Serial Base devices: IOE-4404 IOE-4422 IOE-4440 Expansion Module devices: IOEX-4404 IOEX-4422 IOEX-4440
I/O Expansion
Safety Information
The products described in this manual can fail in a variety of modes due to misuse, age, or malfunction. Systems with these products must be designed to prevent personal injury and property damage during product operation and in the event of product failure.
Warranty
FreeWave Technologies warrants your FreeWave Wireless Data Transceiver against defects in materials and manufacturing for a period of two years from the date of shipment. In the event of a Product failure due to materials or workmanship, FreeWave will, at its option, repair or replace the Product. The Product must be returned to FreeWave upon receiving a Return Material Authorization (RMA) for evaluation of Warranty Coverage. In no event will FreeWave Technologies Inc., its suppliers, and its licensors be liable for any damages arising from the use of or inability to use this Product. This includes business interruption, loss of business information, or other loss which may arise from the use of this Product. Please be advised that OEM customers warranty periods may vary. Warranty Policy may not apply: 1. If Product repair, adjustments or parts replacements is required due to accident, neglect, unusual
Restricted Rights
Any product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Information in this manual is subject to change without notice and is proprietary and confidential to FreeWave Technologies, Inc. This manual is for use by purchasers and other authorized users of the FreeWave Wireless Data Transceiver only. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, or for any purpose without the express written permission of FreeWave Technologies, Inc. FreeWaves Spread Spectrum Wireless Data Transceivers are designed and manufactured in the United States of America. This product is licensed by The United States. Diversion contrary to U.S. law is prohibited. Shipment or reexport of this product outside of The United States may require authorization by the U.S. Bureau of Export Administration. Please contact FreeWave Technologies for assistance and further information.
Printed in the United States of America. Copyright 2011 by FreeWave Technologies, Inc. All rights reserved
FreeWave Technologies, Inc. 1880 South Flatiron Court Boulder, CO 80301 Phone: 303-444-3862 Fax: 303-786-9948 www.FreeWave.com
LUM0017AA Rev I
ii
This product is licensed by The United States. Diversion contrary to U.S. law is prohibited. Shipment or reexport of this product outside of The United States may require authorization by the U.S. Bureau of Export Administration. Please contact FreeWave Technologies for assistance and further information.
UL Notification
Models IOEX-4404, IOEX-4422, and IOEX-4400 are suitable for use in Class1, Division 2, Groups A, B, C, and D or nonhazardous locations only. The connectors shall not be connected or disconnected while circuit is live unless area is known to be non-hazardous.
Warning! EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2. Input power and all I/O power, except relay output contacts, shall be derived from a single Class 2 power source. Subject Devices are to be installed in the vertical orientation only. Devices were tested for vertical orientation only and not the horizontal orientation.
LUM0017AA Rev I
iii
I/O Expansion
FCC Notifications
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may cause undesired operation.
This device must be operated as supplied by FreeWave Technologies, Inc. Any changes or modifications made to the device without the express written approval of FreeWave Technologies may void the user's authority to operate the device.
LUM0017AA Rev I
iv
Table of Contents
1 2 2.1 Table of Contents .............................................................................................................. v Model Overview ................................................................................................................. 1 Base Module ........................................................................................................................ 1 2.1.1 Radio Base ............................................................................................................. 1 2.1.2 Serial Base ............................................................................................................. 1 Expansion Module ............................................................................................................... 1 Data Interfaces ................................................................................................................... 2 Serial Base .......................................................................................................................... 2 3.1.1 Data Connector ...................................................................................................... 2 3.1.2 485/Power Connector ............................................................................................. 2 3.1.3 Diagnostic Connector ............................................................................................. 2 Expansion Module ............................................................................................................... 2 3.2.1 Data Connector ...................................................................................................... 2 3.2.2 Diagnostic Connector ............................................................................................. 2 Power .................................................................................................................................. 3 4.1.1 Data Connector ...................................................................................................... 3 4.1.2 485/Power Connector ............................................................................................. 4 I/O Interface ........................................................................................................................ 5 I/O Summary........................................................................................................................ 5 I/O Description ..................................................................................................................... 6 5.2.1 Universal Channels ................................................................................................ 6 5.2.1.1 Digital Input ............................................................................................ 6 5.2.1.2 Digital Output.......................................................................................... 7 5.2.1.3 Analog Input ........................................................................................... 8 5.2.1.4 Analog Output ........................................................................................ 9 5.2.1.5 Sensor Power ....................................................................................... 10 5.2.2 Input-Only Channels ............................................................................ 11 5.2.2.1 Digital Input .......................................................................................... 11 5.2.2.2 Analog Input ......................................................................................... 12 5.2.3 Isolated Channels ................................................................................................. 14 5.2.3.1 Isolated Digital Input ........................................................................... 14 5.2.3.2 Isolated Digital Output ........................................................................ 15 Modbus Interface ............................................................................................................. 16 Quick Reference Modbus Register Map ........................................................................... 16 Complete Modbus Register Map ....................................................................................... 17 6.2.1 Holding Coils (Read/Write) ................................................................................... 17 6.2.2 Input Coils (Read-Only) ........................................................................................ 19 6.2.3 Input Registers (Read-Only) ................................................................................. 20 6.2.4 Holding Registers (Read/Write) ............................................................................ 21 Modbus Register Descriptions........................................................................................... 23 6.3.1 Holding Coils (Read/Write) ................................................................................... 23 6.3.2 Input Coils (Read-Only) ........................................................................................ 25 6.3.3 Input Registers (Read-Only) ................................................................................. 25 6.3.4 Holding Registers (Read/Write) ............................................................................ 26 Modbus Timing .................................................................................................................. 32 Mechanical Information .................................................................................................. 33 Serial Base Dimensions .................................................................................................... 33 Expansion Module Dimensions ......................................................................................... 34
2.2 3 3.1
3.2
5 5.1 5.2
6 6.1 6.2
6.3
LUM0017AA Rev I
Model Overview
I/O Expansion products provide modular remote measurement and control capabilities to any device with wired or wireless communication. Expandable I/O can be added directly to PLCs, RTUs, and SCADA hosts. I/O Expansion can also integrate into new and existing wireless communication systems such as licensed and unlicensed, cellular and satellite radio systems.
This document does not provide reference information for Radio Base devices.
LUM0017AA Rev I
I/O Expansion
Data Interfaces
Used to place the Base into Setup Mode Data Terminal Ready Transmit Data Receive Data Carrier Detect Request to Send Clear to Send
Power
Power is shared between all devices in a stack of Expansion Modules. When one device in the stack is powered (Expansion Module, Serial Base, or Radio Base) then all connected devices are powered as well. A stack of Expansion Modules can be powered in one of three ways. Power can be provided through: Data Connector on the top Expansion Module 485/Power Connector on a Serial Base I/O Connector on a Radio Base (consult the user manual for the FGR2-IO-IOE for details) Power supply voltage limits for all Serial Base and Expansion Modules are as follows: Item Power supply voltage Symbol VBAT Min 7.5 Typical Max 30 Units V
Typical current consumption for Serial Base and Expansion Modules is as follows: Channel Configuration Universal Input-Only Channels Channels Disabled Disabled DO: Off Disabled DO: On Disabled DI DI AO: 0 mA Disabled AO: 20 mA Disabled AI: Voltage AI: Voltage AI: Current AI: Current Current Consumption 12 V 24 V 17.0 17.0 18.1 17.0 18.2 98.2 17.0 25
Isolated Channels Disabled DO: Off DO: On DI Disabled Disabled Disabled Disabled
Units mA mA mA mA mA mA mA mA
LUM0017AA Rev I
I/O Expansion
Power Ground
LUM0017AA Rev I
I/O Interface
All I/O Expansion devices have 12 I/O channels. All models feature four universally configurable channels, four input-only channels, and four electrically isolated channels. I/O Expansion provides flexibility to process automation by providing additional I/O points. The different models have the following I/O configuration: IOE-4440 and IOEX-4440, have all four isolated channels populated as digital inputs. IOE-4422 and IOEX-4422, have two isolated channels populated as digital inputs and two isolated channels populated as digital outputs. IOE-4404 and IOEX-4404, have all four isolated channels populated as digital outputs.
Table 6.1.1 I/O Summary for IOE-4440 and IOEX-4440 Universal Channels Input-Only Channels 4440 Channels Number 1 2 3 4 5 6 7 8 Digital Input 12 Digital Output 4 Analog Input 8 Analog Output 4 Sensor Power 4 Table 6.1.2 I/O Summary for IOE-4422 and IOEX-4422 Universal Channels Input-Only Channels 4422 Channels Number 1 2 3 4 5 6 7 8 Digital Input 10 Digital Output 6 Analog Input 8 Analog Output 4 Sensor Power 4 Table 6.1.3 I/O Summary for IOE-4404 and IOEX-4404 Universal Channels Input-Only Channels 4404 Channels Number 1 2 3 4 5 6 7 8 Digital Input 8 Digital Output 8 Analog Input 8 Analog Output 4 Sensor Power 4
Isolated Channels 9 10 11
12
Isolated Channels 9 10 11
12
Isolated Channels 9 10 11
12
LUM0017AA Rev I
I/O Expansion
Figure 5.2.1.1 Serial Base and Expansion Module with Universal Channels Highlighted 5.1.1.1 Digital Input A universal channel configured as a Digital Input supports the features below. Pull-Up and Pull-Down Resistors: User selectable pull-up and pull-down resistors. Pull-up resistor is pulled to 3.5 V internally through an overload protection diode. Pull-down resistor is pulled to GND through an overload protection diode. For more information, see 40056 to 40063: Resistor Pull Setting in the register map section of this document. Pulse Counting: Pulse counting for input signals up to 100 Hz. De-bounced pulse counting for input signals to 10 Hz. Selectable rising-edge or falling-edge counting. Counter increment latch triggers on the event of a counter-incrementing pulse edge. This latch allows you to scan for the input change at a much slower speed than the duration of the pulse. Critical counting ensures that each pulse is reported by only clearing pulses that you have read. For more information, see 152 to 163: Pulse Counter Debounce, 30064 to 30086: DI Counter, and 96 to 107: DI Counter Falling Edge Increment in the register map section of this document. Characteristics of universal channels configured as Digital Inputs: Item Symbol Min Input Low (OFF) voltage VIL 0 Input High (ON) voltage VIH 3.0 Pulse counting frequency FPC De-Bounced pulse counting frequency FPCDB Pulse width TPC 4 De-bounced pulse width TPCDB 40 Pull-up resistance RPU Pull-up voltage (measured externally) VPU Pull-down resistance to ground RPD -
Typical 1 3.0 10
Units V V Hz Hz ms ms k V k
LUM0017AA Rev I
5.1.1.2
Digital Output A universal channel configured as a Digital Output supports the features below. Solid-State Switch to Ground: Solid-state digital outputs with reverse-blocking Schottky diodes are rated at 1 A across the complete operating temperature range. Output voltage range is up to 30 V. Each channel has a ground pin for current return and must be used for large currents (over 0.1 A). Reports approximate amount of current flowing to ground. Configurable for normally open or normally closed. For more information, see 30112 to 30119: DO Current in the register map section of this document. Bi-Stable or Mono-Stable: Bi-stable output maintains the last state until a different command is received. Mono-stable output holds the state for a user-configurable time before automatically reverting to its original state. For more information, see 40080 to 40091: DO Monostable Timeout in the register map section of this document. Default Settings: Output ON or output OFF are available as default outputs for fail-safe operation. Default setting is applied when the device is powered up or when the communication timeout (configurable) elapses. For more information, see 24 to 35: Apply Default DO, AO, Sensor Power in the register map section of this document. Pull-Up and Pull-Down Resistors: User selectable pull-up and pull-down resistors. Pull-up resistor is pulled to 3.5 V internally through an overload protection diode. Pull-down resistor is pulled to GND internally through an overload protection diode. For more information, see 40056 to 40063: Resistor Pull Setting in the register map section of this document. Circuitry Protection: Self-resetting circuitry disables specific functions when maximum conditions are exceeded, eliminating the need for external fuses. User notification is achieved by the Circuitry Protection coil. For more information, see 10024 to 10035: Circuitry Protection Active in the register map section of this document Characteristics of universal channels configured as Digital Outputs: Item Symbol Min Output ON sinking current IOH * Output ON resistance to ground ROH 0 Output ON circuitry protection limit ICP Output OFF resistance to ground ROL 234 External load voltage connection VOFF 0
Units A A k V
LUM0017AA Rev I
I/O Expansion
Item Symbol Min Pull-up resistance RPU Pull-up voltage (measured externally) VPU * Pull-down resistance to ground RPD * Dynamic resistance; a reverse-blocking Schottky diode is in series.
Typical 1 3.0 10
Max -
Units k V k
5.1.1.3
Analog Input A universal channel configured as an Analog Input supports the features below. Voltage and Current: 20-bit analog to digital converter yields 0.10% reading accuracy across entire operating temperature for voltage and current input signals. Voltage range supports 1 to 5 V and 0 to 10 V analog signals. Complete voltage range is -2.5 to 12.5 V. Current range supports 4 to 20 mA analog signals. Complete current range is 0 to 25 mA. The low end of the analog input can be calibrated to zero by adjusting Voltage Zero and Current Zero registers. The high end of the analog input can be calibrated to full scale by adjusting Voltage Span and Current Span registers. For more information, see the following register descriptions in the register map section of this document: o 120 to 127: AI Current Mode o 40096 to 40103: AI Zero Voltage o 40112 to 40119: AI, AO Zero Current o 40104 to 40111: AI Voltage Span o 40120 to 40127: AI, AO Current Span Unsigned, Signed, and Floating Point: Analog input results can be reported in unsigned or signed integer formats. Analog input results are always accessible with floating point, decimal numbers in Volts and MilliAmps. Unsigned and signed integers can be used for 16-bit or 20-bit readings by selecting left alignment (for 16-bit) or right alignment (for 20-bit). Selectable word order allows interoperability with any RTU, PLC, or SCADA host. For more information, see 112 to 119: AI Signed Integer Result, 30000 to 300014: AI Integer Result, and 30032 to 30046: AI Floating Point Result in the register map section of this document. Selective Filtering/Averaging: Signal noise can be overcome by enabling time-averaging filters. Filtering/averaging can be adjusted for different time periods or completely disabled. For more information, see 40040 to 40047: AI Filter Setting in the register map section of this document. Circuitry Protection: Self-resetting circuitry disables specific functions when maximum conditions are exceeded, eliminating the need for external fuses. User notification is achieved by the Circuitry Protection coil. For more information, see 10024 to 10035: Circuitry Protection Active in the register map section of this document
LUM0017AA Rev I
Characteristics of universal channels configured as Analog Inputs: Item Symbol Min Typical Voltage Input Analog input voltage VIN -2.5 Full-scale input voltage Resolution * Scaling factor (all 20 bits) * Scaling factor (upper 16 bits) Accuracy Error (0 to 5 V input) Current Input Analog input current Circuitry protection limit Internal sense resistor * Full-scale input current range Resolution * Scaling factor (all 20 bits) * Scaling factor (upper 16 bits) Accuracy Error (4 to 20 mA input)
*
25 251 Greater of 4 A or 0.10 % of input * These settings apply only when zero and range registers are set to 0 (default).
0 249 0
5.1.1.4
Analog Output A universal channel configured as an Analog Output supports the features below. Current Output: Current range supports 4 to 20 mA analog signals. Complete current range is 0 to 25 mA. Output current can be written in microAmps or as a scaled integer. When writing output current with a scaled integer 12-bit, 14-bit, 15-bit, and 16-bit integers are supported. The zero of the analog output can be calibrated on the low end by adjusting the Current Zero register. The full scale of the analog output can be calibrated to the high end by adjusting the Current Span register. For more information, see the register descriptions for the following in the register map section of this document: o 40072 to 40073: AO Resolution o 40112 to 40119: AI, AO Zero Current o 40120 to 40127: AI, AO Current Span Default Settings: Configurable default output levels are available as default outputs for fail-safe operation. Default setting is applied when the device is powered up or when the communication timeout (configurable) elapses. For more information, see 24 to 35: Apply Default DO, AO, Sensor Power in the register map section of this document. Pull-Up and Pull-Down Resistors: User selectable pull-up and pull-down resistors.
LUM0017AA Rev I
I/O Expansion
Pull-up resistor is pulled to 3.5 V internally through an overload protection diode. Pull-down resistor is pulled to GND internally through an overload protection diode. For more information, see 40056 to 40063: Resistor Pull Setting in the register map section of this document.
Characteristics of universal channels configured as Analog Outputs: Item Symbol Min Typical Analog output current IOUT 0 * Full-scale output current IFS 25 Resolution Res 15 * Scaling factor FSV20 1 Voltage on output pin VOUT,I Accuracy Error (at 20 mA output) VMEAS -0.25 * These settings apply only when zero and range registers are set to 0 (default).
5.1.1.5
Sensor Power A universal channel configured as Sensor Power supports the features below. Transmitter Power: Power for sensors and transmitters up to 50 mA is provided. Voltage provided to the transmitter is roughly equal to the power provided to the Serial Base or Expansion Module, minus approximately 0.5 V, minus load current, multiplied by 10 ohms. Circuitry Protection: Self-resetting circuitry prevents damage to the device when maximum conditions are exceeded, eliminating the need for external fuses. User notification is achieved by the Circuitry Protection coil. For more information, see 10024 to 10035: Circuitry Protection Active in the register map section of this document. Characteristics of universal channels configured as Sensor Power: Item Symbol Min Voltage output VOUT VBAT 1 Current output IOUT 0 Circuitry protection limit IOUT -
Max VBAT 50 -
Units V mA mA
LUM0017AA Rev I
10
Figure 5.2.2.1 Serial Base and Expansion Module with Input-Only Channels Highlighted
5.1.2.1
Digital Input An input-only channel configured as a Digital Input supports the features below. Pull-Up and Pull-Down Resistors: User selectable pull-up and pull-down resistors. Pull-up resistor is pulled to 3.5 V internally through an overload protection diode. Pull-down resistor is pulled to GND internally through an overload protection diode. For more information, see 40056 to 40063: Resistor Pull Setting in the register map section of this document. High-Speed Pulse Counting: Pulse counting for input signals up to 10 kHz. User must assign high-speed counting to only one channel of 5 or 9, 6 or 10, 7 or 11, and 8 or 12. Selectable rising-edge or falling-edge counting. Counter increment latch triggers on the event of a counter-incrementing pulse edge. This latch allows users to scan for the input change at a much slower speed than that of the pulse. Critical counting ensures that every single pulse is reported to the user by only clearing pulses that have been read by the user. High-speed counting is not de-bounced and inputs must not go below GND. For more information, see 92 to 95: High-Speed DI Counter on Isolated in the register map section of this document. Important: For accurate counting at high speed, the voltage at the Digital Input pin must not drop below 0 V. Proper grounding techniques and short wiring connections are necessary to ensure accurate counting for high speed signals. If the voltage at the Digital Input pin drops below 0 V, there may be false edges detected and the Digital Input pulse count can be higher than expected.
LUM0017AA Rev I
11
I/O Expansion
Characteristics of input-only channels configured as Digital Inputs: Item Symbol Min Input Low (OFF) voltage VIL 0 Input High (ON) voltage VIH 3.0 Pulse counting frequency, standard speed FPC Pulse counting frequency, high-speed FPC Pulse width, standard speed TPC 4 Pulse width, high-speed TPC 40 Pull-up resistance RPU Pull-up voltage (measured externally) VPU Pull-down resistance to ground RPD -
Typical 1 3.0 10
Units V V Hz kHz ms s k V k
5.1.2.2
Analog Input An input-only channel configured as an Analog Input supports the features below. Voltage and Current: 20-bit analog to digital converter yields 0.10% reading accuracy across entire operating temperature for voltage and current input signals. Voltage range supports 1 to 5 V and 0 to 10 V analog signals. Complete voltage range is -2.5 to 12.5 V. Current range supports 4 to 20 mA analog signals. Complete current range is 0 to 25 mA. The low end of the analog input can be calibrated to zero by adjusting Voltage Zero and Current Zero registers. The high end of the analog input can be calibrated to full scale by adjusting Voltage Span and Current Span registers. For more information, see the following register descriptions in the register map section of this document: o 120 to 127: AI Current Mode o 40096 to 40103: AI Zero Voltage o 40112 to 40119: AI, AO Zero Current o 40104 to 40111: AI Voltage Span o 40120 to 40127: AI, AO Current Span Unsigned, Signed, and Floating Point: Analog input results can be reported in unsigned or signed integer formats. Analog input results are always accessible with floating point, decimal numbers in Volts and MilliAmps. Unsigned and signed integers can be used for 16-bit or 20-bit readings by selecting left alignment (for 16-bit) or right alignment (for 20-bit). Selectable word order allows interoperability with any RTU, PLC, or SCADA host. For more information, see 112 to 119: AI Signed Integer Result, 30000 to 300014: AI Integer Result, and 30032 to 30046: AI Floating Point Result in the register map section of this document. Selective Filtering/Averaging: Signal noise can be overcome by enabling time-averaging filters. Filtering/averaging can be adjusted for different time periods or completely disabled. For more information, see 40040 to 40047: AI Filter Setting in the register map section of this document.
LUM0017AA Rev I
12
Circuitry Protection: Self-resetting circuitry disables specific functions when maximum conditions are exceeded, eliminating the need for external fuses. User notification is achieved by the Circuitry Protection coil. For more information, see 10024 to 10035: Circuitry Protection Active in the register map section of this document Characteristics of input-only channels configured as Analog Inputs: Item Symbol Min Typical Voltage Input Analog input voltage VIN -2.5 * Full-scale input voltage VFS 13.75 Resolution Res 20 * Scaling factor (all 20 bits) FSV20 9.54 * Scaling factor (upper 16 bits) FSV16 153 Accuracy Error (0 to 5 V input) VMEAS 0 Current Input Analog input current Circuitry protection limit Internal sense resistor * Full-scale input current range Resolution * Scaling factor (all 20 bits) * Scaling factor (upper 16 bits) Accuracy Error (4 to 20 mA input)
25 251 Greater of 4 A or 0.10 % of input * These settings apply only when zero and range registers are set to 0 (default).
0 249 0
LUM0017AA Rev I
13
I/O Expansion
Figure 5.2.3.1 Serial Base and Expansion Module with Isolated Channels Highlighted
5.1.3.1
Isolated Digital Input An isolated channel built as isolated a Digital Input supports the features below. Optical Digital Inputs: Optically isolated circuit accepts 30 VDC input signals regardless of device supply voltage. High-Speed Pulse Counting: Pulse counting for input signals up to 10 kHz. You must assign high-speed counting to only one channel of 5 or 9, 6 or 10, 7 or 11, and 8 or 12. Selectable rising-edge or falling-edge counting. Counter increment latch triggers on the event of a counter-incrementing pulse edge. This latch allows you to scan for the input change at a much slower speed than that of the pulse. Critical counting ensures that every single pulse is reported by only clearing pulses that you have read. For more information, see 92 to 95: High-Speed DI Counter on Isolated in the register map section of this document. Characteristics of isolated channels built as Digital Inputs: Item Symbol Input Low (OFF) voltage VIL Input High (ON) voltage VIH Pulse counting frequency, standard speed FPC Pulse counting frequency, high-speed FPC Pulse counting frequency, de-bounced FPCDB Pulse width, standard speed TPC Pulse width, high-speed TPC Pulse width, de-bounced TPCDB
Min 0 3.2 4 40 40
Typical -
Units V V Hz kHz Hz ms s ms
LUM0017AA Rev I
14
5.1.3.2
Isolated Digital Output An isolated channel built as isolated Digital Output supports the features below. Digital Output Relays: Mechanical relays capable of switching up to 2 A at 250 VDC or VAC. Long life relays with 80,000 cycles. Normally open. Bi-Stable or Mono-Stable: Bi-stable output maintains the last state until a different command is received. Mono-stable output holds the non-default state for a user-configurable time before automatically reverting to its default state. For more information, see 40080 to 40090: DO Monostable Timeout in the register map section of this document. Default Settings: Output ON or output OFF are available as default outputs for fail-safe operation. Default setting is applied when the device is powered up or when the communication timeout (configurable) elapses. For more information, see 24 to 35: Apply Default DO, AO, Sensor Power in the register map section of this document. Characteristics of isolated channels built as Digital Outputs: Item Symbol Output ON current across terminals IOH Output ON resistance across terminals ROH Output OFF resistance across terminals ROL External AC or DC voltage connection VDC/AC
Min 0 10 0
Typical -
Units A M V
LUM0017AA Rev I
15
I/O Expansion
Modbus Interface
Note the following when using the Modbus register maps below: Add 200 to the register addresses for each device in the stack to access stacked Expansion Modules. Add 1 to registers in protocol addressing (base 0) to obtain PLC addressing (base 1).
LUM0017AA Rev I
16
Bits 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 17
I/O Expansion
Address Protocol 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 136 137 138 139 140 141 142 143 144 145 146 147 152 153 154 155 156 157 158
PLC 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 113 114 115 116 117 118 119 120 122 123 124 125 126 127 128 129 137 138 139 140 141 142 143 144 145 146 147 148 153 154 155 156 157 158 159
I/O Channel 5, 9 6, 10 7, 11 8, 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7
Entity HIGH-SPEED DI COUNTER ON ISOLATED HIGH-SPEED DI COUNTER ON ISOLATED HIGH-SPEED DI COUNTER ON ISOLATED HIGH-SPEED DI COUNTER ON ISOLATED DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT DI COUNTER FALLING EDGE INCREMENT AI SIGNED INTEGER RESULT AI SIGNED INTEGER RESULT AI SIGNED INTEGER RESULT AI SIGNED INTEGER RESULT AI SIGNED INTEGER RESULT AI SIGNED INTEGER RESULT AI SIGNED INTEGER RESULT AI SIGNED INTEGER RESULT AI CURRENT MODE AI CURRENT MODE AI CURRENT MODE AI CURRENT MODE AI CURRENT MODE AI CURRENT MODE AI CURRENT MODE AI CURRENT MODE DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH DI COUNTER LATCH PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE
Bits 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
LUM0017AA Rev I
18
I/O Channel 8 9 10 11 12
Entity PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE PULSE COUNTER DEBOUNCE
Bits 1 1 1 1 1
Bits 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
LUM0017AA Rev I
19
I/O Expansion
Bits 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 16 16 16 16 16 16 16 16 16 16 16
LUM0017AA Rev I
20
Bits 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 21
I/O Expansion
Address Protocol 40083 40088 40089 40090 40091 40096 40097 40098 40099 40100 40101 40102 40103 40104 40105 40106 40107 40108 40109 40110 40111 40112 40113 40114 40115 40116 40117 40118 40119 40120 40121 40122 40123 40124 40125 40126 40127 40128 40129 40130 40131 40132 40133 40134 4013
PLC 40088 40089 40090 40091 40092 40097 40098 40099 40100 40101 40102 40103 40104 40105 40106 40107 40108 40109 40110 40111 40112 40113 40114 40115 40116 40117 40118 40119 40120 40121 40122 40123 40124 40125 40126 40127 40128 40129 40130 40131 40132 40133 40134 40135 40136
I/O Channel 4 9 10 11 12 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 -
Entity DO MONOSTABLE TIMEOUT DO MONOSTABLE TIMEOUT DO MONOSTABLE TIMEOUT DO MONOSTABLE TIMEOUT DO MONOSTABLE TIMEOUT AI ZERO VOLTAGE AI ZERO VOLTAGE AI ZERO VOLTAGE AI ZERO VOLTAGE AI ZERO VOLTAGE AI ZERO VOLTAGE AI ZERO VOLTAGE AI ZERO VOLTAGE AI VOLTAGE SPAN AI VOLTAGE SPAN AI VOLTAGE SPAN AI VOLTAGE SPAN AI VOLTAGE SPAN AI VOLTAGE SPAN AI VOLTAGE SPAN AI VOLTAGE SPAN AI, AO ZERO CURRENT AI, AO ZERO CURRENT AI, AO ZERO CURRENT AI, AO ZERO CURRENT AI, AO ZERO CURRENT AI, AO ZERO CURRENT AI, AO ZERO CURRENT AI, AO ZERO CURRENT AI, AO CURRENT SPAN AI, AO CURRENT SPAN AI, AO CURRENT SPAN AI, AO CURRENT SPAN AI, AO CURRENT SPAN AI, AO CURRENT SPAN AI, AO CURRENT SPAN AI, AO CURRENT SPAN COMM CONNECTION COMM TIMEOUT LATCH COMM PORT BAUD RATE COMM PORT PARITY COM PORT STOP BITS MODBUS MIN TRANSMIT INTERMSG INTERVAL RS485 TURN ON DELAY RS485 TURN OFF DELAY
Bits 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
LUM0017AA Rev I
22
24 to 35: Apply Default DO, AO, Sensor Power This register is used upon device power up and upon communication timeout. If this register is set to ON (1), upon power up, channels configured as Digital Output, Analog Output, and Sensor Power output their default values. If this register is set to OFF (0), then factory default values are applied upon power up. Every device has a timer that is reset when it receives a Modbus command or query. If the device does not receive a Modbus command or query for the time set in Default Delay, then a communication timeout occurs. If a communication timeout occurs and this register is set to ON (1), the channels configured as Digital Output, Analog Output, or Sensor Power changes outputs to the default settings. If this register is set to OFF (0), then the channel outputs do not change.
48 to 59: Default DO, Sensor Power State This is the default state for channels configured as Digital Output and Sensor Power. For this setting to apply, the Apply Default DO, AO, Sensor Power register must be turned ON (1) for the specific channel.
72 to 83: DI Counter Clear This register clears the Digital Input counters in one of two ways: Writing 1 to this register forces the DI counter to 0. This method forces the count to 0 even if pulses have arrived since the last DI counter read. Writing 0 clears the register in a way called critical counting. Critical counting is a function that keeps track of all the pulses that have been reported. By clearing this register with critical counting, then the DI counter is set to the number of pulses that have arrived since the last DI counter read. In this way, you can keep track of each pulse that arrives. 23
LUM0017AA Rev I
I/O Expansion
92 to 95: HighSpeed DI Counter on Isolated There are four high-speed DI counters available that support counting up to 10 kHz. Use this register to select which channel to use as high-speed counters. If a channel is not assigned to high-speed counting it supports standard speed counting. Standard-speed counters support 100 Hz pulses, or 10 Hz pulses with de-bounce. Setting coil 92 to ON (1) sets channel 9 to high-speed and channel 5 to standard speed. Setting to OFF (0) sets channel 9 to standard-speed and channel 5 to high-speed. Setting coil 93 to ON (1) sets channel 10 to high-speed and channel 6 to standard speed. Setting to OFF (0) sets channel 10 to standard-speed and channel 6 to high-speed. Setting coil 94 to ON (1) sets channel 11 to high-speed and channel 7 to standard speed. Setting to OFF (0) sets channel 11 to standard-speed and channel 7 to high-speed. Setting coil 95 to ON (1) sets channel 12 to high-speed and channel 8 to standard speed. Setting to OFF (0) sets channel 12 to standard-speed and channel 8 to high-speed.
96 to 106: DI Counter Falling Edge Increment When this coil is ON (1), the counter for a Digital Input is incremented when the input goes from 1 to 0 (a falling edge). When this coil is OFF (0), the counter for a Digital Input is incremented when the input goes from 0 to 1 (on a rising edge).
112 to 119: AI Signed Integer Result When a channel is configured as Analog Input and this coil is ON (1), the AI Result, Integer is a signed number. A signed integer is necessary to report negative input voltages or if the RTU/PLC supports signed results only. When this register is set to OFF (0), the AI Result, Integer is an unsigned number. The default is OFF (0).
120 to 127: AI Current Mode When set to ON (1), an internal 250 sense resistor is turned on to report 4 to 20 mA inputs. The complete current range is from 0 to 25 mA. Setting this coil to OFF (0) disables the sense resistor and supports reading voltage input. This is needed for 1 to 5 V and 0 to 10 V transmitters. The complete voltage range is from -2.5 to 12.5 V.
136 to 147: DI Counter Latch This register is set to ON internally when the DI Counter is incremented. This is useful for systems that poll the Digital Input states at slower speeds than the duration of Digital Input signals. Write 0 to this register to clear the latch.
152 to 163: Pulse Counter De-bounce If set to OFF (0), there is no software processing and noise can be treated as signal (false counts may be encountered). If set to ON (1), the software takes multiple samples before deciding that an edge is a real edge not noise. The price is drastic reduction in max frequency that can be counted from 800 Hz to 10 Hz.
LUM0017AA Rev I
24
10024 to 10035: Circuitry Protection Active This coil reports the status of circuitry protection on the channel. Circuitry protection is used in Digital Output, Analog Input in current mode, and Sensor Power modes. When this coil is ON (1), if an overload condition has been detected and the channel function is disabled for a short time. Circuitry protection retries the channel function at 10 second intervals to test whether the overload condition has been removed. When the channel is within its limits this register is OFF (0).
30032 to 30047: AI Result, Floating Point This register contains the most recent Analog Input conversion result reported as a floating point number. The decimal number represents the actual voltage in V or current in mA. The setting in registers 121 to 128: AI Current Mode determines whether the channel is used in current or voltage mode. The Floating Point Word Order setting on the Serial Base determines the position of the MSW and LSW in the AI Result, Floating Point registers for all devices in the stack. Regular word order places the MSW at the lower address and the LSW at the higher address (ex: MSW = 30032, LSW = 30033). Inverted word order places the LSW at the lower address and the MSW at the higher address (ex: LSW = 30032, MSW = 30033). When a Radio Base is used then the Long Integer Word Order is forced to regular. This setting allows controllers that require reverse register order to access 32-bit floating point registers without additional programming.
30064 to 30087: DI Counter The DI Counter reports the number of pulse edges seen on a Digital Input. The pulse edge (rising edge or falling edge) that increments the DI Counter is set by coils 96 to 107: DI Counter Falling Edge LUM0017AA Rev I 25
I/O Expansion
Increment. You can read both the MSW and LSW for a 32-bit unsigned integer. Alternatively, you can read the LSW to gain access to a 16-bit unsigned integer result. The maximum counting rate for de-bounced counters is 10 Hz with a minimum pulse width of 40 ms. The maximum counting rate for standard-speed counters is 100 Hz with a minimum pulse width of 4 ms. The maximum counting rate for high-speed counters is 10 kHz with a minimum pulse width of 40 s. Whether a channel is standard-speed or high-speed is determined by the setting of coils 92 to 95: Highspeed DI Counter On Isolated. The Long Integer Word Order setting applies to these registers. See the description under AI Result, Integer for a description of the Long Integer Word Order setting.
30096: Modbus Request Counter This register is a running total of Modbus requests. Every time a Modbus request is received and processed this register is incremented. This is useful for PLCs and RTUs that do not handle Modbus failures appropriately. If the PLC or RTU reports the same number in this register time after time despite continuous polling attempts, then communication has failed between the PLC and the I/O Expansion device.
30112 to 30119: DO Current This register represents the current in milliAmps flowing through Digital Output channels set to ON (1). It is not meant to accurately measure the current to report an approximate current confirming flow.
30152: Device Temperature The temperature of the device circuit board reported as a signed integer with units of 1 C per LSB.
30153: VBATT The supply voltage to the device as an unsigned integer reported in 1 mV per LSB. This is useful to remotely monitor the battery level.
40008 to 40011: Default AO Command The value in this register is the AO Command in default conditions.
LUM0017AA Rev I
26
40016 to 40027: Channel Mode This register sets the channel to be one of the following types: 0 = Off 1 = Digital Output 2 = Digital Input 3 = Analog Output 4 = Analog Input 5 = Sensor Power
40040 to 40047: AI Filter Setting The filter setting turns on filtering (a moving average) for AI Result, Integer and AI Result, Floating Point. Use filtering to reduce signal noise by providing a stable reading. Setting this register to 0 disables filtering. Setting this register to values from 1 to 5 increases the filtering/averaging times: 1 = 10 seconds (0.1 Hz) 2 = 25 seconds (0.04 Hz) 3 = 50 seconds (0.02 Hz) 4 = 100 seconds (0.01 Hz) 5 = 250 seconds (0.004 Hz)
40056 to 40063: Resistor Pull Setting Setting this coil to 1 connects a 10 k pull-down resistor to ground for use with closed-contact-to-voltage inputs and outputs. Setting this coil to 2 connects a 1 k pull-up resistor to 3 V for closed-contact-toground inputs and outputs. Setting this coil to 0 disables both resistors.
40072 to 40075: AO Resolution Use these registers to change the resolution of AO Command. Some PLCs and RTUs support only 16 bits, 14 bits, 12 bits, or signed integers. The AO Command scaling depends on this setting: 0 = 1 A per bit 16-bit resolution 15-bit resolution (This is the recommended setting for PLCs or RTUs that only support 16-bit signed integers.) 14-bit resolution 12-bit resolution
40080 to 40091: DO Monostable Timeout When this register is set to a number other than 0, the mono-stable setting is enabled. Enter the amount of time in milliseconds from 1 to 60000 (1 minute) after which the Digital Output goes to its default state as defined in register 48 to 59: Default DO, Sensor Power State. When this register is set to 0, the Digital Output is bi-stable and the mono-stable time out is no longer enabled. A bi-stable Digital Output maintains the last state until a command is received that changes the Digital Output state.
40096 to 40103: AI ZERO VOLTAGE This register is the voltage that results in the Analog Input reporting 0 in the AI Integer Result register. The scaling factor for this register is 1 mV per bit and the valid range is from 0 to 10000 mV. It is useful for
LUM0017AA Rev I
27
I/O Expansion
translating offset sensors such as 1 to 5 V transmitters so that their minimum output reports 0 in the AI Integer Result register. It is also useful for adjusting AI readings to provide calibration capabilities. See 40104 to 40111: AI Voltage Span for recommended settings with 1 to 5 V and 0 to 10 V sensors.
40104 to 40111: AI VOLTAGE SPAN This register sets the span and scaling factor for AI Integer Result. This register added to AI Zero Voltage is the voltage that results in full scale in AI Integer Result. For 16-bit readings, full scale is 65535, and for 20-bit readings full scale is 1048575. The scaling factor for this register is 1 mV per bit and the valid range is from 0 to 12,500 mV. It is useful for translating sensors such as 1 to 5 V transmitters so their maximum output reports full scale in the AI Integer Result register. Recommended settings for 1 to 5 V sensors: Set AI Zero Voltage to 1000 (equal to 1 V) Set AI Voltage Span is 4000 (equal to 4 V = 5 V 1V) When reading the full 20-bit result, the scaling factor is 3.8147 mV per LSB When reading only the most significant 16 bits, the scaling factor is 61.035 mV per LSB Recommended settings for 0 to 10 V sensors: Set AI Zero Voltage to 0 (equal to 0 V) Set AI Voltage Span to 10000 (equal to 10 V) When reading the full 20-bit result in AI Integer Result, the scaling factor is 3.8147 mV per LSB When reading only the most significant 16 bits in AI Integer Result, the scaling factor is 61.035 mV per LSB For other input ranges or for fine tuning the inputs above: Set AI Zero Voltage to the minimum input voltage Set AI Voltage Span to the input span = maximum input voltage - minimum input voltage When reading the full 20-bit result, the scaling factor is AI Voltage Span / 1048576 When reading only the most significant 16 bits, the scaling factor is AI Voltage Span / 65536 For backwards compatibility, a setting of 0 forces the AI Voltage Span to 10000 mV.
40112 to 40119: AI, AO Zero Current When the channel is used as an Analog Input this register is the current that results in the AnaIog Input reporting 0 in the AI Integer Result register. The scaling factor for this register is 1 A per bit and the valid range is from 0 to 25000 A. This register is useful for translating offset sensors such as 4 to 20 mA transmitters so that their minimum output reports 0 in the AI Integer Result register. It is also useful for adjusting Analog Input readings to provide calibration capabilities. When the channel is used as an Analog Output this register is the current that is output when the AO Command is set to 0. The scaling factor for this register is 1 A per bit and the valid range is from 0 to 25000 A. This register is useful for outputting 4 to 20 mA signals so that their minimum output is 4 mA when AO Command is 0. See the description for 40120 to 40127: AI, AO Current Span for recommended settings with 4 to 20 mA sensors.
LUM0017AA Rev I
28
40120 to 40127: AI, AO Current Span The scaling factor for this register is 1 A per bit and the valid range is from 0 to 25,000 A. This register is useful for translating sensors such as 4 to 20 mA transmitters so that their maximum output reports full scale in the AI Integer Result. For 16-bit readings full scale is 65535, and for 20-bit readings full scale is 1048575. When the channel is used as an Analog Input this register sets the span and scaling factor for AI Integer Result. This register added to AI, AO Zero Current is the input current that results in full scale in the AI Integer Result register. Recommended settings for 4 to 20 mA sensor inputs: Set AI Zero Voltage to 4000 (equal to 4 mA) Set AI Voltage Span to 16000 (equal to 16 mA = 20 mA 4 mA) When reading the full 20-bit result in AI Integer Result, the scaling factor is 15.259 nA per LSB When reading only the most significant 16 bits in AI Integer Result, the scaling factor is 244.14 nA per LSB For all other input ranges or for fine tuning the inputs above: Set AI Zero Voltage to the minimum input voltage Set AI Voltage Span to the output span = maximum input current - minimum input voltage When reading the full 20-bit result in AI Integer Result, the scaling factor is AI Voltage Span / 1048576 When reading only the most significant 16 bits in AI Integer Result, the scaling factor is AI Voltage Span / 65536 When the channel is used as an Analog Output this register sets the span and scaling factor for AO Command. This register added to AI, AO Zero Current is the output current when full scale is entered into AO Command. Recommended settings for 4 to 20 mA outputs: Set AI, AO Zero Voltage to 4000 (equal to 4 mA) Set AI, AO Voltage Span is 16000 (equal to 16 mA = 20 mA 4 mA) When writing all 16 bits in AO Command, the scaling factor is 244.14 nA per LSB When writing all 15 bits in AO Command, the scaling factor is 122.07 nA per LSB When writing all 14 bits in AO Command, the scaling factor is 61.035 nA per LSB When writing all 12 bits in AO Command, the scaling factor is 15.259 nA per LSB For all other output ranges or for fine-tuning the inputs above: Set AI, AO Zero Voltage to the minimum output current Set AI, AO Voltage Span to the output span = maximum input current - minimum input voltage When writing all 16 bits in AO Command, the scaling factor is AI Voltage Span / 65536 When writing all 15 bits in AO Command, the scaling factor is AI Voltage Span / 32768 When writing all 14 bits in AO Command, the scaling factor is AI Voltage Span / 16384 When writing all 12 bits in AO Command, the scaling factor is AI Voltage Span / 4096 For backwards compatibility, a setting of 0 forces the AI, AO Current Span to 20000 A. 40128: Comm Connection The serial port connector type of a Serial Base: RS-232 (0), RS-422 (1), or RS-485 (2).
40129: Comm Timeout Latch In case of communication failure, channels configured as Digital Output, Analog Output, and Sensor Power can be set up to go to default states. This register serves to inform (after communication is LUM0017AA Rev I 29
I/O Expansion
restored) that the communication timeout occurred long enough to activate the defaults. This register remains ON (1) until set to OFF (0) by Modbus command. Setting to 0 clears the latch.
40130: Comm Port Baud Rate The baud rate of the serial port. The default setting is (0) 19200. Options include the following: (0) 19200 (1) 150 (2) 300 (3) 600 (4) 1200 (5) 2400 (6) 4800 (7) 9600 (8) 14400 (9) 19200 (10) 28800 (11) 38400 (12) 57600 (13) 76800 (14) 115200 (15) 153600 (16) 230400
40131: Comm Port Parity The parity of the port connected to the device. Options include the following: (0) None (1) Even (2) Odd
40132: Comm Port Stop Bits There currently is only one selection for Com Port Parity: (1) Even.
40133: Modbus Min Transmit Inter-Message Interval The interval cannot be shorter than 2 ms; regardless of a setting in this register, the interval is automatically adjusted to be shorter than 3.5 character lengths. On the receive side, the interval between messages must be at least 2 ms. If the interval is less than 0.4 ms, received characters will be processed as one message. If the interval is between 0.4 and 2 ms, the Modbus message processing will not be reliable.
40134: RS-485 Turn-On Delay If the Comm Connection register is set to (2) RS-485, set the number of milliseconds (ms) between the RS-485 transmitter turning on and the character transmission start. Set the delay between 0 and 10 ms. The default setting is 1 ms.
LUM0017AA Rev I
30
40135: RS-485 Turn-Off Delay If the Comm Connection register is set to (2) RS-485, set the number of milliseconds (ms) between the RS-485 character transmission end and the transmitter turning off. Set the delay between 0 and 10 ms. The default setting is 1 ms.
LUM0017AA Rev I
31
I/O Expansion
Expansion Module 1 11 14 11 12 11 52 11 52 11 11 11 14 11 43
Expansion Module 2 11 14 11 12 11 52 11 52 11 11 11 14 11 43
Expansion Module 15 11 14 11 12 11 52 11 52 11 11 11 14 11 43
Units ms ms ms ms ms ms ms ms ms ms ms ms ms ms
The output execution delay time is the time it takes a device to execute a command (e.g. change a digital output from low to high). The time is referenced from the moment the complete Modbus command arrives at the data port. Table 7.2.1 Modbus Output Execution Delay Times Modbus Output Execution Delay Serial Time by Device and I/O Type Base Stack ID 0 Non-Isolated Digital Output Command 5 (writing 1 coil) 3 Command 15 (writing 120 coils) 3 Isolated Digital Output Command 5 (writing 1 coil) 17 Command 15 (writing 120 coils) 18 Analog Output Command 6 (writing 1 registers) 3 Command 16 (writing 123 registers) 3
Expansion Module 1 6 8 14 16 6 33
Expansion Module 2 6 8 14 16 6 33
Expansion Module 15 6 8 14 16 6 33
Units ms ms ms ms ms ms
LUM0017AA Rev I
32
Mechanical Information
The following image shows the dimensions for all Serial Base devices, in inches.
LUM0017AA Rev I
33
I/O Expansion
LUM0017AA Rev I
34
LUM0017AA Rev I
35