GLENIUM ACE 6 SURETEC


Ultra-High early strength gaining superplasticising admixture with super slump retention for precast

Description workability at the time of placing. With application of


GLENIUM ACE 6 SURETEC is the superplasticiser sureTEC, concrete producers gain control over the
based on second generation polycarboxylic ether workability of concrete at the time of placing – far
polymers, developed using nano-technology. The beyond previously known levels. No matter if low
product has been primarily developed for applications workability or high performance self compacting
in high performance pre-cast concrete to facilitate high concrete, the placing workability remain unchanged
early strength gains with super slump retention. from batch to batch. As a result concrete producers
GLENIUM ACE 6 SURETEC is free of chloride & low are enabled to provide a specified workability of
alkali. It is compatible with all types of cements. concrete consistently, even if hot weather or traffic
conditions or other factors make it difficult to estimate
Uses
the time window between batching and placing.
„ GLENIUM ACE 6 SURETEC is suitable for making
precast concrete elements at all workability’s
SURETEC also provides value to the end customers.
including Rheoplastic or Super workable concrete
The excellence in terms of quality control of concrete
having fluid consistence, no segregation, a low
at the same time assures consistency of workmanship,
water binder ratio and, consequently high early
a decisive prerequisite for a long life-cycle of a
and long term strengths
concrete structure.
„ GLENIUM ACE 6 SURETEC may be used in
combination with GLENIUM STREAM 2 for
Typical Properties
producing Rheodynamic concrete, capable of self-
compaction, even in the presence of dense Aspect : Light brown liquid
reinforcement with out the aid of vibration, for Relative Density : 1.08 ± 0.02 at 25°C
making precast elements. pH : >6
„ As an component of Zero Energy System™ Chloride ion content : < 0.2%
Advantages Standards
„ Produces Rheoplastic and Rheodynamic „ ASTM C494 Types F
concretes having a low water cement ratio „ EN 934-2 T3.1/3.2
„ Optimise curing cycles by reducing curing time or „ IS 9103
curing temperatures
„ Eliminate heat curing Specification Clause
„ Eliminate the energy required for placing, The slump-retaining hyperplasticiser shall be GLENIUM
compacting & curing (Zero Energy System™) ACE 6 SURETEC, high range water reducing, high
„ Increase productivity/ reduction in cycle time early strength gain type, Superplasticiser based on
„ Improve surface appearance polycarboxylic ether formulation. The product shall
„ Produce durable precast concrete elements have specific gravity of 1.08 & solid contents not less
„ Improved engineering properties, compared to then 38% by weight. The product shall comply with
traditional superplasticiser such as early and ASTM C494 Type F and shall be free of
ultimate compressive and flexural strengths, lignosulphonates, naphthalene salts and melamine
reduced shrinkage and low permeability. formaldehyde when subjected to IR Spectra.

ZERO ENERGY SYSTEM: Direction for use


Zero Energy System is based on a combination of the GLENIUM ACE 6 SURETEC is a ready-to-use liquid
avant-garde admixture GLENIUM ACE 6 SURETEC which is dispensed into the concrete together with the
and the innovative technology of Rheodynamic mixing water. The plasticising effect and water
concrete. The Zero Energy System has been reduction are higher if the admixture is added to the
developed to help the precast concrete producer to damp concrete after 50 to 70% of the mixing water
rationalize his production process and save on energy has been added. The addition of GLENIUM ACE 6
costs combined with improved quality of the product SURETEC to dry aggregate or cement is not
and the working conditions. recommended. Automatic dispensers are available.
Thorough mixing is essential and a minimum mixing
sureTEC – Super Retention Technology:
cycle, after the addition of the GLENIUM ACE 6
sureTEC stands for Super Retention Technology. It is a
SURETEC, of 60 seconds for forced action mixers is
concrete admixture technology that brings benefits to
recommended.
all concrete producers in terms of slump retention and
early strength development. It assures concrete
Page 1 of 2
Dosage and on the type of cement, the nature of aggregates,
Optimum dosage of GLENIUM ACE 6 SURETEC the method of transport and initial workability.
should be determined in trial mixes. As a guide, a The use of MASTERKURE 111CF, evaporation
dosage range of 300 ml to 1500ml per 100kg of reducer to prevent quick moisture loss from the
cementitious material is normally recommended. surface of the flat works such as pavements in the dry,
Because of variations in concrete materials, job site windy and hot climates is highly recommended.
conditions, and/or applications, dosages outside of the Packaging
recommended range may be required. In such cases, GLENIUM ACE 6 SURETEC is supplied in 225 kg
contact your local BASF representative. drums or in bulk on request.
Effects of over dosage
Storage and Shelf life
A severe over-dosage of GLENIUM ACE 6 SURETEC
GLENIUM ACE 6 SURETEC must be stored where
shall result in some of the followings:
temperatures do not drop below +5°C. If product has
„ Increase in air entrainment
frozen, thaw at +5°C or above and completely
„ Extension of initial and final set
reconstitute using mild mechanical agitation. Do not
„ Bleed/segregation of mix, quick loss of workability
use pressurized air for agitation. Store under cover,
„ Increased plastic shrinkage
out of direct sunlight and protect from extremes of
In the event of over-dosage, provided concrete is temperature.
properly compacted & cured, the ultimate strength of
the concrete may not be adversely affected and shall Shelf life is at least 12 months when stored as above.
generally be higher than that for normal concrete. Due Failure to comply with the recommended storage
allowance should be made for the effect of fluid conditions may result in premature deterioration of the
concrete pressure on form work, and stripping times product or packaging. For specific storage advice
should be monitored. consult your local BASF representative.
In the event of over dosage, consult your local BASF
representative immediately. Safety precautions
As with all chemical products, care should be taken
Compatibility during use and storage to avoid contact with eyes
GLENIUM ACE 6 SURETEC is compatible with most of mouth, skin and foodstuffs (which can also be tainted
the POZZOLITH series products including POZZOLITH with vapour until product fully cured or dried). Treat
55R. Use GLENIUM STREAM 2 as viscosity modifying splashes to eyes and skin immediately. If accidentally
agent in self compacting concrete. It must not be used ingested, seek immediate medical attention. Keep
in conjunction with any other admixture unless prior away from children and animals. Reseal containers
approval is received from BASF Technical Services after use. Do not reuse containers for storage of
Department. consumable item. For further information refer to the
Corrosivity – Non Chloride, Non Corrosive material safety data sheet. MSDS available on demand
GLENIUM ACE 6 SURETEC admixture will neither or on BASF construction chemicals web site.
initiate nor promote corrosion of reinforcing steel Note
embedded in concrete, prestressed concrete or
All BASF Technical Data Sheets are updated on
concrete placed on galvanized steel floor and roof
regular basis; it is the user's responsibility, to obtain
systems. Neither calcium chloride nor any calcium
the most recent issue.
chloride-based ingredients are used in the
manufacture of GLENIUM ACE 6 SURETEC Field services where provided, does not constitute
admixture. In all concrete application, GLENIUM ACE supervisory responsibility, for additional information
6 SURETEC admixture will conform to the most contact your local BASF representative.
stringent or minimum chloride ion limits currently Disclaimer
suggested by construction industry standards and Whilst any information contained herein is true, accurate and
practices. represents our best knowledge and experience, no warranty
Workability is given or implied with any recommendations made by us,
GLENIUM ACE 6 SURETEC ensures that rheoplastic our representatives or distributors, as the conditions of use
and the competence of any labour involved in the application
concrete remains workable in excess of 45 minutes at
are beyond our control.
+25°C. Workability loss is dependent on temperature,

PDS Ref. No. : GlnxA6ST/04/1108


BASF Construction Chemicals (India) Private Limited
C-68, MIDC, Thane Belapur Road, Turbhe, Navi Mumbai - 400 613 India
Tel: +91 22 27619992/3, Fax: +91 22 27619242
e-mail: basfcc@vsnl.net www.basf-cc.co.in Page 2 of 2