A ut omation C omponents Product Data I nc.

Matched Temperature Transmitters

ACI/TTM100 ACI/TTM1000

Product Description
The ACI/TTM100 and ACI/TTM1000 Series transmitters provide a highly accurate current output. To obtain the high accuracy, the transmitter is calibrated while the sensor is in an environmental chamber. The standard deviation is then documented on a Certificate of Calibration at 3 points as compared to an NIST Traceable thermometer. Each unit includes a two-wire Class A RTD that conforms to IEC 751 platinum RTD standards. A matched transmitter works with either a 100 or 1000 Ohm RTD. The transmitter produces a linear 4-20 mA output carried on a two-wire system. Optional output voltage ranges (1-5 or 2-10 VDC) can also be ordered. The input to the transmitter may vary from 7 to 35 VDC, can be unregulated, and is not polarity sensitive. The transmitter is supplied factory calibrated, for any range between -50 to 392oF. The current output is unsusceptible to both EMI and

load resistances less than 800 Ohms. Additional options include current limiting and an AC power input. The transmitter is available in numerous configurations to satisfy all the industry standards. The room transmitter is encased in an unobtrusive, plastic enclosure and can be equipped with a 4-20 mA setpoint and Tenant override. The transmitter can be ordered on a surface plate made of either stainless steel or aluminum. For measuring pipe temperature, TTs can be ordered with a strap. For air duct measurements, our TTs are offered with a 4, 8, 12, and 18 probe or as a remote probe with 6 leads. Averaging configurations are available in 12 and 24 lengths, made of soft copper tubing to fit in any duct. Lastly, the TTs can be ordered as immersion type sensors that include a 2.5, 4, or 8 high quality stainless steel thermowells. Duct and outside air configurations are available inside a NEMA4 or NEMA 4X weatherproof enclosure. Please specify when ordering
Sensor OperatingRange Single Point -58 to 392 oF

Product Specifications
Input 2-wire Platinum 100/1000 Ohm Class A RTD 2-wire, Linear 4 to 20mA DC Current Output Supply Voltage 7 to 35 VDC, No Polarity Sensitivity +/- 0.05% of span Linearity

Sensor Accuracy Transmitter Accuracy Transmitter Operating Range

Sensor OperatingRange Averaging

0.06% @ 32oF (Class A) +/- 0.1% of span 32 to 158oF

-50 to 275 oF

2305 Evergreen Rd. Middleton Industrial Park Middleton, WI 53562 PH: (608) 831-2585 FAX (608) 831-7407

T-37

Dimensions
Room
2.25
.79

1.15 .89

Stainless Plate
1/8 Foam Insulation Pad

4.50

3.84

4.51

1.70

2.75

0.90 0.760

4.0

2.75

0.60 .92

Thermowell
2.50 4.0 6.25 NPT Male (Process) 0.375 Cross-Sectional View

Immersion
1.02 NPSM Female (Instrument) 0.76

0.25 Male NPT Threads 1.70 2.151 Conduit Knockouts 4.0 Male NPT Nylon Fitting 4.541

Outside Air

2.77

Strap-On

(2) 0.625W x 0.50L

Worm Gear

5
1.5 x 1.5 Foam Pad

1.158 4.81

1.7

Ordering Information
A/
Sensor

Span

Configuration

Output

TTM100 (100 Ohm RTD) TTM1K (1000 Ohm RTD)

(1) 40 to 90o (2) 30 to 100o (3) 20 to 120o (4) 40 to 140o (5) 40 to 240o (6) -30 to 130o (7) 0 to 150o (8) Specify

R- Room (1) 1 to 5 VDC RO- Room w/ Override (2) 2 to 10 VDC RS- Room w/ Setpoint (4) 4 to 20 mA RSO- Room w/ Setpoint, Override D- Duct - 4, 8, 12, 18 I- Immersion 2.5, 4, 8 S- Strap-On O- Outside Air A- Averaging 12, 24 SP- Stainless Plate RP- Remote Probe A/TTM100 -(5) -I -4 -(4)

Example: A/TTM1000 -(40 to 90) -I -4 -(4)

or

T-38

2305 Evergreen Rd. Middleton Industrial Park Middleton, WI 53562 PH: (608) 831-2585 FAX (608) 831-7407