Rotary cam switches

1769

VY1001

000518

Technical characteristics
Switch type Rated insulation voltage VDE 0110 V VY 10 750 600 10 16 10 10 2.5

VY 20 660 600 20 25 20 26 4

VY 40 750 600 50 50 40 50 10

VY 80 660 600

VY 125 660 600

VY 200 660 600

VY AR 16 660 600

CSA 22-2-14 V UL 508 AC/DC NFC 63130 A A A A mm


2

ENTRELEC cam switches are designed according to the requirements of the following standards : IEC 408, IEC 337, NBN 222, VDE 0660, VERITAS Bureau, CSA 22-2 N 14, UL 508, GL 91 552 HH - 558 HH, NFC 63-130/140. They carry the following approvals:

16 80 80 80 25 0 25 x 104 125 125 125 50 0 25 x 104 200 250 200 M 10 bolt on flange 5 x 104 2 x 2,5 20

LR 23701 for VY 10 to 200 UL file N 57541 for VY 20 to 200 file N 66 494 for VY 10 All switches are rated 600 VAC/DC nonswitching, at rated current. ASE, VERITAS Bureau, CEBEC, GL, FIN.ELEK. INSPEKT, Lloyds approval (for VY 40 - 80 - 125 - 200).

Thermal current

IEC 408 VDE 0660 CSA 22-2-14 UL 508

Max. cross section of conductors Mechanical life (number of on-off operations) Electrical life (number of on-off operations) Making capacity 380-415 V 220-660 V 600-660 V Breaking capacity tested in accordance with IEC 408 class AC 3 220-240 V 380-415 V 500-550 V 600-660 V

AWG

12 1 x 106 5 x 104

12 1 x 106 5 x 104 160 100 128 128

6 105

1 x 106 Possibility to connect a link with the same cross-section. 5 x 104

25 x 103 125 x 102 125 x 102 25 x 102 300 175 800 240 500 250 800 500 250 200 3200 6 3.5 1000 600 250 200 5500 10 7

Higher ratings are available. Contact us.

A A A A A A

87 50 70 70

800

800

1000

40 200

72 400

140 1000 6 3.5

200 2100 6 3.5

One-second rating A (max. cross-section of conductors) Max. short circuit current withstand with switch closed Max. short circuit current withstand at making KA peak KA peak

AC performance
Switch type Utilization category according to IEC 408 and IEC 337-1 AC1-AC21
SINGLE- PHASE 220 V 240 V

VY 10 P le kW A P le kW A 10 1.1 8 3

VY 20 P kW le A 20 20 16 12

VY 40 P kW 9.6 4 5.5 le A

VY 80 P kW le A

VY 125 P kW le A

VY 200 P kW le A 200

VY AR 16 P le kW A 12

The power ratings given in the table (left) are for standard motors as shown on the rating plates. They allow for a normal power factor and the efficiency corresponding to each category. The rated values of the ENTRELEC switches correspond to the electrical input power of the motor and are thus greater than those corresponding to the mechanical power.

50 19.2 80 29.8 125 48 30 40 11 11 80 18.5 100 30 80 13 80 17

AC3-AC23 AC4 AC11 AC1-AC21

165 1.5 9.8 100

0.75 6 6 10 1.5 1.1 6 5 5 10 2.2 8.7 1.5 6 10 4 1.5

2.2

20 16.6 50 33.2 80 4 3 16 10 10 20 16.6 50 33.2 80 4 3 16 12 7.5 11 30 40 22 22 80 80 5.5 10

52 125 83 22 17

200 75 60

380 V 415 V

AC3-AC23 AC4 AC11 AC1-AC21

20 18.5 55 18.5 63 38 13 50 15 50

52 125 83 37 125 55 22 80 37

200 165 2.2 125

12

220 V 240 V

AC3-AC23 AC4 AC1-AC21

20 28.7 50 57.5 80 16 15 30 30 22 76 22 15 83 63 50

90 125 143 200 30 22 63 50 40 30 75 60 4

12 8.5 - VY 10 to VY 200 switches are equipped with silver contacts. 4 6.5 Minimum utilization characteristics: - Standard silver.

380 V 415 V

THREE-PHASE

AC3-AC23 AC4 AC1-AC21

8.5 7.5 6 10 5.5

12 18.5 38 20 38 15 15 40 23 25

80 119 125 190 200 31 25 22 15 31 25 22 15 31 25

500 V 550 V

AC3-AC23 AC4 AC1-AC21

4 1.5

5 4 10

7.5 5.5

10 8

20 41.5 40 7.5 5.5 10 8

80 130 125 208 200 3 3.8 Minimum power Minimum voltage Minimum current : 0.5 W or VA :5V : 50 mA

600 V 660 V

AC3-AC23 AC4

4 1.5

5 4

15 17.5 18.5 25 18.5 25 18.5 25 11 20 11 20 11 20 11 20

1770

VY1002

000518

Technical characteristics
AC performance
Utilization category according to UL 508 120 V 200/208 V SINGLEPHASE 240 V 480 V 600 V 120 V 200/208 V THREEPHASE 240 V 480 V 600 V Utilization category according to CSA 22-2-14 240 V THREEPHASE 300 V 600 V 3 VY 10 HP 2 5 7.5 25 30 50 3 VY 20 HP 2 5 5 10 3/4 2 VY 10 HP 1/3 VY 20 HP 1 VY 40 HP 2 5 5 10 15 5 10 10 20 25 VY 40 HP 15 VY 80 HP VY 125 HP VY 200 VY AR 16 HP HP 10 25 30 40 15 30 40 50 15 30 40 50 3 5 3 VY 80 HP 7.5 15 15 VY 125 HP 10 20 20 VY 200 VY AR 16 HP HP 10 20 20 1.5 0.5

overload curves at max. conductor cross-section

tr.: no-load time. tw.: overload time. The period tw + tr is repeated until the temperature at the terminals reaches a steady 70C (158F), the permissible limit according to IEC 408.
NOTE: max. permissible ambient temperature range for all switches is: -30C (-22F) to +60C (140F).

The characteristics above are given for information only and can be changed without notice.

1771

VY1003

000921

Technical characteristics
Maximum switching voltage per contact on DC
Utilization category Rated utilization current A 1 2 4 5 10 16 20 25 DC 1 Resistive load 30 40 50 60 80 100 125 150 175 200 1 2 4 5 10 16 20 25 DC 21 30 40 50 60 80 100 125 150 175 200 1 2 4 5 10 16 DC 2 DC 3 DC 4 DC 5 DC 22 DC 23 Inductive load 20 25 30 40 50 60 80 100 125 150 175 200 145 105 145 105 145 105 90 85 75 68 63 58 54 45 145 105 90 85 75 68 63 58 54 45 40 36 30 145 105 90 85 75 68 63 58 54 45 40 36 30 22 18 190 145 100 85 70 190 145 100 85 70 225 160 120 110 90 85 80 75 72 68 225 160 120 110 90 85 80 75 72 68 64 60 54 225 160 120 110 90 85 80 75 72 68 64 60 54 48 43 Maximum voltage per contact (V) VY 10 220 180 115 95 85 VY 20 220 180 115 95 85 VY 40 250 220 160 120 105 100 95 90 85 80 VY 80 250 220 160 120 105 100 95 90 85 80 75 70 65 VY 125 250 220 160 120 105 100 95 90 85 80 75 70 65 60 55 VY 200 250 220 160 120 105 100 95 90 85 80 75 70 65 60 55 52 48 45 225 160 120 110 90 85 80 75 72 68 64 60 54 48 43 38 34 30 145 105 90 85 75 68 63 58 54 45 40 36 30 22 18 14 12 10 VY AR 16 UL/CSA All switches rated at 600 VDC nonswitching consult us for details. For maximum switching voltage per contact, refer to this table.

1772

VY1004

000518

Technical characteristics
Utilization categories for switches on AC
Utilization category

le = nominal current
Current Normal conditions Fault conditions Make Break Power factor cos 0.95

Typical applications Make Break

AC 1 AC 2 AC 2'

Noninductive or slightly inductive loads, resistance furnaces Slip-ring motors: Starting, plugging Squirrel-cage motors: Starting, switching off motors during running Squirrel-cage motors: Starting, plugging, inching*1 le 17 A 17 A le 100 A le > 100 A le 17 A 17 A < le 100 A le >100 A

le*

le le 2.5 le

1.5 le

1.5 le

IEC 408 App.C. VDE 0660 part 1/8.69 DIN 57660 part. 107

2.5 le

4 le 10 le 10 le 8 le 12 le 12 le 10 le

4 le 8 le 8 le 6 le 10 le 10 le 8 le

0.65 0.65 0.35 0.35 0.65 0.35 0.35

AC 3

6 le

le

AC 4

6 le

6 le

* 1/ Inching : energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. Plugging : stopping by reversing motor primary connections while the motor is running. * 2/ le : rated operational current.

AC 20
IEC 408 App.C. DIN 57660 part. 107

Connecting and disconnecting under no-load conditions Switching of resistive loads including moderate overloads Switching of mixed resistive and inductive loads, including moderate overloads Switching of motor loads or other highly inductive loads Control of electro-magnets Control of electro-magnets le 17 A 17 A < le 100 A le >100 A

_ 1.5 le 3 le 10 le 10 le 8 le

_ 1.5 le 3 le 8 le 8 le 6 le 10 le 11 le

_ 0.95 0.65 0.65 0.35 0.35 0.7 0.7

AC 21 AC 22

AC 23

VDE 0660 part 2/8.69 IEC 337-1

AC 11 AC 11

10 le 10 le

le le

10 le 11 le

Utilization categories for switches on DC


Current Utilization category Normal conditions Typical applications Make Break Make Break Fault conditions L/R Time constant 1 ms

VDE 0660 part 2/8.69

DC1

Noninductive or slightly inductive loads, resistance furnaces starting switching off motors during running Shunt motors: starting plugging inching starting switching off motors during running Series motors: starting plugging inching Connecting and disconnecting under no-load conditions Switching of resistive loads, including moderate overloads Switching of mixed resistive and inductive loads including moderate overloads (e.g., shunt motors) Switching of highly inductive loads Control of electro-magnets

le

le

1.5 le

1.5 le

DC 2
IEC 408 App.C. VDE 0660 part 1/8.69 DIN 57660 part. 107

le 2.5 le 2.5 le 4 le 4 le 2.5 ms

DC 3

DC 4

le 2.5 le 2.5 le 4 le 4 le 15 ms

DC 5 DC 20
IEC 408 App.C. DIN 57660 part. 107

_ 1.5 le

_ 1.5 le

_ 1 ms

DC 21

DC 22 DC 23

4 le 4 le le le 1.1 le

4 le 4 le 1.1 le

2.5 ms 15 ms 40 ms

IEC 337-1 VDE 0660 part 1/8.69

DC 11

1773

Potrebbero piacerti anche