COMPARISION OF TRUE POWER SINEWAVE "SAPHIRE" HOME UPS WITH OTHER MAKES

Make
TRUE POWER M S L G/K
Wide input AC window 80V~300V INPUT AC WINDOW INPUT AC WINDOW INPUT AC WINDOW INPUT AC WINDOW
suits urban as well as rural 120V~290V 116V~280V 120V~280V 120V~280V
conditions
Precise & Accurate I/P voltage Average based design, No accuracy No accuracy Available
management at UPS mode for I/P Frequency dependecy on opto dependecy on opto
computer type of load as peak dependent coupler where the coupler where the
based design which is 180V~265V linearity curve is linearity curve is differ
differ from piece to from piece to piece &
piece & temperature temperature dependent
dependent
I/P bypass load capacity (10A/2Kw Available I/P bypass load I/P bypass load I/P bypass load
approx) capacity 5A only capacity 5A only capacity 5A only
Noiseless hasselfree performance Irritating humming Irritating humming Irritating humming Available
during mains mode as well as sound (buzz) during sound (buzz) during sound (buzz) during
backup mode as high frequency mains mode which is mains mode as well mains mode as well as
switching of the power devices is not acceptable, as as backup mode backup mode which is
present. Noise level of <45db at one mains mode switching which is not not acceptable, as
meter is achieved frequency is low acceptable, as switching frequency is
switching frequency low in both the modes
is low in both the
modes
Input in Output protection first time Not Available
used in India by True Power digital
pure sinewave inverter.It protects
the system for causing a failure
under this condition.
Complete deep discharge protection Not Available
available charges battery from as
low as 3V
Yellow mode neuro intelligence Not Available
saves energy at no load
Green mode Not Available
Benchmark Charging:- The smart Not Available
software continuously measure the
power cut durations & after a
permissible period it changes the
voltage profile level at 14.2V for a
charge cycle so that the battery
should recover from the gravity
profile loss due to ageing
First charge cycle is performed at Not Available
a voltage profile level at 14.2V which
is recommendable for the longer life
of the battery
Not Available Charging
It charges the battery to as low as current starts reducing from below 150V AC
80V & as high as 300V AC mains.It
achieves full charging current of as
low as 120V of the mains suitable
for urban as well as rural conditions
Not Available
Due to the ageing of the battery the
gravity profile of battery is gradually
deteorating no other inverter
available in the industry is cope with
gradually deteorating profile. We
have introduced the gravity profile
management technique which
continuous monitor the gravity
profile of the battery & adjust the
charging profile according to the
demand & type of the battery
Hard to service,only Very difficult to
Easy to service & can be serviced can be serviced in the service even card
by authorised dealer/distributor to Available Available authorised service level replacement is
reduce the lead time of the service. station,time of service not possible in the
high. field.
A bulky heat sink is
mounted on the
outside of the body of
the inverter which is
going to heat and is
not recommendable
Force cooling available Not available Available Available as per the UL
standards as it is high
temperature area
may be injurious to
human touch and
may damage the
leads nearby.
TRUE POWER MAKE
Peak current Peak current
Peak current
protection is not protection is not
protection is not
available in the available in the
Multi stage peak current protection available in the system
system which may system which may
available during the short circuit to which may lead to Available
lead to failure of the lead to failure of the
increase the reliability of the system. failure of the system
system under system under
under continous short
continous short continous short circuit
circuit condition
circuit condition condition
Boost based multi stage
IBM(Intelligent Battery
Management) based charging.IBM Normal battery charging techniques are used where the power factor is less than 0.9 and
improves the power factor of the hence leads to the electricity bills.
system near to 0.9 which reduces
the electricity bills.
Higher battery life.BTC(Battery
Temperature Control) management
first time used in India which
increases the battery life by 35%.In
this technique the parameter of the Not Available
battery are being controlled to
maintain the temperature of the
battery to the standard level which
improves the battery life.