Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
3
STI No. Page
9700-06E
1 (19)
Introduction
This document describes the designation system used by Siemens Industrial Turbomachinery AB (SIT) for steam turbine deliveries. The system is based on the Kraftwerk-Kennzeichen-System (KKS) and is used for identifying plants, sections of plants and equipment in a clear manner according to their function. The KKS includes three identification types, namely process related identification (function), point of installation identification and location identification. The designation system used does however only use the process related identification of the KKS.
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
3
STI No. Page
9700-06E
2 (19)
System code
The following table describes the system codes normally used. The number of codes used may be increased on project basis depending on scope of supply. Example: MAV21AP005, MAV stands for lubricant supply system. System code B BA BAC10
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
System Power distribution and auxiliary power supply Power distribution Generator circuit breaker LV distribution, UPS AC distribution inverter DC distribution DC distribution 110 V DC distribution 24 V Control equipment Section control system Synchronising equipment Protection Relay protection Turbine protection Unit control Control cubicles Control equipment ABB Master common parts Steam and water cycles Feedwater system Storage, deaeration Feedwater piping system Feedwater pump system Steam system
BR BRU10 BU BUB10 BUE10/20 C CB CBP10 CH CHA10 CHE10 CJ CJJ CR CRB10 L LA LAA LAB LAC LB
3
STI No. Page
9700-06E
3 (19)
System code LBA LBB LBC LBD LBE LBQ LBS LC LCA LCB
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
System Main steam piping system Hot reheat piping system Cold reheat piping system Extraction piping system Back pressure piping system Extraction steam piping system for HP feedwater heating Extraction steam piping system for LP feedwater heating Condensate system Main condensate piping system Main condensate pump system Condensate desuperheating spray system Main machine sets Steam turbine plant HP-turbine system MP-turbine system and IP-turbine system LP-turbine system Condensing system Air removal system HP-turbine gearbox system MP-turbine gearbox system LP-turbine gearbox system HP-turbine/LP-turbine gearbox system (the turbines are connected to the same gearbox) Drain system Leak off steam system Lubricant supply system Sealing, heating and cooling steam system Non-electric control and protection equipment including fluid supply system Turbine governor Turbine automation
LCE M MA MAA MAB MAC MAG MAJ MAK10 MAK20 MAK30 MAK 50 MAL MAM MAV MAW MAX MAY10 MAY20
3
STI No. Page
9700-06E
4 (19)
System Generator system Generator and HV enclosure Exciter system Generator bearing system Voltage regulator Cooling water system Closed cooling water system for conventional area Cooling water system Auxiliary system General instrument air system Instrument air system Ancillary system Ventilation system, conventional area Ventilation system, generator, gearbox and steam turbine room
Q QF QFC S SA SAS
3
STI No. Page
9700-06E
5 (19)
Equipment unit Aggregate Valves, dampers Isolating elements, air locks Heat exchangers, heat transfer surfaces Turning, driving, lifting and slewing gear Heating, cooling and air conditioning units Compressor units, fans Pump units Cleaning, drying, filtering and separating equipment Gear box Expansion bellow Apparatus Storage equipment (tanks) Jet pumps, ejectors, injectors Flow restrictors, limiters, orifices Piping, duct work, chutes Silencers Insulation
AC AE AH AN AP AT AU AZ B BB BN BP BR BS BU
3
STI No. Page
9700-06E
6 (19)
Equipment unit Direct measuring circuits Density Electrical variables Flow, rate Distance, length, position, direction of rotation Manual input as manually operated sensor Time Level Moisture, humidity Pressure Velocity, speed Temperature Vibration expansion Closed loop control circuits Density Flow, rate Distance, length Level Moisture Pressure Velocity, speed Temperature Vibration, expansion Analogue and binary signal conditioning Open loop control Alarm, annunciation Process computer Combined analogue and binary signal conditioning Protection
3
STI No. Page
9700-06E
7 (19)
Equipment unit Electrical equipment Junction boxes and cables (bus bar penetrations) Electrical, instrumentation and control installation units as preprocess system Information display and operator control equipment for process computers and automation systems DC generating equipment, batteries
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
KP01 stands for pump and -M01 stands for electrical motor.
3
STI No. Page
9700-06E
8 (19)
Component key Mechanical equipment All types of valves, rupture discs, orifices Heat exchangers, coolers Vessels, tanks Turning, driving, lifting and slewing gear Fans Pumps Cleaning machines, dryers, separators, filters Mechanical components Gearboxes Piping components, duct work components Electrical actuator, hand actuator, hydraulic actuator, pneumatic actuator Turbines Transmission gear Instrumentation and control components Sensors Signaling devices Controllers, flybolt governor Measuring instruments, testing equipment Instrument piping
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
3
STI No. Page
9700-06E
9 (19)
Component key Signal origins (Free for use) Signal applications (Free for use) Gated signals Gated signal for alarm Gated signal for trip Electrical components
Position indicator, I/P converter (always shown on the P&I diagrams) Thermistor (always shown on the P&I diagrams) AC-motor, DC-motor (always shown on the P&I diagrams) Axial position transducer, D.P. transmitter, D.P. switch, key phasor, level transmitter, level switch, positioner, position switch, pressure switch, pressure transmitter, proximity probe, RTD, speed transducer, temperature switch, thermocouple, thermostat Heater (always shown on the P&I diagrams, except the P&ID's for the generator systems) Amplifier, extension cable, frequency converter, monitor, proximiator Limit switch open (always shown on the P&I diagrams) Limit switch for test purpose Limit switch closed (always shown on the P&I diagrams) Pressure switch for the lube oil purifier, system MAV (always shown on the P&I diagrams) Level switch for the lube oil purifier, system MAV (always shown on the P&I diagrams) Solenoid valve (always shown on the P&I diagrams)
-R01 -U01 -S11, -S12 -S13 -S21, -S22 -S50 -S51 -Y01, -Y02, -Y03
3
STI No. Page
9700-06E
10 (19)
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
Identifications in the measuring symbol The lower part of the measuring circuit symbol specifies the system code of the main and the following KKS unit identification. First letter: C = direct measuring circuits E = signal and measured value processing F = indirect measuring circuits
3
STI No. Page
9700-06E
11 (19)
The second letter specifies the measurement type, F for flow, G for gauging, position or length, L for level, P for pressure or vacuum, S for speed or frequency, T for temperature, Y for vibration. Example:
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
The upper part of the measuring circuit symbol specifies measurement variables in form of letters. For information about measurement quantities see below. Example: Pressure Indicating Emergency Or Safety Acting (Z) Alarm
Description Flow rate, percolation Flow Rate Indicating Gauging, position or length G Indicating G Indicating Control G Indicating Emergency Or Safety Acting (Z) G Indicating Emergency Or Safety Acting (Z) Alarm G Switching
3
STI No. Page
9700-06E
12 (19)
Description G Switching Alarm G Test Measuring Point G Emergency Or Safety Acting (Z) Alarm Level Level Alarm Level Indicating Level Indicating Emergency Or Safety Acting (Z) Alarm Level Switching Level Switching Alarm Level Switching Emergency Or Safety Acting (Z) Level Emergency Or Safety Acting (Z) Level Emergency Or Safety Acting (Z) Alarm Pressure or vacuum Pressure Alarm Pressure Differential Alarm Pressure Differential Indicating Pressure Differential Indicating Alarm Pressure Differential Indicating Control Pressure Differential Indicating Emergency Or Safety Acting (Z) Alarm Pressure Differential Transmitted Pressure Indicating Pressure Indicating Alarm Pressure Indicating Control Pressure Indicating Emergency Or Safety Acting (Z) Alarm Pressure Differential Switching Pressure Differential Emergency Or Safety Acting (Z) Pressure Test Measuring Point Pressure Switching
LSA LSZ LZ LZA P PA PDA PDI PDIA PDIC PDIZA PDT PI PIA PIC PIZA PDS PDZ PP PS
3
STI No. Page
9700-06E
13 (19)
Description Pressure Switching Alarm Pressure Transmitted Pressure Emergency Or Safety Acting (Z) Speed frequency Speed Indicating Control Alarm Speed Indicating Control Emergency Or Safety Acting (Z) Speed Emergency Or Safety Acting (Z) Temperature Temperature Alarm Temperature Control Temperature Element Temperature Indicating Temperature Indicating Alarm Temperature Indicating Control Temperature Indicating Control Alarm Temperature Indicating Control Emergency Or Safety Acting (Z) Alarm Temperature Indicating Switching Alarm Temperature Indicating Emergency Or Safety Acting (Z) Temperature Indicating Emergency Or Safety Acting (Z) Alarm Temperature Test - Measuring Point Temperature Switching Temperature Emergency Or Safety Acting (Z) Vibration Y Indicating Emergency Or Safety Acting (Z) Alarm
3
STI No. Page
9700-06E
14 (19)
Identifications for alarm and trip at lower and upper limits Example: H2 = trip at upper limit H1 = alarm at upper limit L1 = alarm at lower limit L2 = trip at lower limit
Example:
Spare RTD
3
STI No. Page
9700-06E
15 (19)
Isolating valve
Rupture disc
3-way valve
Diaphragmcontrolled valve
Liquid pump
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
4-way valve
Centrifugal pump
Throttle valve
Fan
Ejector
3
STI No. Page
9700-06E
16 (19)
Floor drain
Pneumatic positioner
Fail to close
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
Outlet to atmosphere
Spray nozzle
Directional control valve. 4 ports 2 distinct positions. Directional control valve. 3 ports 2 distinct positions.
Filter or strainer
3
STI No. Page
9700-06E
17 (19)
Flow restriction
Design data
Filter
Flash tank
Flow directions
3
STI No. Page
9700-06E
18 (19)
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
Hydraulic pump variable capacity and pressure compensator one flow direction
To/from pipe or system Hydraulic pump variable capacity one flow direction
Siemens
system nr.
Spring accumulator
Separator
3
STI No. Page
9700-06E
19 (19)
Remote instrument
Local instrument
Heater
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third Parties without express authority is strictly forbidden. Siemens Industrial Turbomachinery AB
Condenser or heater