Sei sulla pagina 1di 15

c

ontents

02 Overview 03 Product Category


03 G-SVC: High Voltage Static Var Compensator 08 G-SVG: High Voltage Static Var Generator 09 G-TSC: Thyristor Switched Compensator 11 G-DE-ICER: Mobile DC DE-ICER 13 G-DE-ICER: DC DE-ICER with SVC function 15 G-APF: Active Power Filter 17 G-RSF: Relay Switched Filter 22 DC Power Supply Device 23 EPS (Emergency Power Supply)

Introduction

Product Category

Overview

Product Category
G-SVC: High Voltage Static Var Compensator
Functions
Stabilize bus voltage, filter harmonic, balance three-phase load current, and improve power factor and system stability

SVC Principle

SVC Cabinet

SVC Valve

Thyristor Advantages
Thyristor valve is compact and occupies small space. Flexible cooling methods Manufacture, marketing, design and installation of 3~10KV HV Inverter, 460V/690V LV Inverter, UPS, DC UPS. Cooperation with Toshiba and Mitsubishi to found joint ventures to manufacture state-of-the-art products. We have full-featured test laboratory, world class product R&D approaches, and the most advanced test equipment in the industry. Power electronic technology oriented, specialize in R&D of power quality optimization and flexible power transmission equipment. Main products include: High Voltage Static Var Compensator (SVC), High Voltage Static Var Generator (SVG), Thyristor Switched Compensator (TSC), mobile DC DE-ICER or DE-ICER with SVC function, Active Power Filter (APF), Relay Switched Filter (RSF) with proprietary intellectual property rights for all the products and patents for scores of inventions and new utility models. Introduce and establish many management approaches and systems to guarantee high-quality products, such as ISO9001, ISO14001, OHSAS18001, 6S, ERP, CRM, PLM, JIT, MBO and CEMS. According to optimum condition it adopts wind cooling, heat pipe cooling or water cooling system. For loads with low reactive power, such as wind power, coal mine, electric railway etc., Guirong Xieping creatively develops natural wind cooling construction with free maintenance, which greatly reduces investment and routine maintenance. Unique precise crimp structure to ensure optimum running status of thyristor components so as to extend the service life of these components.

Advanced instantaneous reactive power control algorithm to ensure the response time of SVC system is less than 10ms. Control methods: it works under the reactive control or voltage control mode. Control protection system adopts hardware and software platform at American military grade, which ensures system high reliability. Protection for BOD operation, valve components failure, triggering and detection channel failure, backup triggering frequent operation etc. to ensure safe system operation. Optical fiber to carry on signal transmission which ensures the signal reliable without disturbing.

02

Power Electronics

03

Product Category
Applications
Substation In the regional power grid, multi-stage thyristor switched capacitor banks are generally used to compensate system reactive power and improve power factor. This method has the following disadvantages: 1. It can only provide capacitive reactive power, and it cannot make accurate regulation along with the changes of loads. 2. It can easily over-compensate the system in light load, increase the bus voltage, and damage the stability of the electric equipment and system. SVC system can accurately make capacitive and inductive reactive power compensation, which helps to solve the overcompensation problems thoroughly and conveniently while stabilizing bus voltage and improving power factor.
Arc furnace

Product Category

reactive current for the electric arc furnace, stabilize the bus and grid voltage and reduce the flicker influence. The split phase compensation function of SVC can eliminate three-phase unbalance, and filter can eliminate harmful higher harmonics and provide the system with capacitive reactive power to improve power factor.

Above issues can be perfectly solved after applying SVC system, which maintains the bus voltage stability and eliminate harmonic interference.

Wind Power Industry Since the wind power cannot be constant, the power generated by the wind farm is constantly changing, and SVC fast response to power changes can perfectly compensate the power generated by the wind farm.

Example 1

The valid value curve of 6kV system voltage before SVC activation is shown in the figure. There are obvious voltage drops during the rolling mill operation. The maximum voltage
Other load
Compensation device

drop is 7.3%.

Hoister Hoisting machine and heavy-industry loads will influence the power grid in the following aspects; 1. They cause voltage fluctuation of the power grid 2. They reduce power factor 3. They generate harmful higher harmonics. Arc Furnace When the electric arc furnace is connected with the power grid as the nonlinear and irregular loads, it will cause harmful influences to the power grid, which mainly include: 1. They cause severe three-phase unbalance of the power grid, and generate negative sequence current 2. They generate higher harmonics, usually 2nd, 4th even harmonics and 3rd, 5th, 7th odd harmonics often co-exist 3. They cause voltage fluctuation and voltage flicker 4. They reduce power factor SVC has fast response speed, which can quickly provide
P=Arc furnace power active power SVC=SVC connection U=Arc furnace busbar voltage ORI=without compensation

The valid value curve of 6kV system voltage after SVC activation is shown in the figure. The voltage drops are reduced during rolling mill operation, and the maximum voltage drop is 1.9%, which meets the national standard.

Above issues can be perfectly solved after applying SVC.

Rolling Mill The reactive impulse caused by rolling mill and other industrial symmetrical loads during operation will cause the following influences: 1. They cause voltage fluctuation of the power grid. 2. They reduce power factor 3. They generate harmful higher harmonics, which are represented by 5th, 7th, 11th, 13th odd harmonics, causing severe voltage distortion of the power grid.

04

Power Electronics

05

Product Category
Electric Locomotive Electric locomotive applies single phase power supply, which causes severe three-phase unbalance of the power grid, reduces the power factor and generates negative sequence current. SVC uses split phase quick compensation function to balance the three-phase power grid and increase the power factor.

Product Category

Typical Projects
1.SVC project at Mali Wind Farm of China Huaneng Group Co., Ltd. Zhenlai County, Jilin Province In September of 2008, Zhejiang Guirong Xieping Technology Co., Ltd. won the bid of supplying a set of TCR+FC model SVC to Mali Wind Farm owned by China Huaneng Group Co., Ltd. Zhenlai County, Jilin Province. It was installed at 220kV stepup substation of the wind farm with power supply voltage of 35kV.Based on the voltage change features of wind power system, G-SVC adopts advanced reliable control platform and control algorithm to adjust the reactive power value instantly, continuously and smoothly, suppress the voltage fluctuation and flicker effectively, filter harmonic, and improve the system stability as well. It has been in good operation condition since it was put into service. 2.SVC project at Beiman Special Steel Co., Ltd. of Northeast Special Steel Group In July of 2008, Zhejiang Guirong Xieping Technology Co., Ltd. made reconstructive repair for the SVC installed at a matched 220kV substation for a 90 tons ultra high power electric arc furnace at Beiman Special Steel Co., Ltd of Dongbei Special Steel Group. It used to be the biggest single TCR model SVC with power supply voltage of 35kV and compensating capacity of 127M. In April of 2008, there was a serious accident that the main components such as capacitors and reactors etc. mostly burned down. After checking and analyzing this malfunction, our engineers found out the fault cause and presented the reconstructive repair proposal according to the manufacturing technique of electric arc furnace and actual situation of power supply system. After more than two months of repair and rectification, the SVC operated successfully in July of 2008. It operated steadily and all parameter indicators such as voltage fluctuation, voltage flicker, harmonic and three-phase unbalance of the power grid achieved the national standard. The successful operation of the SVC not only ensures normal production activities but also brings good economic benefits for users.
SVC Cabinet FC Branch Circuit TCR

06

Power Electronics

07

Product Category

Product Category

G-SVG: High Voltage Static Var Generator

G-TSC: Thyristor Switched Compensator


Functions
Improve power factor, stabilize bus voltage and suppress harmonic current.

Technical Advantage
Reduce impact onto the system during capacity activation and extend the service life of equipment by zero-crossing point activation by using thyristor as switch Achieve fast calculation and logical judgment by selfG-SVG principle diagram G-SVG cabinet

developed controller based on 32-bit DSP and the system response time is no more than 20ms System has different kinds of control objectives and calculations such as open-loop control, closed-loop control, power factor control and voltage control. Customers requirements can be met by choosing different control objectives and control calculations according to different load characteristics on site. Ensure safe operation of the device through protective measures such as over-voltage, low-voltage, over-current and distortion protection. Suppress harmonic current by using series reactor to ensure safe and stable operation of the device. Control units have remote communication function which enables the cascade connection with other TSC and APF instantly.

Functions
Stabilize bus voltage, filter harmonic, balance three-phase load current, and improve power factor and system stability

Technical Advantages
Rated inductive and capacitive reactive power can be adjustable smoothly and continuously Response speed is faster than 5ms Forced air cooling mode Integral structure adopts floor type or wall-mounting type Indoor installation Controlled by special software to avoid overload Parallel operation mode of several SVG devices IMTBF is more than 100 thousand hours The main CPU of SVG controller is the most advanced digital DSP The main protective functions of SVG are: AC over-current protection, DC over-voltage protection, IGBT over-current protection and IGBT over-temperature protection.

Applications
Urban rail transit, steel and metallurgy industry, sewage disposal industry automobile industry, tobacco industry, papermaking industry, shipbuilding industry and other industries

Applications
Automobile industry, coal mine, chemistry, papermaking, shipbuilding, wind power, regional substation, traffic industry, steel metallurgy, and other industries

08

Power Electronics

09

Product Category

Product Category

G-DE-ICER: Mobile DC DE-ICER


Typical Projects
1. TSC Project of Shaoshing Fuling Holding Group Fuling Industrial Group Co., Ltd. is one of the earliest enterprises manufacturing BOPP film in China with the title of Small-Sized Giant enterprise in Shaoshing. Its main electric equipment is frequency conversion and speed regulation electromotor whose power factor was 0.71 before compensation. After analyzing the equipment operation and actual power supply system condition, our engineers determined to install 400 kVar G-TSC at No.1 transformer, 480 kVar G-TSC at No.3 transformer and 480 kVar G-TSC at No.4 transformer separately. They were put into service successfully in October of 2008 and operated steadily, and then the power factor went up to 0.98 or higher. Both voltage fluctuation and flicker met the national standards and the stability of power supply system is improved by suppressing the impact of harmonic current onto corresponding equipment. 2. TSC Project of Taizhou Maple Leaf Shipyard Co., Ltd. Taizhou Maple Leaf Shipyard Co., Ltd. located in Taizhou, Zhejiang Province, has the floor area of 270 thousand square meters and the coast line of 13 kilometers. Its one of the largest shipbuilding factories in Zhejiang Province. Voltage flicker and low-voltage caused by operation of welding machines in their welding workshop had a strong impact on the welding technology of shipbuilding. After analyzing the operation of their main load, welding machines, our engineers determined to install partial compensation capacity of 270 kVar and total compensation capacity of 300 kVar G-TSC at their No.2 line. It was successfully put into service in July of 2008. It operated steadily and the power factor went up to 0.98 or higher. The power supply voltage became stable and voltage fluctuation was improved obviously. It highly improved the quality of their production welding technology.
TSC

Functions
Quick deicing for power transmission lines

Technical Advantage
With special technology and modular design, DE-ICER device is installed in a standard container. Therefore its easy to install without any foundation construction. Its suitable for regional emergency de-icing and counter-disaster use. Controlled rectifying de-icing power supply, current can be set zero-start, which reduces impact on the system. Equipped with auto phase-conversion function during the DE-ICE operation . Users can set the de-icing sequence for lines by themselves. All works will be done automatically by the system itself. Its fully digital control system adopts software and hardware platform at American military grade, which ensures system high reliability. Considering the economy and usability of the DE-ICER, users can extend it with SVC function. Considering the de-icing operation states, users can extend it with FC filter banks to filter harmonic produced while de-icing. De-icing current with adjustable range from 0 to 2000A

Applications
110kV or above substations of power systems, which are subject to snow disasters. Substations with voltage of 110kV or above, and easily be affected by the ice and snow storm

10

Power Electronics

11

Product Category
500kV busbar

Product Category

G-DE-ICER: DC DE-ICER with SVC Function


Functions
35kV busbar

220kV busbar

be realized by application software and it is not necessary to be changed for the system management platform. Auto phase-conversion function during operation under DE-ICE mode, and users can set the de-icing sequence for lines according to their own requirements. All works are completed automatically by the system itself. Equipped with FC filter banks, which can filter amounts of harmonic when it runs in DE-ICE mode, ensuring the safe running of power grid equipments. Moreover, it compensates reactive power from the system to make sure other electric devices in the power grid work properly. Patent technology of Controlled Rectifying SVC, and rectifying circuit instead of regular AC circuit, and DC reactor instead of regular AC reactor, which makes the operation more reliable and the design more appropriate. Highest output DC voltage is 47kV. De-icing current is adjustable and can be set at any value from 0A to 5000A. It can be set zero-start and reduce impulsion to the system.

Quick DE-ICE function for transmission lines and SVC function with convenient switchover between the two functional modes.

Technical Advantage
SCR

Combines technical characteristics of DC DE-ICER (G-DE-ICER) and high voltage Static Var Compensator (G-SVC)
Station Station

DC reactor

Unique circuit design conception (patent product) Static Var Compensator (G-SVC) function combined with DC DE-ICER, which effectively improves the equipment utilization and usability Switchover between DE-ICE mode and SVC mode can be

Disconnector

5th

7th 11th Filter

13th

Disconnector

Disconnector 50Hz filter Disconnector

Short-circuit disconnector

realized by switch on the DC shunting-switch of the rectifier bridge without changing the operation mode of the rectifier bridge (See Figure2 DE-ICE mode.). Therefore the switchover of operation modes is quite convenient and safe. Its fully digital control system adopts hardware platform at American military grade, which ensures system reliability. Switching between DC DE-ICE mode and SVC mode can

Principle of DE-ICER

Typical Projects
1. DC DE-ICER project of Shaoguan Power Supply Bureau of China Southern Power Grid On Dec.10th, 2008 the DC DE-ICER which is developed by Zhejiang Guirong Xieping Technology operated successfully at Tangkou power substation of Shaoguan Power Supply Bureau in the 110kV transmission lines of China Southern Power Grid. This DE-ICER was the first DC DE-ICER applied in Guangdong Power Grid, which adopted mobile design, and was installed in a 40-feet standard container. It combined several patents of Guirong Xieping and carried out full-automatic smart de-icing operation quickly, safely and stably. The successful operation of the DE-ICER greatly improved the de-icing and counter-disaster capability of Guangdong Power Grid. 2. The DC DE-ICER project of Qing Yuan Power Supply Bureau of China Southern Power Grid The other DC DE-ICER which is also developed by Guilin Xieping was installed at 220kV Anfeng substation of Qingyuan Power Supply Bureau, and it was successfully put into service on Jan.6th, 2009.

DE-ICER and compensation device of Shuanglong 500kV substation

Expert guidance at site

Internal structure of DE-ICER

12

Power Electronics

13

Product Category

Product Category

G-APF: Active Power Filter


Functions
500kV busbar 220kV busbar 500kV busbar 220kV busbar

Filter harmonic, reduce loss and improve power quality

Technical Advantage
35kV busbar 35kV busbar

Actively filter harmonic. Filter 2nd-50th harmonic simultaneously without being affected by the change of system impedance so that the index of power quality meets the requirements of national standards, and the system resonance is eliminated automatically.

DC reactor SCR DC reactor

SCR Disconnector

Unique electrical topological structure with low output current high-frequency ripple to reduce the loss and the full-load power consumption being less than 1.3%. DSP full-digital control. 5 kHz switching frequency and instantly response to dynamic load change in 200us and completely keeps
5th 7th 11th 13th Filter Disconnector

pace with load change in 10ms. Automatic limit current function is active when load exceeds the rated capacity range to ensure safe operation of system while guarantee filtering effect.

DC reactor 5th Disconnector 7th Filter 11th 13th

Disconnector

Disconnector

Short-circuit disconnector

Perfect control protection circuit with operational protect system of over-voltage, over-current and over-heat to ensure safe operation of system Modularization design is convenient to extend up to 10 units operating parallel at the same time without influence with each

Run on SVC mode

Run on DE-ICE mode

Applications
110kV or above power systems key substations, which are subject to snow disasters

other for every unit has independent controller.

Applications
Urban rail traffic industry, petrochemical and natural gas, steel and metallurgy industry,sewage disposal, cement, automobile, tobacco, paper making, shipbuilding, hospital, mobile communication base station, and other industries

Typical Projects
1.The DC DE-ICER project of Jinhua Shuanglong 500kV Substation Zhejiang Guirong Xieping Technology Co., Ltd. associates with Zhejiang University to develop the DC DE-ICER with SVC function for the 500kV load-center substation of Zhejiang Electric Power Co., Ltd. Its the largest technology project in the history of Zhejiang electric power. The device adopts patented thyristor rectifying SVC technology of Guirong Xieping, with the de-icing current of 5000A and the SVC compensation capacity of nearly 100Mvar. This project passed the preliminary design review on April 21st, 2009, and director of design review committee, academician Han Yingduo gave high comments of Innovative and worthwhile to promote to the project. On January 1st, 2010, the DC DE-ICER with SVC function at Zhejiang Shuanglong 500kV substation operated successfully after more than one month of test running. Moreover, it passed the tests of State Power Grid Corporation on January 22nd, 2010. The success operation of the device greatly strengthens and improves the ability of de-icing and counter-disaster as well as the stability of power grid in Zhejiang.

14

Power Electronics

15

Product Category

Product Category

G-RSF: Relay Switched Filter


Typical Projects
1. APF Project at Shaoshing Fuling Holding Group Fuling Industrial Group is one of the earliest enterprises manufacturing BOPP film in China with the title of Small-Sized Giant enterprise in Shaoshing. Its main electric equipment is frequency conversion and speed regulation electromotor whose requirement of electricity power quality is very critical. After analyzing the situation of machine operation and power supply system, our engineers determined to install 150A G-APF respectively at No.1 transformer and No.4 transformer. They were put into service successfully in October of 2008 and operated steadily and filtered more than 90% of harmonic, therefore the stability of power supply system is greatly improved by suppressing the influence of harmonic current to system operation.

Functions
Filter harmonic current, compensate reactive power, stabilize bus voltage and improve the stability of power usage

1. RSF Project at Yunhe Hutai Valve Co., Ltd. Yunhe Hutai Valve Co., Ltd., one of the enterprises applying intermediate frequency furnace is located at Shitang Town, Yunhe County, Lishui City, Zhejiang Province. Its intermediate frequency furnace is a typical 6-pulse rectifier. After testing harmonic of the load, our engineer concluded that 5th and 7th harmonic current exceeded the national standard and need to be improved. The engineers determined to install 5th and 7th filter branches after simulation calculations. The device was put into service successfully in November of 2008 and operated steadily and all harmonic current values met with the national standard. The power factor increased to higher than 0.95, therefore the stability and safety of the equipment are improved and the impact of harmonic current to system equipment was reduced.

Technical Advantage
Compared with traditional RSF, G-RSF has intelligent tune function which solves the over-current of harmonic problem effectively. Its added with harmonic protection function to cut off the filtering branch when system resonance occurs to prevent damage to itself and the customers equipments.

Grid

The capacitors and reactors of the filter branch are wellchosen according to the influence of the harmonic current. The capacitance value and inductance value can be ensured stable after long time running of the capacitors and reactors under the on-site environment condition. G-RSF has many kinds of protection function such as over

Harmonic and reactive current component

Harmonic current Compensation current Harmonic Non-linear load and reactive current detection circuit Command signal Compensation current generating circuit

voltage protection, serious over voltage protection, over current protection, harmonic distortion protection, filter branch over current protection and filter branch serious over current protection. The system can be ensured safe operation under different kinds of abnormal conditions. Reserved communication ports allow data transmission with remote main station by constructing secondary system. Electric power sector can carry out post-monitor by real-time monitoring on working status, switching situation of filter branch and harmonic filter effect of on-site filter equipment. The quality of key components of the device such as controllers and reactors and so on is guaranteed for they are developed and produced by Zhejiang Xieping independently.
RSF

Working principle of APF

Typical Projects
Steel and metallurgy, petrochemical, cement, construction building materials, textile, water supply and drainage industry, and other industries
APF

16

Power Electronics

17

Product Category
1.3 Detailed specifications and technical requirements of the required equipment. 1.4 Special requirements of environmental and electrical conditions of the supplied equipment. (If there are no special requirements, it should comply with the general standards of the corresponding HV electrical equipment) 2. EPC Contracting Based on users' specific requirements, we are fully responsible for the system design, electrical design, construction design, civil design of the required equipment engineering and equipment supply, installation and construction, system integration commissioning, and operator training to meet the users requirements and technical specifications and ensure successful take-over and operation of the equipment. Users should provide the following basic information and data
Principle of RSF

Product Category

2.2.5.1 Voltage fluctuation and flicker level of the assessment point (i.e. PCC point, the same as follows). 2.2.5.2 Harmonic level of the assessment point. 2.2.5.3 Negative sequence voltage or three-phase asymmetric level of the assessment point. 2.2.5.4 Billing power factor level of the assessment point. 2.2.5.5 Other indicators of the assessment point. 2.2.6 Detailed single line drawing of the power supply system as well as main parameters of relevant equipment of user (transformers, reactors, lines etc.) 2.2.7 Short-term and long-term load changes of the users power supply system (short-circuit capacity, mode of feeder operation etc.) 2.2.8 Special requirements of environmental and electrical conditions of the supplied equipment. 2.2.9 Special requirements for civil engineering, installation, construction and the required equipment.

for this ordering mode 2.1 Applications, purpose and basic requirements of the

Ordering Instruction
1. Complete Set of Equipment Supply The system design, electrical design, construction design, civil design, installation and construction for the required equipment engineering should be provided by the uses. We provide all the main and auxiliary equipment according to the equipment specifications, parameters and requirements of uses, and participate in the system integration commissioning. Users should provide the following basic information and data for this type of equipment supply: 1.1 Applications of the required equipment, the detailed single line drawing of its power supply system as well as main parameters of relevant equipment (transformers, reactors, lines etc.) 1.2 Detailed single line and tie line drawing of the system design for the required system as well as regulation characteristics and requirements.

required equipment. 2.2 Detailed equipment parameters of the users main equipment, including: 2.2.1 Type, model, operating features of the working main equipment (provide typical working conditions and relevant requirements on the production process if necessary) 2.2.2 Rated parameters of the working main equipment (rated voltage, current, power, impedance, etc. ) 2.2.3 Operational features, active and reactive power fluctuation features during operation (fluctuation amplitude, time feature, etc.) 2.2.4 Harmonic generating capacity of the working main equipment (spectrum features of harmonics at each order) 2.2.5 Technical specification and relevant standard requirements that users expect the required equipment to reach after they are in service, including:

18

Power Electronics

19

Product Category
Achievements
No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34

Product Category

Customer
Zhejiang Electric Power Co., Ltd.(Zhejiang Shuanglong 500kV Substation DE-ICER) Jilin Huaneng Renewable Energy Co., Ltd.(Zhenlai Mali Wind Farm Phase I Project) Huaneng Jilin Power Generation Co., Ltd.(Zhenlai Mali Wind Farm Phase II Project) Inner Mongolia Mengdian Huaneng Thermal Power Co., Ltd. (Jarud Wulijimuren Wind Farm Phase I Project) East China Special Steel Co., Ltd. Baosteel Group Ningbo Steel Co., Ltd. Jutai Special Steel Co., Ltd. Northeast Special Steel Group, Beiman Special Steel Zhenshi Group Eastern Special Steel Co., Ltd. Samsung Precision Stainless Steel (Pinghu) Co., Ltd. Guilin Power Capacitor Co., Ltd.(Jinzishan Wind Farm Reactive Compensator) Guangdong Power Grid Company, Qingyuan Power Supply Bureau Guangdong Power Grid Company, Shaoguan Power Supply Bureau Guangdong Power Grid Company, Shaoguan Power Supply Bureau China Ruili Group Lishui Yunzhongma Textile Co., Ltd. Hangzhou Xinshi Electric Switch Co., Ltd. G-TSC Low Voltage Var Compensator Guangdong Yangjianggang Harbor affairs Co., Ltd. Zhejiang Wuhuan Titanium Co., Ltd. Zhejiang Wangfeng Special Steel Co., Ltd. Zhejiang Haining Switchgear Plant Shaoxing Tianpu Plastic Product Co., Ltd. Zhejiang Suijin Special Metal Casting Co., Ltd. Yuhuan Huancheng Auto Accessories No.2 Plant Hangzhou Aopute Electrical Equipment Co., Ltd. Hangzhou Aopute Electrical Equipment Co., Ltd. Taizhou Maple Leaf Shipbuilding Co., Ltd. Yunhe Xinshan Special Steel Casting Co., Ltd. Yunhe Yinfa Precision Casting Factory Yunhe Baodelong Valve Manufacturing Co., Ltd. Yunhe Hutai Valve Co., Ltd. Hangzhou Zhongbin Mechanical Foundry Ruian Zhenwu Stainless Steel Factory

Location
Zhejiang Jinhua Jilin Zhenlai Jilin Zhenlai Inner Mongolia Tongliao Zhejiang Lishui Zhejiang Ningbo Zhejiang Lishui Qiqihar Zhejiang Jiaxing Zhejiang Jiaxing Guangxi Guilin

Equipment
G-DE-ICER DC DE-ICER WITH SVC FUNCTION G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator

No.
35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57

Customer
Zhejiang Dongtai Valve Co., Ltd. Guangxi Jinzishan 99MW Wind Farm Project Longyuan (Siziwang) Wind Power Generation Co., Ltd. Erdos Electric Power Survey and Design Institute Inner Mongolia Boyuan Electric High Voltage Equipment Co., Ltd. Hohhot Binjiang Electrical Equipment Co., Ltd. Inner Mongolia Boyuan Electric High Voltage Equipment Co., Ltd. Hohhot Shimin Electrical Equipment Co., Ltd. Inner Mongolia Dongwu Railway Co., Ltd. Zhengzhou Yuwang Electric Supply Co., Ltd. Yunnan Dianbei Power Supply Bureau (Zhe Hai Bian) Yongcheng Coal Power (Group) Co., Ltd. Jinan Steel Group, Shiheng Special Steel Factory Wuhan Steel (1700 Hot Rolling Project) Baotou Steel Company China Electric Power Research Institute China Electric Power Research Institute (Yunnan Chuxiong Desheng Steel Factory) Baosteel Group No.1 Steel Co., Ltd. China Electric Power Research Institute (Ningbo Huaguang Stainless Steel Co., Ltd.) Lishui Electric Utility Supply Company China Research Institute (Xichang New Steel Enterprise Co., Ltd.) China Research Institute (Luoyang Zhongzhong Founding Co., Ltd.) China Research Institute (Fujian Dongyu Stainless Steel Co., Ltd.) China Electric Power Research Institute (Panzhihua Steel Group Chengdu Steel Co., Ltd.) Shanghai Baosteel Anda Energy Quality Co,. Ltd. Anshan Rongxin Power Electronics Co,. Ltd. Chongqing Kelian Electric Co., Ltd. Construction and Operation Department of SGCC China EPRI Science & Technology Co., Ltd.

Location
Zhejiang Lishui Guangxi Guilin Inner Mongolia Baotou Inner Mongolia Erdos Inner Mongolia Hohhot Inner Mongolia Hohhot Inner Mongolia Hohhot Inner Mongolia Hohhot Inner Mongolia Hohhot Henan Zhengzhou Yunnan Dianbei Henan Yongcheng Shandong Taian Hubei Wuhan Inner Mongolia Baotou Beijing Yunnan Chuxiong Shanghai Zhejiang Ningbo Zhejiang Lishui Sichuan Xichang Henan Luoyang

Equipment
G-RSF Reactive Power Filter G-SVC Static Var Compensator (2 sets) G-SVC Static Var Compensator G-SVC Static Var Compensator (2 sets) G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator (2 sets) G-SVC Static Var Compensator G-SVC Static Var Compensator G-SVC Static Var Compensator (2 sets) Filter capacitor (2 sets) Filter capacitor Filter capacitor (4 sets) Filter capacitor (3 sets) Filter capacitor Filter capacitor (20 sets) Filter capacitor Filter capacitor (12 sets) Filter capacitor (3 sets) Filter capacitor (2 sets) Filter capacitor (4 sets) Filter capacitor (4 sets)

Zhengzhou Railway Bureau, Zhengzhou Power Supply Section Henan Zhengzhou

Guangzhou Qingyuan G-DE-ICER DC DE-ICER Guangzhou Shaoguan G-DE-ICER DC DE-ICER Guangzhou Shaoguan G-FC DC DE-ICER with filter Zhejiang Ruian Zhejiang Lishui Zhejiang Hangzhou Zhejiang Lishui Zhejiang Cixi Zhejiang Lishui Zhejiang Haining Zhejiang Shaoxing Zhejiang Lishui Zhejiang Yuhuan Zhejiang Hangzhou Zhejiang Hangzhou Zhejiang Taizhou Zhejiang Lishui Zhejiang Lishui Zhejiang Lishui Zhejiang Lishui ZhejiangXiaoshan Zhejiang Wenzhou G-APF Active Power Filter G-RSF Reactive Power Filter G-TSC LV Var Compensator G-TSC LV Var Compensator G-TBB HV Automatically Switched Var G-RSF Reactive Power Filter G-APF LV Active Power Filter G-TSC LV Var Compensator G-APF LV Active Power Filter G-TSC LV Var Compensator G-RSF Reactive Power Filter G-RSF Reactive Power Filter G-APF Active Power Filter G-TSC LV Var Compensator G-TSC LV Var Compensator G-TSC LV Var Compensator G-TSC LV Var Compensator G-RSF Reactive Power Filter G-RSF Reactive Power Filter G-RSF Reactive Power Filter G-RSF Reactive Power Filter G-RSF Reactive Power Filter G-RSF Reactive Power Filter

Guangdong Yangjiang G-TBB HV Automatically Switched Var Compensator

58

Fujian Fuzhou

Filter capacitor (4 sets)

59 60 61 62 63 64 65

Sichuan Chengdu Shanghai Liaoning Anshan Chongqing Beijing Beijing

Filter capacitor (10 sets) Filter capacitor (2 sets) Filter capacitor (12 sets) Filter capacitor (4 sets) Filter capacitor (38 sets) Filter capacitor (10 sets) Filter capacitor (8 sets)

China Southern Power Grid Co., Ltd., Extra High Voltage Power Guangdong Transmission Company Guangzhou

20

Power Electronics

21

Product Category

Product Category

DC Power Supply Device

EPS (Emergency Power Supply)


3) AC input voltage is in sine waveform, and the voltage fluctuation range rated values20%; the frequency 50Hz10%; 4) No inflammable, explosive and dangerous materials, harmful gases that corrode and damage the insulation, and no conducting particles at operation sites; 5) The altitude 2000m;

List of detailed model specifications


Wide application range for inductive loads (generators, water pumps etc.) and various hybrid loads; The charger uses high-frequency switch mode power supply, modular design and N+1 redundancy;

Usage
GZDW series DC power supply cubicles adopts soft switching high-frequency power modules as the charging device. The products are used in power plants, substations and power supply rooms of enterprises in mining industry up to 800KV as DC operation power supply for circuit breaker opening and closing, relay protection device and automatic device as well as DC power supply for emergency lighting and control. Micro computer controller can effectively manage automatic recharging, and monitor the status of DC power supplies and batteries on line. It has Four-Remote features: remote signaling, remote metering, remote control and remote pulse, especially designed for unattended substations and digital substations.

3) AC input voltage is in sine waveform, and the voltage fluctuation range is rated values20%; the frequency 50Hz10%; 4) No inflammable, explosive and dangerous materials, harmful gases that corrode and damage the insulation, and no conducting particles at operation sites; 5) The altitude 2000m;

The inverter adopts the latest generation of IGBT power components to ensure high reliability;

Usage
1) The unit is used as emergency power supply for elevators, central air conditioners, fire pumps, rolling gates, exhaust fans, fire-fighting equipment, lighting, office equipment in municipal administration and public utilities, such as subways, exhibition centers, sports facilities, high-rise buildings, market places, hospital, security industries, banks, office buildings and government offices. 2) Applied as emergency lighting and emergency power supply in power plants, hydropower stations and substations

The optimized Sinusoidal Pulse Width Modulation (SPWM) technology is used; The combination of modern electronic technology and PC technology improves intellectualization; Built-in CPU and digital circuit control significantly reduces the numbers of the control circuit components, which improves the system reliability; Stable performance, safe and reliable, and long service life; All the operation parameters of the unit are displayed on the LCD The unit can provide RS232 or RS485 communication interface to communicate with PC, and provide several passive contacts; Complete protection function, high reliability, and MTBF 100000 hours; Reliable lightning protection and solid electrical insulation measures to ensure system and personal safety.

List of detailed model and specification


1. Input technology specifications AC input power supply: 3-phase 4-wire 380V20%/220V15% Frequency: 50HZ10% 2. Output technology specifications Rated output DC voltage: 220V, 110V, 48V; Rated output DC current: 2A1200A; Float charging voltage: 198V 280V/90V 160V (continuous and adjustable) Equal charge voltage: 220V 280V/110V 160V (continuous and adjustable) Stabilized voltage precision: 0.5%; (Typical value 0.2%) Stabilized current precision: 0.5%; (Typical value 0.2%) Ripple factor: 0.1%; (Typical value 0.05%) Efficiency: 95%;

Executive standard
GB/T 19826-2005 General Specification and Safety Requirements for DC Power Supply Equipment of Power System

Applied standards
GB/T 17945-2000 Fire Emergency Lighting

Normal working conditions


1) When applied indoors, the ambient temperature range is -10C~+45C. When it is out of service, the indoor temperature range is -25C~+55C; 2) Daily average relative humidity 95%, and monthly average relative humidity 90%;

Working conditions
1) When applied indoors, the ambient temperature range is -10C+45C. When it is out of service, the indoor temperature range is -25C+55C 2) Daily average relative humidity 95%, and monthly average relative humidity 90%;

22

Power Electronics

23

Product Category
Rated output power range Voltage AC input Frequency Voltage Frequency AC output Waveform Applicable load type Nominal voltage Battery Charging time Switching time Emergency power supply time Overload capacity Efficiency Protection Noise (1m distance)
2.2~22kW 30~100kW 3-phase 4-wire 380V25% 50Hz5% Normal: the same with the mains voltage; Emergency: 220V3% Normal: synchronous with the mains frequency; Emergency: 50Hz0.5% Sine wave (lower HD3%) Applicable for various single-phase or 3-phase lighting, power loads DC220V <24h General conditions: 5s Special conditions: 4ms >90min (based on the needs) 120% normal working; 150% 10s Emergenc>90% Emergency >93% Output over/under voltage, over current, short circuit protection, over charge of storage batteries, over discharge protection Normal: No noise; Emergency: <55dB DC460V