Linear separable LED strip on flexible printed circuit board with self-adhesive back Compact and powerful LED lightsource Available in white, 2 colour temperatures
Applications
Current [A]* 2 3 3 3 3
Wavelength [nm] Color Temp [K]* 5400 K 5400 K 4000 K 3000 K 2700 K
*) All Data are related to the entire module Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. +) Preliminary Data **) Discontinued
Technical Features
Size of printed circuit board Linear LED strip on flexible printed circuit board
(L x W x H): 2800 mm x 10 mm x 3 mm
Size of smallest unit 6 LED
(L x W): 140 mm x 10 mm
Entire Module consists of 120 LEDs LED grid: 23,3 mm Smallest unit of 6 LEDs can be cut out at regular
CONNECTsystem LM-xx Flex: Feeder LM-2PIN Flex, connector LM-CONN-10 Flex and LMCONN-150 Flex.
Up to 20,000 h lifetime for Tc<85C
LM10P - 10.03.2010
Page 1 of 4
Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module. Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module. The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below.
Drawings
LM10P - 10.03.2010
Page 2 of 4
Safety Information
The LED module itself and all its components must not be mechanically stressed. Assembly must not damage or destroy conducting paths on the circuit board.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically stabilised power supply protecting against short circuits, overload and overheating. To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. Please see the relevant brochure for more detailed information (see "Related and Further Information")
OSRAM OPTOTRONIC electronic control gear complies to all relevant standards and guarantees safe operation. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Observe correct polarity! Depending on the product incorrect polarity will lead to emission of red or no light. The module can be destroyed! Correct polarity immediatelly! (see "reverse voltage", page 2) Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module. The maximum length of LM10P is 1400 mm (72 W version) and 2800 mm (48 W version) with power feed at one end. The complete module 2800 mm (72 W version) can be operated with a two pole power feed in the middle of the module or from both ends, when only one power supply is used. For the 48 W version a total length of 4.2 m (1.5 reels) can be operated with a two or three pole power feed using one power supply considering the maximum allowed module length. When mounting on metallic or otherwise conductive surfaces, there needs to be a electrical isolation at soldering points between module and the mounting surface. Pay attention to standard ESD precautions when installing the module. Please ensure that the power supply is of adequate power to operate the total load. The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. The ability to customize the length of the module by cutting at specifically marked points is a key feature of the product and hence the reason for no factory installed conformal coating. For these reasons, it is recommended that the user complete all module modifications first (cutting, wiring) and then apply a conformal coating in the final stages of installation. Damage by corrosion will not be honored as a materials defect claim. It is the users responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements. For applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable protection class. The module can be protected against condensation water by treatment with an appropriate circuit board grade conformal coating. The conformal coating should have the following features: - Optical transparency - UV-resistance - thermal expansion matching the thermal expansion of the module 15-30*10^-6 cm/cm/K - low permeability of steam for all climatic conditions - resistance against corrosive environment
LM10P - 10.03.2010
Page 3 of 4
Assembly Information
The smallest unit (140 mm / 6 LEDs) can be removed by cutting with scissors between the designated solder pads. Connection with soldering wires on unmounted module: Do not pretin the solderpads but pretin the wires and solder for max 4 s at 300 C. Allow solderpoints to completely cool down before the next soldering. Prevent shear- or peel forces. Soldering of wires with the module mounted on a heatsink: Pretin solderpads and wires and solder for max 3 s at 350 C. Allow solderpoints to completely cool down before the next soldering. Prevent shear- or peel forces. The mounting of the module is facilitated by means of the double-sided adhesive on the back-surface of the module. Care must be taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt particle. The mounting substrate must have sufficient structural integrity. Take care to completely remove the adhesive backing. Once the module is appropriately positioned, press on the module with about 20N/cm (refer to application techniques of 3M adhesive transfer tapes). The module has to be mounted on a metal heat sink! The thermal length expansion coefficient of the modul is 17*10^-6cm/cm/K. When installing in environments with large variations in temperature (e.g. outdoor applications) and operating length of more than 2 m, the use of metallic mounting surfaces is necessary. Otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion coefficients. The minimum bending radius is 2 cm. The module may be bent over a smaller radius but only in regions of the circuit board containing no electronic components and such bends should be made once and fixed in position to avoid cyclic fatigue.