Interpretation of Cell Tower Readings Measured by TERM Cell / TCIL vs.

Safe level for Health by Neha Kumar, Director, Nesa Radiation Solutions Pvt. Ltd.
Dear All, I have been working on Cell Tower Radiation issue for the past 3.5 years along with my father Prof. Girish Kumar from IIT Bombay. We have been studying the effects of cell tower radiation on humans and environment and have prepared several reports and submitted the same to DOT and several officials. My work can be seen at: http://neha-wilcom.blogspot.in/ . I also have a company NESA Radiation Solutions Pvt. Ltd. through which we have been carrying out radiation measurements for people in residences and offices and have seen a strong correlation between high radiation levels and health problems. Recently government has started carrying out radiation measurements for residents through Telecommunications Consultants India Ltd (TCIL). However everywhere they measure, the readings indicate that levels are within norm. This has led to major confusion among common people. Please find the report prepared by industry/their associates for a building in Thane, Mumbai:

Figure 1 EMF report of TERM Cell for a building in Thane, Mumbai

Please note, government of India has adopted a very high radiation norm and what is safe from health point of view is much lower. Operators are within the norm so they keep saying they are within safe guidelines. Efforts should be to convince the government to adopt better radiation norms.

Interpretation of the readings: 9.2W/sq.m = 9200 mW/sq.m - ICNIRP Guideline1998 for GSM 1800 - The Department of Telecommunications, India adopted this norm in 2008 0.92W/sq.m = 920 mW/sq.m - 1/10th of ICNIRP - The Department of Telecommunications, India adopted this norm from 1 Sept 2012 0.0001W/sq.m = 0.1 mW/sq.m - Safe from health point of view [According to Bioinitiative Report 2007 and recommendations of Antenna Lab, IIT Bombay] 0.185W/sq.m (-02dBm) = 185mW/sq.m - Maximum Reading Measured in this building [Flat No.1002 - Bedroom] (which is within the government norm hence operators have said that the levels are within guideline) This reading is very high from health point of view. People have been complaining of health problems like sleep disturbance, headaches, concentration problems, joint pains even above 0.001W/sq.m.= 1 mW/sq.m Above 0.01W/sq.m = 10 mW/sq.m, severe health problems and cancer cases have also been reported in few years. ICNIRP Guidelines are meant for short term exposure and not for long term exposure. In fact, the short term exposure guideline is only for 6 minutes/day. By extrapolation, 1/10 of ICNIRP is valid only for 6x10 = 60 min = 1 hour per day. People living close to cell tower radiation are exposed to radiation 24x7. Please go through the report: Guideline-Austrian-Medical-Assoc-EMF-syndrome.pdf http://www.scribd.com/doc/87308119 Page 9 mentions that greater than 1 mW/sq.m is very far above normal.

Figure 2 Guideline-Austrian-Medical-Assoc-EMF-syndrome - Page 9

According to Prof. Girish Kumar's report - http://www.scribd.com/doc/132189401 greater than 1mW/sq.m over a few years of exposure leads to health problems. If you have any queries, please feel free to write to me. With regards, Neha Kumar Email nesaglobal@gmail.com, info@nesa.co.in Nesa Radiation Solutions Pvt. Ltd. 2nd Floor, Plot No. 31, Sector 19C, Vashi Navi Mumbai 400 705 Tel: (022) 41241800 Website - www.nesa.co.in Blog and Twitter links on Cell Tower Radiation http://neha-wilcom.blogspot.com; https://twitter.com/wilcom_neha

Table 1 Conversion Chart: dBm to Watt per square meter


NESA Radiation Solutions Pvt. Ltd., Dreams Mall, L-115, Lower Ground Floor, LBS Road, Bhandup (West), Mumbai - 400078, Tel: (022) 21663355 Website: www.nesa.co.in Power(dBm) GSM 900 (Watt/m) GSM 1800 (Watt/m) 10 0.706860 2.827440 9 0.561479 2.245915 8 0.445999 1.783994 7 0.354269 1.417077 6 0.281406 1.125624 5 0.223529 0.894115 4 0.177555 0.710221 3 0.141037 0.564148 2 0.112030 0.448119 1 0.088988 0.355954 0 0.070686 0.282744 -1 0.056148 0.224592 -2 0.044600 0.178399 -3 0.035427 0.141708 -4 0.028141 0.112562 -5 0.022353 0.089412 -6 0.017756 0.071022 -7 0.014104 0.056415 -8 0.011203 0.044812 -9 0.008899 0.035595 -10 0.007069 0.028274 -11 0.005615 0.022459 -12 0.004460 0.017840 -13 0.003543 0.014171 -14 0.002814 0.011256 -15 0.002235 0.008941 -16 0.001776 0.007102 -17 0.001410 0.005641 -18 0.001120 0.004481 -19 0.000890 0.003560 -20 0.000707 0.002827 -21 0.000561 0.002246 -22 0.000446 0.001784 -23 0.000354 0.001417 -24 0.000281 0.001126 -25 0.000224 0.000894 -26 0.000178 0.000710 -27 0.000141 0.000564 -28 0.000112 0.000448 -29 0.000089 0.000356 -30 0.000071 0.000283 -31 0.000056 0.000225 -32 0.000045 0.000178 -33 0.000035 0.000142 -34 0.000028 0.000113 -35 0.000022 0.000089 -36 0.000018 0.000071 -37 0.000014 0.000056 -38 0.000011 0.000045 -39 0.000009 0.000036 -40 0.000007 0.000028 3G (Watt/m) 5.238180 4.160834 3.305068 2.625309 2.085357 1.656458 1.315771 1.045154 0.830196 0.659448 0.523818 0.416083 0.330507 0.262531 0.208536 0.165646 0.131577 0.104515 0.083020 0.065945 0.052382 0.041608 0.033051 0.026253 0.020854 0.016565 0.013158 0.010452 0.008302 0.006594 0.005238 0.004161 0.003305 0.002625 0.002085 0.001656 0.001316 0.001045 0.000830 0.000659 0.000524 0.000416 0.000331 0.000263 0.000209 0.000166 0.000132 0.000105 0.000083 0.000066 0.000052

0.0001 Watt/m= 0.1 milliWatt/m= 100 microWatt/m= Safe standard as per Bioinitiaitve Report 2007 [for Continuous Indoor Exposure] and recommended by Antenna Lab, IIT Bombay
For GSM 900: 0.45 Watt/m = 450 milliWatt/m- 1/10th of ICNIRP - Department of Telecommunications, India adopted this norm from 1 sep 12 For GSM 1800: 0.92 Watt/m= 920 milliWatt/m- 1/10th of ICNIRP - Department of Telecommunications, India adopted this norm from 1 sep12 ICNIRP Guidelines are meant for short term exposure and not for long term exposure. Short term exposure guideline is only for 6 minutes/day. People living close to cell tower radiation are exposed to radiation 24x7.

Potrebbero piacerti anche