Sei sulla pagina 1di 40

Submersible Pump in Discharge Tube

Amacan P
50 Hz

General Arrangement
Drawings

Legal information/Copyright
General Arrangement Drawings Amacan P

KSB Aktiengesellschaft
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a
third party without KSB's express written consent.
Subject to technical modification without prior notice.
KSB Aktiengesellschaft Frankenthal 24.09.2012

Contents

Contents
Water: Water Transport .................................................................................................................................... 4
Submersible Pump in Discharge Tube ........................................................................................................................... 4
Amacan P ................................................................................................................................................................... 4
Designation .......................................................................................................................................................... 4
Selection information .......................................................................................................................................... 4
Installation types .................................................................................................................................................5
General arrangement drawings ......................................................................................................................... 6
BU type of installation (500-270 to 600-350) ...............................................................................................6
BU type of installation (700-470 to 1500-1060) ...........................................................................................9
BG type of installation (500-270 to 600-350) .............................................................................................12
BG type of installation (700-470 to 1500-1060) .........................................................................................14
CU type of installation (500-270 to 600-350) .............................................................................................16
CU type of installation (700-470 to 1500-1060) .........................................................................................19
CG type of installation (500-270 to 600-350) .............................................................................................22
CG type of installation (700-470 to 1500-1060) .........................................................................................24
DU type of installation (500-270 to 600-350) ............................................................................................. 27
DU type of installation (700-470 to 1500-1060) ......................................................................................... 30
DG type of installation (500-270 to 600-350) ............................................................................................. 33
DG type of installation (700-470 to 1500-1060) ......................................................................................... 35
Dimensions of the flow-straightening vane ............................................................................................... 38

Water: Water Transport


Submersible Pump in Discharge Tube

Water: Water Transport


Submersible Pump in Discharge Tube

Amacan P

Selection information
Information for pump selection
The guaranteed point of submersible pumps in discharge tubes
is measured at a head 0.5 m above the motor (DIN 1184). The
documented characteristic curves refer to this data. This must
be taken into account when calculating system losses. The indicated heads and performance data apply to pumped fluids
with a density = 1 kg/dm3 and a kinematic viscosity of up to
20 mm2/s.
The pump input power must be matched to the density of the
fluid handled:
P2req = fluid [kg/dm3] x P2docu
The operating point with the largest pump input power is decisive for the operating range of the motor. To compensate the
unavoidable tolerances of the characteristic curves of system,
pump and motor we recommend selecting a motor size which
provides sufficient power reserves.
Recommended minimum reserves1)
Required pump input power

Motor power reserve

[kW]

Mains operation

< 30
> 30

10 %
5%

With frequency inverter


15 %
10 %

Intake chamber

Designation
Example: Amacan PA4 800-540 / 120 6UTG1
Key to the designation
Code
Amacan
P
A

4
800
540
120
6

UT

G1

1)

Description
Type series
Impeller type, e.g. P = propeller
Pressure class
A
B
Number of vanes
Nominal diameter of the discharge tube [mm]
Nominal impeller diameter [mm]
Motor size
Number of motor poles
4
4-pole
6
6-pole
8
8-pole
10 10-pole
12 12-pole
14 14-pole
Motor version
UA Without explosion protection, standard
(sizes 500-270 ... 600-350)
XA Explosion protection to ATEX
(sizes 500-270 ... 600-350)
UT Without explosion protection, standard
(sizes 700-470 ... 1500-1600)
XT Explosion protection to ATEX
(sizes 700-470 ... 1500-1600)
Material variants
G1 Grey cast iron, standard material variant
G3 Grey cast iron with Zn anodes, shaft made of
1.4057 stainless steel

Determine the minimum water level t1min(diagram in general


arrangement drawing):
The minimum water level t1min is the water level required in the
pump's suction chamber to ensure:
that there is a sufficient liquid cover above the hydraulic
system (propeller) (shown in diagram depending on pump
size)
that the pump does not draw in air-entraining vortices
(shown in diagram depending on flow rate)
that there is no cavitation in the hydraulic system (check
against the NPSHrequired value indicated in the technical literature).
The following conditions must be met:
NPSHavailable > NPSHrequired + safety allowance
NPSHavailable = 10.0 + (t1 - t3 - h7/2)
Safety allowance:
up to Qopt 0.5 m
larger than Qopt 1.0 m

Head (H)
The total pump head is composed as follows:
H = Hgeo + HV
Hgeo (static head)
Without discharge elbow Difference between suctionside water level and overflow edge
With discharge elbow Difference between suction-side
and discharge-side water level
HV (losses in the system)
Starting 0.5 m downstream of the pump: e.g. pipe friction,
elbow, swing check valve, etc.

Losses by inlet, riser and elbow


Losses are caused by the inlet, riser and elbow (or free discharge).

If larger reserves are stipulated by local regulations or are required to compensate for uncertain factors in system calculations, these larger reserves must be provided.

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Losses in the riser up to the indicated reference level (0.5
m above the motor) are taken into account in the documented characteristic curves.
Inlet and elbow losses are system losses and must be taken
into account for selection.

For information on structural requirements, pump installation and pump sump design please refer to the KSB knowhow brochure "Planning information: Amacan submersible pumps in discharge tubes" 0118.55.

Installation types
Overview of installation types

BU discharge tube
Overflow design with open intake chamber

BG discharge tube
Overflow design with covered intake chamber

CU discharge tube
Underfloor discharge with open intake chamber

CG discharge tube
Underfloor discharge with covered intake chamber

DU discharge tube
Above floor discharge nozzle with open intake chamber

DG discharge tube
Above floor discharge nozzle with covered intake chamber

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
General arrangement drawings
BU type of installation (500-270 to 600-350)

P2

d12

P2

100

Foundation recesses2)
A-A

t4

100

1
t2

Y
h7

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

e1

h7

B-B

45

d8
d9
l

t3

t1

350

Hgeo

ha

P1

d7

Detailed view Y:
seat ring

b1

0 - 10
vmax. = 1 m/s
b2

Minimum water level (values see diagram on the next page)


Flow-straightening vane ( Page 38)
Approach flow
Dimensions [mm]
Size

500 - 270
600 - 350

2)

508
610

750
1250

b1

b2

without suction
umbrella
d8

with suction umbrella


d9

without suction
umbrella
d8

with suction umbrella


d9

150
250

150
250

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.

Amacan P

d7

d8

d9

400
500

505
610

650
800

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

d12

e13)

ha

h7

lmin.

p1

p2

t33)

t4 min.4)

100
100

295
540

400
850

600
700

700
800

440
540

200
320

1600
1900

without suction um- with suction umbrelbrella


la
d8
d9
500 - 270
600 - 350

550
650

350
400

400
500

Welded design: B/F to DIN EN ISO 13920

t2 = 1.1 x water level, maximum 2 x t1


Height of corner lining (b1 and b2) like t2

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Permissible tolerances:
Tolerances in building construction to DIN 18202, Part 4,
Group B

Loss diagram
2

DA

DA = 400 mm

h [m]

DA = 600 mm

DA = 800 mm
DA = 1000 mm
DA = 1200 mm
DA = 1400 mm
DA = 1600 mm
DA = 1800 mm
DA = 2000 mm
DA = 2200 mm

1
0,8

Overflow head
h

0,6
0,5
0,4
0,3

0,2

0,1
0,1

0,2

0,3

0,4 0,5 0,6

0,8

1 Q [m3/s]

5 6

Loss diagram

Calculation formulas:
H = Hgeo + Hv
Hv

Overflow head h (see diagram)


Loss in the riser (pipe friction)

Outlet loss v2/2 g (v refers to DA)


Overflow head h depends on Q and the discharge diameter DA. The characteristic curve values only apply to unimpeded outlet in
all directions; otherwise they are approximate values only.

3)
4)

Always observe this dimension.


Value for maximum motor length

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum fluid level diagrams
Open intake chamber
(design without suction umbrella d8)

Open intake chamber


(design with suction umbrella d9)

Key

t1 [mm]
4000

t1 [mm]
4000

1 - Amacan P 500-270
2 - Amacan P 600-350

3000
2500

3000
2500

2000
1600

2000
1600

1200
1000

1200
1000

800

800 1

600
500

600
500

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

Amacan P

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

Water: Water Transport


Submersible Pump in Discharge Tube
BU type of installation (700-470 to 1500-1060)

P2

d12

P2

100

Foundation recesses5)
A-A

t4

100

1
t2

Y
B

h7

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

e1

h7

B-B

45

d8
d9
l

t3

t1

350

Hgeo

ha

P1

d7

Detailed view Y:
seat ring

b1

0 - 10
vmax. = 1 m/s
b2

: Minimum water level (values see diagrams on the following pages)


: Flow-straightening vane ( Page 38)
: Approach flow
Dimensions [mm]
Size

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

5)

711
813
914
1016
1220
1524

1500
1800
1800
2300
2800
3500

b1

b2

without suction
umbrella
d8

with suction
umbrella
d9

without suction
umbrella
d8

with suction
umbrella
d9

300
360
360
460
560
700

300
360
360
460
560
700

d7

d8

d9

d12

600
680
700
880
1070
1330

710
810
910
1015
1220
1520

1100
1250
1250
1600
2000
2450

750
850
970
1070
1280
1590

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

h7

ha

lmin.

p1

p2

t36)

t4 min.7)

420
525
515
765
1000
1460

100
100
100
100
100
100

1050
1300
1300
1700
2100
2650

800
910
1050
1150
1360
1680

900
1000
1120
1220
1420
1750

640
740
860
960
1160
1480

380
440
440
560
680
860

2300
2350
2500
3050
3750
3800

e16)
without suction um- with suction umbrelbrella
la
d8
d9

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

450
500
550
600
700
850

650
700
700
900
1100
1300

Welded design: B/F to DIN EN ISO 13920

t2 = 1.1 x water level, maximum 2 x t1


Height of corner lining (b1 and b2) like t2

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Permissible tolerances:
Tolerances in building construction to DIN 18202, Part 4,
Group B

Loss diagram
2

DA

DA = 400 mm

h [m]

DA = 600 mm

DA = 800 mm
DA = 1000 mm
DA = 1200 mm
DA = 1400 mm
DA = 1600 mm
DA = 1800 mm
DA = 2000 mm
DA = 2200 mm

1
0,8

Overflow head
h

0,6
0,5
0,4
0,3

0,2

0,1
0,1

0,2

0,3

0,4 0,5 0,6

0,8

1 Q [m3/s]

5 6

Loss diagram

Calculation formulas:
H = Hgeo + Hv
Hv

Overflow head h (see diagram)


Loss in the riser (pipe friction)

Outlet loss v2/2 g (v refers to DA)


Overflow head h depends on Q and the discharge diameter DA. The characteristic curve values only apply to unimpeded outlet in
all directions; otherwise they are approximate values only.

6)
7)

10

Always observe this dimension.


Value for maximum motor length

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum fluid level diagrams
Open intake chamber
(design without suction umbrella d8)

Key

t1 [mm]
4000

3 - Amacan P 700 - 470


4 - Amacan P 800/900 - 540
5 - Amacan P 1000 - 700
6 - Amacan P 1200 - 870
7 - Amacan P 1500 - 1060

3000
2500
2000
1600

1200
1000
800
600
500
400

0,1

0,2

0,3 0,4

0,6 0,8 1

1,5

2 2,5 3

4 5 6 7 8
Q [m3/s]

1,5 2 2,5 3

4 5 6 78
Q [m3/s]

Open intake chamber


(design with suction umbrella d9)

t1 [mm]
4000
3000
2500
2000
1600

5
3

1200
1000

800
600
500
400

0,1

0,2

0,3 0,4

0,6 0,8 1

Amacan P

11

Water: Water Transport


Submersible Pump in Discharge Tube
BG type of installation (500-270 to 600-350)

P2

d12

P2

ha

100

P1

100

t9

t1

45

t3 h7

e2

d10

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

45

B-B
e1

h7

350

t4

Hgeo

Foundation recesses8)
A-A

d7
d8

0 - 90
vmax. = 1 m/s

b2

b1

Detailed view Y:
seat ring

Minimum water level (values see diagram on the next page)


Flow-straightening vane ( Page 38)
Approach flow
Dimensions [mm]
Size
500 - 270
600 - 350

b1

b2

d7

d8

d10

d12

e19)

e2

508
610

750
1250

150
250

300
500

400
500

505
610

540
640

550
650

259
375

375
625

ha

h7

lmin.

p1

p2

t39)

t4 min.10)

t9

100
100

295
540

750
1250

600
700

700
800

440
540

200
320

1600
1900

280
470

Dimensions [mm]
Size
500 - 270
600 - 350

Permissible tolerances:

8)
9)
10)

12

Tolerances in building construction to DIN 18202, Part 4,


Group B

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
Always observe this dimension.
Value for maximum motor length

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Welded design: B/F to DIN EN ISO 13920

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Loss diagram
DA

2
DA = 400 mm

h [m]

DA = 600 mm

DA = 800 mm
DA = 1000 mm
DA = 1200 mm
DA = 1400 mm
DA = 1600 mm
DA = 1800 mm
DA = 2000 mm
DA = 2200 mm

1
0,8
0,6

0,5

Overflow head
h

0,4
0,3

0,2

0,1
0,1

0,2

0,3

0,4 0,5 0,6

0,8

1 Q [m3/s]

5 6

Loss diagram

Calculation formulas:
H = Hgeo + Hv
Hv

Overflow head h (see diagram)


Loss in the riser (pipe friction)

Outlet loss v2/2 g (v refers to DA)


Overflow head h depends on Q and the discharge diameter DA. The characteristic curve values only apply to unimpeded outlet in
all directions; otherwise they are approximate values only.

Minimum water level diagram


Covered intake chamber

Key
1 - Amacan P 500-270
2 - Amacan P 600-350

t1 [mm]
4000
3000
2500
2000
1600
1200
1000
800
600
500

2
1

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

Amacan P

13

Water: Water Transport


Submersible Pump in Discharge Tube
BG type of installation (700-470 to 1500-1060)

P2

d12

P2

ha

100

P1

100

t9

t1

45

t3 h7

e2

d10

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

45

B-B
e1

h7

350

t4

Hgeo

Foundation recesses11)
A-A

d7
d8

0 - 90
vmax. = 1 m/s

b2

b1

Detailed view Y:
seat ring

: Minimum water level (values see diagrams on the following pages)


: Flow-straightening vane ( Page 38)
: Approach flow
Dimensions [mm]
Size
700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

b1

b2

d7

d8

d10

d12

e112)

e2

711
813
914
1016
1220
1524

1500
1800
1800
2300
2800
3500

300
360
360
460
560
700

600
720
720
920
1120
1400

600
680
700
880
1070
1330

710
810
910
1015
1220
1520

740
860
960
1080
1290
1600

750
850
970
1070
1280
1590

450
519
519
673
833
1048

750
900
900
1150
1400
1750

Dimensions [mm]
Size
700 - 470
800 - 540

11)
12)
13)

14

ha

h7

lmin.

p1

p2

t312)

t4 min.13)

t9

100
100

420
525

1500
1800

800
910

910
1000

640
740

380
440

2300
2350

570
660

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
Always observe this dimension.
Value for maximum motor length

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Size
900 - 540
1000 - 700
1200 - 870
1500 - 1060

ha

h7

lmin.

p1

p2

t312)

t4 min.13)

t9

100
100
100
100

515
765
1000
1460

1800
2300
2800
3500

1050
1150
1360
1680

1120
1220
1420
1750

860
960
1160
1480

440
560
680
860

2500
3050
3750
3800

660
850
1050
1320

Welded design: B/F to DIN EN ISO 13920

Permissible tolerances:
Tolerances in building construction to DIN 18202, Part 4,
Group B

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Loss diagram
DA

2
DA = 400 mm

h [m]

DA = 600 mm

DA = 800 mm
DA = 1000 mm
DA = 1200 mm
DA = 1400 mm
DA = 1600 mm
DA = 1800 mm
DA = 2000 mm
DA = 2200 mm

1
0,8
0,6

0,5

Overflow head
h

0,4
0,3

0,2

0,1
0,1

0,2

0,3

0,4 0,5 0,6

0,8

1 Q [m3/s]

5 6

Loss diagram

Calculation formulas:
H = Hgeo + Hv
Hv

Overflow head h (see diagram)


Loss in the riser (pipe friction)

Outlet loss v2/2 g (v refers to DA)


Overflow head h depends on Q and the discharge diameter DA. The characteristic curve values only apply to unimpeded outlet in
all directions; otherwise they are approximate values only.

Minimum water level diagram


Covered intake chamber

Key
3 - Amacan P 700 - 470
4 - Amacan P 800/900 - 540
5 - Amacan P 1000 - 700
6 - Amacan P 1200 - 870
7 - Amacan P 1500 - 1060

t1 [mm]
4000
3000
2500
2000
7

1600

6
5

1200

1000
900
800
700
600
500
400

13)

0,1

0,2

0,3 0,4 0,5 0,6 0,8 1

1,5

2 2,5 3

6 7 8
Q [m3/s]

Value for maximum motor length

Amacan P

15

Water: Water Transport


Submersible Pump in Discharge Tube
CU type of installation (500-270 to 600-350)

p2
p1

a2

t4

200

Section A - A:

t3

h7

t2

d8

m1

d9

B-B
e1

45

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

b1

h7

250

200

Foundation recesses14)
300

t1

a1

200

DN2

Hgeo

a3

5
t5

0 - 10
vmax. = 1 m/s

d7

Detailed view Y:
seat ring

b2
: Vent line
: Minimum water level (values see diagram on the next page)
: Flow-straightening vane ( Page 38)
: Approach flow
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size

DN2 min.

500 - 270
600 - 350

14)
15)

16

300
350

DN2 max.

500
600

508
610

530
580

a115)

880
1000

a215)

630
750

a315)

325
380

750
1250

b1

b2

without
suction umbrella
d8

with suction umbrella


d9

without
suction umbrella
d8

with suction umbrella


d9

150
250

150
250

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
Designed for DN 2 min.

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

d7

500 - 270
600 - 350

d8

d9

h7

e116)
without
suction
umbrella
d8

with suction umbrella


d9

350
400

400
500

400 505 650


500 610 800

lmin.

m15)

m115)

n15)

p115) p215) t316)

295 400
540 850

930
1050

350
405

1060
1160

760
860

860
960

200
320

t4 min.17)

t5 min.15)

1700
2000

670
720

t2 = 1.1 x water level, maximum 2 x t1


Height of corner lining (b1 and b2) like t2

Welded design: B/F to DIN EN ISO 13920

Permissible tolerances:

Discharge flanges to DIN EN 1092-1 PN6 / DIN EN


1092-2 PN6

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Tolerances in building construction to DIN 18202, Part 4,


Group B

Loss diagram
2,5

2,0

9 10 11 12

14

13

15

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

16
17

HV ges [m]
1,0
0,8
0,6
0,5
0,4
0,3

0,2

0,1

0,1

0,2

0,3

0,4 0,5 0,6

0,8 1

Q [m3/s]

Calculation formulas:
H = Hgeo + Hv
Hv

Loss in the riser (pipe friction)

HV ges. comprises:

Hv ges. (see diagram)


Elbow

Discharge pipe length = 5 x DN2


Swing check valve
Outlet losses v2/2g

16)
17)

Always observe this dimension.


Value for maximum motor length

Amacan P

17

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum fluid level diagrams
Open intake chamber
(design without suction umbrella d8)

Open intake chamber


(design with suction umbrella d9)

Key

t1 [mm]
4000

t1 [mm]
4000

1 - Amacan P 500-270
2 - Amacan P 600-350

3000
2500

3000
2500

2000
1600

2000
1600

1200
1000

1200
1000

800

800 1

600
500

600
500

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

18

Amacan P

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

Water: Water Transport


Submersible Pump in Discharge Tube
CU type of installation (700-470 to 1500-1060)

p2
p1

a2

t4

200

Section A - A:

t3

h7

t2

d8

m1

d9

B-B
e1

45

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

b1

h7

250

200

Foundation recesses18)
300

t1

a1

200

DN2

Hgeo

a3

5
t5

0 - 10
vmax. = 1 m/s

d7

Detailed view Y:
seat ring

b2
: Vent line
: Minimum water level (values see diagram on the following pages)
: Flow-straightening vane ( Page 38)
: Approach flow
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

18)
19)

DN2

DN2

min.

max.

400
500
600
700
900
1200

700
800
900
1000
1200
1500

a119)

a219)

a319)

b1

b2

without suc- with suction without suc- with suction


tion umbrel- umbrella tion umbrel- umbrella
la
d9
la
d9
d8
d8
711
813
914
1016
1220
1524

650
700
760
810
910
1060

1120
1220
1320
1430
1630
1960

870
970
1070
1160
1360
1690

430
480
530
580
680
850

1500
1800
1800
2300
2800
3500

300
360
360
460
560
700

300
360
360
460
560
700

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
Designed for DN 2 min.

Amacan P

19

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

d7

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

d8

600
680
700
880
1070
1330

d9

710
810
910
1015
1220
1520

h7

e120)
without
suction
umbrella
d8

with suction umbrella


d9

450
500
550
600
700
850

650
700
700
900
1100
1300

1100
1250
1250
1600
2000
2450

420
525
515
765
1000
1460

lmin.

m19)

1050
1300
1300
1700
2100
2650

1170
1270
1380
1520
1720
2050

m119)

n19)

455
505
560
625
725
895

1260
1375
1480
1620
1850
2180

p119)

p219)

t320)

t4 min.

t5 min.

21)

19)

960
1075
1180
1280
1510
1840

1060
1175
1280
1380
1610
1940

380
440
440
560
680
860

2400
2450
2650
3250
4000
4050

770
835
925
980
1100
1300

t2 = 1.1 x water level, maximum 2 x t1


Height of corner lining (b1 and b2) like t2

Welded design: B/F to DIN EN ISO 13920

Permissible tolerances:

Discharge flanges to DIN EN 1092-1 PN6 / DIN EN


1092-2 PN6

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Tolerances in building construction to DIN 18202, Part 4,


Group B

Loss diagram
2,5

2,0

9 10 11 12

14

13

15

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

16
17

HV ges [m]
1,0
0,8
0,6
0,5
0,4
0,3

0,2

0,1

0,1

0,2

0,3

0,4 0,5 0,6

0,8 1

Q [m3/s]

Calculation formulas:
H = Hgeo + Hv
Hv

Loss in the riser (pipe friction)

HV ges. comprises:

Hv ges. (see diagram)


Elbow
Discharge pipe length = 5 x DN2
Swing check valve
Outlet losses v2/2g

20)
21)

20

Always observe this dimension.


Value for maximum motor length

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum fluid level diagrams
Open intake chamber
(design without suction umbrella d8)

Key

t1 [mm]
4000

3 - Amacan P 700 - 470


4 - Amacan P 800/900 - 540
5 - Amacan P 1000 - 700
6 - Amacan P 1200 - 870
7 - Amacan P 1500 - 1060

3000
2500
2000
1600

1200
1000
800
600
500
400

0,1

0,2

0,3 0,4

0,6 0,8 1

1,5

2 2,5 3

4 5 6 7 8
Q [m3/s]

1,5 2 2,5 3

4 5 6 78
Q [m3/s]

Open intake chamber


(design with suction umbrella d9)

t1 [mm]
4000
3000
2500
2000
1600

5
3

1200
1000

800
600
500
400

0,1

0,2

0,3 0,4

0,6 0,8 1

Amacan P

21

Water: Water Transport


Submersible Pump in Discharge Tube
CG type of installation (500-270 to 600-350)

a3
p2
p1

t5

a1

DN2

A
Hgeo

200

Foundation recesses22)
300

a2

200

200

45

Section A - A:

t9

t1

t3 h7

250

t4

d10
e2

m1
m

B-B
e1

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

45

h7

d7

b2

d8

b1

0 - 90
vmax. = 1 m/s

Detailed view Y:
seat ring

: Vent line
: Minimum water level (values see diagram on the next page)
: Flow-straightening vane ( Page 38)
: Approach flow
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size
500 - 270
600 - 350

DN2 min.

DN2 max.

a123)

a223)

a323)

b1

b2

d7

d8

d10

300
350

500
600

508
610

530
580

880
1000

630
750

325
380

750
1250

150
250

300
500

400
500

505
610

540
640

Dimensions [mm]
Size

e124)

e2

h7

lmin.

m23)

m123)

n23)

p123)

p223)

t324)

t4 min.25)

t5 min.23)

t9

500 - 270
600 - 350

259
375

375
625

295
540

750
1250

930
1050

350
405

1060
1160

760
860

860
960

200
320

1700
2000

670
720

280
470

22)
23)
24)
25)

22

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
Designed for DN 2 min.
Always observe this dimension.
Value for maximum motor length

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Tolerances for conical seat (detailed view Y): ISO 2768-mH

Permissible tolerances:
Tolerances in building construction to DIN 18202, Part 4,
Group B

Discharge flanges to DIN EN 1092-1 PN6 / DIN EN


1092-2 PN6

Welded design: B/F to DIN EN ISO 13920

Loss diagram
2,5

2,0

9 10 11 12

14

13

15

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

16
17

HV ges [m]
1,0
0,8
0,6
0,5
0,4
0,3

0,2

0,1

0,1

0,2

0,3

0,4 0,5 0,6

0,8 1

Q [m3/s]

Calculation formulas:
H = Hgeo + Hv
Hv

Loss in the riser (pipe friction)

HV ges. comprises:

Hv ges. (see diagram)


Elbow

Discharge pipe length = 5 x DN2


Swing check valve
Outlet losses v2/2g

Minimum water level diagram


Covered intake chamber

Key
1 - Amacan P 500-270
2 - Amacan P 600-350

t1 [mm]
4000
3000
2500
2000
1600
1200
1000
800
600
500

2
1

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

Amacan P

23

Water: Water Transport


Submersible Pump in Discharge Tube
CG type of installation (700-470 to 1500-1060)

a3
p2
p1

t5

a1

DN2

A
Hgeo

1
D

a2

200

200

Foundation recesses26)
300

200

45

Section A - A:

t9

t1

t3 h7

250

t4

d10
e2

m1
m

B-B
e1

Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

45

h7

d7
d8

b1

0 - 90
vmax. = 1 m/s

b2

Detailed view Y:
seat ring

: Vent line
: Minimum water level (values see diagram on the following pages)
: Flow-straightening vane ( Page 38)
: Approach flow
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size
700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

26)
27)

24

DN2 min.

DN2 max.

a127)

a227)

a327)

b1

b2

d7

d8

d10

400
500
600
700
900
1200

700
800
900
1000
1200
1500

711
813
914
1016
1220
1524

650
700
760
810
910
1060

1120
1220
1320
1430
1630
1960

870
970
1070
1160
1360
1690

430
480
530
580
680
850

1500
1800
1800
2300
2800
3500

300
360
360
460
560
700

600
720
720
920
1120
1400

600
680
700
880
1070
1330

710
810
910
1015
1220
1520

740
860
960
1080
1290
1600

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
Designed for DN 2 min.

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

e128)

e2

h7

lmin.

m27)

m127)

n27)

p127)

p227)

t328)

t4 min.29)

t5 min.27)

t9

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

450
519
519
673
833
1048

750
900
900
1150
1400
1750

420
525
515
765
1000
1460

1500
1800
1800
2300
2800
3500

1170
1270
1380
1520
1720
2050

455
505
560
625
725
895

1260
1375
1480
1620
1850
2180

960
1075
1180
1280
1510
1840

1060
1175
1280
1380
1610
1940

380
440
440
560
680
860

2400
2450
2650
3250
4000
4050

770
835
925
980
1100
1300

570
660
660
850
1050
1320

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Permissible tolerances:
Tolerances in building construction to DIN 18202, Part 4,
Group B

Discharge flanges to DIN EN 1092-1 PN6 / DIN EN


1092-2 PN6

Welded design: B/F to DIN EN ISO 13920

Loss diagram
2,5

2,0

9 10 11 12

14

13

15

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

16
17

HV ges [m]
1,0
0,8
0,6
0,5
0,4
0,3

0,2

0,1

0,1

0,2

0,3

0,4 0,5 0,6

0,8 1

Q [m3/s]

Calculation formulas:
H = Hgeo + Hv
Hv

Loss in the riser (pipe friction)

HV ges. comprises:

Hv ges. (see diagram)


Elbow

Discharge pipe length = 5 x DN2


Swing check valve
Outlet losses v2/2g

28)
29)

Always observe this dimension.


Value for maximum motor length

Amacan P

25

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum water level diagram
Covered intake chamber

Key
3 - Amacan P 700 - 470
4 - Amacan P 800/900 - 540
5 - Amacan P 1000 - 700
6 - Amacan P 1200 - 870
7 - Amacan P 1500 - 1060

t1 [mm]
4000
3000
2500
2000
7

1600

6
5

1200

1000
900
800
700
600
500
400

26

0,1

0,2

0,3 0,4 0,5 0,6 0,8 1

Amacan P

1,5

2 2,5 3

6 7 8
Q [m3/s]

Water: Water Transport


Submersible Pump in Discharge Tube
DU type of installation (500-270 to 600-350)

DN2

p2
p1

X
a

a1
a2

200

200

Foundation recesses30)
300

A
1

250

t4

D
200

2
t2

Section A - A:

Y
h7
d8
d9

m
Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

B-B
e1

h7

45

t3

t1

4
b

d7

b1

Detailed view Y:
seat ring

0 - 10
vmax. = 1 m/s

b2

: Vent line
: Minimum water level (values see diagram on the next page)
: Flow-straightening vane ( Page 38)
: Approach flow
: Not pressure-proof
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size

500 - 270
600 - 350

30)

DN2

DN2

min.

max.

300
350

500
600

508
610

530
580

a1

650
760

a2

400
510

750
1250

b1

b2

without suction umbrella


d8

with suction
umbrella
d9

without suction umbrella


d8

with suction
umbrella
d9

150
250

150
250

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.

Amacan P

27

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

d7

500 - 270
600 - 350

d8

400
500

d9

505
610

h7

e131)
without suction umbrella
d8

with suction
umbrella
d9

350
400

400
500

650
800

lmin.

295
540

400
850

720
830

950
1060

p1

650
760

p2

750
860

t331)

t4 min.

200
320

1700
2000

t2 = 1.1 x water level, maximum 2 x t1


Height of corner lining (b1 and b2) like t2

Welded design: B/F to DIN EN ISO 13920

Permissible tolerances:

Discharge flanges to DIN EN 1092-1 PN6 / DIN EN


1092-2 PN6

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Tolerances in building construction to DIN 18202, Part 4,


Group B

Loss diagram
1,0

10 11

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

12 13

0,8

hV Kr [m]

14

0,6

15

0,5
0,4

16

0,3

17

0,2

0,1
0,08
0,06
0,05

0,04
0,1

0,2

Calculation formulas:
H = Hgeo + Hv
Hv

0,3

0,4

0,5 0,6

0,8

Q [m3/s]

HV System (valves, etc. )


HV Systemmust be determined for the specific system.

32)

28

Always observe this dimension.


Value for maximum motor length

Amacan P

Loss in the elbow hV Kr (see diagram)


Loss in the riser (pipe friction)

31)

32)

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum fluid level diagrams
Open intake chamber
(design without suction umbrella d8)

Open intake chamber


(design with suction umbrella d9)

Key

t1 [mm]
4000

t1 [mm]
4000

1 - Amacan P 500-270
2 - Amacan P 600-350

3000
2500

3000
2500

2000
1600

2000
1600

1200
1000

1200
1000

800

800 1

600
500

600
500

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

Amacan P

29

Water: Water Transport


Submersible Pump in Discharge Tube
DU type of installation (700-470 to 1500-1060)

DN2

p2
p1

X
a

a1

200

a2

200

Foundation recesses33)
300

A
1

250

t4

D
200

2
t2

Section A - A:

Y
h7
d8
d9

m
Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

B-B
e1

h7

45

t3

t1

4
b

d7

b1

Detailed view Y:
seat ring

0 - 10
vmax. = 1 m/s

b2

: Vent line
: Minimum water level (values see diagram on the following pages)
: Flow-straightening vane ( Page 38)
: Approach flow
: Not pressure-proof
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

33)

30

DN2

DN2

min.

max.

400
500
600
700
900
1200

700
800
900
1000
1200
1500

711
813
914
1016
1220
1524

650
700
760
810
910
1060

a1

860
960
1060
1160
1360
1670

a2

610
710
810
910
1110
1420

1500
1800
1800
2300
2800
3500

b1

b2

without suction umbrella


d8

with suction
umbrella
d9

without suction umbrella


d8

with suction
umbrella
d9

300
360
360
460
560
700

300
360
360
460
560
700

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

d7

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

d8

600
680
700
880
1070
1330

d9

710
810
910
1015
1220
1520

h7

e134)
without suction umbrella
d8

with suction
umbrella
d9

450
500
550
600
700
850

650
700
700
900
1100
1300

1100
1250
1250
1600
2000
2450

lmin.

420
525
515
765
1000
1460

1050
1300
1300
1700
2100
2650

930
1030
1130
1240
1440
1760

1160
1260
1360
1500
1700
2010

p1

p2

860
960
1060
1160
1360
1670

960
1060
1160
1260
1460
1770

t334)

t4 min.

380
440
440
560
680
860

2400
2450
2650
3250
4000
4050

t2 = 1.1 x water level, maximum 2 x t1


Height of corner lining (b1 and b2) like t2

Welded design: B/F to DIN EN ISO 13920

Permissible tolerances:

Discharge flanges to DIN EN 1092-1 PN6 / DIN EN


1092-2 PN6

35)

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Tolerances in building construction to DIN 18202, Part 4,


Group B

Loss diagram
1,0

10 11

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

12 13

0,8

hV Kr [m]

14

0,6

15

0,5
0,4

16

0,3

17

0,2

0,1
0,08
0,06
0,05

0,04
0,1

0,2

Calculation formulas:
H = Hgeo + Hv
Hv

0,3

0,4

0,5 0,6

0,8

Q [m3/s]

Loss in the elbow hV Kr (see diagram)


Loss in the riser (pipe friction)

HV System (valves, etc. )


HV Systemmust be determined for the specific system.

34)
35)

Always observe this dimension.


Value for maximum motor length

Amacan P

31

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum fluid level diagrams
Open intake chamber
(design without suction umbrella d8)

Key

t1 [mm]
4000

3 - Amacan P 700 - 470


4 - Amacan P 800/900 - 540
5 - Amacan P 1000 - 700
6 - Amacan P 1200 - 870
7 - Amacan P 1500 - 1060

3000
2500
2000
1600

1200
1000
800
600
500
400

0,1

0,2

0,3 0,4

0,6 0,8 1

1,5

2 2,5 3

4 5 6 7 8
Q [m3/s]

1,5 2 2,5 3

4 5 6 78
Q [m3/s]

Open intake chamber


(design with suction umbrella d9)

t1 [mm]
4000
3000
2500
2000
1600

5
3

1200
1000

800
600
500
400

32

0,1

0,2

0,3 0,4

Amacan P

0,6 0,8 1

Water: Water Transport


Submersible Pump in Discharge Tube
DG type of installation (500-270 to 600-350)

p2
p1

DN2

a1

a2

200

200

Foundation recesses36)
300

200

t9

Section A - A:

45

t3 h7

Y
t1

250

t4

d10
e2

m
Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

B-B
e1

h7

45

3
b

d7
d8

b2

Detailed view Y:
seat ring

b1

0 - 90
vmax. = 1 m/s

: Vent line
: Minimum water level (values see diagram on the next page)
: Flow-straightening vane ( Page 38)
: Approach flow
: Not pressure-proof
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size
500 - 270
600 - 350

DN2 min.

DN2 max.

a1

a2

b1

b2

d7

d8

d10

300
350

500
600

508
610

530
580

650
760

400
510

750
1250

150
250

300
500

400
500

505
610

540
640

Dimensions [mm]
Size

e137)

e2

h7

lmin.

p1

p2

t337)

t4 min.38)

t9

500 - 270
600 - 350

259
375

375
625

295
540

750
1250

720
830

950
1060

650
760

750
860

200
320

1700
2000

280
470

36)
37)
38)

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.
Always observe this dimension.
Value for maximum motor length

Amacan P

33

Water: Water Transport


Submersible Pump in Discharge Tube
Tolerances for conical seat (detailed view Y): ISO 2768-mH

Permissible tolerances:
Tolerances in building construction to DIN 18202, Part 4,
Group B

Discharge flanges to DIN EN 1092-1 PN6 / DIN EN


1092-2 PN6

Welded design: B/F to DIN EN ISO 13920

Loss diagram
1,0

10 11

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

12 13

0,8

hV Kr [m]

14

0,6

15

0,5
0,4

16

0,3

17

0,2

0,1
0,08
0,06
0,05

0,04
0,1

0,2

0,3

Calculation formulas:
H = Hgeo + Hv
Hv

0,4

0,5 0,6

0,8

Q [m3/s]

Loss in the elbow hV Kr (see diagram)


Loss in the riser (pipe friction)

HV System (valves, etc. )


HV Systemmust be determined for the specific system.

Minimum water level diagram


Covered intake chamber

Key
1 - Amacan P 500-270
2 - Amacan P 600-350

t1 [mm]
4000
3000
2500
2000
1600
1200
1000
800
600
500

2
1

400
0,1

0,2

0,3 0,4

0,6 0,8 1
Q [m3/s]

34

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
DG type of installation (700-470 to 1500-1060)

p2
p1

DN2

a1

a2

200

200

Foundation recesses39)
300

200

t9

Section A - A:

45

t3 h7

Y
t1

250

t4

d10
e2

m
Detailed view X:
Support plate of the discharge tube
Drawing: without pump
Y

B-B
e1

h7

45

3
b

d7
d8

b2

Detailed view Y:
seat ring

b1

0 - 90
vmax. = 1 m/s

: Vent line
: Minimum water level (values see diagram on the following pages)
: Flow-straightening vane ( Page 38)
: Approach flow
: Not pressure-proof
: Connect the discharge pipe to the pump without transmitting any stresses or strains.
Dimensions [mm]
Size
700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

39)

DN2 min.

DN2 max.

a1

a2

b1

b2

d7

d8

d10

400
500
600
700
900
1200

700
800
900
1000
1200
1500

711
813
914
1016
1220
1524

650
700
760
810
910
1060

860
960
1060
1160
1360
1670

610
710
810
910
1110
1420

1500
1800
1800
2300
2800
3500

300
360
360
460
560
700

600
720
720
920
1120
1400

600
680
700
880
1070
1330

710
810
910
1015
1220
1520

740
860
960
1080
1290
1600

All dimensions for foundation recesses apply to discharge tube design without intermediate flange.

Amacan P

35

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions [mm]
Size

e140)

e2

h7

lmin.

p1

p2

t340)

t4 min.41)

t9

700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

450
519
519
673
833
1048

750
900
900
1150
1400
1750

420
525
515
765
1000
1460

1500
1800
1800
2300
2800
3500

930
1030
1130
1240
1440
1760

1160
1260
1360
1500
1700
2010

860
960
1060
1160
1360
1670

960
1060
1160
1260
1460
1770

380
440
440
560
680
860

2400
2450
2650
3250
4000
4050

570
660
660
850
1050
1320

Tolerances for conical seat (detailed view Y): ISO 2768-mH

Permissible tolerances:
Tolerances in building construction to DIN 18202, Part 4,
Group B

Discharge flanges to ISO 7005/2, DIN 2501 PN6

Welded design: B/F to DIN EN ISO 13920

Loss diagram
1,0

10 11

- DN2 = 200 mm
- DN2 = 250 mm
- DN2 = 300 mm
- DN2 = 350 mm
- DN2 = 400 mm
- DN2 = 500 mm
- DN2 = 600 mm
- DN2 = 700 mm
- DN2 = 800 mm
- DN2 = 900 mm
- DN2 = 1000 mm
- DN2 = 1100 mm
- DN2 = 1200 mm
- DN2 = 1300 mm
- DN2 = 1400 mm
- DN2 = 1500 mm
- DN2 = 1600 mm

12 13

0,8

hV Kr [m]

14

0,6

15

0,5
0,4

16

0,3

17

0,2

0,1
0,08
0,06
0,05

0,04
0,1

0,2

Calculation formulas:
H = Hgeo + Hv
Hv

0,3

0,4

0,5 0,6

0,8

Q [m3/s]

Loss in the elbow hV Kr (see diagram)


Loss in the riser (pipe friction)

HV System (valves, etc. )


HV Systemmust be determined for the specific system.

40)
41)

36

Always observe this dimension.


Value for maximum motor length

Amacan P

Water: Water Transport


Submersible Pump in Discharge Tube
Minimum water level diagram
Covered intake chamber

Key
3 - Amacan P 700 - 470
4 - Amacan P 800/900 - 540
5 - Amacan P 1000 - 700
6 - Amacan P 1200 - 870
7 - Amacan P 1500 - 1060

t1 [mm]
4000
3000
2500
2000
7

1600

6
5

1200

1000
900
800
700
600
500
400

0,1

0,2

0,3 0,4 0,5 0,6 0,8 1

1,5

2 2,5 3

6 7 8
Q [m3/s]

Amacan P

37

Water: Water Transport


Submersible Pump in Discharge Tube
Dimensions of the flow-straightening vane
Design of the intake chamber wall surfaces (to prevent
vortex formation)

1
3

Lifting lug
Flow-straightening vane

The flow-straightening vane is indispensable for the inlet conditions of the pump set. It prevents the development of a submerged vortex (floor vortex) which could cause a drop in performance, for example. In addition, the floor and wall surfaces
of the intake chamber should be designed as a rough concrete
surface. Rough surfaces minimise the separation of boundary
layers that may cause wall and floor vortices.

Flow-straightening vane and intake chamber


The anti-vortex vanes in the bellmouth must be aligned
with the flow-straightening vane.
The lifting lug is oriented in the same direction as the antivortex vanes in the bellmouth.

Installation position of the pump set

Variant 1
Flow-straightening vane cast from concrete
s2

Variant 2
Steel section
sR

hR

hR

s1

A
B

C
D
lR

38

Amacan P

(e1)

lR

(e1)

Anti-vortex vanes

Water: Water Transport


Submersible Pump in Discharge Tube
A
B

Bolted to the floor of the intake chamber


Flow-straightening vane centred beneath the discharge tube

C
D

Discharge tube
Intake chamber

Installation types BU, CU, DU


Dimensions [mm]
Size

hR

s1

s2

sR

(e1)

lR42)

Design without suc- Design with suction Design without suc- Design with suction
tion umbrella d8
umbrella d9
tion umbrella d8
umbrella d9
500 - 270
600 - 350
700 - 470
800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

120
190
230
265
265
335
410
515

15
20
25
25
25
30
30
40

60
70
90
100
100
120
120
140

10
10
10
12
12
12
12
12

350
400
450
500
550
600
700
850

400
500
650
700
700
900
1100
1300

Dimensions for installation types BG, CG, DG

Size

Dimensions [mm]

800 - 540
900 - 540
1000 - 700
1200 - 870
1500 - 1060

Size
500 - 270
600 - 350
700 - 470

42)

hR

s1

s2

sR

120
190
230

15
20
25

60
70
90

10
10
10

670
875
1000
1165
1165
1375
1650
2050

720
940
1200
1300
1300
1675
2050
2500

hR

s1

s2

sR

265
265
335
410
515

25
25
30
30
40

100
100
120
120
140

12
12
12
12
12

Length IR of the flow-straightening vane must be adjusted to the 45 angle of the intake chamber.

Amacan P

39

24.09.2012
1580.39/01-EN

KSB Aktiengesellschaft
P.O. Box 200743 06008 Halle (Saale) Turmstrae 92 06110 Halle (Germany)
Tel. +49 345 4826-0 Fax +49 345 4826-4699
www.ksb.com

Potrebbero piacerti anche