Sei sulla pagina 1di 24

1st Edition, January 2008 Property of Compaa Europea del Agua, S.A.

partial or total reproduction in any way is forbidden without explicit owner authorization. System features can change without notification, due to our innovation and improvement policy. Information shown is only for consultation.

Compaa Europea del Agua S.A. Polgono Industrial Rosanes C/ Alemania R.F. 21-25 08769 Castellv de Rosanes Barcelona - Spain Tel: +34 937 766 344 Fax: +34 937 741 104

DOMESTIC

COMMERCIAL

INDUSTRIAL

VALVE CONTROL

Softening
ELECTRONIC

Regeneration Samples

ELECTROMECHANICAL

MAX FLOW RATE

REGENERATION

CHRONOMETRIC CONTROL

VOLUMETRIC

SEMIAUTOMATIC DIRECTION

DOWN FLOW

UP FLOW

DELAYED

IMMEDIATE START

DELAYED WITH OPTION

VARIABLE BRINING

CONTINUOUS TWIN FUNCTIONING

SALT

Bi-Block (Keramis) Bi-Block (Fleck)


STANDARD HIGH FLOW

RESIN

Duplex (Keramis) Multi-Tank (Fleck)

WEIGHT

WHAT IS WATER SOFTENING? Softening is a process used to remove undesired minerals from water, mainly Calcium and Magnesium. For this process to occur, water must flow through a resin bed, where the ion exchange takes place.

SOFTENING CYCLE
During the softening cycle, calcium and magnesium ions contained in the water adhere to the resin causing sodium ions to be released in order to restore equilibrium. The degree of efficiency during the process depends on the type of resin applied.

STANDARD RESIN During the ion exchange process, the resin retains calcium and magnesium ions temporarily, releasing sodium ions in return. The spheres of the standard resin have an average diameter of 0,6 mm with great size differences between spheres. Standard resin has limited performance.

Resin during softening

VALVE

Regenerated resin

SOFT WATER

HARD WATER HIGH FLOW RESIN The latest innovation is the HIGH FLOW RESIN that allows maximun efficiency and performance. Its average diameter of 0,3 mm and its homogenous size create a greater contact surface.
RESIN TANK

The peak flow rate of the system increases fourfold generating water and salt savings of up to 20% and 15% respectively.
BRINE TANK

The water intake is driven towards the resin tank were it softens as it flows downward through the resin. The water then ascends from the bottom of the resin tank and is driven to the outlet valve.

REGENERATION EXPLAINED The softening cycle saturates the resin with Calcium and Magnesium ions. In order to restore initial properties a regeneration cycle must be performed.

REGENERATION CYCLE
During the regeneration cycle, brine flows through the resin bed exchanging calcium and magnesium ions for sodium ions.The resin recovers its softening capacity. This process will be more or less efficient depending on the chosen regeneration type.

Saturated resin

VALVE

DOWN FLOW

(1) BACKWASH

(2) BRINING

(3) FAST RINSE

(4) BRINE REFILL

Regeneration

The flow direction in the softening cycle is downward, so the upper part of the resin bed is the most saturated. The regenerant circulates throught the resin bed in the same direction at the service flow, from top to bottom, thereby dragging the highest concentration of impurities from the upper resin bed throughout the tank. This makes the quantity of water, brine and time needed to complete the process effectively very high.

The brine is suctioned and driven through the valve towards the bottom of the tank, where it flows through the resin bed until it reaches the outlet.

UP FLOW

(1) BRINING

(2) BACKWASH

(3) FAST RINSE

(4) BRINE REFILL

The flow directions during the service cycle and regeneration cycle are the opposite: The flow direction in the regeneration cycle is upward, so it produces a back wash that spands the resin bed, removes the upper level impurities in a direct way and regenerates the resin in an effective way. With this process, savings of up to 60% in water and up to 50% in regenerant can be obtained.
RESIN TANK BRINE TANK

The combination of both high flow resin and up flow regeneration increases performance of the system and reduces water and salt consumption during the regeneration cycle.

WHY SHOULD YOU CHOOSE A HIGH FLOW RESIN?


Use of the high flow resin allows reducing the size of the system, minimises regeneration time and increases savings in water and salt consumption, as you can see in the below example. The features of the equipment have been obtained considering household requirements and the chosen system type.
50 PERSONS PER HOUSEHOLD MAX FLOW RATE DAILY CONSUMPTION WATER HARDNESS

SYSTEM
RESIN
SYSTEM CAPACITY SYSTEM FLOW RATE

EQUIPMENT FEATURES
SOFTENER
SIZE savings savings savings savings REG. CYCLE

REGENERATION

REGENERATION CYCLE

TYPE

TYPE

RESIN VOLUME VESSEL SIZE

WATER CONSUMPTION

SALT CONSUMPTION

TIME REGENERATION

STANDARD

6000 L x L RES. / F 50 L / (h x L RES.)


H

30 L

4 DAYS

0%
2250 L

0%
45 Kg

0%
1h 30min

0%

10 x 35

STANDARD

6000 L x L RES. / F 50 L / (h x L RES.)


H

35 L

5 DAYS

0%
1050 L

53 %
21 Kg

53 %
1h 5min

19 %

10 x 35

HIGH FLOW MICRO MONOSPHERE

6600 L x L RES. / F 200 L / (h x L RES.)


H

15 L
10 x 17

2 DAYS

50 %
787 L

65 %
15 Kg

67 %
32min

60 %

Compact domestic softener *Resin tank outside the softeners cabinet, independent brine tank with removable lid. *UF models include Up-Flow regeneration piston resulting in savings in water and regenerant. *Electronic display.

Power supply 230V/50Hz (110V/60Hz Opt.) Connections 1 G Operating pressure 1,8 - 8 bar Water temperature 5-45C Dimensions (A x B x C) 1150 x 430 x 480 680 x 430 x 480 By- pass Optional

200 E-DF
A-403232 MODEL FORUM

220 E-UF
A-403203 FORUM

300 E-DF
A-403332 FORUM

350 E-UF 100 E-HF/UF 150 E-HF/UF


A-403303 FORUM A-403010 FORUM A-403015 FORUM

VALVE

CONTROL

(l/h) MAX FLOW RATE

1000

1100

1500

1750

1500

2250

CONTROL

REGENERATION

DIRECTION

START

3,6 (Kg/REG) SALT CONSUMPTION

2,2

5,4

3,5

0,9

1,35

(Litres) CAPACITY

20

22

30

35

10

15

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

120

132

180

210

66

99

WEIGHT (Kg)

39,5

41,5

48

53

20

25

Compact domestic softener *Resin tank outside the softeners cabinet, independent brine tank with removable lid. *UF models include Up-Flow regeneration piston resulting in savings in water and regenerant. *Electronic display.

VALVE

Power supply 120V/50Hz (110V/60Hz Opt.) Connections 1 G Operating pressure 1,5 - 6 bar Water temperature 5-45C Dimensions (A x B x C) 1100 x 350 x 620 710 x 350 x 620 By- pass Optional

200 DF
A-404232 MODEL OLYMPIA

220 UF
A-404202 OLYMPIA

300 DF
A-404332 OLYMPIA

350 UF
A-404302 OLYMPIA

100 HF/UF 150 HF/UF


A-404010 OLYMPIA A-404015 OLYMPIA

CONTROL

(l/h) MAX FLOW RATE

1000

1100

1500

1750

1500

2250

CONTROL

REGENERATION

DIRECTION

START

3,6 (Kg/REG) SALT CONSUMPTION

2,2

5,4

3,5

0,9

1,35

(Litres) CAPACITY

20

22

30

35

10

15

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

120

132

180

210

66

99

WEIGHT (Kg)

39

41

46

51

23,5

28,5

Compact domestic softener *Resin tank outside the softeners cabinet, independent brine tank with removable lid. *UF models include Up-Flow regeneration piston resulting in savings in water and regenerant. *Electronic display.

Power supply 230V/50Hz (110V/60Hz Opt.) Connections 1 G Operating pressure 1,8 - 8 bar Water temperature 5-45C Dimensions (A x B x C) 1170 x 430 x 480 700 x 430 x 480 By- pass Optional

200 DF
A-714003 MODEL VK DF

220 UF
A-714002 VK UF

300 DF
A-714001 VK DF

350 UF
A-714000 VK UF

100 HF/UF 150 HF/UF


A-714004 VK UF A-714112 VK UF

VALVE

CONTROL

(l/h) MAX FLOW RATE

1000

1100

1500

1750

1500

2250

CONTROL

REGENERATION

DIRECTION

START

3,6 (Kg/REG) SALT CONSUMPTION

2,2

5,4

3,5

0,9

1,35

(Litres) CAPACITY

20

22

30

35

10

15

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

120

132

180

210

66

99

WEIGHT (Kg)

40

42

48,5

53,5

20

25

Compact domestic softener *Resin tank integrated in the softeners cabinet, brine tank with removable lid. *SE models come with white softener cover. *LOG models allow automatic regeneration interval calculation according to water hadness and resin volume. *The Keramis valve models incorporate a hydraulic distribution system with ceramic core.

200C
Power supply 100-240Vac / 50-60 Hz (Keramis) 230Vac / 50-60Hz (110V/60Hz Opt.) Connections 1 3/4 (85C y 120C Keramis) Operating pressure 1,5 - 6 bar Water temperature 5-45C Dimensions (A x B x C) 1174 x 378 x 515 By- pass Optional FLECK AUTOTROL KERAMIS
K63B-1 DF A-400212

200V
5600 DF* A-400203 5000 SE DF A-400210 LOGIX 255/760 A-400204 K63B-3 VOL DF A-400211

220V UF
5000 SE UF A-400214

300C

300V
5600 DF* A-400303 5000 SE DF A-400311 LOGIX 255/760 A-400305 K63B-1 VOL DF A-400313

350V UF
5000 SE UF A-400315

K68A-3 VOL UF A-400213

K63B-1 DF A-400312

K68A-3 VOL UF A-400314

VALVE

CONTROL

(l/h) MAX FLOW RATE

1000

1000

1100

1500

1500

1750

CONTROL

REGENERATION

DIRECTION

START

3,6 (Kg/REG) SALT CONSUMPTION

3,6

2,2

5,4

5,4

3,5

(Litres) CAPACITY

20

20

22

30

30

35

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

120

120

132

180

180

210

WEIGHT (Kg)

35

35

37

42

42

47

Compact domestic softener *Resin tank integrated in the softeners cabinet, brine tank with removable lid. *SE models come with white softener hood. *LOG models allow automatic regeneration interval calculation according to water hadness and resin volume. *The Keramis valve models incorporate a hydraulic distribution system whith ceramic core.

85C
FLECK AUTOTROL KERAMIS Power supply 100-240Vac / 50-60 Hz (Keramis) 230Vac / 50-60Hz (110V/60Hz Opt.) Connections 1 3/4 (85C y 120C Keramis) Operating pressure 1,5 - 6 bar Water temperature 5-45C Dimensions (A x B x C) 680 x 378 x 515 By- pass Optional
K65B-1 DF A-714203

SE 85V
5600 DF* A-714010 5000 SE DF A-400001 LOGIX 255/760 V A-714013

100V UF
5000 SE UF A-400006

SE 120V
5600 DF* A-400158 5000 SE DF A-400003 LOGIX 255/760 V A-400157 K65B-1 VOL DF A-400154

120C

150V UF
5000 SE UF A-400004

K68A-3 VOL UF A-400156

K65B-1 DF A-400156

K68A-3 UF A-400153

VALVE

CONTROL

(l/h) MAX FLOW RATE

450

450

500

600

600

750

CONTROL

REGENERATION

DIRECTION

START

1,5 (Kg/REG) SALT CONSUMPTION

1,5

2,1

2,1

1,5

(Litres) CAPACITY

8,5

8,5

10

12

12

15

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

51

51

60

72

72

90

WEIGHT (Kg)

18

18

19,5

21,5

21,5

24,5

Compact domestic softener *Resin tank integrated in the softeners cabinet, independent brine tank with rotating lid. *Keramis valve with hydraulic distribution system and ceramic core. *Electronic multi-colour display. *Auxiliary voltage free contact.

Power supply 280-110V / 50-60Hz Connections 1 G Operating pressure 1,5 - 6 bar Water temperature 5-45C Dimensions (A x B x C) 635 x 310 x 625 By- pass Included

85 V
A-406400 MODEL K63B-3K

100 V
A-406401 K63B-3K

120 V
A-406403 K63B-3K

150 V/UF 100 V HF/UF 150 V HF/UF


A-406405 K68A-3K A-406402 K68A-3K A-406404 K68A-3K

VALVE

CONTROL

(l/h) MAX FLOW RATE

425

500

600

750

1500

2250

CONTROL

REGENERATION

DIRECTION

START

1,5 (Kg/REG) SALT CONSUMPTION

1,8

2,1

1,5

0,9

1,35

(Litres) CAPACITY

8,5

10

12

15

10

15

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

51

60

72

90

66

99

WEIGHT (Kg)

18

19,5

21,5

24,5

19,5

24,5

Compact domestic softener *Resin tank integrated in the softeners cabinet, brine tank with removable lid. *SE models incorporate electronic programmer.

Power supply 250V/150Hz (110V/60Hz Opt.) Connections E/S 1 G Operating pressure 1,8 - 8 bar Water temperature 5-40C Dimensions (A x B x C) 1150 x 300 x 430 660 x 300 x 430 By- pass Optional

85 VOL 100 VOL UF 200 VOL 220 VOL UF 300 VOL 350 VOL UF
A-409101 MODEL FLECK 5000 SE A-409132 FLECK 5000 SE A-409201 FLECK 5000 SE A-409232 FLECK 5000 SE A-409301 FLECK 5000 SE A-409332 FLECK 5000 SE

VALVE

CONTROL

(l/h) MAX FLOW RATE

425

500

1000

1100

1500

1750

CONTROL

REGENERATION

DIRECTION

START

1,5 (Kg/REG) SALT CONSUMPTION

3,6

2,2

5,4

3,5

(Litres) CAPACITY

8,5

10

20

22

30

35

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

51

60

120

132

180

210

WEIGHT (Kg)

20

21

30

32

40

45

Compact domestic softener *Resin tank integrated in the softeners cabinet, brine tank with swinging lid. *Integrated mixing valve. *LCD display.

110 VOL
A-714015 MODEL Power supply 230V/50Hz (110V/60Hz Opt.) Connections E/S 3/4 G Operating pressure 1,8 - 8 bar Water temperature 5-30C Dimensions (A x B x C) 590 x 370 x 180 490 x 370 x 180 By- pass Optional 110 VOL

PLUS VOL
A-714195 110 PLUS VOL

VALVE

CONTROL

(l/h) MAX FLOW RATE

750

1100

CONTROL

REGENERATION

DIRECTION

START

0,4 (Kg/REG) SALT CONSUMPTION

0,6

(Litres) CAPACITY

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

26

40

WEIGHT (Kg)

9,5

12

Compact softener for commercial use *Resin tank integrated in the softeners cabinet, independent pull-out brine tank. *Hydraulic distribution Keramis valve with ceramic core. *Multi-colour display. *Auxiliary voltage free contact.

Power supply 230-110V/50-60Hz Connections 3/4 G Operating pressure 1,5 - 6 bar Water temperature 5-45C Dimensions (A x B x C) 585 x 282 x 510 By- pass Included in VOL models Optional in CR models

85 C
A-406452 MODEL K65B-1

85 V
A-406451 K65B-3

85 SA
A-406453 K65C

100 SA/UF 100 V/UF


A-406450 K69C A-406454 K69A-3

VALVE

CONTROL

(l/h) MAX FLOW RATE

425

425

425

500

500

CONTROL

REGENERATION

DIRECTION

START

1,5 (Kg/REG) SALT CONSUMPTION

1,5

1,5

(Litres) CAPACITY

8,5

8,5

8,5

10

10

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

51

51

51

60

60

WEIGHT (Kg)

16

16

16

19,5

19,5

Industrial Bi-Block (Keramis)

MODEL

Keramis K63B-3

Keramis K68A-3

Keramis K74A

Power supply 100-240Vac / 50-60Hz Connections 1 Operating pressure 1,5-6 bar Water temperature 5-45C Dimensions (A x B x C) From 640 x 205 x 440 Up to 1870 x 405 x 1670 Tank From 540 x 410 Up to 1140 x 750

VALVE

CONTROL

0,42 - 5 (m3) MAX FLOW RATE

0,5 - 6

0,5 - 6

CONTROL

DIRECTION

REGENERATION

START

1,53 - 18 (Kg/REG) SALT CONSUMPTION 50 - 300 (Litres) BRINE TANK VOLUME

0,9 - 12,5

13,5 - 36

50 - 300

300 - 750

8,5 - 100 (Litres) CAPACITY

8,5 - 125

75 - 200

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

51 - 600

51 - 750

450 - 1200

WEIGHT (Kg)

15 - 110

15 - 140

170 - 460

Industrial Bi-Block (Fleck)


Fleck 2850, 2900, 3900, 5600 DF Fleck 2850SE, 2910NT,3900NT, 5000SE, 7700 DF Fleck 2850SE, 2910NT, 3900NT, 5000SE UF

MODEL Power supply 230Vac / 50Hz Connections 1 up to 3 Operating pressure 2-8 bar Water temperature 5-45C Dimensions (A x B x C) From 640 x 205 x 440 Up to 2530 x 1100 x 2130 Tank From 540 x 410 Up to 1650 x 1100

VALVE

CONTROL

0,42 - 50 (m3) MAX FLOW RATE

0,42 - 50

0,9 - 30

CONTROL

DIRECTION

REGENERATION

START

1,5 - 180 (Kg/REG) SALT CONSUMPTION 50 - 1100 (Litres) BRINE TANK VOLUME

1,5 - 180

1,8 - 60

50 - 1100

80 - 500

8,5 - 1000 (Litres) CAPACITY

8,5 - 1000

18 - 600

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

51 - 6000

51 - 6000

108 - 3600

WEIGHT (Kg)

15 - 1200

15 - 1200

25 - 680

Industrial Duplex (Keramis)


Keramis K73 A/D

MODEL

Power supply 100-240Vac / 50-60Hz Connections 1 Operating pressure 1,5-6 bar Water temperature 5-45C Dimensions (A x B x C) From 640 x 205 x 440 Up to 1870 x 405 x 1670 Tank From 540 x 410 Up to 1140 x 750

VALVE

CONTROL

1,3 - 5 (m3) MAX FLOW RATE

CONTROL

DIRECTION

REGENERATION

START

3,6 - 18 (Kg/REG) SALT CONSUMPTION 80 - 300 (Litres) BRINE TANK VOLUME

20 - 100 (Litres) CAPACITY

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

120 - 600

WEIGHT (Kg)

60 -220

Industrial Multi-Tank (Fleck)


Power supply NT models control up to 4 tanks, in alternate or simultaneous operation. 100-240Vac / 50-60Hz Connections 1 MODEL Operating pressure 1,5-6 bar Water temperature 5-45C Dimensions (A x B x C) From 640 x 205 x 440 up to 1870 x 405 x 1670 CONTROL Tank From 540 x 410 up to 1140 x 750 TWIN 9000, 9100, 9500 TWIN 2910NT*, 3900NT*, 9000SE, 9100SE, 9500SE

VALVE

1 - 15 (m3) MAX FLOW RATE

1 - 60

CONTROL

DIRECTION

REGENERATION

START

3,6 - 54 (Kg/REG) SALT CONSUMPTION 80 - 850 (Litres) BRINE TANK VOLUME

3,6 - 216

80 - 1500

20 - 300 (Litres) CAPACITY

20 - 1200

RESIN

TYPE (m3 / F) SYSTEM CAPACITY

120 - 1800

120 - 7200

WEIGHT (Kg)

60 - 660

60 - 1900