Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank DESIGN CALCULATION

API-650 Code Version: Addendum 3: Analysis Performed by: Job File: Date of Analysis:

2007 August 2011 Consultora y Diseo CoDis. C:\Documents\Gas Motor March 04, 2013

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Table of Contents

General Tank Data.................................................................................................................. 4 Tank Shell Course Materiales......................................................................................... 6 Wind Data.......................................................................................................................................9 API-650 ROOF DETAILS SPECIFICATION......................................................................... 10 API-650 SEISMIC DATA (App E.)..................................................................................... 11 Wind Information................................................................................................................... 13 MATERIAL PROPERTY INFORMATION..................................................................................... 14 SHELL COURSE ALLOWED FLUID HEIGHTS......................................................................... 15 BASE PLATE DETAILS - SHELL WEIGHT & CENTER OF GRAVITY.........................16

WIND OVERTURNING STABILITY CHECK.............................................................................. 17 WIND GIRDER INFORMATION................................................................................................... 18 WEIGHT SUMMARY......................................................................................................................... 19 Sismic Evaluatin Results Appendix E...................................................................24 Anchor Bolt Details Section 5.12........................................................................ 27 API-2000 5tk Venting Requirements.......................................................................... 29 Recommendations....................................................................................................................... 30

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

General Tank Data.


API Design Code ( 650 or 653 ) Design Method (V, O, or A) 650 O

(V=variable, O=one foot, A=Appendix A) Run Objective (D=design, A=analyze) D

Design Temperature Design Pressure at Top Shell Material

(F) 200.00 (lb./sq.in.) 0.62500 A-283

Shell Design Stress [Sd] Shell Hydro Test Stress [St]

(lb./sq.in.) 20000. (lb./sq.in.) 22500.

Tank Nominal Diameter [D] Tank Shell Height [HTK] Design Liquid Level [H] Liquid Specific Gravity [G] Weight of Attachments/Structures Distance down to Top Wind Girder Joint Efficiency (App A or 653) [E] Wind Velocity

(ft.) 27.500 (ft.) 30.000 (ft.) 30.000 0.68000 (lb.) 0.00000 (ft.) 0.00000 1.0000 (mph) 62.137

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Insulation Thickness Insulation Density (in.) 0.00000 (lb./cu.in.) 0.00000

Include Annular Base Plate Details

Yes Yes

Include Wind Moment in Appendix F_4_2 Calculations

Number of Shell Courses Shell Course # 1 Height Shell Course # 1 Thickness

5 (ft.) 6.0000 (in.) 0.25000 (in.) 0.62500E-01

Shell Course # 1 Corrosion Allowance [CA] Shell Course # 2 Height Shell Course # 2 Thickness

(ft.) 6.0000 (in.) 0.18750 (in.) 0.62500E-01

Shell Course # 2 Corrosion Allowance [CA] Shell Course # 3 Height Shell Course # 3 Thickness

(ft.) 6.0000 (in.) 0.18750 (in.) 0.62500E-01 6.0000

Shell Course # 3 Corrosion Allowance [CA] Shell Course # 4 Height Shell Course # 4 Thickness (ft.)

(in.) 0.18750 (in.) 0.62500E-01

Shell Course # 4 Corrosion Allowance [CA] Shell Course # 5 Height Shell Course # 5 Thickness

(ft.) 6.0000 (in.) 0.18750 (in.) 0.62500E-01

Shell Course # 5 Corrosion Allowance [CA]

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Tank Shell Course Materiales


Shell Course # 1 Material Name Shell Course # 1 Design Stress [Sd] Shell Course # 1 Hydro Test Stress [St] Shell Course # 1 Minimum Yield Stress Shell Course # 1 Minimum Tensile Stress Shell Course # 1 Maximum Shell Course # 1 Material Shell Course # 1 Material A-283 (lb./sq.in.) 20000. (lb./sq.in.) 22500. (lb./sq.in.) 30000. (lb./sq.in.) 55000. (in. ) 1.0000 C 1

Shell Course # 2 Material Name Shell Course # 2 Design Stress [Sd] Shell Course # 2 Hydro Test Stress [St] Shell Course # 2 Minimum Yield Stress Shell Course # 2 Minimum Tensile Stress Shell Course # 2 Maximum Shell Course # 2 Material Shell Course # 2 Material

A-283 (lb./sq.in.) 20000. (lb./sq.in.) 22500. (lb./sq.in.) 30000. (lb./sq.in.) 55000. (in. ) 1.0000 C 1

Shell Course # 3 Material Name Shell Course # 3 Design Stress [Sd] Shell Course # 3 Hydro Test Stress [St] Shell Course # 3 Minimum Yield Stress Shell Course # 3 Minimum Tensile Stress Shell Course # 3 Maximum

A-283 (lb./sq.in.) 20000. (lb./sq.in.) 22500. (lb./sq.in.) 30000. (lb./sq.in.) 55000. (in. ) 1.0000

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Shell Course # 3 Material Shell Course # 3 Material C 1

Shell Course # 4 Material Name Shell Course # 4 Design Stress [Sd] Shell Course # 4 Hydro Test Stress [St] Shell Course # 4 Minimum Yield Stress Shell Course # 4 Minimum Tensile Stress Shell Course # 4 Maximum Shell Course # 4 Material Shell Course # 4 Material

A-283 (lb./sq.in.) 20000. (lb./sq.in.) 22500. (lb./sq.in.) 30000. (lb./sq.in.) 55000. (in. ) 1.0000 C 1

Shell Course # 5 Material Name Shell Course # 5 Design Stress [Sd] Shell Course # 5 Hydro Test Stress [St] Shell Course # 5 Minimum Yield Stress Shell Course # 5 Minimum Tensile Stress Shell Course # 5 Maximum Shell Course # 5 Material Shell Course # 5 Material

A-283 (lb./sq.in.) 20000. (lb./sq.in.) 22500. (lb./sq.in.) 30000. (lb./sq.in.) 55000. (in. ) 1.0000 C 1

ANCHOR BOLT DETAILS Anchor Bolt Diameter (optional) Threads per Unit Length Bolt Allowable Stress Number of Anchor Bolts (optional) (in.) 2.7500 (1/in.) 8.0000 (lb./sq.in.) 20000. 14.000

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Bolt Yield Stress Bolt Offset from Mean Tank Diameter (lb./sq.in.) 36000. (ft.) 0.00000

Anchor Bolt Corrosion Allowance (optional) (in.) 0.00000

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Wind Data
Kz parameter Kzt parameter Kd parameter Importance Factor (I) Gust Factor (G) 1.0400 1.0000 0.95000 1.0000 0.85000

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

API-650 ROOF DETAILS SPECIFICATION


Roof Type (1-4) 1

(1=Supt Cone 2=Rafter Supt Cone 3=Cone 4=Dome 5=Umbrella) Angle Between Roof and Horizontal Net Area at Roof/Shell Junction [A] Thickness of Roof Plate Roof Plate Corrosion Allowance Weight of Snow on Roof Roof Live Load (deg) 5.3000 (sq.in.) 4.8035 (in.) 0.18750 (in.) 0.62500E-01 (lb.) 0.00000 (lb/ft2) 20.000

---/ For General Roof, No Design /--Weight of Roof Plates Weight of Roof Framing Pct of Weights Supported by Shell (lb.) 0.00000 (lb.) 0.00000 0.00000

---/ For Supported Cone Roof Design /--Preferred Rafter Type (W, WT, S, C) Preferred Girder Type (W, WT, S, C) C W

Preferred Column Type (W, WT, S, C, DC, DI, P ) P Roof Plate Material Roof Plate Allowable Design Stress Structural Member Material Structural Member Allowable Design Stress Maximum Allowed Rafter Length Maximum Allowed Girder Length Center Column Cap Plate Diameter A-36 (lb./sq.in.) 23200. A-36 (lb./sq.in.) 23200. (ft.) 20.000 (ft.) 20.000 (ft.) 3.0000

10

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

API-650 SEISMIC DATA (App E.)


Minimum Yield Strength of Bottom Plate Minimum Yield Strength of Weld Material Nominal Thickness of Bottom Plate (tb) Seismic Use Group (SUG) Friction Factor Importance Factor Initial Anchorage Type Earthquake Type Site Class (lb./sq.in.) 30000. (lb./sq.in.) 65000. (in. ) 0.25000 3.0000 0.20000 1.5000 M S 3.0000

Spectral Acceleration Adjustment Coefficient (K) 1.0000 Scaling Factor (Q) Transtiional Period (TL) 1.0000 2.4000 0.00000 1.0000 0.00000 0.00000

Mapped maximum earthquake for short periods (Ss) Mapped maximum earthquake for 1 sec periods (S1) Mapped maximum earthquake for 0 sec period Non-ASCE peak ground acceleration (Sp) (S0)

ASCE short period design acceleration parameter (SDS) 0.00000 --- Site Specific Data --Spectral acceleation parameter at 0 period (Sa0*) Spectral acceleation parameter at any period (Sa*) 1.5750 0.49900

11

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank API-2000 Venting Requirements Emptying Filling Liquid Flash Liquid Boiling Point (cu. ft./hour)5614.6 (cu.ft./hour)5614.6 (F )-40.000 (F )100.00 1.0000

Environmental Factor ........................

COMPUTATION CONTROL DIRECTIVES

ROOF_PROJECTION_IN_WIND_MOMENT= SHELL_THICK_CONVERG_TOLERANCE= GENERATE_MESSAGE_FILE= COSINE_CURVE_TOLERANCE= COSINE_CURVE_ITERATION_LIMIT= WIND_GIRDER_SHELL_THICKNESS= SHELL_SETTLEMENT_METHOD= CORRODED_NOZZLES= 653_CORRODED_HYDROTEST_CASE= THICKNESS_ROUNDUP_TO_NEAREST= PLATE_MATERIAL_DENSITY= MODIFY_FLUID_HEIGHT_BY_PRESSURE= ROUND_ANCHOR_BOLTS_BY= WIND_MOMENT_IN_APP_F FULL_SHELL_WEIGHT_IN_APP_F

YES 0.49999999E-02 in. YES 0.30000001 100.00000 MAX FOURIER_SERIES NO NO 0.00000000 in. 0.28360000 lb./cu.in. NO 4.0000000 Sect_5.9.7.1 YES

12

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Wind Information.
Wind Velocity Velocity Factor Wind Pressure Area Exposed to Wind Sect 5.9.7.1 Wind Moment on Tank Wind Shear Force Acting on Tank (mph) 62.137 0.26813 (lb./sq.in.) 0.92366E-01 (ft.**2) 842.54 (ft.lb.) 0.17169E+06 (lb.) 11206.

13

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

MATERIAL PROPERTY INFORMATION


Wind Girder Height Reduction Factor 1.0000

The following material properties have been modified in accordance with API-650 (and API-653 where applicable).

Course Number

Material Name

Design Stress (Sd)

Test Stress (St)

App M Reduction

(lb./sq.in.) (lb./sq.in.) 1 2 3 4 5 A-283 A-283 A-283 A-283 A-283 20000. 20000. 20000. 20000. 20000. 22500. 22500. 22500. 22500. 22500. 1.0000 1.0000 1.0000 1.0000 1.0000

SHELL COURSE THICKNESS DATA - One Foot Method Thickness Values for Three Cases COURSE DESIGN (in. ) TEST (in. ) MIN TEMP USER (in. ) (deg F ) Status

1 2 3 4 5

0.25000 0.18750 0.18750 0.18750 0.18750

0.25000 0.18750 0.18750 0.18750 0.18750

0.25000 0.18750 0.18750 0.18750 0.18750

11.0 11.0 11.0 11.0 11.0

NA NA NA NA NA

14

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

SHELL COURSE ALLOWED FLUID HEIGHTS


Fluid Heights for Three Cases COURSE DESIGN (ft. ) TEST (ft. ) REQUIRED (ft. )

1 2 3 4 5

78.129 52.419 52.419 52.419 52.419

79.671 60.003 60.003 60.003 60.003

32.121 26.121 20.121 14.121 8.1211

Maximum allowed fluid height of entire tank for: Design Thickness Case Test Thickness Case (ft.) 58.419 (ft.) 66.003 (ft.) 32.121

Required fluid height

15

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

BASE PLATE DETAILS - SHELL WEIGHT & GRAVITY


Annular Base Plate Thickness

CENTER OF

(in.) 0.31250

(from API-650 Table 5-1 plus corrosion) Annular Base Plate Width per 5.5.2 (in.) 28.327

( 2 + ThkCrs1 + max[ 24, (390tb / sqrt(HG))] ) Weight of Shell + Nozzles Total Weight of all Nozzles Center of Gravity (Shell+Nozzles) (lb.) 21169. (lb.) 0.00000 (ft.) 14.250

16

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

WIND OVERTURNING STABILITY CHECK


Corroded Shell Weight + %Roof Uplift Wa Mw - moment due to wind (hor+ver) press Mpi - moment due to internal pressure Mf - moment due to tank liquid Mdl - moment due to shell & roof (lb.) -4900.9 (lb./in.) 71.630 (ft.lb.) 0.12542E+06 (ft.lb.) 0.73502E+06 (ft.lb.) 0.10211E+07 (ft.lb.) 0.22662E+06

17

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

WIND GIRDER INFORMATION


For "open top" tanks ... Required Section Modulus, Top Girder Table 5-20 Detail, B value Table 5-20 Shape name (if applicable) (in.**3) 0.60831 (in.) a 0.00 3x3x.375

Maximum Height of Unstiffened Shell

(ft.) 236.22

WIND GIRDER - TRANSFORMED SECTION METHOD

Number of Intermediate Girders Reqd

18

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

WEIGHT SUMMARY
-------------Shell (Corroded) (lb.): Shell (Non-Corroded) (lb.): Annular Base Plate (lb.): Bottom Plate (lb.): Nozzles (lb.): Roof Plates (lb.): Roof Framing/Structure (lb.): Shell Attachments (lb.): Insulation (lb.): Operating Fluid (lb.): Water Weight (lb.): Operating Weight (Non-Corroded) (lb.): Test Weight (Non-Corroded (lb.): Empty Weight (Non-Corroded) (lb.): 14554. 21169. 2411. 6212. 0. 4568. 1404. 0. 0. 755166. 1110538. 790930. 1146302. 35764.

19

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank


TANK - Roof Design/Analysis Data API-650 11th Edition, Addendum 2, Nov. 2009

SUPPORTED CONE ROOF

Structural Library: AISC89.BIN ):

Roof thickness per 5.10.2.2, Cone Roof (in. 0.25000

Total weight of Roof Plates ...........(lb. 4567.6 (Based on user input thickness)

):

User Specified Design Roof Load .......(lb./sq.in.): 0.19206 (including user plate thickness)

Computed Number of Girder Rings:

Computed Number of Rafter Rings: Rafter Details from Tank Center RING Number Outer Spacing (in.) 1 16 64.795 ( 0) NUM/ GRDR Inner Spacing (in.) 0.000 ( 0) NUM/ GRDR Max

Length (ft.) 12.303

Rafter Size Details from Tank Center RING Rafter Load (lb./in.) Selected Shape --Section Modulus-Required (in.**3) 1 6.566 C3X4.1 0.77 Actual (in. **3) 1.10 20

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Column Size Details (from center, Ring 0) RING Column Load (lb.) 0 9260.5 Column Height (ft.) 31.28 Allow Comp Stress (lb./sq.in.) 10523.3 Required Radius of Gyration (in.) 2.085

RING

Num

Selected Shape

Actual Comp Stress (lb./sq.in.)

Actual Radii of Gyration (in.) 2.245 (in.) 2.245

P6_STD

1659.6

SECTION 5.10.3 CHECKS FOR ROOF MEMBERS

Rafter Ring

Actual Shear

Allowable Shear

Status

Actual

Status

Starus

Bending Bending (lb./sq.in.) (lb./sq.in.) 16261.0 20000.0 PASS

(lb./sq.in.)(lb./sq.in.) 1 400.5 13000.0 PASS

Girder Status Ring

Actual Shear

Allowable Shear

Status

Actual Bending

Allowable Bending

(lb./sq.in.) (lb./sq.in.)

(lb./sq.in.) (lb./sq.in.)

Column

Actual

Allowable

Status

21

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Ring Compression Compression

(lb./sq.in.) (lb./sq.in.) 0 1659.6 6977.2 PASS

ROOF WEIGHT SUMMARY Weight of Roof Plates (lb.): Weight of Roof Rafters (lb.): Weight of Roof Girders (lb.): Weight of Roof Columns (lb.): TOTAL Roof Weight (lb.): 4567.6 810.57 0.00000 593.92 5972.1

ROOF EVALUATIONS - Appendix F Uplift force due to internal pressure (lb.): Total weight resisting uplift (lb.): 53456. 25025.

Max Design Pressure, limited by uplift (in of H2O):

1.2444

Max Design Pressure, limited by uplift.(lb./sq.in.): 0.44936E-01 (According to F.4.2)

Max Design Pressure, Max Design Pressure, (According to F.4.1)

roof/shell joint.(in of H2O ): 18.005 roof/shell joint.(lb./sq.in.): 0.65017

(Note, this value is limited by F.4.2 for further usage.)

22

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Compression Ring Failure Pressure (in of H2O): Compression Ring Failure Pressure (lb./sq.in.): (According to F.6) 1.3911 0.50232E-01

NOTE, this tank requires an Anchored Base !!! Per F.7, allowed pressure is: (lb./sq.in.): 2.5000

Required Compression Areas, Roof/Shell Junction Area as per Section F.5 (in.**2): 4.6066

FRANGIBLE ROOF-TO-SHELL JUNCTION AREA LIMIT Area as per Section 5.10.2.6 (in.**2): 1.1570

23

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Sismic Evaluatin Results Appendix E.


Site-Specific Ground Motion

Design Fluid Weight (lb.)

0.75517E+06

Sp -design level peak accel for nonASCE Ss -MCE at period of 0.2 seconds S0 -MCE at period of 0.0 seconds S1 -MCD at period of 1.0 seconds SDS-design spectral accel parameter

0.00000 0.00000 0.00000 1.0000 0.00000

FA -acceleration based site coefficient FV -velocity based site coefficient TS - FvS1 / FaSs TC -convective sloshing period (sec)

1.2000 1.3000 0.00000 3.0316

Ac -convective spectral accel parameter Ai -impulsive spectral accel parameter Wc -effective convective fluid weight(lb. Wi -effective impulsive fluid weight (lb. Vc -convective liquid base shear Vi -impulsive liquid base shear V -total design base shear (lb. (lb. (lb. (lb. ) ) ) ) ) )

0.37425 1.4766 0.14864E+06 0.61422E+06 55630. 0.95887E+06 0.96048E+06 0.15807E+06

VS -shear resistance

24

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Xc -ring wall convective moment arm Xi -ring wall impulsive moment arm XCS-slab convective moment arm XIS-slab impulsive moment arm WS -shell+appurtenances weight Wrs-roof, framing 10% snow weight Mrw-ringwall overturning moment Ms -slab overturning moment

(ft. (ft. (ft. (ft. (lb. (lb.

) ) ) ) ) ) ) )

24.831 13.476 25.024 17.711 21169. 2689.1 0.12982E+08 0.16807E+08

(ft.lb. (ft.lb.

AV -vertical acceleration parameter Ge -effective specific gravity

0.00000 0.68000

wa -resisting annulus force

(lb./in.)

64.071 23.013 16.427

wt -tank + roof weight at shell base (lb./in.) J L -the anchorage ratio -reqd min annular plate projection (ft. )

0.00000

Anchorage ratio too large, anchors needed

Wab-Minimum anchorage resistance (lb./in.) N -number of anchor bolts required )

1849.6 12 0.15980E+06 7376.4 6440.5

Pab-anchor seismic design load (lb.

Sc -shell compressive stress (lb./sq.in.) Sa -shell allowable stress (lb./sq.in.)

25

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Height of sloshing wave (ft. Required Freeboard (ft. ) ) 0.00000 0.00000

Course

Hoop Stress (lb./sq.in.) 1 2 3 4 5 10467. 12401. 10822. 8714.0 5668.8

Hoop Allowable (lb./sq.in.) 26600. 26600. 26600. 26600. 26600.

Seismic Evaluation Summary. Seismic shell stress check failed. Base shear exceeds the limit. Hoop stress within allowable.

26

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Anchor Bolt Details Section 5.12.

Case

Uplift (lb.)

Allowable Bolt Stress (lb./sq.in.)

Load/Bolt (lb.)

Design Pressure: Test Pressure: Failure Pressure: Wind Loading: Seismic OPE: Design Press+Wind Load: Design Press+Seismic OPE: Frangibility Pressure:

0.00000 33817. 0.00000 0.00000 0.187E+07 0.00000 0.187E+07 0.00000

15000. 20000. 36000. 28800. 28800. 20000. 28800. 36000.

0.00000 2415.5 0.00000 0.00000 1.13370E+06 0.00000 0.13381E+06 0.00000

ANCHOR BOLT RESULTS - Section 5.12

Case

Number of Bolts (in.

Bolt Diameter ) 2.750 2.750 2.750 2.750 2.750

Bolt Stress (lb./sq.in.)

Design Pressure: Test Pressure: Failure Pressure: Wind Loading: Seismic OPE:

14 14 14 14 14

0. 459. 0. 0. 25424.

27

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank Design Press+Wind Load: Design Press+Seismic OPE: Frangibility Pressure: 14 14 14 2.750 2.750 2.750 0. 25444. 0.

Final Anchor Bolt Spacing (ft. ) Specified number of user bolts is sufficient. Specified user bolt diameter is sufficient.

6.17

28

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

API-2000 5tk Venting Requirements.


IN-BREATHING: For Thermal Effects, Required Air Volume (cu ft./hr): For Liquid Movement (emptying rate) (cu ft./hr): 3398.0 5600.0

OUT-BREATHING: For Thermal Effects, Required Air Volume (cu ft./hr): For Liquid Movement (filling rate) (cu ft./hr): 3398.0 12000.0

EMERGENCY VENTING DUE TO FIRE Sect 4.3.3.2.2 Eq.2A, Required Air Volume (cu ft./hr):697112.3 Wetted Area (sq ft.): Tank Capacity (cu ft. ): 2591.8 19078.6

29

Filename: Calculo Gas Motor Tank 3000 Analysis: API-650 Tank

Recommendations

Not find the design temperature. The design pressure set by experience. Please check. The specific gravity of the gasoline engine was taken as 0.68. Please check. In the information provided was not found speed Wind. It takes 100 km / h according NSR-10 The results of the diameter of the anchors depend on the internal pressure, earthquake, wind and slenderness. The equipment is manufactured according chose reference information. The calculation will include links back to the development of the general plan of the tank.