Sei sulla pagina 1di 11

FAN COIL M SERIES

FC 245/AE

Ceiling Concealed Ducted Ceiling Cassette Wall Mounted

MCW MCC MCK MWM

Concealed
The high external static pressure makes units ideal for both ducted and free air delivery applications. MCW are able to satisfy every requirement in terms of air conditioning in wide space requiring the ceiling installation. The quite contained height makes units ideal for false ceiling installation even in vin buildings with narrow ceiling spaces

Model
Air flow rate (1) Total cooling capacity (1) Sensible cooling capacity (1) Water flow rate Pressure drop Total heating capacity (2) Total heating capacity auxiliary coil (3)
Static pressure m /h (max.) m3/h (med.) m3/h (min.) kW (max.) kW (med.) kW (min.) kW (max.) kW (med.) kW (min.) L/h kPa W (max.) W (med.) W (min.) W (max.) W (med.) W (min.) Pa L/h kPa W A inches
3

200C

300C

400C

600C

800C

1000C

1200C

Water flow rate Pressure drop Power supply Power input Absorbed current Connection

408 306 204 2,3 1,9 1,6 1,5 1,3 1,0 420 16 3,9 3,4 2,8 2,6 2,1 1,6 60 420 16 51 0,22 3/4

595 459 340 3,4 2,8 2,4 2,3 2,0 1,5 600 13 5,7 4,8 4,1 3,4 2,9 2,3 60 600 13 69 0,29 3/4

765 1138 1427 663 901 1155 510 731 952 4,2 6,5 8,2 3,7 5,6 7,1 3,2 5,0 6,1 2,9 4,4 5,4 2,6 3,7 4,6 2,1 3,2 3,8 780 1080 1740 22 47 33 7,5 11,3 14,2 6,6 9,5 12,1 5,4 8,3 10,8 5,0 6,0 6,7 4,5 5,1 5,8 3,8 4,5 5,1 60 60 60 780 1080 1740 22 47 33 230V 1 ph 50 Hz 83 149 205 0,36 0,64 0,93 3/4 3/4 3/4

1699 1308 1054 9,2 8,1 7,2 6,2 5,3 4,6 1800 26 15,8 13,1 11,6 9,1 7,7 6,6 60 1800 26 219 1,04 3/4

2175 1750 1444 11,9 10,6 8,9 8,0 7,0 5,6 2280 45 20,5 17,4 15,1 10,2 8,9 7,8 60 2280 45 281 1,22 3/4

Note: Air flow and Performances referred to EUROVENT 6/3 conditions: 1. Cooling: Air temperature entering the unit: 27C d.b.; 19C w.b.; water inlet temperature: 7C; T 5K. 2. Heating: Air temperature entering the unit: 20C; water inlet temperature: 50C; water flow rate same as for cooling mode 3. Heating (auxiliary coil): Air temperature entering the unit: 20C; water inlet temperature: 70C; T 5K.

Model
dB (A) (max) dB (A) (med) dB (A) (min)

200C

300C

400C

600C

800C

1000C

1200C

36,0 35,0 34,0

37,0 35,0 34,0

37,0 35,0 34,0

39,0 36,0 35,0

39,0 37,0 35,0

39,0 38,0 35,0

40,0 36,0 35,0

The extremely compact and lightweight design facilitates the delivery and installation of units. Height is barely 251mm allowing the installation in all false ceiling types. Water connection sides can be changed easily in the field

Model
Height Length Width Weight

200C

300C

400C

600C

800C

1000C

1200C

mm mm mm Kg

251 714 490 19

251 884 490 22

251 1014 490 26

251 1214 490 30

251 1464 490 41

251 1564 490 44

251 1824 490 46

The new line of Ducted fan coils units, offers a wide range of solutions to air distribution problems applicable on both new and refurbished buildings, independently on the rooms volume. Multiple rooms can be cooled together with only one unit and the conditioned air can be effectively distributed to every corner of the room through ducting

Model
Air flow rate (1) m /h (max.) m3/h (med.) m3/h (min.) kW (max.) kW (med.) kW (min.) kW (max.) kW (med.) kW (min.) L/h kPa W (max.) W (med.) W (min.) Pa L/h kPa W A inches
3

010CW

015CW

020CW

025CW

030CW

040CW

050CW

060CW

Total cooling capacity (1) Sensible cooling capacity (1) Water flow rate Pressure drop Total heating capacity (2)
Static pressure

Water flow rate Pressure drop Power supply Power input Absorbed current Connection

510 480 410 2,66 2,64 2,54 2,04 1,98 1,83 455 14 3,34 3,2 2,85 50 455 12 71 0,30 3/4

730 530 460 4,78 3,78 3,39 3,52 2,7 2,39 819 45 5,22 3,98 3,52 50 819 24 102 0,43 3/4

1050 1040 850 6,02 5,98 5,17 4,36 4,33 3,69 1031 86 6,44 6,39 5,43 50 1031 74

1430 1750 1340 1390 1090 1120 7,25 8,77 6,93 7,43 5,97 6,3 5,31 6,52 5,06 5,46 4,32 4,6 1242 1503 125 86 7,85 9,72 7,46 8,1 6,34 6,78 50 150 1242 1503 99 53 230V 1 ph 50 Hz 148 173 421 0,65 0,74 1,90 3/4 3/4 3/4

1960 1740 1430 11,3 10,42 9,05 8,47 7,71 6,58 1936 79 12,8 11,64 9,92 150 1936 58 550 2,60 3/4

2620 2430 2210 14,5 13,78 12,87 10,74 10,13 9,39 2490 56 16,33 15,38 14,25 150 2490 43 670 2,90 3/4

3380 3110 2770 17,53 16,51 15,14 12,75 11,96 10,92 3004 81 19,33 18,1 16,5 150 3004 62 748 3,20 3/4

Note: Air flow and Performances referred to EUROVENT 6/3 conditions: 1. Cooling: Air temperature entering the unit: 27C d.b.; 19C w.b.; water inlet temperature: 7C; T 5K. 2. Heating: Air temperature entering the unit: 20C; water inlet temperature: 50C; water flow rate same as for cooling mode

Model
dB (A) (max) dB (A) (med) dB (A) (min)

010CW

015CW

020CW

025CW

030CW

040CW

050CW

060CW

33,0 31,0 30,0

37,0 34,0 32,0

38,0 35,0 33,0

40,0 37,0 35,0

49,0 45,0 43,0

51,0 47,0 45,0

53,0 50,0 46,0

55,0 52,0 50,0

MCC units are specifically designed for inside ceiling installation. Air mixing is well distributed in all space granting the best comfort. The small height makes unit ideal for inside ceiling installations where space is limited. A double drain pan prevents condensation drops

Model
Height Length Width Weight

010CW

015CW

020CW

025CW

030CW

040CW

050CW

060CW

mm mm mm Kg

261 765 411 17

261 905 411 21

261 1065 411 22

261 1200 411 25

370 919 589 39

370 1039 589 42

370 1289 589 54

370 1489 589 62

The new McQuay range of fan coils cassette offers an excellent conditioning comfort with an extremely easy installation. The elegant styled cabinet easily harmonizes with all interior fashion design while the attractive grille fully integrates the unit both on standard panel and on inside ceiling.

Model
Air flow rate (1) m /h (max.) m3/h (med.) m3/h (min.) kW (max.) kW (med.) kW (min.) kW (max.) kW (med.) kW (min.) L/h kPa W (max.) W (med.) W (min.) L/h kPa W A inches
3

15BW

20BW

25BW

30BW

020AW 025AW 030AW 040AW 050AW

Total cooling capacity (1) Sensible cooling capacity (1) Water flow rate Pressure drop Total heating capacity (2) Water flow rate Pressure drop Power supply Power input Absorbed current Connection

730 630 530 3,7 3,4 3,0 2,9 2,6 2,3 640 28 4,3 3,8 3,3 640 24 72 0,31 3/4

730 630 530 5,0 4,4 3,8 3,5 3,1 2,7 855 49 5,3 4,6 4,0 855 43 72 0,31 3/4

850 770 660 5,9 5,4 4,8 4,1 3,8 3,3 1007 82 6,1 5,6 4,9 1007 71 79 0,33 3/4

1030 1310 1380 920 1130 1180 810 1070 1070 6,8 7,2 8,4 6,3 6,5 7,5 5,6 6,2 6,9 4,8 5,3 6,1 4,4 4,7 5,4 3,9 4,5 5,0 1172 1239 1436 111 38 51 7,0 7,9 8,9 6,3 7,0 7,8 5,7 6,7 7,2 1172 1239 1436 96 33 44 230V 1ph 50 Hz 108 127 151 0,45 0,53 0,65 3/4 3/4 3/4

1560 1320 1210 9,6 8,4 7,8 6,8 6,0 5,6 1636 65 10,0 8,7 8,1 1636 56 164 0,69 3/4

1740 1540 1340 10,7 9,8 8,8 7,7 7,0 6,2 1840 80 11,1 10,0 8,9 1840 69 192 0,80 3/4

1840 1680 1540 11,9 11,1 10,4 8,4 7,8 7,3 2041 97 11,8 10,9 10,2 2041 84 253 1,08 3/4

Note: Air flow and Performances referred to EUROVENT 6/3 conditions: 1. Cooling: Air temperature entering the unit: 27C d.b.; 19C w.b.; water inlet temperature: 7C; T 5K. 2. Heating: Air temperature entering the unit: 20C; water inlet temperature: 50C; water flow rate same as for cooling mode

Model
dB (A) (max) dB (A) (med) dB (A) (min)

15BW

20BW

25BW

30BW

020AW

025AW

030AW

040AW

050AW

41,0 39,0 38,0

44,0 41,0 39,0

44,0 40,0 38,0

47,0 44,0 40,0

42,0 39,0 37,0

45,0 42,0 40,0

49,0 45,0 43,0

51,0 48,0 46,0

53,0 52,0 50,0

The anti-fungus and dual action ionizer/deodoriser filters enhance the air quality. Detection and diagnosis of any faults occurring in the unit is possible by blinking of the LED lights. Flexible control type selection in accordance with the installation requirement

Model
Height Length Width Weight

15BW

20BW

25BW

30BW

020AW

025AW

030AW

040AW

050AW

mm mm mm Kg

293 650 650 33

293 650 650 33

293 650 650 34

293 650 650 35

335 820 820 35

335 820 820 36

335 820 820 39

335 820 820 42

335 820 820 44

The unit comes with a built in high head drain pump. Condensate water can be pumped up to 500mm and drain out smoothly

The 4 way air discharge and air-swing function will greatly improve the air distribution and circulation in the room. Innovative design of highly efficient turbo fan producing air circulation in all directions

The Wall Mounted unit has an aesthetically stylish outlook and an elegant design easy to use where necessary to combine high performance and precise interior decoration. The swing mode enables the air to be distributed to every corner of the room. While providing a high flow rate, the random-pitched fan blade helps to reduce the air noise level.

Model
Air flow rate (1) m /h (max.) m3/h (med.) m3/h (min.) kW (max.) kW (med.) kW (min.) kW (max.) kW (med.) kW (min.) L/h kPa W (max.) W (med.) W (min.) L/h kPa W A inches
3

005FW

007FW

010FW

15FW

20FW

25FW

Total cooling capacity (1) Sensible cooling capacity (1) Water flow rate Pressure drop Total heating capacity (2) Water flow rate Pressure drop Power supply Power input Absorbed current Connection

340 290 240 1,4 1,3 1,1 1,2 1,1 0,9 214 3 2,2 1,9 1,6 214 3 23 0,10 1/2

340 290 240 2,0 1,8 1,6 1,5 1,3 1,2 304 6 2,4 2,1 1,8 304 5 23 0,10 1/2

460 510 400 460 330 390 2,8 3,5 2,6 3,2 2,2 2,8 2,1 2,5 1,9 2,3 1,6 2,0 436 553 15 25 3,5 4,0 3,1 3,6 2,6 3,1 436 553 13 21 230V 1 ph 50 Hz 25 25 0,11 0,11 1/2 1/2

820 730 630 5,0 4,9 4,3 3,7 3,5 3,1 839 27 5,7 5,1 4,5 839 23 53 0,23 1/2

990 830 650 6,2 5,4 4,4 4,5 3,9 3,2 925 18 7,0 6,0 4,8 925 16 57 0,24 1/2

Note: Air flow and Performances referred to EUROVENT 6/3 conditions: 1. Cooling: Air temperature entering the unit: 27C d.b.; 19C w.b.; water inlet temperature: 7C; T 5K. 2. Heating: Air temperature entering the unit: 20C; water inlet temperature: 50C; water flow rate same as for cooling mode

Model
dB (A) (max) dB (A) (med) dB (A) (min)

005FW

007FW

010FW

15FW

20FW

25FW

38,0 34,0 30,0

38,0 34,0 30,0

38,0 34,0 30,0

38,0 35,0 31,0

45,0 42,0 39,0

47,0 44,0 42,0

Dehumidification mode: a computerized control dehumidifies the surrounding without much change in temperature. The air intake grille can be easily removed and washed with clean water.

Model
Height Length Width Weight

005FW

007FW

010FW

15FW

20FW

25FW

mm mm mm Kg

290 815 179 10

290 815 179 11

290 815 179 12

290 815 179 12

306 1062 202 15

306 1062 202 15

3-stage air filtration: 1) Antifungus filter to remove dust in the air as well as bacteria proliferation 2) Ionizing filter to positively charge dust particles (0,01 micron) in the air while the negatively charged dust collector attracts them 3) Deodorizing filter to minimize unpleasant odors from sweat, cigarettes etc.

The compact LCD transmitter is able to operate the air conditioner unit within the distance of 9 meters. Fan motor speed can be set at low/medium/high or automatic. Sleep mode automatically increases set temperature since room temperature is lower at night thus achieving comfort surrounding. Air flow direction can be controlled automatically. Room temperature is controlled by electronic thermostat. The unit can be preset to on and off automatically for maximum of 15 hours by using timer on/off.

Maximises Efficiency Reduces Costs Saves Energy

T Th en he ntt e iin ntte elllliig ge c co on nttr ro oll tth ha att ffu ulllly y iin ntte eg gr ra atte es s tth he e s sy ys stte em m C Ch hiilllle er r+ +F Fa an nC Co oiill m ma ak kiin ng ge ea as sy y iitts s c co om mp plle ette ec co on nttr ro oll

MONITORING OF FCUS STATUS AND OVERRIDE FCUS SETTING ( ALL, GROUP OR INDIVIDUAL ) MONITORING OF MINI CHILLER STATUS DETERMINATION OF MINI CHILLER RUNNING MODE (BASED ON FCUS REQUEST) ALARM MINI CHILLER AND/OR FCU FAULT ALARM HISTORY SMART START (START CHILLER EARLIER BEFORE SCHEDULE) TIME SCHEDULE: 7 DAYS TIMER SCHEDULE, 4 TIMERS IN EACH DAY HOLIDAY SCHEDULE

We reserve the right to make changes in design and construction at any time without notice, thus the cover picture is not binding.

McQuay Italia S.P.A. S.S. Nettunense, km 12+300 00040 Cecchina (Roma) Italia Tel. (06) 937311 Fax (06) 9374014 E-mail: mcquay@mcquayitalia.com

Potrebbero piacerti anche