Sei sulla pagina 1di 12

Characteristics

net-line substation automation


Version:

setIT V 4.004

17.12.09

The integrated configuration tool setIT was extended with a fully graphical dialogue for the assembly of components. This function allows an even faster integration of substation automation and telecontrol. It also eases the handling and gives you an quick overview of the systems assembly.

Achieving aims faster


Furthermore setIT V4.004 brings extended functionality such as: Selective linkage to protective equipment Processing of archives with variable memory depth Optimised GPRS communication Integration of the newest series5 devices High-Speed-Download* Configuration via USB-Stick* up to 2 GB of archive memory* Diagnosis via Web-Server*

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc 17.12.2009

Release note - Differences to V 3.0


Graphical user interface for configuration of all base systems visual assembly of serial interfaces and I/Os Selective coupling of protective equipment Preprocessing of process data in the process image Merging addresses of protective equipment into address room and structure of control centre Processing of archives with variable memory depth modified memory management with automatic or manual partition Optimised GPRS communication IEC 60870-5-104 for VPN-Tunnel with GPRS Integration of ENET-2 card for optimised TCP/IP timing at GPRS Optimisation of the symmetric IEC 60870-5-101 driver for GPRS Complete integration of autarky compact systems and data logger aucolog into telecontrol with IEC 60870-5-101/-104 protocol Negative confirmation of commands and desired values with time tag, in the case that the respective time spans have been exceeded. Validation of set points at coupling of external devices can be activated via status word Adjustment of idle condition for single-point information and commands Step position information with validity detection 8 bit or 32 bit Logging of process data in telecontrol report Remote diagnose with an external front-end station via switched telephone line, LAN or field interface with IEC -101/-104 protocol or directly via switched telephone line or LAN with PU protocol UNIP Integration of series5

net-lineFW-5-BT

net-line FW-5-BT with extension cards

net-line FW-50-4 in housing BGT-S

net-line FW-50 e.g. pure router in BGT-M

net-line FW-50-14 in housing BGT-L

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc Subject to modification17.12.2009

Further functions for series5 systems* systems*:


High-speed-download USB download and diagnose via USB interface FTP download and diagnose via Ethernet LAN http Stations update via Web page Hand over of configuration with USB memory stick Saving operating system, firmware and configuration on USB memory stick Batch control Job processing of stick information for each station according to adjustment in setIT Read out of status after update Archive read out over web page and USB memory stick Dynamic creation of web pages for web server in line with the configuration of process data Integration of several IEC 60870-5-104 substations over one interface at the master station Partyline Support of fast information input < 1 ms with 16IE-5 card by dint of interrupt processing with minimised latencies Quick LAN connection due to copper or fibre optic switches SWI1-1: 4* Tx or SWI1-2: Fx + 2 * Tx Cascading of racks via Ethernet with integrated switch New rack sizes for larger capacity BGT-S for up to 4, BGT-M for up to 7 and BGT-L for up to 14 I/O cards Up to 9 communication components 4 serial, 2 switch- and max. 3 fieldbus components NTP-Protocol for time synchronisation according to IEC 61850 Platform for integration of IEC 61850 coupling of protective equipment

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

General information
Open & standard communication for New installation as system solution or component Extension usually in the field of power system control and industry Integration of protective equipment via -103 or external components with fieldbus Quick and easy configuration with setIT Very fast realisation of your project due to easy handling Menu, context menus, mouse- and hotkey functions Learning the ropes quickly be dint of tree structures and well established handling processes from the MS Office world (copy/paste, do/undo) Avoiding faulty entries with dynamic menus and context sensitive entry masks only only operative components, options and combinations are selectable Hand over of mutual configurations single-point-of-entry High flexibility in terms of topology the telecontrol network is adjustable to almost every existing structure Fast modification and extension of installations Types of interfaces, protocols, station types Future proof with modern platform and hardware Windows based configuration tool with state of the art GUI setIT support all characteristics of System-4 and series5 hardware FW-4, FW-40, FW-10-S4, BGT-4000, FW-5, FW-50 etc. Active advancements, maintenance and optimising Download and Upload from operating system, system software, configuration and add-on modules including version control Saving configuration in access data base Import and export of configuration with csv file for documentation or further editing with Excel Recording of system events Separately loadable system report Logging of process data changes in telecontrol report Reports separately loadable as csv-file Memory management and archive processing Processing of archives with variable memory depth modified memory management with automatic or manual partition Quick ROI due to fair license system Free 30 days demo-version with optional extension. Single user license, multi user license and company license

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Communication
Communication according to standard protocols. IEC 60870-5-101 IEC 60870-5-102 IEC 60870-5-103 IEC 60870-5-104 Serial coupling with dedicated line Routing of data from remote meter reading Coupling of protective equipment Coupling with TCP-IP /LAN

Selective coupling of protective equipment via IEC 60870-5-103 Preprocessing of process data in the process image Merging addresses of protective equipment into the address room and structure of the control centre Rapid coupling to control centres with IEC 60870-5-10x protocols supporting ProCoS, PSI, STS/BTC, SAT, ids, ABB, repas ... OPC server supported Handover of station names, names of process points and parameter in namespace of OPC Supervision name semantic respectively automatic conversion with underlining support of redundant OPC-Server Free cross-connection in network free linkage of information inputs to the outputs of the network overall cross-connection by dint of control centre or router Structured station- and object addressing in up to 6 levels Switched telephone line & remote diagnostics via telephone line switchable login procedure name, password Translation form IEC 60870-5-101 to IEC 60870-5-104 by router On site integration of PLC functions with codeIT Optimised GPRS communication GPRS with VPN Tunnel directly over IEC 60870-5-104 Optimisation of the symmetric IEC 60870-5-101 driver for GPRS

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Integration & Adaption


flexible types of communication are supported: direct coupling to control system point-to-point or LAN mode Star coupling point-to-point mode to router LAN Industrial Ethernet, TCP/IP, pulse code modulation Partyline Networks and loop lines multipoint variable structures in complex networks and cascading at subordinated networks routers are the connection to control centre or telecontrol knot Dial up connection via analogue link, ISDN or GSM with switchable protection against remote access Multiple link to control centres Filtering of data points with transmission lists for a selective transmission to control system Transformable address structures for a separate structure of the secondary control system Time synchronisation via DCF and GPS receiver Flexible fieldbus coupling and gateways for the implementation of external devices Profibus-DP master/slave Modbus RTU master/slave Modbus RTU master/slave MPI 3964R/RK512 Free allocation of external devices/components external components are integrated as station objects process data are allocated with free declaration of LEDs process data of external devices are provided just like system-own process data Complete integration of autarky compact systems and data logger aucolog into telecontrol with IEC 60870-5-101/-104 protocol

Integration of autarky objects in interconnected systems

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Additional functions in the section of interconnected systems and substation substation automation
Command termination;via EVU special cards with 1 of n monitoring Single- and double commands 1,5 and 2 pole Adjustable for each command: post command lag time, suppression of imperfection, coupling resistance measuring circuit test from 10 to 20 k Cascading of several racks with IEC profile Administration of of up to nine racks at only one station address 1 of n monitoring of several racks At cascaded systems large command groups can be assembled. The EVU-X cards loops the interlock signals of the 1 of n monitoring to the implemented racks. Process image in telecontrol router Telecontrol router are able forward the data of subordinated stations default value generation at control commands Control commands can be set to an individual default status in the case of disturbed communication or system start. Rapid acquisition of measurands (max. 1 kHz pulses) with the intelligent counter card CNT-1 Logging of measurands with external pulse inputs at the device Time synchronised logging is available due to external control signals. Binary step position information, BCD and 32 bit Step position information can be directly linked with 32 bit.

Intuit configuration with setIT

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Cascaded stations for large capacities

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Security
Redundancy functions Support of redundant control centre Twinned master stations easily settable watchdog monitors the functions of the master stations and autarky switches hot/standby mode Quick loop line over baseband modem or WT96 as daisy-chain Security at short-circuit, line interruption and station- or modem breakdown Redundancy of switched telephone line Preferred interface, alternative numbers, prioritisation System information provide station status and internal error messages as binary single-point information Combining system information to group indication Logical linkage without PLC layer Cross-connection of system information System information may be handed over as output information to any station System history logs all station internal processes Archiving of reports in the case of communication error Default value generation at outputs in the case of communication error Management of system- and configuration version Optical marker for new system- / configuration versions after generating Control of station and version access prior to download

Twinned master stations in hot/standby operation

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Support at diagnostics & project planning


Comprehensive diagnostics and help functions are already integrated Online help provides a complete manual context sensitive forwarding to information with F1, search function Indication of connection status of interconnected station and process data states scaled or in plain text Quick correction of configuration errors Link to entry masks during generating Extended diagnostics with integrated telegram analyser (optionally) Recording of data transmission and receiving in substation is possible without additional devices Trigger functions Start/stop or marking of character strings Logging as csv- file in a revolving archive Memory management of csv-files HTML export for an easy transfer of the recording Chronometry and indication of receiving errors Online switching of view Data flow analysis Exchange and distribution of station's/router's data Follow up of the router's information paths Extended help at installation Analysis of coverage New value message Report for documentation printable or as pdf-file List for quick overview of prior indications

Integrated interface monitor (optionally)

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Types of communication
Modes point-to-point Partyline Star operation Loop mode Concentrator connection & routing Transmission routes Dedicated lines LAN networks Dial-up links Radio communication networks (in development) GSM - Transmission GPRS if the provider complies with the requirements Cause of transmission Spontaneous at changes or reaching limit values Cyclic queried by GA in background transmission of integrated totals inside the interval spontaneously and synchronous, from 12 s to 8 hours

Integration and communication of telecontrol and substation automation to control centre

* Performance of series5 2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

Supported types of process data


Inputs Single-point information Single-point information Step position information 7/8/32 bit, binary, BCD Measured values 8/12/16/32 bit Integrated total inputs 16/32 bit System information Group indication with logical connection Cumulative values equally spaced interval values from 1 to 60 min Checkback definition command termination with DSO card Outputs Single commands Double commands Regulating step command Set points 8/12/16/32 bit Integrated total outputs 16/32 bit Cross-connection & etc. Single point information in control direction Double information in control direction System information in control direction Measurand in command direction Integrated total cross-connection 16/32 bit Interval data, Interval-/ alarm-/ operation archive

setIT's easy structure of and configuation

2009 SAE IT-systems GmbH & Co. KG

Subject to modification

17.12.2009