9 (8,8) 1,0 1,5 (7,0) 1,2 1,0 1,9 0,7 0,9 1,7 1,2 1,0 1,9 1,0 0,9 1,0 2,0 1,0 1,0 1,0 (4,5) 2,0 1,0 (5,2) 1,0 1,7 2,0 1,7 2,0 -

130 Italy

50

100 Italy

130

80 Foratino 4 Fori EN 771-1 fb b)t 7 N/mm

130 Italy

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

06 / 2011

653

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC Values in brackets: mean ultimate loads Fu,m [kN]: HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Mattone rosso EN 771-1 fb b) t 26 N/mm Setting depth [mm] Nrec [kN] 50 Vrec [kN] Nrec [kN] Italy Blocchi cem 2 Fori EN 771-3 fb b) t 8 N/mm 80 Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Italy a) b) c) Vrec [kN] 1,5 (7,1) 2,0 2,0 2,0 2,0 (20,0) 2,0 2,0 2,0 2,0 Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit. 1,5 (7,2) 1,5 1,5 1,25 1,5 1,25 2,0 (14,6) 1,25 (5,6) 1,25 1,25 1,25 (5,6) 1,25 M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x 0,35 (1,7) 0,5 (2,9) 0,45 0,5 (2,1) 0,45 (2,0) 0,5 (3,3) 1,25 0,45 0,6 1,25 0,45 0,6 (3,0) 1,25 (7,5) 0,5 0,6 0,6 (4,2) 0,6 -

1,0 (5,8) 1,25 (6,6)

1,0 (4,6) 1,25 (6,8)

Recommended loads a) Frec for brick breakout and pull out in [kN] Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC HIT-AC, HIT-V, HAS, HAS-E or Rebar c)
Anchor size Base material Setting depth [mm] 80 Volcanic rock (Tufo) EN 771-3 fb b) t 4,3 N/mm 100 120 140 160 a) b) c) d) Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Nrec [kN] Vrec [kN] Rod M8 or Rebar 8 d) 0,9 0,9 Rod M10 or Rebar 10 d) 1,2 1,2 Rod M12 or Rebar 12 d) 1,5 1,5 Rod M14 or Rebar 14 d) 1,8 1,8 Rod M16 or Rebar 16 d) 2,1 2,1

Italy

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength Minimum base material thickness h = setting depth + 50mm. Drill bit diameters for rebars BSt 500S:
06 / 2011

654

Hilti HIT-HY 70

8: d0=12mm; 10: d0=14mm; 12: d0=16mm; 14: d0=18mm; 16: d0=20mm;

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC Values in brackets: mean ultimate loads Fu,m [kN]: HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Hueco doble EN 771-1 b) fb t 4 N/mm Setting depth [mm] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Spain Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] Spain 80 Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Spain Clinker mediterraneo EN 771-1 b) fb t 78 N/mm Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Spain a) b) c) Vrec [kN] 1,5 0,7 (3,3) 1,5 (6,4) 0,7 1,4 (6,4) M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x 0,5 (2,6) 0,9 (4,2) 0,7 (3,1) 1,0 (4,8) 0,5 (3,1) 1,2 (5,5) 0,5 (2,4) 1,2 (5,6) 0,8 (4,5) 1,5 (6,9) 0,8 0,5 (2,0) 0,9 0,9 (3,8) 1,0 (4,5) 0,7 1,2 1,1 (5,2) 1,2 0,8 (3,6) 1,6 (8,6) 1,9 2,0 (12,4) 0,7 (3,1) 1,6 (7,8) 1,8 (8,0) 2,0 (9,5) 0,5 (2,4) 0,9 0,9 (4,0) 1,0 0,7 1,2 1,1 1,2 0,8 1,6 1,9 2,0 0,7 1,6 1,8 2,0 0,5 0,9 1,1 1,0 0,7 1,2 1,3 1,2 0,8 1,6 2,3 2,0 0,7 1,6 2,1 2,0 0,5 0,9 (4,4) 1,1 (5,0) 1,7 (7,8) 0,7 (3,2) 1,9 (8,6) 1,3 2,0 (10,8) 0,8 1,6 2,3 2,0 (17,4) 0,7 1,6 (0,7) 2,1 2,0 (16,3) 1,9 (8,5) 2,0 1,8 (8,3) 2,0 (14,4) 2,3 2,0 2,1 2,0 2,3 2,0 2,1 2,0 2,3 (10,4) 2,0 2,1 (9,7) 2,0 0,9 (4,0) 1,0 1,1 1,2 1,1 1,0 1,3 1,2 1,3 (5,8) 2,0 1,3 2,0 1,1 (6,3) 1,7 1,1 1,7 -

Termoarcilla EN 771-1 fb b)t 22 N/mm

Ladrillo cara vista EN 771-1 fb b)t 42 N/mm

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

06 / 2011

655

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Concrete Block EN 771-3 fb b) t 7,0 N/mm L x H x B [mm] 440 x 215 x 215 Setting depth [mm] Nrec [kN] 50 Vrec [kN] 1,0 1,6 2,0 2,0 2,0 M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x

0,3

0,8

1,1

2,0

2,0

Nrec [kN] (Shell thickness 48 mm) Great Britain Concrete Block EN 771-3 b) fb t 7 N/mm L x H x B [mm] 440 x 215 x 138 (Shell thickness 48 mm) Great Britain 80 Vrec [kN]

0,3

0,8

1,1

2,0

2,0

1,0

1,6

2,0

2,0

2,0

Nrec [kN] 50 Vrec [kN]

0,4

0,6

0,7

1,5

1,5

0,9

1,7

1,7

1,7

1,7

Nrec [kN] 80 Vrec [kN]

0,4

0,6

0,7

1,5

1,5

0,9

1,7

1,7

1,7

1,7

Concrete Block EN 771-3 fb b) t 7 N/mm L x H x B [mm] 440 x 215 x 112 50 (Shell thickness 48 mm) Great Britain a) b) c)

Nrec [kN]

0,5

0,8

0,9

0,9

0,9

Vrec [kN]

1,1

1,3

1,3

1,3

2,0

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

656

06 / 2011

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Dense Concrete EN 771-3 fb b) t 14 N/mm L x H x B [mm] 440 x 215 x 100 Setting depth [mm] M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x

Nrec [kN] 50 Vrec [kN]

1,5

2,5

2,5

2,5

2,5

1,3

2,5

2,5

2,5

3,0

Great Britain Dense Concrete EN 771-3 fb b) t 14 N/mm L x H x B [mm] 440 x 215 x 140 Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Great Britain Thermalite/ Celcon EN 771-3 fb b) t 6 N/mm L x H x B [mm] 440 x 100 x 215 Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Great Britain Nostell Red Multi EN 771-3 fb b) t 70 N/mm L x H x B [mm] 215 x 102 x 65 Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Great Britain a) b) c) Vrec [kN] 1,5 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 1,5 1,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,5 3,0 3,5 3,5 3,5 0,9 1,0 1,0 2,0 1,0 2,0 1,0 2,0 1,2 2,5 1,0 1,0 1,2 1,2 0,5 1,3 0,6 1,5 0,6 1,5 0,6 1,7 0,9 1,7 1,5 1,7 1,7 1,7 1,3 0,7 2,5 0,8 2,5 0,8 2,5 0,8 3,0 0,8 2,5 2,5 3,0 3,0 1,3 1,5 2,5 3,0 2,5 3,0 2,5 3,0 3,0 4,0 3,0 3,0 3,0 4,0 1,5 2,5 2,5 2,5 2,5

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

06 / 2011

657

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material London yellow Multi Stock EN 771-3 fb b) t 16 N/mm L x H x B [mm] 215 x 100 x 65 Setting depth [mm] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Great Britain a) b) c) Vrec [kN] 1,4 2,5 2,5 2,5 3,0 2,5 2,5 3,0 3,0 1,4 2,0 1,9 3,0 1,9 3,0 1,9 3,0 2,5 4,0 3,0 3,0 3,0 4,0 M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x 1,0 1,3 1,3 1,7 1,7 -

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

Recommended loads a) Frec for brick breakout and/or pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Dense Concrete EN 771-3 fb b)t 14 N/mm L x H x B [mm] 440 x 215 x 100 Setting Base depth material [mm] M6 M8 M10 M12 M8 M10 M12

HIT-IG / HIT-IC

Nrec [kN] 80 Vrec [kN]

2,5

2,5

2,5

2,5

2,5

3,0

Great Britain Dense Concrete EN 771-3 fb b) t 14 N/mm L x H x B [mm] 440 x 215 x 140

Nrec [kN] 80 Vrec [kN]

3,5 c)

4,0 c)

4,5 c)

2,5

2,5

3,0

Great Britain a) b) c) Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb brick strength The minimum value of brick break out and/or pull out given in the table and of pull out of one brick is decisive.

658

06 / 2011

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Fire light brick Scoria Blend fb b) t 16 N/mm L x H x B [mm] 230 x 110 x 119 Setting depth [mm] Nrec [kN] 50 Vrec [kN] Nrec [kN] (Shell thickness 19 mm) Australia Hollow Block fb b)t 15 N/mm L x H x B [mm] 390 x 190 x 190 80 Vrec [kN] 1,25 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 1,0 1,5 1,5 1,5 2,0 M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x 0,5 0,5 0,5 0,8 0,8 -

1,8

1,8

1,8

1,8

1,8

1,8

1,8

1,8

1,8

Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Vrec [kN]

0,6

0,6

0,6

0,6

0,6

1,0

1,5

1,5

1,5

2,0

(Shell thickness 30 mm) Australia

0,6

0,9

0,9

1,7

1,7

0,9

1,7

1,7

1,7

1,25

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

Clay common (Standard) fb b)t 84 N/mm L x H x B [mm] 230 x 110 x 76

Nrec [kN] 50 Vrec [kN] Nrec [kN]

1,5

1,5

1,5

1,5

1,5

2,0

2,0

2,0

2,0

2,0

2,0

3,0

3,0

3,0

4,0

3,0

4,0

4,0

4,0

(Shell thickness 20 mm) Australia a) b) c)

80 Vrec [kN] 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

06 / 2011

659

Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN] Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Setting depth [mm] M6 M8 M10 M12 M8 M10 M12

HIT-IG / HIT-IC

Clay common (Dry pressed) fb b) t 25 N/mm L x H x B [mm] 230 x 110 x 76

Nrec [kN] 80 Vrec [kN]

2,5

3,0

4,0

2,5

3,0

4,0

2,0

2,0

2,0

2,0

2,0

2,0

Australia

Calduran Solid sand-lime brick fb b) t 22 N/mm L x H x B [mm] 437x198x100

Nrec [kN] 80 Vrec [kN]

2,5 c)

3,0 c)

3,0 c)

3,0 c)

4,0 c)

3,0

4,0

3,0

3,0

4,0

Netherlands Calduran Solid sand-lime brick fb b) t 22 N/mm L x H x B [mm] 437x298x215

Nrec [kN] 80 Vrec [kN]

2,5 c)

3,0 c)

3,0 c)

3,0 c)

4,0 c)

3,0

4,0

3,0

3,0

4,0

Netherlands a) b) c) Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength The minimum value of brick break out and/or pull out given in the table and of pull out of one brick is decisive.

660

06 / 2011

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Wienerberger Powerbrick b) fb t 41 N/mm L x H x B [mm] 285x135x135 Setting depth [mm] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Belgium Wienerberger Thermobrick fb b) t 21 N/mm L x H x B [mm] 285x135x138 Vrec [kN] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Belgium Concrete hollow brick fb b) t 6 N/mm L x H x B [mm] 600x500x92 Vrec [kN] 1,5 2,0 2,0 2,0 2,5 2,0 2,0 2,5 2,5 1,0 1,5 1,25 1,75 1,25 1,75 1,25 1,75 1,5 1,75 1,75 1,75 1,75 1,75 1,5 0,5 3,0 0,75 3,0 0,75 3,0 1,0 4,0 1,0 3,0 3,0 4,0 4,0 1,5 1,5 2,0 1,75 2,0 1,75 2,0 2,0 3,0 2,0 1,75 2,0 2,0 2,0 M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x 1,0 1,25 1,25 1,25 1,25 -

Nrec [kN] 50 Vrec [kN]

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,75

0,75

0,75

1,0

0,75

0,75

1,0

1,0

(Shell thickness 15 mm) Finland Leca typ 3 EN 771-3 fb t 3,0 N/mm 80 Vrec [kN] 1,2 1,2 1,2 2,0 1,2 1,2 2,0 2,0

Nrec [kN]

2,0

2,0

2,0

2,0

2,0

2,0

2,0

2,0

Sweden a) b) c)

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.

06 / 2011

661

Hilti HIT-HY 70

Recommended loads Frec for brick breakout and pull out in [kN]: Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC Values in brackets: mean ultimate loads Fu,m [kN]: HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Concrete block fb b) t 23 N/mm L x H x B [mm] 390 x 190 x 120 Setting depth [mm] Nrec [kN] 50 Vrec [kN] Nrec [kN] (Shell thickness 25 mm) Japan Spancrete (Hollow Core Slab) fb b) t 83 N/mm L x H x B [mm] 1000 x1000 x125 80 Vrec [kN] 1,25 (7,1) 1,5 1,5 1,5 2,0 1,5 (11,4) 1,5 2,0 2,0 (15,9) 1,25 (6,7) 1,25 (9,0) 1,5 (11,4) 1,5 (10,3) 1,5 1,5 2,0 (17,2) 2,0 1,5 (9,2) 2,0 2,0 2,0 (12,1) M6 M8 M10 M12 M8

HIT-IC / HIT-IG
M10 M12

HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC HIT-SC 12x 16x 16x 18x 22x 16x 18xc) 22x 22x 1,25 (8,1) 1,5 1,5 2,0 2,0 (10,9) -

1,5

2,0

Nrec [kN]

1,25 (8,5)

2,0 (15,0)

2,0

2,5

2,5 (23,7)

2,5 (13,9)

2,5

2,5 (19,3)

50 1,25 (7,0) 2,5 (12,0) 2,5 2,5 3,0 (24,3) 2,5 (21,3) 2,5 3,0 (28,1)

(Shell thickness 27,5 mm) Japan Aereted concrete block fb b) t 6 N/mm L x H x B [mm] 1900 x 600 x 100 Special application: through fastening HIT-SC HIT-SC x50 x85

Vrec [kN]

Nrec [kN]

1,25 (8,1)

1,75 (8,6)

1,75

2,0

2,0 (9,9)

130

Vrec [kN]
100

0,75 (6,3)

1,00 (9,2)

1,00

1,00

1,25 (12,8)

Japan a) b) c) Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb = brick strength HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
06 / 2011

662

Hilti HIT-HY 70

Recommended loads a) Frec for brick breakout and pull out in [kN] Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC Values in brackets: mean ultimate loads Fu,m [kN]: HIT-AC, HIT-V, HAS, HAS-E
Anchor size Base material Aereted concrete block fb b) t 6 N/mm LxHxB [mm] 1900 x 600 x 100 Japan a) b) Setting depth [mm] Nrec [kN] 50 Vrec [kN] Nrec [kN] 80 Vrec [kN] 0,75 (4,2) 1,0 (4,7) 1,0 (4,6) 1,0 (5,8) 1,5 (7,3) 1,0 1,75 1,75 (7,4) 1,0 (8,6) 1,75 (8,0) M6 M8 M10 M12 M8 M10 M12

HIT-G / HIT-IC

0,75

0,75 (4,0)

Recommended load values with consideration of a global safety factor Jglobal = 3,0: Frec = FRk / Jglobal fb brick strength

06 / 2011

663

Hilti HIT-HY 70

Design
Influence of joints: If the joints of the masonry are not visible the recommended load Nrec has to be reduced with the factor Dj = 0.75. If the joints of the masonry are visible (e.g. unplastered wall) following has to be taken into account: x The recommended load Nrec may be used only, if the wall is designed such that the joints are to be filled with mortar. x If the wall is designed such that the joints are not to be filled with mortar then the recommended load Nrec may be used only, if the minimum edge distance cmin to the vertical joints is observed. If this minimum edge distance cmin can not be observed then the recommended load Nrec has to be reduced with the factor Dj = 0.75. The decisive resistance to tension loads is the lower value of Nrec (brick breakout, pull out) and Nmax,pb (pull out of one brick). Pull out of one brick: The allowable load of an anchor or a group of anchors in case of pull out of one brick, Nmax,pb [kN], is given in the following tables: Clay bricks: Nmax,pb
[kN]

All other brick types: brick breadth bbrick [mm] 80 120 1,6 2,1 3,4 200 2,7 3,4 5,7 240 3,3 4,1 6,9 300 4,1 5,1 8,6 360 4,9 6,2 10,3 1,1 1,4 2,3 Nmax,pb
[kN]

brick breadth bbrick [mm] 80 120 1,2 1,5 2,6 200 2,1 2,6 4,3 240 2,5 3,1 5,1 300 3,1 3,9 6,4 360 3,7 4,6 7,7 0,8 1,0 1,7

brick length lbrick [mm]

240 300 500

brick length lbrick [mm]

240 300 500

Nmax,pb = resistance for pull out of one brick lbrick = length of the brick bbrick = breadth of the brick

lbrick

bbrick

Nmax,pb

For all applications outside of the above mentioned base materials and / or setting conditions site tests have to be made for the determination of load values. Due to the wide variety of natural stones site tests have to be made for determine of load values.

664

06 / 2011

Hilti HIT-HY 70

Materials
Material quality HAS
Part Threaded rod HAS-(E) Threaded rod HAS-(E)R Washer ISO 7089 Material Strength class 5.8, A5 > 8% ductile steel galvanized 5 m Stainless steel grade A4, A5 > 8% ductile strength class 70, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 Steel galvanized, Stainless steel, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 Strength class 8, steel galvanized 5 m Strength class 70, stainless steel grade A4, 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 Strength class 70, high corrosion resistant steel, 1.4529; 1.4565

Nut EN ISO 4032

Material quality HIT-A


Part HIT-AC rod HIT-ACR rod HIT-AN rod Material Carbon steel grade 5.8; galvanized to min. 5 m Stainless steel, grade A4-70; 1.4401; 1.4404; 1.4571 Carbon steel grade 3.6; galvanized to min. 5 m

Material quality sleeves


Part HIT-IG sleeve HIT-IC sleeve HIT-SC sleeve Material Carbon steel 1.0718; galvanized to min. 5 m Carbon steel; galvanized to min. 5 m PA/PP

Setting
Installation equipment
Anchor size Rotary hammer Other tools M6 M10 M12 TE2 TE16 blow out pump, set of cleaning brushes, dispenser M8

06 / 2011

665

Hilti HIT-HY 70

Setting instruction in solid base materials

666

06 / 2011

Hilti HIT-HY 70

Setting details: hole depth h0 and effective anchorage depth in solid base materials

Setting details HIT-AC, HIT-V, HIT-V, HAS, HAS-E, HAS-R


Anchor size M8 Nominal diameter of drill bit Effective anchorage depth Hole depth Minimum base material thickness Diameter of clearance hole in the fixture Minimum spacinga) Minimum edge distance a) Torque moment Filling volume d0 hef h0 hmin df smin cmin Tinst [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [ml] 10 80 85 115 9 100 100 5 4 HIT-AC, HIT-V M10 M12 12 80 85 115 12 100 100 8 5 14 80 85 115 14 100 100 10 7 M8 10 80 85 110 9 100 100 5 4 HIT-V, HAS, HAS-E, HAS-R M10 M12 M16 12 90 95 120 12 100 100 8 6 14 110 115 140 14 100 100 10 10 18 125 130 170 18 100 100 10 15

a) In case of shear loads towards a free edge: cmin = 200 mm A distance from the edge of a broken brick of cmin = 200 mm is recommended, e.g. around window or door frames.

06 / 2011

667

Hilti HIT-HY 70

HIT-IG, HIT-IC

HIS-N/RN

Setting details HIT-IG, HIT-IC


Anchor size M8 Nominal diameter of drill bit Effective anchorage depth Hole depth Minimum base material thickness Diameter of clearance hole in the fixture Length of bolt engagement Minimum spacing a) Minimum edge a) distance Torque moment Filling volume d0 hef h0 hmin df hS smin cmin Tinst [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [ml] 14 80 85 115 9 HIT-IG M10 18 80 85 115 12 M12 18 80 85 115 14 M8 14 80 85 115 9 HIT-IC M10 16 80 85 115 12 M12 18 80 85 115 14 HIS-N/RN M8 M10 M12 14 90 95 120 9 18 110 115 150 12 22 125 130 170 14

min. 10 max. 75 100 100 5 6 100 100 8 6 100 100 10 6

min. 10 max. 75 100 100 5 6 100 100 8 6 100 100 10 6

min. 8 min. 10 min 12 max.20 max.25 max.30 100 100 100 100 5 6 100 8 10 100 10 16

a) In case of shear loads towards a free edge: cmin = 20 cm A distance from the edge of a broken brick of cmin = 20 cm is recommended, e.g. around window or door frames.

668

06 / 2011

Hilti HIT-HY 70

Setting instruction in hollow base material using 330 ml foil pack

06 / 2011

669

Hilti HIT-HY 70

Setting details: hole depth h0 and effective anchorage depth in hollow base materials
HAS / HIT-AC with HIT-SC

HIT-AC, HIT-V, HAS

Setting details HIT-V / HAS / HIT-A with sieve sleeve


Anchor size Sieve sleeve HIT SC Nominal diameter of drill bit Effective anchorage depth Hole depth Minimum base material thickness Diameter of clearance hole in the fixture Minimum spacing a) Minimum edge distance a) Torque moment Filling volume M6 M8 M10 M12 12x50 12x85 16x50 16x85 16x50 16x85 18x50 18x85 22x50 22x85 d0 hef h0 hmin df smin cmin Tinst [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [ml] 12 50 60 80 7 100 100 3 12 12 80 95 115 7 100 100 3 24 16 50 60 80 9 100 100 3 18 16 80 95 115 9 100 100 3 30 16 50 60 80 12 100 100 4 18 16 80 95 115 12 100 100 4 30 18 50 60 80 14 100 100 6 18 18 80 95 115 14 100 100 6 36 22 50 60 80 14 100 100 6 30 22 80 95 115 14 100 100 6 55

670

06 / 2011

Hilti HIT-HY 70

Setting details: hole depth h0 and effective anchorage depth in hollow base materials
HIT-IG / HIT-IC with HIT-SC

HIT-IG / HIT-IC

Setting details HIT-IG / HIT-IC with sieve sleeve


Anchor size Sieve sleeve HIT SC Nominal diameter of drill bit Effective anchorage depth Hole depth M8 16x85 d0 hef h0 [mm] [mm] [mm] 16 80 95 HIT-IG M10 22x85 22 80 95 M12 22x85 22 80 95 M8 16x85 16 80 95 HIT-IC M10 18x85 18 80 95 M12 22x85 22 80 95

Minimum base 115 115 115 115 115 115 [mm] hmin material thickness Diameter of clearance df [mm] 9 12 14 9 12 14 hole in the fixture Length of bolt hS [mm] min. 10 max. 75 min. 10 max. 75 engagement Minimum spacing a) smin [mm] 100 100 100 100 100 100 Minimum edge cmin [mm] 100 100 100 100 100 100 distance a) Torque moment Tinst [Nm] 3 4 6 3 4 6 Filling volume [ml] 30 45 45 30 36 45 a) In case of shear loads towards a free edge: cmin = 20 cm A distance from the edge of a broken brick of cmin = 20 cm is recommended, e.g. around window or door frames.

06 / 2011

671

Potrebbero piacerti anche