Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
I.SCOPE : This specification covers the supply of High Voltage Construction Kit, suitable for perform quick and accurate AC dielectric tests and DC Tests of vacuum interrupters, breakers, switchgear, and other apparatus , available for tests at substation or in factory. II. STANDARD OF MANUFACTURE AND TEST : The equipment shall conform to the latest edition of the appropriate IEC specification or other recognized international standards. III. DESCRIPTION : 1. Function of equipment : High Voltage Construction Kit is a system of components for application in high voltage technology. All components have the same length and mechanical interconnections. They can be combined to form a test configuration and are extremely versatile. Test configurations are available which allow the generation of AC voltages up to 300 kV, DC voltages up to 560 kV and impulse voltages up to 560 kV. High voltage Construction Kit is used for routine and type tests on electrical equipment. 2. Technical specification of High voltage Construction Kit : Design of the high voltage kit follows major factors : A clear structure is required to ensure that the assembled circuits can be easily checked Rapid set up of the circuit in order to have as much time for active experiments as possible Lightest possible weight of individual components. This allows circuits to be built up by one person only, without danger. AC VOLTAGE : Rated voltage (kVrms) : 300 kV(3 stages x 100 kV/1 stage ) Frequency (Hz) : 50 Rated current (mA) : 10 output (kVA) : 3
/var/www/apps/conversion/tmp/scratch_3/139768578.doc 1/7
HCMC PC
DC-VOLTAGE : Rated no-load voltage (kV) : 560 kV(4 stages x 140 kV/1 stage) Rated current (mA) : 5 Output (kVA) : 5 Ripple(%) : 3 IMPULSE-VOLTAGE : Max total charging voltage (kV) : 560 kV Max energy at max charging voltage (J) : 1960 CONTROL AND MEASURING : Power Supply : 220V, 50 Hz Display : LCD display indicates measured values and the function options 360 IV. REQUIREMENT OF TECHNICAL SUBMITTED WITH THE QUOTATION : DOCUMENT
- Technical description, data sheet, catalogues and other material submitted with the quotation must enable the Purchaser to thoroughly evaluate the proposals as to its compliance with the inquiry specification. - Minimum requirements : + Detail summary of deviations to the inquiry specification. + Completed inquiry datasheet expressed at section V. + Catalogues containing outline dimension, technical data + List of main equipment and completed accessories which can perform all function described in section III have the following requirements : . Individual cost of main equipment and each accessory . Total cost of main equipment and completed accessory . Manufactures code of main equipment and each accessory + Connection diagram. + Certificate of quality management.
HCMC PC
1. Documents required to be provide for commission : In order to ensure the quality of supplied goods, in case of bid winning, the Tenderer shall supply the following documents for the Purchaser : - Manufacturers Certificate of Quality. - Certificate of Origin issued by Chamber of Commerce of the manufacturing country. - Certificate of calibration of equipment approved by an independent lawful organization. 2. Documents required to be provide in accompany with supplied products : The Supplier shall enclose the following documents for supplied products : - 01 catalog - 01 instruction manual of installation, operation and maintenance. VI. REQUIREMENT OF INSTALLATION AND INSTRUCTION FOR USE :
The Supplier shall ensure to supply the following service : - Installation the equipment completely. - Instruction to Purchasers staff how to use this equipment on site. - Trial run this equipment. VII. DATA SHEET : No Manufacturer 1. Country of origin 2. Manufacture s code 3. Standard of manufacture 4. and test Standard of quality 5. management 6. Supply of the certificate
/var/www/apps/conversion/tmp/scratch_3/139768578.doc
DESCRIPTION
REQUIREMENT
QUOTE D
3/7
HCMC PC
7.
8.
9.
10.
11.
of quality management In case of bid winning, the Tenderer shall supply the following documents for the Purchaser : - Manufacturers Certificate of Quality. - Certificate of Origin issued by Chamber of Commerce of the manufacturing country. - Certificate of calibration of equipment approved by an independent lawful organization. List of main equipment and completed accessories met all requirements of section IV is supplied in tender proposal. Quoted main equipment and completed accessories described in above list can perform all function described in section III without addition of other necessary materials. The Supplier shall ensure to supply the following service : - Installation the equipment completely. - Instruction to Purchasers staff how to use this equipment on site. - Trial run this equipment. Function of equipment High
Yes
Yes
/var/www/apps/conversion/tmp/scratch_3/139768578.doc
HCMC PC
SPECIFICATION HIGH VOLTAGE CONSTRUCTION KIT Construction Kit is a system of components for application in high voltage technology. All components have the same length and mechanical interconnections. They can be combined to form a test configuration and are extremely versatile. Test configurations are available which allow the generation of AC voltages up to 300 kV, DC voltages up to 560 kV and impulse voltages up to 560 kV. High voltage Construction Kit is used for routine and type tests on electrical equipment.
12.
Technical specification of High voltage Construction Kit : Design of the high voltage A clear structure kit follows major factors is required to ensure that the assembled circuits can be easily checked Rapid set up of the circuit in order to have as much time for active
5/7
/var/www/apps/conversion/tmp/scratch_3/139768578.doc
HCMC PC
SPECIFICATION HIGH VOLTAGE CONSTRUCTION KIT experiments as possible Lightest possible weight of individual components. This allows circuits to be built up by one person only, without danger.
AC VOLTAGE : Rated voltage (kVrms) 13. Frequency (Hz) Rated current (mA) Output (kVA) DC-VOLTAGE : Rated no-load voltage (kV) 14. Rated current (mA) Output (kVA) Ripple(%) IMPULSE-VOLTAGE : Max total charging voltage Max energy at charging voltage CONTROL AND MEASURING : Power Supply : Display :
15.
max
560 kV 1960 J
16.
17.
Instrument
220V, 50 Hz LCD display indicates measured values and the function options 360 microprocessor controlled instrument
6/7
/var/www/apps/conversion/tmp/scratch_3/139768578.doc
HCMC PC
SPECIFICATION HIGH VOLTAGE CONSTRUCTION KIT Zero start interlock External interlock Fast acting overload circuit breaker Separate Guard and return, guard circuit eliminates stray leakage currents portable for use in the field 220 V 10 %, 50Hz -20 oC to 40 oC -30 oC to 55 oC 5 to 95 R.H., noncondensing The tenderer has to quote the dimensions and weight of components of HV Kit and the total dimensions of configuration of HV Kit that can be fabricated.
20.
Others
21. 22.
Power supply Environmental : Operating temperature : Storage temperature : Relative Humidity : - Dimensions : + Width + Height + Depth - Weight
23.
/var/www/apps/conversion/tmp/scratch_3/139768578.doc
7/7