Sei sulla pagina 1di 19

VHF stacked antenna

VHF antenna

VHF antenna

Tx 4-port combiner

Tx 4-port combiner

BP

BP

BP

BP

BP

BP

BP

BP

Auto Filter

Auto Filter

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF TRx
XU4200

VHF TRx
XU4200

Redundant LAN Switch

Showing set of 8 Tx in M:S configuration with automatic switchover and RF relay The set be repeated for another 8 with the Tx antenna separation of approx 5 mtrs For emergency operation a set of 2 Transceivers are recommended by R&S. However its at sole discretion of AAI to use dedicated Transmitters only. If the frequency distance for some frequencies is < 300kHz, double cavity filters have to be selected to Fibre/IP Network
(Redundant IP Backbone provided by AAI)
01 02 --------19.09.2012 25.09.2012 SK PuK
2VT2
Changed

BP

Single Cavity Filter

Date

Name

Description

25.09.2012

IGI Airport Tx Site Initial Draft for Discussion Only


Tx Site (Tx-Rx separation 2km)
0000.0000.00 V
First D. SheetNr.

Certified Norm Draw.Nr. Date Name

(prerequisite: min. 300 kHz frequency seperation and min. 2000m distance from Rx site otherwise refer to option)

Version

Change Info

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF antenna

VHF antenna

VHF antenna

VHF antenna

8-port Rx Multicoupler ATCMC8

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

Auto Filter

Auto Filter

8-port Rx Multicoupler ATCMC8

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF TRx
XU4200

VHF TRx
XU4200

Redundant LAN Switch

Showing set of 8 Rx in M:S configuration. The set be repeated for another 8 with the Rx antenna separation of approx 5 mtrs to Fibre/IP Network
(Redundant IP Backbone provided by AAI)

For emergency operation a set of 2 Transceivers are recommended by R&S. However its at sole discretion of AAI to use dedicated Receivers only (in that case the autofilter wont be needed)

01 02

---------

19.09.2012 25.09.2012

SK PuK

2VT2
Changed

Date

Name

Description

25.09.2012

IGI Airport Rx Site


(prerequisite: min. 300 kHz frequency seperation and min. 2000m distance from Tx site otherwise refer to option)

Certified Norm Draw.Nr. Date Name

Initial Draft for Discussion Only


Rx Site (Tx-Rx separation 2km)
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF stacked antenna

Tx 4-port combiner

Tx 4-port combiner

BP

BP

BP

BP

BP

BP

BP

BP

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

Redundant LAN Switch

Showing set of 8 Tx for Fallback operation in case of failure of both M and S radios The set be repeated for another 8 with the Tx antenna separation of approx 5 mtrs The amount of fallback radios can be equal or even less than Main-Standby radios. If the radios are less, the BPs have to be exchanged with Automatic filters If the frequency distance for some frequencies is < 300kHz, double cavity filters have to be selected
BP

Single Cavity Filter

to Fibre/IP Network
(Redundant IP Backbone provided by AAI)

01 02

---------

19.09.2012 25.09.2012

SK PuK

2VT2
Changed

Date

Name

Description

25.09.2012

IGI Airport Tx Site


(prerequisite: min. 300 kHz frequency seperation and min. 2000m distance from Rx site otherwise refer to option)
Draw.Nr.

Certified Norm

Initial Draft for Discussion Only


Tx Site - Fallback arrangement
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

Date

Name

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF antenna

VHF antenna

8-port Rx Multicoupler ATCMC8

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

8-port Rx Multicoupler ATCMC8

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

Redundant LAN Switch

Showing set of 16 Rx in for fallback arrangement in case both M and S Receivers fails. The set be repeated for another set with the Rx antenna separation of approx 5 mtrs to Fibre/IP Network
(Redundant IP Backbone provided by AAI)

The amount of fallback radios can be equal or even less than Main-Standby radios.

01 02

---------

19.09.2012 25.09.2012

SK PuK

2VT2
Changed

Date

Name

Description

25.09.2012

IGI Airport Rx Site


(prerequisite: min. 300 kHz frequency seperation and min. 2000m distance from Tx site otherwise refer to option)

Certified Norm Draw.Nr. Date Name

Initial Draft for Discussion Only


Rx Site - Fallback arrangement
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF Stacked Antenna

VHF Antenna

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 58

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 1316

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 2124

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 2932

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 3740

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 4547

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 58

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 1316

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 2124

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 2932

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 3740

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 4547

VHF TRx (Transceiver) Emergency Operation with Autotune Filters 2

Block of 4 Tx (M:S) With BP filter and 4 port star combiner Freq 14

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 912

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 1720

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 2528

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 3336

Block of 4 Tx (M:S) With BP filter and 4 port star combiner 4144

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner Freq 14

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 912

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 1720

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 2528

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 3336

Block of 4 Tx (Fallback) With BP filter and 4 port star combiner 4144

VHF TRx (Transceiver) Emergency Operation with Autotune Filters 1

01 02

---------

19.09.2012 25.09.2012

SK PuK

2VT2
Changed

Date

Name

Description

25.09.2012

IGI Airport Tx Site


(prerequisite: min. 300 kHz frequency seperation and min. 2000m distance from Rx site otherwise refer to option)
Draw.Nr.

Certified Norm

Initial Draft for Discussion Only


Tx Site Overview
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

Date

Name

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF Stacked Antenna

VHF Antenna
Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Isolation approx 30 dB (5m)

Block of 8 Rx (Main) With Multicoupl er 916

Block of 8 Rx (Main) With Multicoupl er 2532

Block of 8 Rx (Main) With Multicoupl er 4147

Block of 8 Rx (Stndby) With Multicoupl er 916

Block of 8 Rx (Stndby) With Multicoupl er 2532

Block of 8 Rx (Stndby) With Multicoupl er 4147

Block of 8 Rx (Fallback) With Multicoupl er 916

Block of 8 Rx (Fallback) With Multicoupl er 2532

Block of 8 Rx (Fallback) With Multicoupl er 4147

VHF TRx (Transceiver) Emergency Operation with Autotune Filters 2

Block of 8 Rx (Main) With Multicoupl er Freq 18

Block of 8 Rx (Main) With Multicoupl er 1724

Block of 8 Rx (Main) With Multicoupl er 3340

Block of 8 Rx (Stndby) With Multicoupl er 18

Block of 8 Rx (Stndby) With Multicoupl er 1724

Block of 8 Rx (Stndby) With Multicoupl er 3340


01 02

Block of 8 Rx (Fallback) With Multicoupl er Freq 18


---------

Block of 8 Rx (Fallback) With Multicoupl er 1724


19.09.2012 25.09.2012 SK PuK
2VT2
Changed

Block of 8 Rx (Fallback) With Multicoupl er 3340


Date Name Description

VHF TRx (Transceiver) Emergency Operation with Autotune Filters 1

25.09.2012

IGI Airport Rx Site


(prerequisite: min. 300 kHz frequency seperation and min. 2000m distance from Tx site otherwise refer to option)

Certified Norm Draw.Nr. Date Name

Initial Draft for Discussion Only


Rx Site Overview
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF stacked antenna

VHF antenna

VHF antenna

Tx 4-port combiner

Tx 4-port combiner

BP BP

BP BP

BP BP

BP BP

BP BP

BP BP

BP BP

BP BP Auto Filter Auto Filter

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF Tx Main SU4200

VHF Tx Stby SU4200

VHF TRx
XU4200

VHF TRx
XU4200

Redundant LAN Switch

Showing set of 8 Tx in M:S configuration with automatic switchover and RF relay The set be repeated for another 8 with the Tx antenna separation of approx 5 mtrs For emergency operation a set of 2 Transceivers are recommended by R&S. However its at sole discretion of AAI to use dedicated Transmitters only. to Fibre/IP Network
(Redundant IP Backbone provided by AAI)
01 02 --------19.09.2012 25.09.2012 SK PuK
2VT2
Changed

BP BP

Dual Cavity Filter

Date

Name

Description

25.09.2012

IGI Airport Tx Site


(prerequisite: min. 300 kHz frequency seperation and less than 2000m distance from Rx site)

Certified Norm Draw.Nr. Date Name

Initial Draft for Discussion Only


Tx Site Option
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF antenna VHF antenna VHF antenna VHF antenna

8-port Rx Multicoupler ATCMC8


BP BP BP BP BP BP BP BP

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

VHF Rx Main
EU4200C

Auto Filter

Auto Filter

8-port Rx Multicoupler ATCMC8


BP BP BP BP BP BP BP BP

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF Rx Stby
EU4200C

VHF TRx
XU4200

VHF TRx
XU4200

Redundant LAN Switch

Showing set of 8 Rx in M:S configuration. The set be repeated for another 8 with the Rx antenna separation of approx 5 mtrs to Fibre/IP Network
(Redundant IP Backbone provided by AAI)

For emergency operation a set of 2 Transceivers are recommended by R&S. However its at sole discretion of AAI to use dedicated Receivers only (in that case the autofilter wont be needed)

01 02

---------

19.09.2012 25.09.2012

SK PuK

2VT2
Changed

Date

Name

Description

25.09.2012

IGI Airport Rx Site


(prerequisite: min. 300 kHz frequency seperation and less than 2000m distance from Tx site)
Draw.Nr.

Certified Norm

Initial Draft for Discussion Only


Rx Site Option
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

Date

Name

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF stacked antenna

Tx 4-port combiner

Tx 4-port combiner

BP BP

BP BP

BP BP

BP BP

BP BP

BP BP

BP BP

BP BP

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

VHF Tx Fallback SU4200

Redundant LAN Switch

Showing set of 8 Tx for Fallback operation in case of failure of both M and S radios The set be repeated for another 8 with the Tx antenna separation of approx 5 mtrs

BP BP

Dual Cavity Filter

to Fibre/IP Network
(Redundant IP Backbone provided by AAI)
01 02 --------19.09.2012 25.09.2012 SK PuK
2VT2
Changed

Date

Name

Description

25.09.2012

IGI Airport Tx Site


(prerequisite: min. 300 kHz frequency seperation and less than 2000m distance from Rx site)
Draw.Nr.

Certified Norm

Initial Draft for Discussion Only


Tx Site - Fallback option
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

Date

Name

ROHDE&SCHWARZ
For device: Reg.i.V.

0000.0000.00

VHF antenna VHF antenna

8-port Rx Multicoupler ATCMC8


BP BP BP BP BP BP BP BP

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

8-port Rx Multicoupler ATCMC8


BP BP BP BP BP BP BP BP

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

VHF Rx Fallback
EU4200C

Redeundant LAN Switch

Showing set of 16 Rx in for fallback arrangement in case both M and S Receivers fails. to Fibre/IP Network
(Redeundant IP Backbone provided by AAI)
01 02 --------19.09.2012 25.09.2012 SK PuK
2VT2
Changed

The set be repeated for another set with the Rx antenna separation of approx 5 mtrs

Date

Name

Description

25.09.2012

IGI Airport Rx Site


(prerequisite: min. 300 kHz frequency seperation and less than 2000m distance from Tx site)
Draw.Nr.

Certified Norm

Initial Draft for Discussion Only


Rx Site - Fallback option
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

Date

Name

ROHDE&SCHWARZ
For device: Reg.i.V.

10

0000.0000.00

60 m

80 m
01 02 --------19.09.2012 25.09.2012 SK PuK
2VT2
Changed

Date

Name

Description

Stacked Antenna Transceiver Antenna

25.09.2012

Certified Norm Draw.Nr. Date Name

IGI Airport Tx Site


Antenna Location

Initial Draft for Discussion Only


Antenna Locations - Tx Site
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

ROHDE&SCHWARZ
For device: Reg.i.V.

11

0000.0000.00

40 m

60 m

Stacked Antenna Transceiver Antenna

01 02

---------

19.09.2012 25.09.2012

SK PuK

2VT2
Changed

Date

Name

Description

25.09.2012

Certified Norm Draw.Nr. Date Name

IGI Airport Rx Site


Antenna Location

Initial Draft for Discussion Only


Antenna Locations - Rx Site
0000.0000.00 V
First D.

SheetNr.

Version

Change Info

ROHDE&SCHWARZ
For device: Reg.i.V.

12

0000.0000.00

1 Cable In/outlet
46 HU

2 Front View
Equipment Rack Connection Panel LAN Switch

3 Items in ( xxx ) may not be installed depending on rack arrangement

40 HU

B
Rohde & Schwarz GmbH & Co. KG Fr dieses Dokument behalten wir uns alle Rechte vor! For this document all rights are reserved!

35 HU

30 HU

25 HU
2600

Top View

20 HU

15 HU

BP Filter with 4 port Star Combiner


D

10 HU

5 HU

BP Filter with 4 port Star Combiner

Maintenance Area

mm
600
Vertragspartner Vertragspartner / Contractor / Contractor Vertrag Vertrag Nr.Nr. / Contract / Contract No. No. VS-Einstufung / Classific. Datei / File RF CONCEPT_AAI_27092012_1.0.V SD Projekt Projekt/ /Project Project

Royal Malaysian Navy

Draft Version xXx


Toleranz Toleranz Tol. Tol. Bennennung / Designation

UNCLASS
Werkstoff Werkstoff Material Material

Untitled xXx
Sprache Sprache/ /Lang. Lang. Aei. Aei. // C.l. C.l.

Mastab Mastab Scale Scale

1:1:10 1

Possible Rack Arrangement for discussion only / DRAFT 8 line VHF Rack - Main/Standby
Abteilung Abteilung Dept. Dept. Name Name

F
13

en en
Pushkar

02 01 xxxx X xxxx 4

Dokument DokumentNr. Nr./ /Document DocumentNo. No.

Datum Date

25 Sept 2012

RSINDIA 2SP5

1 Cable In/outlet
46 HU

2 Front View
Equipment Rack Connection Panel LAN Switch

3 Items in ( xxx ) may not be installed depending on rack arrangement

40 HU

B
Rohde & Schwarz GmbH & Co. KG Fr dieses Dokument behalten wir uns alle Rechte vor! For this document all rights are reserved!

35 HU

30 HU

BLANK PANEL

25 HU
2600

Top View

20 HU

15 HU

BP Filter with 4 port Star Combiner


D

10 HU

5 HU

BP Filter with 4 port Star Combiner

Maintenance Area

mm
600
Vertragspartner Vertragspartner / Contractor / Contractor Vertrag Vertrag Nr.Nr. / Contract / Contract No. No. VS-Einstufung / Classific. Datei / File RF CONCEPT_AAI_27092012_1.0.V SD Projekt Projekt/ /Project Project

Royal Malaysian Navy

Draft Version xXx


Toleranz Toleranz Tol. Tol. Bennennung / Designation

UNCLASS
Werkstoff Werkstoff Material Material

Untitled xXx
Sprache Sprache/ /Lang. Lang. Aei. Aei. // C.l. C.l.

Mastab Mastab Scale Scale

1:1:10 1

Possible Rack Arrangement for discussion only / DRAFT 8 line VHF Fallback
Abteilung Abteilung Dept. Dept. Name Name

F
14

en en
Pushkar

02 01 xxxx X xxxx 4

Dokument DokumentNr. Nr./ /Document DocumentNo. No.

Datum Date

25 Sept 2012

RSINDIA 2SP5

A
500mm

8 line VHF Rack (Main/Standby)

8 line VHF Rack (Main/Standby)

8 line VHF Rack (Main/Standby)

8 line VHF Rack (Main/Standby)

8 line VHF Rack (Main/Standby)

8 line VHF Rack (Main/Standby)

B
Rohde & Schwarz GmbH & Co. KG Fr dieses Dokument behalten wir uns alle Rechte vor! For this document all rights are reserved!

Rack (spare)

Rack (Spare)

D
8 line VHF Rack (Fallback) 8 line VHF Rack (Fallback) 8 line VHF Rack (Fallback) 8 line VHF Rack (Fallback) 8 line VHF Rack (Fallback) 8 line VHF Rack (Fallback)

Vertragspartner / Contractor

Vertrag Nr. / Contract No.

VS-Einstufung / Classific.

Datei / File
RF CONCEPT_AAI_27092012_1.0.VSD

Projekt / Project

Royal Malaysian Navy

DraftxXx Version
Toleranz Tol. Bennennung / Designation

UNCLASS
Werkstoff Material

Untitled xXx
Sprache / Lang. Aei. / C.l.

Mastab Scale

1:10 1: 1

Possible Rack Arrangement for discussion only / DRAFT

F
15

en
Pushkar

01 02 xxxx X xxxx 4

Tx Rack Layout Overview


Datum Date

Dokument Nr. / Document No.

25 Sept 2012

Abteilung Dept.

RSINDIA 2SP5

Name Name

1 Cable In/outlet
46 HU

2 Front View
Equipment Rack Connection Panel BLANK PANEL LAN Switch

3 Items in ( xxx ) may not be installed depending on rack arrangement

40 HU

B
Rohde & Schwarz GmbH & Co. KG Fr dieses Dokument behalten wir uns alle Rechte vor! For this document all rights are reserved!

35 HU

30 HU

25 HU
BLANK PANEL

Top View

2600

20 HU

BLANK PANEL

15 HU

BLANK PANEL

D
10 HU

BLANK PANEL

5 HU

Maintenance Area

mm
600
Vertragspartner Vertragspartner / Contractor / Contractor Vertrag Vertrag Nr.Nr. / Contract / Contract No. No. VS-Einstufung / Classific. Datei / File RF CONCEPT_AAI_27092012_1.0.V SD Projekt Projekt/ /Project Project

Royal Malaysian Navy

Draft Version xXx


Toleranz Toleranz Tol. Tol. Bennennung / Designation

UNCLASS
Werkstoff Werkstoff Material Material

Untitled xXx
Sprache Sprache/ /Lang. Lang. Aei. Aei. // C.l. C.l.

Mastab Mastab Scale Scale

1:1:10 1

Possible Rack Arrangement for discussion only / DRAFT 3 x 8 Channel VHF Main Rx Rack
Abteilung Abteilung Dept. Dept. Name Name

F
16

en en
Pushkar

02 01 xxxx X xxxx 4

Dokument DokumentNr. Nr./ /Document DocumentNo. No.

Datum Date

25 Sept 2012

RSINDIA 2SP5

1 Cable In/outlet
46 HU

2 Front View
Equipment Rack Connection Panel BLANK PANEL LAN Switch

3 Items in ( xxx ) may not be installed depending on rack arrangement

40 HU

B
Rohde & Schwarz GmbH & Co. KG Fr dieses Dokument behalten wir uns alle Rechte vor! For this document all rights are reserved!

35 HU

30 HU

25 HU
BLANK PANEL

Top View

2600

20 HU

BLANK PANEL

15 HU

BLANK PANEL

D
10 HU

BLANK PANEL

5 HU

Maintenance Area

mm
600
Vertragspartner Vertragspartner / Contractor / Contractor Vertrag Vertrag Nr.Nr. / Contract / Contract No. No. VS-Einstufung / Classific. Datei / File RF CONCEPT_AAI_27092012_1.0.V SD Projekt Projekt/ /Project Project

Royal Malaysian Navy

Draft Version xXx


Toleranz Toleranz Tol. Tol. Bennennung / Designation

UNCLASS
Werkstoff Werkstoff Material Material

Untitled xXx
Sprache Sprache/ /Lang. Lang. Aei. Aei. // C.l. C.l.

Mastab Mastab Scale Scale

1:1:10 1

Possible Rack Arrangement for discussion only / DRAFT 3 x 8 Channel VHF Stndby Rx Rac
Abteilung Abteilung Dept. Dept. Name Name

F
17

en en
Pushkar

02 01 xxxx X xxxx 4

Dokument DokumentNr. Nr./ /Document DocumentNo. No.

Datum Date

25 Sept 2012

RSINDIA 2SP5

1 Cable In/outlet
46 HU

2 Front View
Equipment Rack Connection Panel BLANK PANEL LAN Switch

3 Items in ( xxx ) may not be installed depending on rack arrangement

40 HU

B
Rohde & Schwarz GmbH & Co. KG Fr dieses Dokument behalten wir uns alle Rechte vor! For this document all rights are reserved!

35 HU

30 HU

25 HU
BLANK PANEL

Top View

2600

20 HU

BLANK PANEL

15 HU

BLANK PANEL

D
10 HU

BLANK PANEL

5 HU

Maintenance Area

mm
600
Vertragspartner Vertragspartner / Contractor / Contractor Vertrag Vertrag Nr.Nr. / Contract / Contract No. No. VS-Einstufung / Classific. Datei / File RF CONCEPT_AAI_27092012_1.0.V SD Projekt Projekt/ /Project Project

Royal Malaysian Navy

Draft Version xXx


Toleranz Toleranz Tol. Tol. Bennennung / Designation

UNCLASS
Werkstoff Werkstoff Material Material

Untitled xXx
Sprache Sprache/ /Lang. Lang. Aei. Aei. // C.l. C.l.

Mastab Mastab Scale Scale

1:1:10 1

Possible Rack Arrangement for discussion only / DRAFT 3 x 8 Channel VHF Fallback Rx R
Abteilung Abteilung Dept. Dept. Name Name

F
18

en en
Pushkar

02 01 xxxx X xxxx 4

Dokument DokumentNr. Nr./ /Document DocumentNo. No.

Datum Date

25 Sept 2012

RSINDIA 2SP5

500mm

B
Rohde & Schwarz GmbH & Co. KG Fr dieses Dokument behalten wir uns alle Rechte vor! For this document all rights are reserved!

B
3x8 channel VHF Rx Rack (Main) 3x8 channel VHF Rx Rack (Main) 3x8 channel VHF Rx Rack (Standby) 3x8 channel VHF Rx Rack (Standby)

Rack (spare)

Rack (Spare)

3x8 channel VHF Rx Rack (Fallback)

3x8 channel VHF Rx Rack (Fallback)

Vertragspartner / Contractor

Vertrag Nr. / Contract No.

VS-Einstufung / Classific.

Datei / File
RF CONCEPT_AAI_27092012_1.0.VSD

Projekt / Project

Royal Malaysian Navy

DraftxXx Version
Toleranz Tol. Bennennung / Designation

UNCLASS
Werkstoff Material

Untitled xXx
Sprache / Lang. Aei. / C.l.

Mastab Scale

1:10 1: 1

Possible Rack Arrangement for discussion only / DRAFT

F
19

en
Pushkar

01 02 xxxx X xxxx 4

Rx Rack Layout Overview


Datum Date

Dokument Nr. / Document No.

25 Sept 2012

Abteilung Dept.

RSINDIA 2SP5

Name Name

Potrebbero piacerti anche